HomeMy WebLinkAboutT1.1-GENERAL-NOTES-AND-PROJECT-INFORMATION-Rev.1l: TYPICAL ABBREVIATIONS S.S. STAINLESS STEEL RQ ROUGH OPENING DEMOLITION GAUGE DEMO GA EFC EPDXY FLOOR COATING W/ WITH REF' REFERENCE INTER. INTERIOR EXIST, EXISTING CONC. CONCRETE FIP FOAM IN PLACE Q.G. ON CENTER GALV' GALVANIZED REQ'D REQUIRED II EACH CONT. CONTINUOUS FRP FIBERGLASS REINFORCED PLASTIC PVC POLY -VINYL CHLORIDE TOP B BOTTOM B'O' PROVIDED AND INSTALLED BY OWNER WALL TYPE LEGEND FINISH INSULAT HEIGHT GAUGE THICKNE MATERIP LOCATIC LOCATION MATERIAL THICKNESS GAUGE HEIGHT INSULATION FINISH FIRE BARRIER AND FIRE WALL LABELING: For other than existing assemblies, where there is an accessible concealed floor, floor/ceiling, or attic space, fire walls, fire barriers, smoke barriers, and smoke partitions shall be permanently identified with signs or stenciling in the concealed space and shall comply with all of the following: (1) Be located in accessible concealed floor, floor/ceiling, or attic spaces (2) Be located within 15 ft (4572 mm) of the end of each wall and at intervals not exceeding 30 ft (9144 mm) measured horizontally along the wall or partition (3) Include lettering not less than 3 in. (76 mm) in height with a minimum 3/8 in. (9.5 mm) stroke in a contrasting color (4) Identify the wall type and its fire resistive rating as applicable NOTES: 1. THICKNESSES FOR WOOD FRAMED (WF) WALLS ARE NOMINAL 2. ALL METAL WALLS TO DECK SHALL BE PROVIDED WILL SLIP TRACK (FIRE RATED WHERE REQUIRED) GOVERNING CODES AND REQUIREMENTS: CURRENT STATE OF INDIANA ADOPTED CODES (source: http://www.in.gov/dhs/2490.htm) 675 LAC 13-2.6 Indiana Building Code, 2014 Edition (IBC, 2012 Edition, 1st printing) ANSI At 17.1-2009 Effective 12/1/14 675 LAC 16-1.4 Indiana Plumbing Code, 2012 Edition Effective 12/24/12 675 LAC 17-1.8 Indiana Electrical Code 2009 Edition (NFPA 70-2008) Effective 8/26109 675 LAC 18-1.6 Indiana Mechanical Code, 2014 Edition (IMC, 2012 Edition, 1st printing) Effective 12/1/14 675 LAC 19-4 Indiana Energy Conservation Code 2010 (ASHRAE 90.1, 2007 edition, as amended)Effective 5/6/10 675 LAC 22-2.5 Indiana Fire Code, 2014 Edition (IFC 2012 Edition, 1st printing) Effective 1211114 Indiana Fuel Gas Code, 2008 Edition (IFGC, 2006 Edition, 1st printing) NFPA STANDARDS AS FOLLOWS: NFPA # Description Effective Date LAC Cite 10-2010 Portable Fire Extinguishers December 15, 2012 67$ IAC 28-1-2 11-2005 LOW Expansion Foam and Combined Systems September 22, 2006 675 IAC 28-1-3 12-2005 Carbon Dioxide Extinguishing Systems September 22, 2006 675 IAC 28-1-4 13-2010 Installation of Sprinkler Systems September 26, 2012 675 IAC 28-1-5 13R-2010 Sprinkler Systems in Residential Occupancies Up to Four Stories in Height September 26, 2012 675 IAC 28-1-6 14-2000 Installation of Standpipe and Hose Systems December 13, 2001 675 IAC 13-1-9 Repealed 3/21/14 15-2001 Water Spray Fixed Systems September 22, 2006 675 IAC 28-1-8 17-2002 Dry Chemical Extinguishing Systems September 15, 1997 675 IAC 28-1-9 17A-2002 Wet Chemical Extinguishing Systems September 22, 2006 675 IAC 28-1-1 20-1999 Installation of Centrifugal Fire Pumps December 13, 2001 675 IAC 13-1-10 Amended 12/26/02 25-2011 Inspection, Testing and Maintenance of Water Based Fire Protection Systems May 12, 2013 675 IAC 28-1-12 33-2003 Spray Application Using Flammable and Combustible Materials September 22, 2006 675 IAC 28-1-13 34-2003 Dipping and Coating Processes Using Flammable or Combustible Liquids September 22, 2006 675 IAC 28-1-14 Repealed 12/14/12 37-2002 Installation and Use of Stationary Combustion Engines and Gas Turbines September 22, 2006 675 IAC 28-1-15 50-2001 Bulk Oxygen Systems and Consumer Sites September 22, 2006 675 IAC 28-1-16 5OB-1999 Liquefied Hydrogen Systems at Consumer Sites September 22, 2006 675 IAC 28-1-17 51-2002 Design and Installation of Oxygen -Fuel Systems for Welding, Cutting and Allied Processes September 22, 2006 675 IAC 28-1-18 51A-1997 Acetylene Cylinder Charging Plants September 22, 1998 675 IAC 22-2.2-11 Repealed 12/14/12 51B-2003 Fire Prevention in Use of Cutting and Welding Processes September 22, 2006 675 IAC 28-1-20 Repealed 12/14/12 52-2002 Compressed Natural Gas (CNG) Vehicular Fuel Systems September 22, 2006 675 LAC 28-1-21 58-2004 Liquefied Petroleum Gas Code See Chap. 61 of the 2014 Indiana Fire Code 59-2004 Storage and Handling of Liquefied Petroleum Gases at Utility Gas Plants September 22, 2006 675 IAC 28-1-23 59A-2001 Production and Storage and Handling of Liquefied Natural Gas (LNG) September 22, 2006 675 IAC 28-1-24 6113-1989 Fires and Explosions in Grain Elevators & Facilities Handling Bulk Raw Agricultural Commodities October 11, 2001 675 IAC 13-1-21 70-2008 National Electrical Code August 26, 2009 675 IAC 17-1.8 72-2010 National Fire Alarm Code March 23, 2014 675 IAC 28-1-28 82-2004 Incinerators, Waste and Linen Handling Systems and Equipment September 22, 2006 675 IAC 28-1-30 86-2003 Ovens and Furnaces - Design, Location and Equipment September 22, 2006 675 IAC 28-1-31 385-2000 Tank Vehicles for Flammable and Combustible Liquids September 22, 2006 675 IAC 28-1-34 386-1990 Portable Shipping Tanks for Flammable and Combustible Liquids September 22, 1998 675 IAC 22-2.2-22 407-2001 Aircraft Fuel Servicing September 22, 2006 675 IAC 28-1-36 495-2001 Explosive Materials Code December 01, 2005 675-IAC 26-3-1 704-2001 Identification of the Fire Hazards of Materials September 22, 2006 675 IAC 28-1-38 1123-2006 Outdoor Display of Fireworks June 16, 2008 675 IAC 28-1-39 1126-2001 Use of Pyrotechnics Before a Proximate Audience October 20, 2005 675 IAC 22-2.2-26 2001-2004 Clean Agent Fire Extinguishing Systems September 22, 2006 675 IAC 28-1-40 A COMPLETE LISTING OF ALL CODES AND STANDARDS ADOPTED BY THE STATE OF INDIANA INCLUDING ELEVATOR, ESCALTOR MANLIFTS HOIST CODES AND APPLICABLE NFPA STANDARDS THAT APPLY IS AVAILABLE AT:http:/AN .in.gov/dhs/2490.htm. ALL DESIGN CONSULTANTS, CONTRACTORS, SUBCONTRACTORS, AND SUPPLIERS ON THE PROJECT SHALL PROVIDE ALL WORK IN MATERIALS IN COMPLIANCE WITH ALL APPLICABLE CODES WHETHER OR NOT THEY ARE SPECIFICALLY REFERENCED IN THESE DOCUMENTS AND ARE RESPONSIBLE TO VISIT THIS W EBSITE TO ASSURE CURRENCY FOR THEIR PORTION OF THE WORK. v GENERAL CONSTRUCTION NOTES THESE NOTES APPLY TO ALL CONSTRUCTION DOCUMENTS, AND TO ALL CONTRACTORS AND/OR SUBCONTRACTORS THAT PARTICIPATE IN ANY FORM ON THIS PROJECT ALL WORK BY ALL TRADES, CONTRACTORS & SUBCONTRACTORS SHALL BE IN ACCORDANCE WITH STATE AND LOCAL CODES & REGULATIONS. ALL WORK SHALL BE CARRIED OUT IN STRICT COMPLIANCE WITH OSHARULESAND REGULATIONS. DESIGNTBUILDERAND EACH TRADE SHALL LAYOUT AND MARK ALL WALLS AND OPENINGS AND TRADE APPROPRIATE WORK PRIOR TO CONSTRUCTION. ANY DISCREPANCY SHALL BE REPORTED TO THE DESIGN/BUILDER IMMEDIATELY FOR RESOLUTION. SUBCONTRACTORS SHALL PROVIDE ALL NECESSARY PERMITS AND FEES REQUIRED TO COMPLETE THE PROJECT SCOPE FOR THEIR RESPECTIVE r DISCIPLINES/DESIGN/BUILDER SHALL PROVIDE BUILDING PERMIT AND FEES. 4 ALL DIMENSIONS ARE FROM FACE OF STUD/MASONRY/ OR OTHER CORE MATERIAL UNLESS NOTED OTHERWISE ALL SUBCONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS RELATIVE TO THE PROJECT AS ILLUSTRATED. ANY $ CONFLICTS OR DISCREPANCIES SHALL BE REPORTED TO THE DESIGN/BUILDER IMMEDIATELY FOR RESOLUTION. WHERE MOUNTING HEIGHTS ARE NOT INDICATED, MOUNT INDIVIDUAL UNITS OF WORK AT RECOMMENDED STANDARD HANDICAP 6 ACCESSIBILITY HEIGHTS FOR THE PARTICULAR WORK INDICATED. REFER QUESTIONABLE MOUNTING HEIGHTS TO THE DESIGNMUILDER FOR A FINAL DECISION. ALL NEW PARTITIONS SHALL BE CONSTRUCTED AS PER WALL TYPE AND SHALL BE CARRIED TO THE STRUCTURE ABOVE UNLESS INDICATED OTHERWISE. PREPARE ALL SURFACES FOR INDICATED FINISHES. DO NOT SCALE $� DRAWINGS. REFERENCE RELATED ELECTRICAL, MECHANICAL, AND PLUMBING DOCUMENTS 9 FOR NEW CONSTRUCTION ALL SUBCONTRACTORS ARE ENTIRELY RESPONSIBLE FOR COORDINATING THE LOCATIONS AND SPECIFIC REQUIREMENTS FOR MECHANICAL 1O ELECTRICAL, PLUMBING, AND OTHER EQUIPMENT WHICH THEY ARE PROVIDING AND/OR INSTALLING WITH THE DESIGN BUILDER PRIOR TO PROCEEDING W/ANY WORK. THE DESIGN/BUILDER AND THE SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR VISITING THE CONSTRUCTION SITE TO rill BECOME FAMILIAR WITH ALL EXISTING CONDITIONS WHICH AFFECT THEIR WORK. ANY CONFLICTS OR APPARENT DEFICIENCIES MUST BE SUBMITTED TO THE DESIGN/BUILDER IN WRITING IMMEDIATELY UPON DISCOVERY. WHERE NEW WORK IS INDICATED, READ REMOVAL OF EXISTING ITEMS SHALL 12 BE PERFORMED BY RESPECTIVE TRADE CONTRACTORS ALL CONSTRUCTION AREAS, REMOVAL TRAFFIC PATTERN AREAS AND ASSOCIATED WORK AREAS SHALL BE KEPT CLEAN OF DEBRIS ON A DAILY 13 BASIS BY THE CONTRACTOR($) RESPONSIBLE FOR THE DEBRIS. DUMPSTERS TO BE PROVIDED BY THE DESIGN BUILDER ANY AND ALL FURNITURE / EQUIPMENT / SPECIALTY EQUIPMENT / VENDING OR OTHER NON -AFFIXED ITEMS REPRESENTED IN THESE PLANS 14 ARE FOR REFERENCE ONLY, AND ARE PROVIDED AND INSTALLED BY THE OWNER UNLESS SPECIFICALLY NOTED OTHERWISE, SLIP TRACK SHALL BE INSTALLED AT ANY LOCATION WHERE WALLS NOTED TO EXTEND TO DECK AND ARE SUBJECT TO DEFLECTION 1$ INCLUDING BUT NOT UMITED TO: PEMS BUILDING FRAMES, STRUCTURAL STEEL ROOF/FLOOR FRAMING, ROOF DECKS -FOR FIRE RATED WALLS AFIRE RATED SLIP TRACK ASSEMBLY WITH MATCHING RATING SHALL BE PROVIDED 16 ANY AREAS WITH EXPOSED CONCRETE FLOORS SHALL HAVE ALL FLOOR JOINTS FULLY SEALED ALL SUBS SHALL PROVIDE, INSTALL AND COORDINATE ALL REQUIRED BLOCKING FOR EQUIPMENT, ACCESSORIES ETC. WITH THE JOBSITE 17 SUPERINTENDANT2 WEEKS MIN. PRIOR TO INSTALLATION ILL °tea ®® LL V V v FLU PAPER TOILET TOILET MIRROR APER TOWEL PAPER PAPER DISPENSER DISPENSER DISPENSER HOLDER TYPICAL TOILET ACCESSORIES MOUNTING HEIGHTS 60" MIN. CLEAR FINISHED DIMENSION Bn^ WATER CLOSET SIDE WALL 60" MIN. TOILET PARTITION WHERE OCCURS 1 1/2" DIA. GRAB BAR WITH 11/2" GAP FROM WALL TOILET PAPER MOUNTING V 3V AREA I IL, M 18" URINAL SCREEN WHERE OCCURS e a I kIE WATERCLOSET URINAL BACK WALL 24" SYMBOLS LEGEND DETAIL NUMBER � A1.1 Detail Callout SHEET NUMBER N INDICATES NORTH NAME OF DRAWING REFERENCE PLAN NUMBER OF DETAIL ON SHEET 1 Ire" = SCALE OF DRAWING NAME OF FLOOR OR LEVEL ELEVATION OF LEVEL 12-0 DETAIL NUMBER A1.1 Section Callout SHEET NUMBER DIRECTION OF SECTION FIRE PROTECTION WHEN FIRE SUPPRESSION IS PROVIDED, ALL SPRINKLER HEADS IN DRYWALL CEILINGS SHALL BE CONCEALED HEAD TYPE. FINISH TO BE SUBMITTED TO ARCHITECT FOR APPROVAL. PER SCOPE LETTER -ALL FIRE SPRINKLER AND ALARM SYSTEMS BY BRANCH CONTRACTOR COUNTER WHERE OCCURS 4 � 15"MIN. ACCESSIBL E SINK BOWL 61/2" DEEP rc 0 e a O _ z ry g DEESE n0 WASTE LAVATORY OR KITCHEN OR BREAK VANITY SINK ROOM SINKS TYPICAL PLUMBING FIXTURES AND ACCESSORIES MOUNTING HEIGHTS n Typical Accessible Heights 0 _ U at z �F� a � ens � o /y� 00 cn � w o mar es z �?- O 5 0 a O U N C IE J= a) a/ C 0 .N rn E E 0 a U N J °1 U t j o J �° 8 O LJJ =1 QN d y0 3 aV m 0- m P /^� LL mN 6�d E N D LL 6 CUJ `NU 06/03/2019 Rev 1 - General Clanfcations MJER STATUS: FOR CONSTRUCTION - REVISION #1 PROJECT x: vROJECI6SUE Dw1E 19149 N 90508 WN BT: REVIEWED Br. ATD NLM SHEET TITLE GENERAL NOTES AND PROJECT INFORMATION RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Calnlel �PAGIO DATE: 06/27/19 HERETINWEIRT1.1