Loading...
HomeMy WebLinkAboutA000.3SCALE:FRONT ELEVATION1/4" = 1'-0"- \A1;3'-6"\A1;MIN. \A1;7'-2{\H0.75x;\S1#2;}"\A1;8'-1{\H0.75x;\S1#8;}" \A1;8'-1{\H0.75x;\S1#8;}"\A1;9'-1{\H0.75x;\S1#8;}" \A1;7'-11{\H0.75x;\S1#2;}" \A1;11'-1{\H0.750000x;\S1#8;}"\PPLATE HT. 7:12 7:12 \A1;9'-0"\PPLATE HT. 8:12 \A1;11'-1{\H0.750000x;\S1#8;}"\PPLATE HT. \A1;2'-5{\H0.750000x;\S1#2;}" 7:12 2030\PFX \A1;8'-1{\H0.750000x;\S1#8;}" \A1;2'-0" \A1;3'-6" \A1;3'-6" \A1;3'-6" \A1;3'-1"\A1;3'-1" \A1;3'-6"7:12 14:12 ROOF SHINGLES, PER SPECFYPON #LV12X24 OR APPROVED EQUALTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION 8" FASCIA, PER SPEC SOLDIER COURSE, PER SPEC STONE SILL, PER SPECSTONE VENEER, PER SPEC BRICK VENEER, PER SPEC 1214 1214 12141x3 OVER 8" RAKE BOARD, PER SPEC4" FRIEZE, PER SPEC BRICK VENEER, PER SPECSTONE SILL, PER SPECSTONE VENEER, PER SPEC 8" TRIM BOARD, PER SPEC 12144" TRIM BOARD (TYP.), PER SPEC 121412141214 1214 1214 1214 TOP OF FOOTING 4" BATTENS @ 24" O.C. OVER HARDIE PANEL (SMOOTH), PER SPEC 4" BATTENS @ 24" O.C. OVER HARDIE PANEL (SMOOTH), PER SPEC 8" FRIEZE, PER SPEC \A1;3'-1" 7:12 SCALE:ROOF PLAN1/8" = 1'-0"- OPT. GUTTER AND DOWNSPOUTS \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION, TYP. "A"3226ROOF AREA:SQ. FT. \pxi-4,l4,ql,t3;OPT. POT VENTS "B"59ROOF AREA:SQ. FT. 14:12 7:12 14:1214:12 7:12 7:12 7:1214:12 14:12 14:1214:12 14:1214:12 7:12 14:12 14:1214:12 14:12 7:12 \A1;22'-0{\H0.750000x;\S3#4;}" \pxi-4,l4,ql,t3;POT VENT 14:12\A1;20'-0"7:12 7:12 8:12 14:1214:12 14:12 14:1214:12 14:12 \A1;6'-0{\H0.750000x;\S1#2;}" \A1;2'-11" \A1;7'-1" \A1;2'-11" 14:1214:12 \A1;12'-0" \A1;24'-0" \A1;6'-0" \A1;8'-0" SCALE:LEFT ELEVATION1/8" = 1'-0"- \A1;2'-6" \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}"\A1;3'-6"\A1;MIN. TOP OF PLATEROOF SHINGLES, PER SPECWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING 8" FASCIA, PER SPEC10" FRIEZE, PER SPEC 4" CORNER BOARD, PER SPEC4" TRIM BOARD (TYP.), PER SPECHORIZONTAL SIDING, PER SPECOPT. MASONRY WRAP, PER SPEC 127127 127 STONE VENEER, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPECBRICK SOLDIER COURSE, PER SPEC 4" FRIEZE, PER SPEC 127 \A1;3'-1" \A1;2'-6" 2030 \PFX 2030 \PFX TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING \A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}"\A1;3'-6"\A1;MIN. ROOF SHINGLES, PER SPEC 8" FASCIA, PER SPEC4" FRIEZE, PER SPEC BRICK SOLDIER COURSE, PER SPEC STONE VENEER, PER SPECSTONE SILL, PER SPECBRICK VENEER, PER SPEC OPT. MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC 8" RAKE BOARD, PER SPEC 4" FRIEZE, PER SPEC4" TRIM BOARD (TYP.), PER SPEC127127 SCALE:RIGHT ELEVATION1/8" = 1'-0"- 127 \A1;3'-1" \A1;12'-6{\H0.750000x;\S1#4;}"\PPLATE HT.\A1;7'-2{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#8;}" \A1;8'-1{\H0.750000x;\S1#8;}"\A1;9'-1{\H0.750000x;\S1#8;}" \A1;7'-11{\H0.750000x;\S1#2;}" SCALE:REAR ELEVATION1/8" = 1'-0"- TOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF PLATEWINDOW HEAD HGT. TOP OF FLOORTOP OF FOUNDATION TOP OF FOOTING 1214 1214 1214 1214 OPT. MASONRY WRAP, PER SPEC4" CORNER BOARD, PER SPEC ROOF SHINGLES, PER SPEC8" FASCIA, PER SPEC 1x3 OVER 8" RAKE BOARD, PER SPEC8" FRIEZE, PER SPEC SMOOTH PANEL, PER SPEC6" TRIM BOARD (TYP.), PER SPEC 1214 ELEVATION ET01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3226 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.30 5.38 5.93 52.91 14 0 AT EAVE 6.45 5.38 5.28 47.09 0 76.00 TOTAL (MIN)10.75 10.75 11.21 100.00 3 HIGH - RIDGE VENT 4.30 5.38 6.25 54.22 0 0 50.00 AT EAVE 6.45 5.38 5.28 45.78 0 76.00 TOTAL (MIN)10.75 10.75 11.53 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION ET01 ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 59 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.08 0.10 0.28 80.00 0 1 AT EAVE 0.12 0.10 0.07 20.00 0 1.00 TOTAL (MIN)0.20 0.20 0.35 100.00 3 HIGH - RIDGE VENT 0.08 0.10 0.13 64.29 0 0 1.00 AT EAVE 0.12 0.10 0.07 35.71 0 1.00 TOTAL (MIN)0.20 0.20 0.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE PLOTTED: July 18, 2017 / Mark Muurisepp / 3007-IN-TURIN-ET01.DWG A3-ET01 3FB.3English Tudor2 Car Side Entry w/ StorageElevations and Roof PlanIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032102/05/2016PLAN REVISIONS207/18/2017BUMPOUT REV...................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2017 Joel Hampshire3/30/2015 GARAGE LEFT 3007-Turin TBD -- 06/01/2017 2040 2040 05/20/19 William Hohlt