Loading...
HomeMy WebLinkAboutSHW 009 - Energy Certificate14461 CARLOW RUN CARMEL, IN 46074 Builder: PULTE HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-25.0, Return R-25.0 Duct Leakage to Outside 125.0 CFM @ 25Pa Total Duct Leakage 200.0 CFM @ 25Pa Heating Furnace • Natural Gas • 93 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Corrfim7ed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the ECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 412119 at 9:30 AM Ekotrope RATER - Version 3.1.0.2143 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.