Loading...
HomeMy WebLinkAboutLEGACY RIDGE 84 - LR84 (AS DESIGNED)IECC 2009 Performance Compliance Property 14309 NEW GARDEN LN CARMEL, IN 46033 Model: RIVIERA Community: LEGACY RIDGE 84 LR84 (AS DESIGNED) LEGACY RIDGE 84 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance 51,793 $288 $398 $2,479 $943 $0 $3,422 Requirements C-M, Energy Solutions As Designed $1,750 $269 $398 $2,416 $943 $0 $3,359 Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name Organization Matthew Timmons TSI Energy Solutions Signature: Date: 413119 at 2:40 PM Ekotrope RATER - Version 3.1.0.2144 ECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 405.3 Performance-based compliance passes by 2.5% 402.4.1.2 Air Leakage Testing Air sealing is 6.0[) ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 2.5%. Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name Organization Matthew Timmons TSI Energy Solutions Signature: Date: 413119 at 2:40 PM Ekotrope RATER - Version 3.1.0.2144 ECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 14309 NEW GARDEN LN CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U -Value: 0.31, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 324.0 CFM @ 25Pa Total Duct Leakage 432.0 CFM c@ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 4/3119 at 2:40 PM Ekotrope RATER - Version 3.1.0.2144 2009 1 ECC compliance resu Its calculated usi ng Ekotrope RATERS energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Cade Inspection Checklist Property Organization 14309 NEW GARDEN LN TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: RIVIERA Community: LEGACY RIDGE 84 Builder LENNAR HOMES LR84 (AS DESIGNED) LEGACY RIDGE 84 General Building Information Conditioned Area (sq ft) 5,446 Conditioned Volume (cubic ft) 48,408 Insulated Shell Area (sq ft) 9,507 Inspection Status Results are projected C-M, Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT (1,712 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (428 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I El Name: OVER AMBIENT (14 s.f,) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall 1� Name: CON DIAMB (Exterior Perimeter [ft]: 131; Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) 1--1 R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 1—t Name: CON DIGAR (Exterior Perimeter [ft]: 43; Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) L–1 R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall 1 Energy Cade Inspection Checklist Property Organization 14309 NEW GARDEN LN TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: RIVIERA Community: LEGACY RIDGE 84 Builder LENNAR HOMES LR84 (AS DESIGNED) LEGACY RIDGE 84 Name: CONDIAMB (2,387 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CON DIAM B 2X6 (270 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (387 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I 1� Name: CON DIATTIC (218 s.f.) 1--1 R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CON DIAM B (270 s.f.) R: 13.575 E] Name: CON DIGAR (43 s.f.) R: 10.876 Roof Name: CON DIATTIC (58 s.f.) R: 10.876 Name: SECOND (2,154 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door 1� Name: FRONT (20 s.f.) 1--1 u: 0.182 Inspection Status Results are projected C-M, Energy Solutions 2 Energy Cade Inspection Checklist Property 14309 NEW GARDEN LN CARMEL, IN 46033 Model: RIVIERA Community: LEGACY RIDGE 84 LR84 (AS DESIGNED) LEGACY RIDGE 84 Name: GARAGE (18 s.f.) U: 0.182 Glazing Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected El Name: FRONT (127 s.f.), U:0.310, SHGC: 0.29, Orientation: EAST 1� Name: BACK (174 s.f.), U:0.310, SHGC: 0.31, Orientation: WEST El Name: BACK 2X6 (77 s.f.), U:0.310, SHGC: 0.31, Orientation: WEST El Name: BACK 2X6 GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST Name: RIGHT SIDE (83 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH 0 Name: RIGHT SIDE BSMT (16 s.f.), U:0.490, SHGC: 0.66, Orientation: NORTH Name: LEFT SIDE (59 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH Name: LEFT BSMT (16 s.f.), U:0.490, SHGC: 0.66, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE [] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER El Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor C-M, Energy Solutions 3 Energy Cade Inspection Checklist Property 14309 NEW GARDEN LN CARMEL, IN 46033 Model: RIVIERA Community: LEGACY RIDGE 84 LR84 (AS DESIGNED) LEGACY RIDGE 84 Air Leakage Control Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected Test Status: Blower -door tested House is air -sealed as to achieve 4,841 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 324.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 432.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors — 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 1 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage {= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C-M, Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 14309 NEW GARDEN LN TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: RIVIERA 5,446 Community: LEGACY RIDGE 5= Builder Conditioned Volume [cu. ft.] LENNAR HOMES LR34 (AS DESIGNED) 1 LEGACY RIDGE 84 Single family detached General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 5,446 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 48,408 Total Units in Building 1 Residence Type Single family detached Model RIVIERA Community LEGACY RIDGE 84 Climate Zone 5A Basement Wall��his A Name Library type Height Above Grade Depth Below Grade C-M, Energy Solutions CONDIAMB R-11 Draped, 4ft 1 8 131 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4ft 1 8 43 Exposed Exterior Conditioned Space Basement Wall Library List Name Feet From Wall Top To Insu R-11 Draped, 4ft 0 4 No 11.00 Slab Name Library type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSI.1T Uninsulated 174 Below Grade 0 a 1,712.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction type Slab Completel�l Insulated. Unders lab Insulation Width [fq Perimeter Insulation Depth [ftJ Perimeter Insulation R Effective R -value Value Uninsulated Wood Frame /Other No 0 0 6 0.00 1 Building Summary Property Organization 14309 NEW GARDEN LN TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: RIVIERA Exposed Exterior Community: LEGACY RIDGE 84 Builder LENNAR HOMES LR34 (AS DESIGNED) LEGACY RIDGE 84 Framed Floor Name Library type Car OVER AMBIENT R-38, GR1 OVER GARAGE R-38, GR1 Framed Floor Library List Name �A Effective R -value R-38, GR1 33.825 Rim Joist Name Library Type CONDIAMB G1 R-13. R-3.0 COiND1ATTIC G1 R-13, OSB CONDIGAR G1 R-13, OSB Rim Joist Library List Name Effective Insulation R -value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 C-M Energy Solutions Inspection Status Results are projected ret R Floor Grade SUrraceArea Location 1.23 Above Grade 14.0 sq. ft. Exposed Exterior 1.23 Above Grade 428.0 sq. ft. Unconditioned, attached garage Surface Area Location 270.6 sq. R. Exposed Exterior 58.0 sq. it Unconditioned, attached garage 43.0 sq. It Unconditioned, attached garage E M Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-13 BATT, R-3.0 Medium 2,387.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 270.0 sq. R. Exposed Exterior 2 Building Summary Property Organization Inspection Status C-MEnergy Solutions 14309 NEW GARDEN LN TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: RIVIERA Community: LEGACY RIDGE 84 Builder LENNAR HOMES LR34 (AS DESIGNED) LEGACY RIDGE 84 Name Library Type Surface Calor Surface Area Location CONDIATTIC G1 R-13 BATT, R-3.0 Medium 218.0 sq. ft. Attic CONDIGAR G1 R-13 Gar Walls Medium 387.0 sq. ft. Unconditioned, attached garage ■ Wall Library List Name Effective R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R3.02X6 20.217 Glazing Name Library lype Wall Assignment Basement Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK U-.31, SHGC-.31 CONDIAMB ❑ 0 0 West 174.0 sq. ft. BACK 2X6 U-.31, SHGC-.31 CONDIAMB 2X6 ❑ 0 0 West 77.0 sq. 11 BACK 2X6 GD U-29, SHGC-.33 CONDIAMB 2X6 ❑ 0 0 West 18.0 sq. ft. FRONT U-.31, SHGC-29 CONDIAMB ❑ 0 0 East 127.0 sq. ft. LEFT BSMT U-d9, SHGC-.66 CONDIAMB 0 0 0 South 16.0 sq. ft. LEFT SIDE 111-.32, SHGC-.31 CONDIAMB 0 0 0 South 59.0 sq. ft. RIGHT SIDE 111-.32, SHGC-.31 CONDIAMB ❑ 0 0 North 83.0 sq. ft. RIGHT SIDE BSMT U-.49, SHGC-.66 CONDIAMB ❑ 0 0 North 16.0 sq. ft. 3 Building Summary Property Organization Inspection Status 14309 NEW GARDEN LN TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Assignment Model: RIVIERA Community: LEGACY RIDGE 84 Builder 20.0 sq. ft. Exposed Exterior LENNAR HOMES LR34 (AS DESIGNED) 0.9 0.75 Medium LEGACY RIDGE 84 Exposed Exterior Glazing (Library List Name Shgc U -factor U-.29, SHGG.33 0.33 8.296 U-.31, SHGC-.29 0.29 0.310 U-.31, SHGG.31 0.31 0.310 U-.32, SHGG.31 0.31 0.320 U-.49. SHGC-.66 0.66 0.490 Skylight one Skylight Library List i None C-M, Energy Solutions Opaque Door Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab so rp tan ce FRONT Steel Door CONDlAMB 0.9 0.75 Medium 20.0 sq. ft. Exposed Exterior GARAGE Steel Door CONDlGAR 0.9 0.75 Medium 18.0 sq. ft. Exposed Exterior Opaque Door Library List Name Effective U -factor Steel Door 0.182 4 Building Summary Property 14309 NEW GARDEN LN CARMEL, IN 46033 Model: RIVIERA Community: LEGACY RIDGE 84 LR34 (AS DESIGNED) LEGACY RIDGE 84 Roof Insulation Name Library type EC'0`,JD R-38 Blown, GR1 Organization TSI Energy Solutions Ma tthew Ti m mon s Builder LENNAR HOMES r Area clay or P.f.] 2,154 Inspection Status Results are projected Tiles No Roof Insulation Library List Name Has Radiant Barrier Effective R -value R-38 Blown, GR1 No 38268 Whole House Infiltration Infiltration Measurement Typi 6 ACH at 50 Pa Blower -door tested Mechanical Ventilation None Present 4 C-M, Energy Solutions Medium 2,154.0 sq. ft. Attic LightingE101"a °I Interior Fluorescent °I Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting °I Garage Fluorescent °I Garage LED Lighting Lighting Lighting Lighting a to,-- 0 100 0 100 Onsite Generation None Present ,:I Building Summary Property C-MEnergy Solutions Organization Inspection Status 14309 NEW GARDEN LN TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: RIVIERA Community: LEGACY RIDGE 5= Builder LENNAR HOMES LR34 (AS DESIGNED) LEGACY RIDGE 84 Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Air conditioner (2) Fuel -fired air distribution (1) Water Heating (3) CA13NA042 9155A48080S17 RE350" Equipment Type: 915SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 78 Use default EAE N0 EAE [kWh] 946 Equipment Type: CA13NA042 M Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 46 g Percent LOaS 0% 100% 0% 100% 0% a% 100°% 11 Building Summary Property 14309 NEW GARDEN LN CARMEL, IN 46033 Model: RIVIERA Community: LEGACY RIDGE LR34 (AS DESIGNED) LEGACY RIDGE 84 Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Distribution System Distribution Type Heating Equipment Cooling Equipment Sq. Feet Served # Return Grilles Supply Duct R Value Return Duct R Value Supply Duct Area [sq. ft.] Return Duct Area [sq. ft] Duct Leakage to Outdoors (CFM25) Total Leakage Total Leakage Duct Test Conditions Use Default Flow Rate Duct 1 Duct Location Percent Supply Area Percent Return Area Duct 2 Duct Location Percent Supply Area Percent Return Area Duct 3 Duct Location Percent Supply Area Percent Return Area Duct 4 Duct Location Percent Supply Area Percent Return Area Duct 5 Duct Location Percent Supply Area Percent Return Area Duct 6 Duct Location Percent Supply Area Percent Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt Organization TSI Energy Solutions Ma tthew Ti m mon s Builder LENNAR HOMES Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 ❑.98 Forced Air Fuel -fired air distribution (1) Air conditioner (2) 5446 4 30 20 1470.42 1089.2 324 432 Post -Construction Yes Conditioned Space 60 60 Attic (well vented, under insulation) 40 40 Conditioned Space Conditioned Space 0 Conditioned Space Conditioned Space 0 No 100 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 14309 NEW GARDEN LN CARMEL, IN 46033 Model: RIVIERA Community: LEGACY RIDGE 84 LR34 (AS DESIGNED) LEGACY RIDGE 84 Organization Inspection Status TSI Energy Solutions Results are projected Ma tthew Ti m mon s Builder LENNAR HOMES Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 166 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.617 Field Utilization Timer Controls Asher Label Energy Rating 764 kWh/Year Electric Rate $0.081kWh Annual Gas Cost $23.00 Gas Rate $0.58frherm Capacity 2.874 Imef 0.331 Appliances and Controls M Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Electric Convection Oven? No Induction Range? No Refrigerator Consumption 769 kWh/Year C-M, Energy Solutions