Loading...
HomeMy WebLinkAboutLEGACY RIDGE 56 - LR56 (AS DESIGNED)IECC 2009 Performance Compliance Property 14360 ARNETT DR CARMEL, IN 46033 LR56 (AS DESIGNED) LEGACY RIDGE 56 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,728 $272 $398 $2,398 $932 $0 $3,330 Requirements C-M, Energy Solutions As Designed $1,560 $256 $398 $2,214 $932 $0 $3,'146 405.3 Performance-based compliance passes by 7.7% 402.4.1.2 Air Leakage Testing Air sealing is 5.06 ACH at 50 Pa. It must not exceed 7.013 ACH at 50 Pa 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor C4 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 7.7%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 2125119 at 3:02 PM Ekotrope RATER - Version 3.1.0.2117 IECC 2Q1)9 Performance compliance results calculated using Ekotrope's energy algorithm, which is a RESINET Accredited HERS Rating Tool. 14360 ARNETT DR CARMEL, IN 46033 LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31. SHGC: 0.32 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 288.0 CFM @ 25Pa Total Duct Leakage 384.0 CFM @ 25Pa Heating Furnace - Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 2125/19 at 3:02 PM Ekotrope RATER - Version 3.1.0.2117 No version of this software has been reviewed or approved by ICC or its affiliates_ The 20N International Energy Conservation Code is a registered trademark oft he International Code Council, Inc. ('ICC'). This software is a RESNETAccredited HERS Rating Tool. Energy Cade Inspection Checklist Property 14360 ARNETT DR CARMEL, IN 46033 LR56 (AS DESIGNED) LEGACY RIDGE 56 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 5,348 47,840 9,419 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (1,712 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor ]l Name: OVER GARAGE (402 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I ]l Name: OVER AMBIENT (14 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall El Name: CONDlAMB (Exterior Perimeter [ft]: 131; Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Name: CON DIGAR (Exterior Perimeter [ft]: 43, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall Name: CON DIAMB (2,367 s.f.) R-3 continuous insulation, R-13 cavity insulation 1 Insulation Grade: I Energy Cade Inspection Checklist Property Organization 14360 ARNETT DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR56 (AS DESIGNED) Builder LEGACY RIDGE 56 LENNAR HOMES Name: CON DIAM B 2X6 (270 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CON DIGAR (387 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CON DIATTIC (206 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade; I Rim Joist El Name: CDN DIAM B (270 s.f.) R: 13.575 Name: CON DIGAR (43 s.f.) R: 10.876 Name: CONDIATTIC (54 s.f.) R: 10.876 Roof 1� Name: SECOND (2,128 s.f.) 1--1 R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door 1� Name: FRONT (20 s.f.) 1--1 U: 0.182 El Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (132 s.f.), U: 0.310, SHGC: 0.29, Orientation: EAST C-M, Energy Solutions 2 Energy Cade Inspection Checklist C-M Energy Solutions Property Organization 14360 ARNETT DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status Results are projected LR56 (AS DESIGNED) Builder LEGACY RIDGE 56 LENNAR HOMES E] Name: BACK (174 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST E] Name: BACK 2X6 (77 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST Name: BACK 2X6 GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST E] Name: RIGHT SIDE (83 s.f.), U:0.310, SHGC: 0.32. Orientation: NORTH El Name: RIGHT SIDE BSMT (16 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH 1� Name: LEFT SIDE (59 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH El Name: LEFT SIDE BSMT (16 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment Fuel -fired air distribution (1) • Natural Gas • 100°1% Heating Load @ 95.5 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER Water Heating (3) - Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 3,987 CFM50 (5.00 ACH50) or less at final blower -door test. 3 Energy Cade Inspection Checklist Property 14360 ARNETT DR CARMEL, IN 46033 LR56 (AS DESIGNED) LEGACY RIDGE 56 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Infiltration Requirements for IECC in Climate Zone 5 Inspection Status Results are projected 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC. Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 288.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 384.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 1 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage {= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM251 100 sq ft CFA. 2015 Performance Path (Cost Compliance): CTSI Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary C-M Energy Solutions Property Organization 14360 ARNETT DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LR56 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 56 LEN NAR HOMES General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 5,348 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 47,840 Total Units in Building 1 Residence Type Single family detached Model 3500 Community LEGACY RIDGE 56 Climate Zone 5A Basement Wali Name Library type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 411 1 8 131 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 411 1 S 43 Exposed Exterior Conditioned Space Basement Wall Library Lis, Name Feet From Wall Top R-11 Draped, 411 4 No 11.09 Slab Name Library l]Ipe Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 174 Below Grade 0 a 1,712.9 sq. 11. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction type Slab Completelyx Underslab Insulation Perimeter Insulation Perimeter Insulation R R -value Insulated. Width [ft] Depth [ft] Value Uninsulated Wood Frame /Other No 0 0 o 0.00 1 Building Summary Property Organization 14360 ARNETT DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR56 (AS DESIGNED) Builder LEGACY RIDGE 56 LENNAR HOMES Framed Floor Name Library type Car OVER AMBIENT R-38, GRI OVER GARAGE R-38, GR1 Framed Floor Library List Name R•value R-38, GR1 33.825 Rim Joist Name Library Type CONDIAMB G1 R-13, R-3.0 COiND1ATTIC G1 R-13, OSB CONDIGAR G1 R-13, OSB Rim Joist Library List Name R -value G1 R-13, OSB I0 B76 G1 R-13, R-3.0 13.575 Name CONDIAMB :�ONDIAMB 2X6 Library type G1 R-13 BATT, R-3.0 G1 R-19, R-3.0 2X6 C-M, Energy Solutions Inspection Status Results are projected 1.23 Above Grade 14.0 sq. ft. Exposed Exterior 1.23 Above Grade 402.0 sq. R. Unconditioned, attached garage Surface Area Location 270.0 sq. ft. Exposed Exterior Surface Calor Medium 54.0 sq. ft. Attic 43.0 sq. ft. Unconditioned, attached garage Surface Area 2,367.0 sq. ft. 2700 so. it. Location Exposed Exterior Exposed Exterior 2 Building Summary Property Organization C-MEnergy Solutions 14360 ARNETT DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Inspection Status LR56 (AS DESIGNED) Builder Results are projected LEGACY RIDGE 56 LENNAR HOMES Name Library type Surface Color Surface Area Location CONDIATTIC G1 R-13 BATT, R-3.0 Medium 2060.sq. ft. Attic CONDIGAR G1 R-13 Gar Wall& Medium 387.0 sq. 11 Unconditioned, attached garage ■ Wall Library List Name R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.02X6 20.217 Glazing Name Library Type Wall Assignment Basement Wa}T Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK U-.31, SHGC-.32 CONDIAMB 0 0 0 West 174.0 sq. ft. BACK 2X6 U-.31, SHGC-.32 CON DIAMB 2X6 0 0 0 West 77.0 sq. 11 BACK 2X6 GD U-29, SHGC-.33 CON DIAMB 2X6 0 0 0 West 18.0 sq. ft. FRONT U-.31, SHGC-.29 CONDIAMB 0 0 0 East 132.0 sq. 11 LEFT SIDE U-.31, SHGC-.32 CONDIAMB 0 0 0 South 59.0 sq. 11 LEFT SIDE BSMT U-.31, SHGC-.32 CONDIAMB ❑ 0 0 South 16.0 sq. ft. RIGHT SIDE U-.31, SHGC-.32 CONDIAMB ❑ 0 0 North 83.0 sq. 11 RIGHT SIDE BSMT U-.31, SHGC-.32 CONDIAMB 0 0 0 North 16.0 sq. ft. 3 Building Summary Property 14360 ARNETT DR CARMEL, IN 46033 LR56 (AS DESIGNED) LEGACY RIDGE 56 Glazing Library List Name U-.29, SHGG.33 U-.31, SHGC-.29 U-.31. SHGC-.32 Skylight Skylight Library List Organization TSI Energy Solutions Ma tthew Ti m mon s Builder LENNAR HOMES D.33 D.29 Inspection Status Results are pmjected 0.296 0.310 0.32 0.310 C-M, Energy Solutions Opaque Doo Name Library Type Wall Assignment FRONT Steel Door CONDlAMB Basement Waii Assignment Emittance 0.9 Solar Surface Absorptan ce 0.75 Color Surtace Area Medium 20.0 sq. ft. Location Exposed Exterior GARAGE Steel Door CONDlGAR 0.9 0.75 Medium 18.0 sq. ft. Exposed Exterior Opaque Door Library List 1K Name U -facto r Steel Door 0.182 Roof Insulation Name Library type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location P.f.j Tiles SECOND R-38 Blown, GR1 2,128 No Medium 2,128.9 sq. IL Attic 2 Building Summary Property Organization 14360 ARNETT DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR56 (AS DESIGNED) Builder LEGACY RIDGE 56 LENNAR HOMES Roof Insulation Library List _ Name Has Radiant Barriei R-38 Blown, GR1 No use Infiltratio 5 ACH at 50 Pa Mechanical Ventilation Liahtina 0 Onsite Generation Blower -door tested 100 Onsite Generation Library List None Present Solar Generation None Present 0 Inspection Status Results are projected 38268 4 100 C-M, Energy Solutions 0 100 ,:I Building Summary Property 14360 ARNETT DR CARMEL, IN 46033 LR56 (AS DESIGNED) LEGACY RIDGE 56 Solar Generation Library List Conditioning Equipment i Name Organization TSI Energy Solutions Ma tthew Ti m mon s Builder LENNAR HOMES None Pre 9 Inspection Status Results are projected C-M, Energy Solutions Air conditioner (2) CA13NA042 0% 100% 0% Fuel -fired air distribution (1) Water Heating (3) 9155A48080517 RE350" quipment Type: 915SA48080511M Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 946 Equipment Type: CA13NA042 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 100% 0% D% o% 100% A Building Summary Property Organization 14360 ARNETT DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons LR56 (AS DESIGNED) Builder LEGACY RIDGE 56 LENNAR HOMES Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution {1} Cooling Equipment Air conditioner (2) Sq. Feet Served 4836 # Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 20 Supply Duct Area [sq. ft.] 1305.72 Return Duct Area [sq. ft] 967.2 Duct Leakage to Outdoors (CFM25) 288 Total Leakage 384 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 70 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 30 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Inspection Status Results are projected Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 100 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No C-M, Energy Solutions Building Summary Property 14360 ARNETT DR CARMEL, IN 46033 LR56 (AS DESIGNED) LEGACY RIDGE 56 Clothes Dryer Fuel Type Cef Field Utilization Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization TSI Energy Solutions Ma tthew Ti m mon s Builder LENNAR HOMES Electric 2.617 Timer Controls irw 704 kWh/Year $0.08lkWh $23.00 $0.58frherm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year Inspection Status Results are projected 7 C-M, Energy Solutions