HomeMy WebLinkAboutCLAY CORNER 24 - CC024 (AS DESIGNED)IECC 2009 Performance Compliance
Property
1558 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (C)
Community: CLAY CORNER 24
CCO24 (AS DESIGNED)
CLAY CORNER 24
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
51,299
S217
S385
$1,901
S670
SO
$2,571
Requirements
C-M,
Energy Solutions
As Designed
S1,152
S178
S385
$1,715
S670
So
$2,386
C4405.3 Performance-based compliance passes by 9.8%
402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 9.8%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
3113119 at 11:03 AM
Ekotrope RATER - Version 3.1.0.2130
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
�J PTO Pi
1558 JENSEN DR
CARMEL, IN 46032
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 5 ACH50
Window U -Value: 0.33, SHGC: 0.28
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 150.0 CFM @ 25Pa
Total Duct Leakage 240.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 3113119 at 11:03 AM
Ekotrope RATER - Version 3.1.0.2130
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
1558 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON (C)
Community: CLAY CORNER 24 Builder
LENNAR HOMES
CCO24 (AS DESIGNED)
CLAY CORNER 24
General Building Information
Conditioned Area (sq ft) 3,074
Conditioned Volume (cubic ft) 26,731
Insulated Shell Area (sq ft) 7,442
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (2,139 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB 2X4 (2,413 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (408 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Energy Code Inspection Checklist
Property organization
1558 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON (C)
Community: CLAY CORNER 24 Builder
LENNAR HOMES
CCO24 (AS DESIGNED)
CLAY CORNER 24
El Name: BAND CONDIAMB (67 s.f.)
R: 13.575
Roof
Name: CONDIATTIC (64 s.f.)
R: 13.575
Name: SECOND (2,139 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.182
Name: GARAGE (18 s.f. )
U: 0.182
Glazing
Inspection Status
Results are projected
11 Name: FRONT (120 s.f.), U:0.330, SHGC: 0.28, Orientation: SOUTH
El Name: SACK (90 s.f.), U:0.330, SHGC: 0.28, Orientation: NORTH
Name: LEFT SIDE (93 s.f.), U:0.330, SHGC: 0.28, Orientation: WEST
El Name: LEFT SIDE GD (20 s.f.), U:0.330, SHGC: 0.28, Orientation: WEST
E] Name: BSMT (32 s.f.), U:0.330, SHGC: 0.28, Orientation: WEST
E] Name: RIGHT SIDE (73 s.f.), U:0.330, SHGC: 0.28, Orientation: EAST
E] Name: BSMT (16 s.f.), U:0.330, SHGC: 0.28, Orientation: EAST
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property
1558 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (C)
Community: CLAY CORNER 24
CCO24 (AS DESIGNED)
CLAY CORNER 24
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE
M Air conditioner • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 2,228 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 150.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 240.0 CFM @ 25Pa
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property
1558 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (C)
Community: CLAY CORNER 24
CCO24 (AS DESIGNED)
CLAY CORNER 24
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
5N5
4
Building Summary
Property
Organization Inspection Status
1558 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON [C]
Yes
Community: CLAY CORNER 24
Builder
Total Units in Building
LENNAR HOMES
CCO24 [AS DESIGNED]
Single family detached
CLAY CORNER 24
PENNINGTON (C)
General Building Information
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
3;074
Unconditioned, attached garage?
Yes
Conditioned Volume [cu. ft.]
26;731
Total Units in Building
1
Residence Type
Single family detached
Model
PENNINGTON (C)
Community
CLAY CORNER 24
Climate Zone
5A
Basement Wall
None Present
Basement Wall Library List
None Present
Slab
C-M,
Energy Solutions
1P
Exposed Surface Area Location Enclosing
Masonry Area
SLAB R-10, 2'down
217 On Grade
0
0 2,139.0 sq. ft. Exposed Exterior
Conditioned
Space
Slab Library List "s
w RP
1qr
Name Wall Construction Type
Slap Completely Underslalb
Insulation
Perimeter Insulation Perfineterinsufation R
R -value
Insulated.
Width [ft]
Depth [Pt] Value
IR-10, 2'down Wood Frame / Other
No
0
2 1 D
0.00
Framed Floor Im
None Present
1
Building Summary
Property
Organization
1558 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON [C]
Medium
Community: CLAY CORNER 24
Builder
CONDIATTIC
LENNAR HOMES
CCO24 [AS DESIGNED]
408.0 sq. ft.
CLAY CORNER 24
CONDIGAR
Framed Floor Library
Rim Joist
Name
BAND CONDIAMB
CONDIATTIC
Rim Joist Library List
Name
G1 R-13. R-3.0
C-M
Energy Solutions
Inspection Status
Results are projected
Surface Area Location
67.0 sq. ft. Exposed Exterior
G1 R-13, R-3.0 64.0 sq. ft. Attic
13.575
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB 2X4
G1 R-13 BATT, R-3 -0
Medium
2,413.0 sq. ft.
Exposed Exterior
CONDIATTIC
G1 R-13 BATT, R-3-0
Medium
408.0 sq. ft.
Attic
CONDIGAR
G1 R-13 Gar Walls
Medium
180.0 sq. ft.
Unconditioned, attached garage
Wall Library List
Name
R value
G1 R-13 BATT, R-3.0
15.12
IG1 R-13 Gar Walls
11.141
2
Building Summary
Property Organization
1558 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON [C]
Community: CLAY CORNER 24 Builder
LENNAR HOMES
CCO24 [AS DESIGNED]
CLAY CORNER 24
Glazing
Inspection Status
Results are projected
C-MEnergy Solutions
Name Library Type Wall Assignment Basement Wall Overhang Depth
Overhang lPt Te
Overhang Pt Te
Orientation
Surface Area
Assignment
Emittance Solar Surface Color
Top
Bottom
Absorptance
BACK U-.33, SHGG28 CONDIAMB 2X4
0
0
❑
North
90.0 sq. ft
BSMT U-.33, SHGG28
0
0
❑
West
32.0 sq. fL
BSMT U-.33, SHGG28 CONDIAMB 2X4
0
0
❑
East
16.0 sq. ft
FRONT U-.33, SHGG28 CONDIAMB 2X4
0
0
❑
South
1200.sq. R.
LEFT SIDE U-.33, SHGG28 CONDIAMB 2X4
0
0
0
West
93.0 sq. ft
LEFT SIDE GD U-.33, SHGG28 CONDIAMB 2704
0
0
0
West
20.0 sq. R
RIGHT SIDE U-.33, SHGG28 CONDIAMB 2X4
0
0
❑
East
73.0 sq. ft
Glazing Library List
Name Shgc
U factor
U-.33, SHGC-28 0.28
0.330
Skylight
None Present
Skylight Library List
None Present
Opaque Danr
iiiiiiifi�E,
Name Library Type Wal} Assignment Basement Wall
Emittance Solar Surface Color
SurfaceArea Location
Assignment
Absorptance
FRONT Fiberglass Door CONDIAMB 2X4
24.0 sq_ ft Exposed Exterior
0.9 0.75 Medium
GARAGE Fiberglass Door CONDIGAR
18.0 sq_ ft Exposed Exterior
0.9 0.75 Medium
3
Building Summary
Property
1558 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [C]
Community: CLAY CORNER 24
CCO24 [AS DESIGNED]
CLAY CORNER 24
Opaque Door Library List
Name
Fiberglass Door
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
V11.1 Tiles
SECOND R-38 Blown, GRI 2,139 No Medium 2,139-0 sq. ft Attic
Roof Insulation Library List
Name Has Radiant Barrier RAalue
'•0 ? :a l No 38268
Whole House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation M
None Present
1
Lighting
% Interior Fluorescent % Interior LED Lighting % Exter
Lighting
❑ 100
Shelter Class
4
or Fluorescent % Exterior LED Lighting % Garage Fluorescent
Lighting Lighting
0 700 ❑ 100
4
Building Summary
Library Type
Property
C-MEnergy Solutions
Organization Inspection Status
1558 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON [C]
0%
Community: CLAY CORNER 24
Builder
100%
LENNAR HOMES
CCO24 [AS DESIGNED]
distribution
CLAY CORNER 24
Onsite Generation
Onsite Generation Library List I
None
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name
Library Type
Heating Percent Load
Cooling Percent Lead
Hot Water Percent Load
Air conditioner
CA13NA042
0%
1OD%
0%
Fuel -fired air
9155A42060917
100%
0%
0%
distribution
Water Heating
RE350"
0%
0%
100%
Equipment Type: 915SA42060S17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 95.5 AFUE
Heating Capacity [kBtulh] 58
Use default EAE No
EAE [kWh] 636
5
Building Summary
Property
Organization Inspection Status
1558 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON [C]
13 SEER
Community: CLAY CORNER 24
Builder
■
LENNAR HOMES
CCO24 [AS DESIGNED]
CLAY CORNER 24
Electric
Equipment Type: CA13NA042
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
40
■
Equipment Type: RE350*
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
C-M,
Energy Solutions
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
1558 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON [C]
Community: CLAY CORNER 24
Builder
LENNAR HOMES
CCO24 [AS DESIGNED]
CLAY CORNER 24
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
3674
# Return Grilles
3
Supply Duct R Value
10
Return Duct R Value
10
Supply Duct Area [sq. ft.]
829.98
Return Duct Area [sq. ft_]
461.1
Duct Leakage to Outdoors (CFM25)
156
Total Leakage
246
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rCeiling Fan W
Has Ceiling Fan No
Cfm Per Watt 101
7
Building Summary
Property
1558 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [C]
Community: CLAY CORNER 24
CCO24 [AS DESIGNED]
CLAY CORNER 24
Water Distribution MM
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
r5N5
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Standard
No
65
No
No
30
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
C-M,
Energy Solutions
,�