Loading...
HomeMy WebLinkAboutA000.4SCALE:LEFT ELEV - SLAB - OPT. SUNROOM1/8" = 1'-0" T.O. FLOOR (W/ LOFT) T.O. PLATE (W/ LOFT) \A1;8'-1{\H0.750000x;\S1#8;}"T.O. PLATE T.O. FIRST FLOOR \A1;7'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL. WINDOW HDR. HGT. WINDOW HDR. HGT.127125 SCALE:FLOOR PLAN - OPT. SUNROOM - 4" EXTERIOR WALLS1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN OPT. MASONRY WRAP, PER SPEC OWNER'S SUITE*9'-0" CLG. OPT 8" TRAY (IN TRUSS) CAFE*9'-0" CLG. \A1;20'-0"\A1;20'-4{\H0.750000x;\S1#2;}"\A1;13'-7{\H0.750000x;\S1#2;}"\A1;54'-0" - OVERALL \A1;6'-0" SUNROOM*9'-0" CLG. \A1;10'-0"\A1;10'-4{\H0.750000x;\S1#2;}" 3/0 (3) 3060 SH \A1;3'-2" \A1;2'-10" 12" DROP HDR.\A1;6'-7{\H0.750000x;\S1#2;}"\A1;10'-0"\A1;3'-8{\H0.750000x;\S1#2;}" SS OPT. LIGHT/FAN\PBRACE AND PRE-WIRE S RR R R RR \A1;6'-0" \A1;2'-10"\A1;4'-0"\A1;6'-0"\A1;6'-0{\H0.750000x;\S1#4;}" 3S 3S WP/GFI+66" A.F.F.S \pxql;3'x3' CONC.\PSTOOP OPT. 13'-8"x12'-0"\PCONC. PATIO\P(OPT. DECK w/ BASEMENT) 2 3060 SH (TEMP)4 SCALE:REAR ELEV - SLAB - OPT. SUNROOM1/8" = 1'-0"- T.O. FLOOR (W/ LOFT) T.O. PLATE (W/ LOFT) \A1;8'-1{\H0.750000x;\S1#8;}" T.O. FIRST FLOOR T.O. PLATE OPT. MASONRY WAINSCOT ROOF SHINGLES, PER SPEC LINE OF ROOF AT\POPT. LOFT OPT. MASONRY FIRST FLOOR\A1;7'-2{\H0.750000x;\S7#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL. WINDOW HDR. HGT. WINDOW HDR. HGT. SCALE:RIGHT ELEV - SLAB - OPT. SUNROOM1/8" = 1'-0" 127125 SUNROOM (ADDITIONAL VENTING REQUIRED PER ELEVATION) ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 242 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.32 0.40 0.42 46.56 1 0 AT EAVE 0.48 0.40 0.49 53.44 0 7.00 TOTAL (MIN)0.81 0.81 0.91 100.00 3 HIGH - RIDGE VENT 0.32 0.40 0.50 50.70 0 0 4.00 AT EAVE 0.48 0.40 0.49 49.30 0 7.00 TOTAL (MIN)0.81 0.81 0.99 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE SCALE:ROOF PLAN - OPT. SUNROOM1/8" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN 5:127:12 (OPT. LOFT) \A1;1'-0"\PTYP.OPT. GUTTER AND DOWNSPOUTS ROOF AREASQ. FT."A"242 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2017 RICK STARKEY06/07/2013 GARAGE LEFT Croix 1993.301 -- 08/01/2017 PLOTTED: October 6, 2017 / Mark Muurisepp / 1993-CROIX-CZ-BAS2-OPTS.DWG A4 SR4S.1Opt. Sunroom - 4" Exterior WallsFloor and Utility PlansSlab Foundationmake 4 1/2" 04/22/19 William Hohlt