Loading...
HomeMy WebLinkAboutRiviera_3500 B Sealed Truss Engineering 1700422Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Timberland Home Center-Brazil, IN. Fox, Steve Pages or sheets covered by this seal: I30950485 thru I30950518 My license renewal date for the state of Indiana is July 31, 2018. 1700422 Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/TPI-1, Chapter 2. IMPORTANT NOTE: RIVIERA/3500 B 16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss A Truss Type Common Qty 10 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950485 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:34 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-E97QHC9NV6lPpvwMQF1c5F6ROnbdU5qcULHZwsyi_hp Scale = 1:66.9 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 17 18 3x6 5x6 3x6 3x8 3x6 3x8 3x4 3x4 2x4 3x4 3x4 2x4 3x6 3x8 9-1-13 9-1-13 18-0-0 8-10-3 26-10-3 8-10-3 36-0-0 9-1-13 -0-11-4 0-11-4 6-2-7 6-2-7 12-1-3 5-10-13 18-0-0 5-10-13 23-10-13 5-10-13 29-9-9 5-10-13 36-0-0 6-2-7 36-11-4 0-11-4 0-5-710-11-70-5-77.00 12 Plate Offsets (X,Y)-- [2:0-8-0,0-0-1], [10:0-8-0,0-0-1] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.65 0.85 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.52 0.13 (loc) 10-12 10-12 10 l/defl >999 >824 n/a L/d 240 180 n/a PLATES MT20 Weight: 151 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 6-14,7-14,5-14: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-14, 5-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2=1493/0-3-8, 10=1493/0-3-8 Max Uplift 2=-115(LC 6), 10=-115(LC 6) Max Grav 2=1606(LC 12), 10=1606(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2566/175, 3-5=-2373/192, 5-6=-1703/214, 6-7=-1703/214, 7-9=-2373/192, 9-10=-2566/175 BOT CHORD 2-16=-63/2116, 14-16=0/1698, 12-14=0/1698, 10-12=-63/2116 WEBS 6-14=-111/1267, 7-14=-711/138, 7-12=0/512, 9-12=-352/135, 5-14=-711/138, 5-16=0/512, 3-16=-352/135 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=115, 10=115. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss A1 Truss Type Common Qty 9 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950486 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:35 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-jLhoUXA0GQtGR3VY_yYrdSea_BxPDY?lj?16SIyi_ho Scale = 1:66.4 1 2 3 4 5 6 7 8 9 10 15 14 13 12 11 16 17 3x6 5x6 3x6 3x8 3x6 3x8 3x4 3x4 2x4 3x4 3x4 2x4 3x6 3x8 9-1-13 9-1-13 18-0-0 8-10-3 26-10-3 8-10-3 36-0-0 9-1-13 6-2-7 6-2-7 12-1-3 5-10-13 18-0-0 5-10-13 23-10-13 5-10-13 29-9-9 5-10-13 36-0-0 6-2-7 36-11-4 0-11-4 0-5-710-11-70-5-77.00 12 Plate Offsets (X,Y)-- [1:0-8-0,0-0-1], [9:0-8-0,0-0-1] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.78 0.88 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.56 0.13 (loc) 1-15 1-15 9 l/defl >999 >762 n/a L/d 240 180 n/a PLATES MT20 Weight: 150 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 5-13,6-13,4-13: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-13, 4-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=1431/Mechanical, 9=1498/0-3-8 Max Horz 1=-18(LC 6) Max Uplift 1=-81(LC 6), 9=-116(LC 6) Max Grav 1=1570(LC 12), 9=1610(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2597/182, 2-4=-2399/197, 4-5=-1711/215, 5-6=-1711/215, 6-8=-2381/193, 8-9=-2574/177 BOT CHORD 1-15=-72/2152, 13-15=0/1711, 11-13=0/1705, 9-11=-64/2123 WEBS 5-13=-112/1275, 6-13=-711/137, 6-11=0/512, 8-11=-352/135, 4-13=-722/139, 4-15=0/533, 2-15=-374/143 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 9=116. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss A2 Truss Type Common Qty 5 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950487 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:35 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-jLhoUXA0GQtGR3VY_yYrdSea_BxPDY?lj?16SIyi_ho Scale = 1:65.9 1 2 3 4 5 6 7 8 9 14 13 12 11 10 15 16 3x6 5x6 3x6 3x8 3x6 3x8 3x4 3x4 2x4 3x4 3x4 2x4 3x8 3x6 9-1-13 9-1-13 18-0-0 8-10-3 26-10-3 8-10-3 36-0-0 9-1-13 6-2-7 6-2-7 12-1-3 5-10-13 18-0-0 5-10-13 23-10-13 5-10-13 29-9-9 5-10-13 36-0-0 6-2-7 0-5-710-11-70-5-77.00 12 Plate Offsets (X,Y)-- [1:0-8-0,0-0-1], [9:0-8-0,0-0-1] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.78 0.88 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.20 -0.56 0.13 (loc) 9-10 9-10 9 l/defl >999 >763 n/a L/d 240 180 n/a PLATES MT20 Weight: 149 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 5-12,6-12,4-12: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-12, 4-12 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=1432/0-3-8, 9=1432/Mechanical Max Uplift 1=-81(LC 6), 9=-81(LC 6) Max Grav 1=1571(LC 11), 9=1571(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2578/182, 2-4=-2385/198, 4-5=-1712/216, 5-6=-1712/216, 6-8=-2400/198, 8-9=-2598/183 BOT CHORD 1-14=-89/2122, 12-14=-2/1700, 10-12=-2/1706, 9-10=-91/2147 WEBS 5-12=-113/1275, 6-12=-722/139, 6-10=0/533, 8-10=-374/143, 4-12=-712/138, 4-14=0/516, 2-14=-356/141 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss AG Truss Type Common Supported Gable Qty 2 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950488 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:36 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-BYFBhtBe1k?72D4kYg45AgBuwbTIy21vxfmg_kyi_hn Scale = 1:67.5 Sheet Front Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 54 55 3x6 5x6 3x6 3x6 3x6 3x6 3x6 36-0-0 36-0-0 18-0-0 18-0-0 36-0-0 18-0-0 36-11-4 0-11-4 0-5-710-11-70-5-77.00 12 Plate Offsets (X,Y)-- [20:0-1-10,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.13 0.07 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.01 0.01 (loc) 28 28 27 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 246 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 *Except* 14-41,13-42,12-43,11-44,15-40,16-39,17-38: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 14-41, 13-42, 12-43, 11-44, 15-40, 16-39, 17-38 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 36-0-0. (lb) - Max Horz 1=-18(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 41, 43, 44, 45, 47, 48, 49, 50, 51, 52, 53, 39, 38, 37, 35, 34, 33, 32, 31, 30, 29 Max Grav All reactions 250 lb or less at joint(s) 1, 41, 42, 43, 44, 45, 47, 48, 49, 50, 51, 52, 40, 39, 38, 37, 35, 34, 33, 32, 31, 30, 27 except 53=328(LC 12), 29=317(LC 12) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 17.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 2x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 41, 43, 44, 45, 47, 48, 49, 50, 51, 52, 53, 39, 38, 37, 35, 34, 33, 32, 31, 30, 29. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss B Truss Type Common Qty 4 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950489 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:37 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-fkpZvDBGo18zgMex6NbKjtj?2?eMhMK2AJWDXByi_hm Scale = 1:68.3 1 2 3 4 5 6 7 8 12 11 10 9 3x6 4x6 3x6 3x6 3x8 4x64x6 2x8 3x6 3x6 2x8 10-0-0 10-0-0 20-0-0 10-0-0 5-1-12 5-1-12 10-0-0 4-10-4 14-10-4 4-10-4 20-0-0 5-1-12 20-11-4 0-11-4 1-3-811-3-81-3-812.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.43 0.78 0.69 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.47 0.02 (loc) 9-10 9-10 9 l/defl >999 >505 n/a L/d 240 180 n/a PLATES MT20 Weight: 105 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 4-10: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 12=787/0-3-8, 9=855/0-3-8 Max Horz 12=-47(LC 4) Max Uplift 12=-45(LC 4), 9=-79(LC 4) Max Grav 12=864(LC 8), 9=905(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-356/117, 2-4=-766/171, 4-6=-764/170, 6-7=-397/169, 1-12=-344/101, 7-9=-418/175 BOT CHORD 10-12=0/510, 9-10=0/506 WEBS 4-10=-142/645, 6-10=-271/179, 2-10=-278/180, 2-12=-565/0, 6-9=-539/0 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 9. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss B1G Truss Type Common Structural Gable Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950490 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:38 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-7wMx6ZCuZLGqIWD7f56ZF5G9kO04QrgBPyFm3dyi_hl Scale = 1:67.9 Sheet Front Full Sheathing 1 Ply 7/16" 4x8 OSB 1 2 3 4 5 6 7 89 19 18 17 15 14 13 12 11 1016 4x9 4x6 4x9 3x8 4x64x6 8x8 8x8 5x6 10-0-0 10-0-0 12-0-0 2-0-0 20-0-0 8-0-0 -0-11-4 0-11-4 5-1-12 5-1-12 10-0-0 4-10-4 14-10-4 4-10-4 20-0-0 5-1-12 20-11-4 0-11-4 0-10-210-10-20-10-212.00 12 Plate Offsets (X,Y)-- [2:Edge,0-2-12], [2:0-1-12,0-1-12], [4:0-4-8,0-2-4], [4:0-0-0,0-1-12], [6:0-0-0,0-1-12], [6:0-4-8,0-2-4], [8:0-1-12,0-1-12], [10:Edge,0-2-12], [18:0-3-0,0-3-0], [23:0-2-8,0-0-0], [35:0-2-8,0-0-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.49 0.69 0.55 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.22 -0.57 0.02 (loc) 17-19 17-19 10 l/defl >629 >245 n/a L/d 240 180 n/a PLATES MT20 Weight: 325 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 *Except* 5-17: 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 8-3-8 except (jt=length) 19=0-3-8, 16=0-3-8. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 19, 10, 15 except 16=-205(LC 3) Max Grav All reactions 250 lb or less at joint(s) 15, 14, 13, 12, 11, 16 except 19=881(LC 8), 10=819(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-593/128, 3-5=-745/148, 5-7=-745/148, 7-8=-449/182, 2-19=-556/146, 8-10=-456/184 BOT CHORD 17-19=0/530, 16-17=0/522, 15-16=0/522, 14-15=0/522, 13-14=0/522, 12-13=0/522, 11-12=0/522, 10-11=0/522 WEBS 5-17=-109/614, 7-17=-292/178, 3-17=-303/174, 3-19=-366/0, 7-10=-494/0 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 19, 10, 15 except (jt=lb) 16=205. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss BG Truss Type Common Supported Gable Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950491 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:39 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-b6wJKvDWKfOhvgoJDodooIpPooUY9MQLec?Kb3yi_hk Scale = 1:67.9 Sheet Front Full Sheathing 1 Ply 7/16" 4x8 OSB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 39 3837 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 2x8 3x6 4x6 3x6 2x8 3x6 20-0-0 20-0-0 -0-11-4 0-11-4 10-0-0 10-0-0 20-0-0 10-0-0 20-11-4 0-11-4 1-3-811-3-81-3-812.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.15 0.10 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 20 20 22 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 323 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 11-30,10-31,8-33,12-29,14-28: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 11-30, 10-31, 8-33, 12-29, 14-28 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 20-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 33, 34, 35, 36, 37, 28, 27, 26, 25, 24 except 39=-164(LC 5), 22=-164(LC 5), 30=-200(LC 5), 38=-173(LC 4), 23=-173(LC 4) Max Grav All reactions 250 lb or less at joint(s) 39, 22, 31, 33, 34, 35, 36, 37, 38, 29, 28, 27, 26, 25, 24, 23 except 30=379(LC 4) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-10=-209/284, 10-11=-226/302, 11-12=-226/302, 12-14=-209/284 WEBS 11-30=-363/227 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 33, 34, 35, 36, 37, 28, 27, 26, 25, 24 except (jt=lb) 39=164, 22=164, 30=200, 38=173, 23=173. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss BGR Truss Type Common Girder Qty 1 Ply 3 RIVIERA/3500 B Job Reference (optional) I30950492 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:40 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-3JUhXFE85yWYXqNVnV81KWLSMCfzujCUsGkt7Wyi_hj Scale = 1:71.8 1 2 3 4 5 6 7 11 10 9 8 12 13 14 15 16 17 18 3x6 4x6 3x6 4x9 4x6 10x10 3x8 3x10 3x8 3x10 4x9 HUS26 HUS26 HUS26 HUS26 5-0-3 5-0-3 10-0-0 4-11-13 14-11-13 4-11-13 20-0-0 5-0-3 5-0-3 5-0-3 10-0-0 4-11-13 14-11-13 4-11-13 20-0-0 5-0-3 0-10-210-10-20-10-212.00 12 Plate Offsets (X,Y)-- [1:0-0-3,0-0-3], [1:0-0-5,0-5-3], [7:0-0-3,0-0-3], [7:0-0-5,0-6-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.68 0.79 0.61 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.04 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 370 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP No.1 WEBS 2x4 SPF Stud/No.3 *Except* 4-9: 2x4 SPF No.2 WEDGE Left: 2x8 SP No.2, Right: 2x10 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=7206/0-3-8, 7=7405/0-3-8 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-8413/0, 2-4=-5611/10, 4-6=-5611/0, 6-7=-8533/0 BOT CHORD 1-11=0/5579, 9-11=0/5579, 8-9=0/5661, 7-8=0/5661 WEBS 4-9=0/7490, 6-9=-2615/86, 6-8=0/4003, 2-9=-2495/45, 2-11=0/3826 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 2-0-12 from the left end to 8-0-12 to connect truss(es) to back face of bottom chord. 7) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 1-7=-20 Concentrated Loads (lb) Vert: 10=-1412(B) 9=-1478 12=-1412(B) 13=-1412(B) 14=-1412(B) 15=-1478 16=-1478 17=-1478 18=-1478 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss C Truss Type Common Qty 7 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950493 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:40 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-3JUhXFE85yWYXqNVnV81KWLZ3ChZupSUsGkt7Wyi_hj Scale = 1:39.6 1 2 3 4 5 6 7 8 4x6 3x8 5x9 2x42x4 3x8 9-0-0 9-0-0 18-0-0 9-0-0 -0-11-4 0-11-4 4-7-0 4-7-0 9-0-0 4-5-0 13-5-0 4-5-0 18-0-0 4-7-0 18-11-4 0-11-4 0-6-66-6-60-6-68.00 12 Plate Offsets (X,Y)-- [2:0-0-11,0-1-0], [2:0-1-5,0-5-8], [2:0-3-8,Edge], [6:0-3-8,Edge], [6:0-1-5,0-5-8], [6:0-0-11,0-1-0], [8:0-4-8,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.25 0.69 0.21 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.34 0.03 (loc) 6-8 6-8 6 l/defl >999 >627 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 WEDGE Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2=773/0-3-8, 6=773/0-3-8 Max Uplift 2=-74(LC 4), 6=-74(LC 4) Max Grav 2=816(LC 8), 6=816(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1036/99, 3-4=-818/89, 4-5=-818/89, 5-6=-1036/99 BOT CHORD 2-8=-3/788, 6-8=-3/788 WEBS 4-8=-14/558, 5-8=-302/118, 3-8=-302/118 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss CG Truss Type Common Supported Gable Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950494 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:41 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-XV24lbEmsGeP9_yiLDfGtjumOcB3dIue5wURgyyi_hi Scale = 1:40.8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 27 26 25 24 23 22 21 20 19 18 17 16 4x6 3x4 3x8 3x6 3x4 3x8 18-0-0 18-0-0 -0-11-4 0-11-4 9-0-0 9-0-0 18-0-0 9-0-0 18-11-4 0-11-4 0-6-66-6-60-6-68.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-13], [2:0-2-3,Edge], [14:0-0-0,0-0-13], [14:0-2-3,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.08 0.03 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 15 15 14 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 94 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 WEDGE Left: 2x4 SPF Stud/No.3, Right: 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 18-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 2, 21, 22, 23, 24, 26, 27, 20, 19, 18, 17, 16, 14 Max Grav All reactions 250 lb or less at joint(s) 2, 21, 22, 23, 24, 26, 27, 20, 19, 18, 17, 16, 14 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 21, 22, 23, 24, 26, 27, 20, 19, 18, 17, 16, 14. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss CGR Truss Type Common Girder Qty 1 Ply 3 RIVIERA/3500 B Job Reference (optional) I30950495 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:41 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-XV24lbEmsGeP9_yiLDfGtjugScy7d4ie5wURgyyi_hi Scale = 1:41.0 1 2 3 4 5 9 8 7 610 11 12 13 14 15 16 3x8 4x6 3x85x6 10x10 3x8 3x10 3x8 3x10 HUS26 HUS26 HUS26 HUS26 4-8-8 4-8-8 9-0-0 4-3-8 13-3-8 4-3-8 18-0-0 4-8-8 4-8-8 4-8-8 9-0-0 4-3-8 13-3-8 4-3-8 18-0-0 4-8-8 0-6-66-6-60-6-68.00 12 Plate Offsets (X,Y)-- [1:0-8-0,0-0-11], [5:0-8-0,0-0-11] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.46 0.99 0.98 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.06 (loc) 7-9 7-9 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 246 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=6389/0-3-8, 5=6318/0-3-8 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-9285/0, 2-3=-6315/0, 3-4=-6315/0, 4-5=-9276/0 BOT CHORD 1-9=0/7512, 7-9=0/7512, 6-7=0/7504, 5-6=0/7504 WEBS 3-7=0/6660, 4-7=-2898/0, 4-6=0/3375, 2-7=-2908/0, 2-9=0/3385 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Use Simpson Strong-Tie HUS26 (14-10d Girder, 4-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 9-11-4 from the left end to 15-11-4 to connect truss(es) to back face of bottom chord. 7) Fill all nail holes where hanger is in contact with lumber. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 1-5=-20 Concentrated Loads (lb) Vert: 8=-1412 10=-1412 11=-1412 12=-1412 13=-1411(B) 14=-1411(B) 15=-1411(B) 16=-1411(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss DG Truss Type Common Supported Gable Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950496 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:42 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-0hcSyxFPdamGm8XuuwAVQxRxZ0X_MkenKaD_COyi_hh Scale = 1:42.8 Sheet Front Full Sheathing 1 Ply 7/16" 4x8 OSB 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x8 4x6 3x8 12-0-0 12-0-0 -0-11-4 0-11-4 6-0-0 6-0-0 12-0-0 6-0-0 12-11-4 0-11-4 0-10-26-10-20-10-212.00 12 Plate Offsets (X,Y)-- [10:0-4-12,0-1-8], [20:0-4-12,0-1-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-R 0.12 0.05 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.00 0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 129 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 12-0-0. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 except 16=-106(LC 5) Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 except (jt=lb) 16=106. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss E Truss Type MONO Qty 4 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950497 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:42 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-0hcSyxFPdamGm8XuuwAVQxRwW0PQMlUnKaD_COyi_hh Scale = 1:19.2 1 2 3 4 5 6 7 2x4 3x4 3x4 3x4 2x4 6-10-8 6-10-8 7-0-0 0-1-8 -0-11-4 0-11-4 3-4-14 3-4-14 6-10-8 3-5-10 7-0-0 0-1-8 0-7-152-11-15 4.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-0-7] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.19 0.54 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.33 0.00 (loc) 2-6 2-6 6 l/defl >621 >249 n/a L/d 240 180 n/a PLATES MT20 Weight: 26 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 SLIDER Left 2x4 SPF Stud/No.3 1-8-6 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2=334/0-3-8, 6=270/0-3-8 Max Horz 2=32(LC 7) Max Uplift 2=-100(LC 6), 6=-69(LC 6) Max Grav 2=342(LC 9), 6=300(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-368/155 BOT CHORD 2-6=-135/300 WEBS 4-6=-322/187 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss E1 Truss Type MONO Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950498 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:43 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-UuAq9HG1Otu7OH64Seiky8z_?PoH5DWxYEzXkqyi_hg Scale = 1:17.2 1 2 3 4 5 6 2x4 3x4 3x4 3x4 2x4 5-10-8 5-10-8 6-0-0 0-1-8 -0-11-4 0-11-4 5-10-8 5-10-8 6-0-0 0-1-8 0-7-152-7-154.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-0-7] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.59 0.37 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.18 0.00 (loc) 2-5 2-5 5 l/defl >997 >399 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 SLIDER Left 2x4 SPF Stud/No.3 3-0-5 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2=295/0-3-8, 5=230/0-3-8 Max Horz 2=30(LC 6) Max Uplift 2=-95(LC 6), 5=-63(LC 6) Max Grav 2=301(LC 9), 5=251(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss EG Truss Type Monopitch Structural Gable Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950499 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:43 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-UuAq9HG1Otu7OH64Seiky8z_?Prg5DWxYEzXkqyi_hg Scale = 1:17.9 Sheet Back Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 6 5 8 2x4 2x43x4 3x4 3x4 2x4 2x4 6-0-0 6-0-0 -0-11-4 0-11-4 6-0-0 6-0-0 0-7-152-7-154.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-0-7] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.59 0.15 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.04 0.00 (loc) 2-6 2-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 23 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 SLIDER Left 2x4 SPF Stud/No.3 3-0-5 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 6-0-0. (lb) - Max Horz 2=30(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 5=-114(LC 6), 2=-108(LC 6) Max Grav All reactions 250 lb or less at joint(s) 5, 5, 6 except 2=279(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 114 lb uplift at joint 5 and 108 lb uplift at joint 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss EGR Truss Type MONO TRUSS Qty 1 Ply 2 RIVIERA/3500 B Job Reference (optional) I30950500 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:44 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-y4kCNcHf9B0_0RhH0LDzVMWD7p5EqbS4nui5GHyi_hf Scale = 1:19.2 1 2 3 4 6 5 7 8 9 3x4 2x4 2x4 3x6 4x6 3-7-14 3-7-14 7-0-0 3-4-2 -0-11-4 0-11-4 3-7-14 3-7-14 7-0-0 3-4-2 0-7-152-11-15 4.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.37 0.51 0.34 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.04 0.01 (loc) 2-6 2-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 59 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 2=1296/0-3-8, 5=1608/0-3-8 Max Horz 2=35(LC 6) Max Uplift 2=-71(LC 6), 5=-17(LC 6) Max Grav 2=1305(LC 9), 5=1639(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2184/10 BOT CHORD 2-6=-5/1970, 5-6=-5/1970 WEBS 3-6=0/1541, 3-5=-2176/48 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 4) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 5) Unbalanced snow loads have been considered for this design. 6) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 2 and 17 lb uplift at joint 5. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 2-5=-20, 1-4=-60 Concentrated Loads (lb) Vert: 7=-767 8=-767 9=-769 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss F Truss Type MONO Qty 4 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950501 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:44 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-y4kCNcHf9B0_0RhH0LDzVMWAOp8qqgm4nui5GHyi_hf Scale = 1:15.5 1 2 3 4 5 2x4 2x4 2x4 5-10-8 5-10-8 6-0-0 0-1-8 -0-11-4 0-11-4 5-10-8 5-10-8 6-0-0 0-1-8 0-3-152-3-154.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.55 0.35 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.16 0.00 (loc) 2-4 2-4 4 l/defl >999 >430 n/a L/d 240 180 n/a PLATES MT20 Weight: 17 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2=300/0-3-8, 4=222/0-3-8 Max Horz 2=43(LC 6) Max Uplift 2=-103(LC 6), 4=-59(LC 6) Max Grav 2=305(LC 9), 4=243(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint 2 and 59 lb uplift at joint 4. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss F1 Truss Type MONO Qty 5 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950502 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:45 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-QGHaayIHwV8rebGTa3kC1Z3RmDXMZ70D0YSepjyi_he Scale = 1:11.1 1 2 3 4 5 2x4 2x4 2x4 3-10-8 3-10-8 4-0-0 0-1-8 -0-11-4 0-11-4 3-10-8 3-10-8 4-0-0 0-1-8 0-3-151-7-154.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.19 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2=223/0-3-8, 4=139/0-3-8 Max Horz 2=34(LC 6) Max Uplift 2=-88(LC 6), 4=-36(LC 6) Max Grav 2=225(LC 9), 4=146(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 88 lb uplift at joint 2 and 36 lb uplift at joint 4. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss FG Truss Type Monopitch Supported Gable Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950503 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:45 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-QGHaayIHwV8rebGTa3kC1Z3KWDUlZ70D0YSepjyi_he Scale = 1:14.9 Sheet Back Full Sheathing 1 Ply 1/2 x 4 x 8 Duramate 1 2 3 4 5 2x4 2x42x4 -0-11-4 0-11-4 6-0-0 6-0-0 0-3-152-3-154.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.59 0.37 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.02 0.07 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 120 120 n/a PLATES MT20 Weight: 17 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4=230/6-0-0, 2=295/6-0-0 Max Horz 2=43(LC 6) Max Uplift 4=-61(LC 6), 2=-98(LC 6) Max Grav 4=251(LC 9), 2=301(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 61 lb uplift at joint 4 and 98 lb uplift at joint 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V1 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950504 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:46 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-uTrzoIIvgoGiFlqf7mFRanbYCdpIIWmNFCBBL9yi_hd Scale = 1:60.1 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 19-5-10 19-5-10 9-8-13 9-8-13 19-5-10 9-8-13 9-8-1312.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.40 0.35 0.29 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 75 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 *Except* 3-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 19-5-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 8 except 9=-194(LC 4), 6=-194(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=616(LC 7), 6=616(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-479/247, 4-6=-481/248 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8 except (jt=lb) 9=194, 6=194. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V2 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950505 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:48 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-qrzjD_K9CQWQV3_2FBHvfChxyQXomSIgiWgIP2yi_hb Scale = 1:55.2 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 17-1-10 17-1-10 8-6-13 8-6-13 17-1-10 8-6-13 8-6-1312.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.26 0.22 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 64 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 17-1-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-165(LC 4), 6=-165(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=516(LC 7), 6=516(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-407/211, 4-6=-408/212 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 165 lb uplift at joint 9 and 165 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V3 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950506 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:49 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-I2X5QKLozjeG6CZEpup8CPD7jquoVvqpxAQsyUyi_ha Scale = 1:48.6 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 14-9-10 14-9-10 7-4-13 7-4-13 14-9-10 7-4-13 7-4-1312.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.19 0.17 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 54 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 14-9-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) except 9=-145(LC 4), 6=-145(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 9=436(LC 7), 6=436(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-352/187, 4-6=-352/187 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 145 lb uplift at joint 9 and 145 lb uplift at joint 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V4 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950507 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:49 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-I2X5QKLozjeG6CZEpup8CPD70qvpVwTpxAQsyUyi_ha Scale = 1:39.2 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 12-5-10 12-5-10 6-2-13 6-2-13 12-5-10 6-2-13 6-2-1312.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.17 0.10 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 44 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 12-5-10. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-136(LC 4), 6=-136(LC 4) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=386(LC 7), 6=386(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-322/177, 4-6=-322/177 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=136, 6=136. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V5 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950508 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:50 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-nE5TdgLQk1m7kM8QMcKNkdmC8EEgENly9q9PUwyi_hZ Scale: 3/8"=1' 1 2 3 42x8 4x6 2x8 2x4 10-1-10 10-1-10 5-0-13 5-0-13 10-1-10 5-0-13 5-0-1312.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.53 0.19 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=210/10-1-10, 3=210/10-1-10, 4=334/10-1-10 Max Uplift 1=-34(LC 4), 3=-34(LC 4) Max Grav 1=236(LC 7), 3=236(LC 7), 4=364(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V6 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950509 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:50 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-nE5TdgLQk1m7kM8QMcKNkdmI1EE_ENzy9q9PUwyi_hZ Scale: 3/8"=1' 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 14-8-13 14-8-13 7-4-6 7-4-6 14-8-13 7-4-6 4-10-158.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.15 0.17 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 14-8-13. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=259(LC 1), 9=386(LC 7), 6=386(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-307/120, 4-6=-307/120 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V7 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950510 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:51 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-FQfsr0M2VLu_MWjdwJrcHqJOzeawzrp6OUvy0Nyi_hY Scale = 1:26.1 1 2 3 4 2x4 4x6 2x42x4 7-9-10 7-9-10 3-10-13 3-10-13 7-9-10 3-10-13 3-10-1312.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.46 0.19 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=170/7-9-10, 3=170/7-9-10, 4=229/7-9-10 Max Uplift 1=-41(LC 4), 3=-41(LC 4) Max Grav 1=197(LC 7), 3=197(LC 7), 4=238(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V8 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950511 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:51 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-FQfsr0M2VLu_MWjdwJrcHqJNWeZOzqB6OUvy0Nyi_hY Scale: 1/2"=1' 1 2 3 43x4 4x6 3x42x4 11-2-13 11-2-13 5-7-6 5-7-6 11-2-13 5-7-7 3-8-158.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.55 0.22 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 31 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=201/11-2-13, 3=201/11-2-13, 4=419/11-2-13 Max Uplift 1=-30(LC 4), 3=-30(LC 4), 4=-5(LC 4) Max Grav 1=227(LC 7), 3=227(LC 7), 4=455(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-292/62 NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V9 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950512 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:51 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-FQfsr0M2VLu_MWjdwJrcHqJS6ebYzr86OUvy0Nyi_hY Scale = 1:19.3 1 2 3 4 2x4 4x6 2x42x4 5-5-10 5-5-10 2-8-13 2-8-13 5-5-10 2-8-13 2-8-1312.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.20 0.09 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-5-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=114/5-5-10, 3=114/5-5-10, 4=153/5-5-10 Max Uplift 1=-30(LC 4), 3=-30(LC 4) Max Grav 1=133(LC 7), 3=133(LC 7), 4=160(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V10 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950513 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:46 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-uTrzoIIvgoGiFlqf7mFRanbZtds1IadNFCBBL9yi_hd Scale = 1:17.6 1 2 3 4 2x4 4x6 2x42x4 7-8-13 7-8-13 3-10-6 3-10-6 7-8-13 3-10-7 2-6-158.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.36 0.17 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=145/7-8-13, 3=145/7-8-13, 4=252/7-8-13 Max Uplift 1=-32(LC 4), 3=-32(LC 4) Max Grav 1=167(LC 7), 3=167(LC 7), 4=268(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V11 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950514 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:47 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-MfPL?eJXR6OZtvPshUmg7_8jc1D_11kWTsxltcyi_hc Scale = 1:16.4 1 2 3 4 5 6 2x4 4x6 2x42x4 8-11-8 8-11-8 4-5-12 4-5-12 8-11-8 4-5-12 2-2-146.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.42 0.13 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 22 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=156/8-11-8, 3=156/8-11-8, 4=305/8-11-8 Max Uplift 1=-49(LC 6), 3=-49(LC 6), 4=-27(LC 6) Max Grav 1=160(LC 11), 3=160(LC 11), 4=305(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V12 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950515 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:47 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-MfPL?eJXR6OZtvPshUmg7_8nZ17H11VWTsxltcyi_hc Scale: 1"=1' 1 2 3 2x4 3x6 2x4 6-3-8 6-3-8 3-1-12 3-1-12 6-3-8 3-1-12 1-6-146.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.17 0.49 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=202/6-3-8, 3=202/6-3-8 Max Uplift 1=-51(LC 6), 3=-51(LC 6) Max Grav 1=207(LC 11), 3=207(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V13 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950516 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:48 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-qrzjD_K9CQWQV3_2FBHvfCh_EQZcmUlgiWgIP2yi_hb Scale = 1:10.6 1 2 3 2x4 3x6 2x4 3-1-10 3-1-10 1-6-13 1-6-13 3-1-10 1-6-13 1-6-1312.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.05 0.10 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=97/3-1-10, 3=97/3-1-10 Max Uplift 1=-11(LC 4), 3=-11(LC 4) Max Grav 1=109(LC 7), 3=109(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss V14 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950517 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:48 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-qrzjD_K9CQWQV3_2FBHvfChznQXAmUlgiWgIP2yi_hb Scale = 1:9.8 1 2 3 2x4 3x6 2x4 4-2-13 4-2-13 2-1-6 2-1-6 4-2-13 2-1-7 1-4-158.00 12 Plate Offsets (X,Y)-- [2:0-3-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-P 0.07 0.19 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 9 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1=131/4-2-13, 3=131/4-2-13 Max Uplift 1=-15(LC 4), 3=-15(LC 4) Max Grav 1=147(LC 7), 3=147(LC 7) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks Job 1700422 Truss VG1 Truss Type Valley Qty 1 Ply 1 RIVIERA/3500 B Job Reference (optional) I30950518 8.030 s Aug 11 2017 MiTek Industries, Inc. Fri Sep 01 13:14:52 2017 Page 1 Timberland Lumber Company, Indianapolis, IN 46222 ID:jSwRVIeZs?LZ4y394kB4Puy9k5v-jdDE2MNgGe1rzgIpU1Mrq2rbc2wbiIrFd8eWYpyi_hX Scale = 1:20.0 Sheet Back Full Sheathing 1 Ply 7/16" 4x8 OSB 1 2 3 4 5 8 7 6 3x4 4x6 3x42x4 2x4 2x4 2x4 2x4 11-7-8 11-7-8 5-9-12 5-9-12 11-7-8 5-9-12 2-10-146.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IBC2012/TPI2007 CSI. TC BC WB Matrix-S 0.28 0.10 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 55 lb FT = 0% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF Stud/No.3 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud/No.3 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 11-7-8. (lb) - Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 except 7=-118(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=355(LC 11), 6=355(LC 11) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6 except (jt=lb) 7=118. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. September 5,2017 05/01/19 Mike Sheeks PRODUCT CODE APPROVALS LATERAL BRACING LOCATIONMin size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the platewidth measured perpendicularto slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths. Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause Property Damage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside" 16/1-0 ICC-ES Reports: ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS. W4 - 6 W3-6W3 -7W2-7W1-7C1-8 C5-6C6-7C7-8 C4-5 C3-4C2-3C1-2 TOP CHORD TOP CHORD 8 7 6 54321 BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates therequired direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbols Numbering System General Safety Notes* Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8 dimensions shown in ft-in-sixteenths WEBS Trusses are designed for wind loads in the plane of thetruss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1section 6.3 These truss designs rely on lumber valuesestablished by others.05/01/19 Mike Sheeks