HomeMy WebLinkAboutTLR-004 ENERGYIECC 2009 Performance Compliance
Property
14409 TALLYN WAY
CARMEL, IN 46074
Model: LELAND(WC)
Community: TALLYNS RIDGE 4
TLRO04 (AS DESIGNED)
TALLYNS RIDGE 4
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,498
S207
S186
$1,891
S1,334
SO
$3,225
Requirements
C-M,
Energy Solutions
As Designed
51,407
S206
S185
$1,798
S1,334
SO
$3,132
C4405.3 Performance-based compliance passes by 4.9%
402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 4.9%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date:
411119 at 9:50 AM
Ekotrope RATER - Version 3.1.0.2142
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
14409 TALLYN WAY
CARMEL, IN 46074
Builder: FISCHER HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-10
Framed Floor R-30
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-6.0, Return R-6.0
Duct Leakage to Outside 280.0 CFM @ 25Pa
Total Duct Leakage 448.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 96.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.72 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 411119 at 9:50 AM
Ekotrope RATER - Version 3.1.0.2142
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
14409 TALLYN WAY TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
Model: LELAND(WC)
Community: TALLYNS RIDGE 4 Builder
FISCHER HOMES
TLRO04 (AS DESIGNED)
TALLYNS RIDGE
General Building Information
Conditioned Area (sq ft) 5,306
Conditioned Volume (cubic ft) 48,624
Insulated Shell Area (sq ft) 9,844
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT (1,898 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (3 59 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 179, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 10.00
Fully insulated (top to bottom)
E[ Name: CONDIGAR (Exterior Perimeter [ft]: 42, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 10.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CON DIAM B (1,961 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (324 s.f.)
R-0.41 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property organization
14409 TALLYN WAY TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
Model: LELAND(WC)
Community: TALLYNS RIDGE 4 Builder
FISCHER HOMES
TLRO04 (AS DESIGNED)
TALLYNS RIDGE 4
Name: CONDIGAR (378 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDfATTIC (550 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
Name: RIM CONDIAMB (179 s.f.)
R: 15.414
Name: BAND COND/AMB (54 s.f.)
R: 15.414
El Name: CONDIGAR (42 s.f.)
R: 15.414
Name: CONDIATTIC (57 s.f.)
R: 15.414
Roof
El Name: SECOND (2,274 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
J --G U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
Glazing
2
Energy Code Inspection Checklist
Property
C-MEnergy Solutions
Organization inspection Status
14409 TALLYN WAY
TSI Energy Solutions Results are projected
CARMEL, IN 46074
Devin Sielschott
Model: LELAND(WC)
Community: TALLYNS RIDGE 4
Builder
FISCHER HOMES
TLR004 (AS DESIGNED)
TALLYNS RIDGE 4
E] Name: FRONT (140 s.f.),
U:0.310, SHGC: 0.28, Orientation: EAST
E] Name: BACK (121 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
El Name: BACK 2X6 (106 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
El Name: LEFT SIDE (8 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH
El Name: SLIDER (40 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH
El Name: RIGHT (47 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH
11 Name: BACK BSMT (20 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 96.1 AFUE
El Air conditioner • Electric • 100% Cooling Load @ 13 SEER
El Water Heating • Natural Gas • 100% Hot Water Load @ 0.72 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 4,052 CFM50 (5.00 AC H50) or less at final blower -door test.
3
Energy Code Inspection Checklist
Property
14409 TALLYN WAY
CARMEL, IN 46074
Model: LELAND(WC)
Community: TALLYNS RIDGE 4
TLRO04 (AS DESIGNED)
TALLYNS RIDGE
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Infiltration Requirements for IECC in Climate Zone 5
Inspection Status
Results are projected
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
Entirely within conditioned space
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 280.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 448.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
14409 TALLYN WAY
TSI Energy Solutions Results are projected
CARMEL, IN 46074
Devin Sielschott
Model: LELAND[WC]
Community: TALLYNS RIDGE d
Builder
Perimeter Location
FISCHER HOMES
TLRO04 [AS DESIGNED]
TALLYNS RIDGE 4
179 Exposed Exterior
Generakuilding Information
CONDIGAR R-10 Draped, Oft
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
5;306
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu. ft.]
48;624
Total Units in Building
1
Residence Type
Single family detached
Model
LELAND(WC)
Community
TALLYNS RIDGE 4
Climate Zone
5A
Basement Wall
d6
Name Library Type
Height Above Grade Depth Below Grade
Perimeter Location
Enclosing
CONDIAMB R-10 Draped, Full
1 7
179 Exposed Exterior
Conditioned Space
CONDIGAR R-10 Draped, Oft
1 7
42 Exposed Exterior
Conditioned Space
Basement Wall Library List
Name Feet From Wall Tap To
Insulation
Feet From Wall Top Tb Insulation
Is Fully Insulated Effective Insulation R -value
Top
Bottom
R-10 Draped, 4f[
0
4
No
10.00
R-10 Draped, Full
NIA
NIA
Yes
10.00
Name Library Type
Perimeter
Floor Grade Carpet R
Exposed Surface Area Location Enclosing
Masonry Area
33MT Uninsulated
197
Below Grade ❑
0 1,898.0 sq. R. Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Type
Slab Completely Underslab Insulation
Perimeter Insu}ation Perimeter Insulation R
Effective R -value
Insulated. Width [ft]
Depth [ft] Value
Uninsulated Wood Frame I Other
No 0
D D
0.00
1
Building Summary
Property
Organization
14409 TALLYN WAY
TSI Energy Solutions
CARMEL, IN 46074
Devin Sielschott
Model: LELAND[WC]
Medium
Community: TALLYNS RIDGE 4
Builder
CONDIAMB 2X6
FISCHER HOMES
TLRO04 [AS DESIGNED]
324.0 sq. fl.
TALLYNS RIDGE 4
CONDIATTIC
Framed Floor
Name Library Type
Ca
OVER GARAGE R-30, GR1
Framed Floor Library List
Name
Effective R -value
R-30, GR1
27.493
Rim Joist
Name
BAND CONDIAMB
CONDIATTIC
C O N DIGAR
RIM CONDIAMB
Rim Joist Library List
Name
G1 R-19, OSB
C-M
Energy Solutions
Inspection Status
Results are projected
e Surface Area Location
1.23 Above Grade 359.0 sq. ft Unconditioned, attached
garage
G1 R-19, OSB 54.0 sq. ft. Exposed Exterior
G1 R-19, OSB 57.0 sq. 11 Attic
G1 R-19, OSB 42.0 sq. ft. Unconditioned, attached garage
G1 R-19, OSB 179.0 sq. ft. Exposed Exterior
15.414
ii
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-15 BATT, T- PLY
Medium
1.961.0 sq. fl.
Exposed Exterior
CONDIAMB 2X6
G1 R-19 BATT, T -PLY
Medium
324.0 sq. fl.
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, T-PLYMedium
550.0 sq. ft.
Attic
2
Building Summary
Property
14409 TALLYN WAY
CARMEL, IN 46074
Model: LELAND[WC]
Community: TALLYNS RIDGE 4
TLRO04 [AS DESIGNED]
TALLYNS RIDGE 4
Name
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Library Type
Inspection Status
Results are projected
Surface Calor
Surface Area
C-MEnergy Solutions
Location
CONDIGAR G1 R-15 Gar Walls
Medium
378.0 sq. ft.
Unconditioned, attached garage
Wall Library List
Name
Effective R -value
G1 R-15 BATT, T -PLY
12.842
G1 R-15 Gar Walls
11.972
G1 R-19 BATT, T -PLY
17278
Glazing
Name Library Type Wall
Assignment Basement Wall
Assignment
Overhang Depth Overhang Ft
Top
To Overhang Ft To
Bottom
Orientation
Surface Area
BACK U-.31, SHGC-28
CONDIAMB
0
0 0
West
121.0 sq. ft.
BACK 2X6 U-.31, SHGC-.28 CONDIAMB 2X6
0
0 0
West
106.0 sq. ft.
BACK BSMT U-.31, SHGG28
CONDIAMB
0
0 ❑
West
20.0 sq. ft
FRONT U-.31, SHGG28
CONDIAMB
0
0 ❑
East
140.0 sq. ft.
LEFT SIDE U-.31, SHGG28
CONDIAMB
0
0 0
South
B.0 sq. ft.
RIGHT U-.31, SHGG28
CONDIAMB
0
0 0
North
47.0 sq. R
SLIDER U-.31, SHGG28
CONDIAMB
0
0 0
South
40.0 sq. fl-
tGlazing
GlazingLibrary List
Name
Shg c
U -factor
U-.31, SHGC-28
028
0.310
3
Building Summary
Property
14409 TALLYN WAY
CARMEL, IN 46074
Model: LELAND[WC]
Community: TALLYNS RIDGE 4
TLRO04 [AS DESIGNED]
TALLYNS RIDGE 4
Skyligh
Skylight Library List
Organization
TSI Energy Solutions
Devin Sielschoft
Builder
FISCHER HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque Door
Name Library Type Wall Assignment Basement Wall
Emittance Solar Surface Color
Surface Area
Location
Assignment
Ab sorpta nce
FRONT Fiberglass/Steel CONDIAMB
0.9 0.75 Medium
20.0 sq. ft
Exposed Exterior
Door
GARAGE Fiberglass/Steel CONDIGAR
0.9 0.75 Medium
18.0 sq- ft
Exposed Exterior
Door
Opaque Door Library List
Name
Fiberglass/Steel Door
Roof Insulation JMA
Name Library Typ
SECOND R-38 Blown. GR1
0.182
krea Clay or Concrete Root
P.f.] Tiles
2,274 No
Roof Insulation Library List
Name Has Radiant Barrier Effective R -value
'•3 �- -I :a l No 38268
n
Medium 2,274-0 sq. ft Attic
4
Building Summary
Property
Organization
C-MEnergy Solutions
Inspection Status
14409 TALLYN WAY
TSI Energy Solutions
Results are projected
CARMEL, IN 46074
Devin Sielschott
Model: LELAND[WC]
Community: TALLYNS RIDGE d
Builder
FISCHER HOMES
TLRO04 [AS DESIGNED]
TALLYNS RIDGE 4
Whole House Infiltration
Infiltration
Measurement Type
Shelter Class
5 ACH at 50 Pa
Blower -door tested
4
Mechanical Ventilation
Lighting
% Interior Fitiorescent % Interior LED Lighting % Exteriar Fluorescent °% Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
❑ ❑ a ❑ ❑ o
Onsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation
Solar Generation Library List
Building Summary
Property
Organization
Inspection Status
14409 TALLYN WAY
TSI Energy Solutions
Results are projected
CARMEL, IN 46074
Devin Sielschott
Motor Type
Model: LELAND(WC)
Heating Efficiency
96.1 AFUE
Community: TALLYNS RIDGE d
Builder
Use default EAE
No
FISCHER HOMES
754
TLRO04 [AS DESIGNED]
Fuel Type
TALLYNS RIDGE 4
Distribution Type
Hydronic Delivery
Conditioning Equipment
0.72 Energy Factor
Tank Capacity (gal.)
Name
Library Type
Heating Percent Load Co(
Air conditioner
0.80
quipment Type: GSX130421A
GSX130421A
0%
I Fuel -fired air GMSS960803BN 100%
distribution
IWater Heating GPVL-50-200 0%
1
Equipment Type: GMSS960803BN
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
96.1 AFUE
Heating Capacity [kBtulh]
77
Use default EAE
No
EAE [kWh]
754
Equipment Type: GPVL-50-200
Fuel Type
Natural Gas
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.72 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
40
Recovery Efficiency
0.80
quipment Type: GSX130421A
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
40
C-M,
Energy Solutions
g Percent Load Hot Water
100% 0%
0% 0%
0% 100%
6
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
14409 TALLYN WAY
TSI Energy Solutions Results are projected
CARMEL, IN 46074
Devin Sielschott
Model: LELAND[WC]
Community: TALLYNS RIDGE d
Builder
FISCHER HOMES
TLRO04 [AS DESIGNED]
TALLYNS RIDGE 4
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
5306
# Return Grilles
4
Supply Duct R Value
6
Return Duct R Value
6
Supply Duct Area [sq. ft.]
1516.86
Return Duct Area [sq. ft_]
1123.6
Duct Leakage to Outdoors (CFM25)
2.86
Total Leakage
448
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
100
Percent Return Area
166
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rCeiling Fan
Has Ceiling Fan No
Cfm Per Watt 101
7
Building Summary
Property
14409 TALLYN WAY
CARMEL, IN 46074
Model: LELAND[WC]
Community: TALLYNS RIDGE 4
TLRO04 [AS DESIGNED]
TALLYNS RIDGE 4
Water Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
FISCHER HOMES
Standard
No
75
No
No
20
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�