HomeMy WebLinkAboutA000.4SCALE:LEFT ELEV - SLAB - OPT. SUNROOM1/8" = 1'-0"
T.O. FLOOR (W/ LOFT)
T.O. PLATE (W/ LOFT)
\A1;8'-1{\H0.750000x;\S1#8;}"T.O. PLATE
T.O. FIRST FLOOR
\A1;7'-2{\H0.750000x;\S7#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL.
WINDOW HDR. HGT.
WINDOW HDR. HGT.127125 SCALE:FLOOR PLAN - OPT. SUNROOM - 4" EXTERIOR WALLS1/4" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
OPT. MASONRY WRAP, PER SPEC
OWNER'S SUITE*9'-0" CLG. OPT 8" TRAY (IN TRUSS)
CAFE*9'-0" CLG.
\A1;20'-0"\A1;20'-4{\H0.750000x;\S1#2;}"\A1;13'-7{\H0.750000x;\S1#2;}"\A1;54'-0" - OVERALL
\A1;6'-0"
SUNROOM*9'-0" CLG.
\A1;10'-0"\A1;10'-4{\H0.750000x;\S1#2;}"
3/0
(3) 3060 SH
\A1;3'-2"
\A1;2'-10"
12" DROP HDR.\A1;6'-7{\H0.750000x;\S1#2;}"\A1;10'-0"\A1;3'-8{\H0.750000x;\S1#2;}"
SS
OPT. LIGHT/FAN\PBRACE AND PRE-WIRE
S
RR R
R RR
\A1;6'-0"
\A1;2'-10"\A1;4'-0"\A1;6'-0"\A1;6'-0{\H0.750000x;\S1#4;}"
3S
3S
WP/GFI+66" A.F.F.S
\pxql;3'x3' CONC.\PSTOOP
OPT. 13'-8"x12'-0"\PCONC. PATIO\P(OPT. DECK w/ BASEMENT)
2
3060 SH (TEMP)4
SCALE:REAR ELEV - SLAB - OPT. SUNROOM1/8" = 1'-0"-
T.O. FLOOR (W/ LOFT)
T.O. PLATE (W/ LOFT)
\A1;8'-1{\H0.750000x;\S1#8;}"
T.O. FIRST FLOOR
T.O. PLATE
OPT. MASONRY WAINSCOT
ROOF SHINGLES, PER SPEC
LINE OF ROOF AT\POPT. LOFT
OPT. MASONRY FIRST FLOOR\A1;7'-2{\H0.750000x;\S7#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;}" \A1;8'-2{\H0.750000x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;}" @ OPT. 10' PL.
WINDOW HDR. HGT.
WINDOW HDR. HGT.
SCALE:RIGHT ELEV - SLAB - OPT. SUNROOM1/8" = 1'-0"
127125
SUNROOM (ADDITIONAL VENTING REQUIRED PER ELEVATION)
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 242 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.32 0.40 0.42 46.56 1 0
AT EAVE 0.48 0.40 0.49 53.44 0 7.00
TOTAL (MIN)0.81 0.81 0.91 100.00
3
HIGH -
RIDGE VENT 0.32 0.40 0.50 50.70 0 0 4.00
AT EAVE 0.48 0.40 0.49 49.30 0 7.00
TOTAL (MIN)0.81 0.81 0.99 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
SCALE:ROOF PLAN - OPT. SUNROOM1/8" = 1'-0"SEE BASE PLANS FOR INFORMATION NOT SHOWN
5:127:12 (OPT. LOFT)
\A1;1'-0"\PTYP.OPT. GUTTER AND DOWNSPOUTS
ROOF AREASQ. FT."A"242 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2017
RICK STARKEY06/07/2013
GARAGE LEFT
Croix
1993.301
--
08/01/2017
PLOTTED: October 6, 2017 / Mark Muurisepp / 1993-CROIX-CZ-BAS2-OPTS.DWG
A4
SR4S.1Opt. Sunroom - 4" Exterior WallsFloor and Utility PlansSlab Foundationmake 4 1/2"
04/22/19
William Hohlt