HomeMy WebLinkAboutLEGACY RIDGE 84 - LR84 (AS DESIGNED)IECC 2009 Performance Compliance
Property
14309 NEW GARDEN LN
CARMEL, IN 46033
Model: RIVIERA
Community: LEGACY RIDGE 84
LR84 (AS DESIGNED)
LEGACY RIDGE 84
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
51,793
$288
$398
$2,479
$943
$0
$3,422
Requirements
C-M,
Energy Solutions
As Designed
$1,750
$269
$398
$2,416
$943
$0
$3,359
Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name
Organization
Matthew Timmons
TSI Energy Solutions
Signature:
Date:
413119 at 2:40 PM
Ekotrope RATER - Version 3.1.0.2144
ECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
405.3
Performance-based compliance passes by 2.5%
402.4.1.2
Air Leakage Testing Air sealing is 6.0[) ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa.
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U -Factor
403.2.2
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R405.2
Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 2.5%.
Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name
Organization
Matthew Timmons
TSI Energy Solutions
Signature:
Date:
413119 at 2:40 PM
Ekotrope RATER - Version 3.1.0.2144
ECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
14309 NEW GARDEN LN
CARMEL, IN 46033
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 6 ACH50
Window U -Value: 0.31, SHGC: 0.31
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 324.0 CFM @ 25Pa
Total Duct Leakage 432.0 CFM c@ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 4/3119 at 2:40 PM
Ekotrope RATER - Version 3.1.0.2144
2009 1 ECC compliance resu Its calculated usi ng Ekotrope RATERS energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Cade Inspection Checklist
Property Organization
14309 NEW GARDEN LN TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Model: RIVIERA
Community: LEGACY RIDGE 84 Builder
LENNAR HOMES
LR84 (AS DESIGNED)
LEGACY RIDGE 84
General Building Information
Conditioned Area (sq ft) 5,446
Conditioned Volume (cubic ft) 48,408
Insulated Shell Area (sq ft) 9,507
Inspection Status
Results are projected
C-M,
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT (1,712 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (428 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
El Name: OVER AMBIENT (14 s.f,)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
1� Name: CON DIAMB (Exterior Perimeter [ft]: 131; Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
1--1 R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
1—t Name: CON DIGAR (Exterior Perimeter [ft]: 43; Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
L–1 R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
1
Energy Cade Inspection Checklist
Property
Organization
14309 NEW GARDEN LN
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Model: RIVIERA
Community: LEGACY RIDGE 84
Builder
LENNAR HOMES
LR84 (AS DESIGNED)
LEGACY RIDGE 84
Name: CONDIAMB (2,387 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CON DIAM B 2X6 (270 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (387 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
1� Name: CON DIATTIC (218 s.f.)
1--1 R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Name: CON DIAM B (270 s.f.)
R: 13.575
E] Name: CON DIGAR (43 s.f.)
R: 10.876
Roof
Name: CON DIATTIC (58 s.f.)
R: 10.876
Name: SECOND (2,154 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
1� Name: FRONT (20 s.f.)
1--1 u: 0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
2
Energy Cade Inspection Checklist
Property
14309 NEW GARDEN LN
CARMEL, IN 46033
Model: RIVIERA
Community: LEGACY RIDGE 84
LR84 (AS DESIGNED)
LEGACY RIDGE 84
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
El Name: FRONT (127 s.f.), U:0.310, SHGC: 0.29, Orientation: EAST
1� Name: BACK (174 s.f.), U:0.310, SHGC: 0.31, Orientation: WEST
El Name: BACK 2X6 (77 s.f.), U:0.310, SHGC: 0.31, Orientation: WEST
El Name: BACK 2X6 GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST
Name: RIGHT SIDE (83 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH
0 Name: RIGHT SIDE BSMT (16 s.f.), U:0.490, SHGC: 0.66, Orientation: NORTH
Name: LEFT SIDE (59 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH
Name: LEFT BSMT (16 s.f.), U:0.490, SHGC: 0.66, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE
[] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
El Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
C-M,
Energy Solutions
3
Energy Cade Inspection Checklist
Property
14309 NEW GARDEN LN
CARMEL, IN 46033
Model: RIVIERA
Community: LEGACY RIDGE 84
LR84 (AS DESIGNED)
LEGACY RIDGE 84
Air Leakage Control
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
Test Status: Blower -door tested
House is air -sealed as to achieve 4,841 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 324.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 432.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors — 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 1 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage {= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C-M,
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes 4
Building Summary
Property
Organization Inspection Status
14309 NEW GARDEN LN
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: RIVIERA
5,446
Community: LEGACY RIDGE 5=
Builder
Conditioned Volume [cu. ft.]
LENNAR HOMES
LR34 (AS DESIGNED)
1
LEGACY RIDGE 84
Single family detached
General Building Information
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq. ft.]
5,446
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
48,408
Total Units in Building
1
Residence Type
Single family detached
Model
RIVIERA
Community
LEGACY RIDGE 84
Climate Zone
5A
Basement Wall��his
A
Name Library type
Height Above Grade Depth Below Grade
C-M,
Energy Solutions
CONDIAMB R-11 Draped, 4ft 1 8 131 Exposed Exterior Conditioned Space
CONDIGAR R-11 Draped, 4ft 1 8 43 Exposed Exterior Conditioned Space
Basement Wall Library List
Name Feet From Wall Top To Insu
R-11 Draped, 4ft 0 4 No 11.00
Slab
Name Library type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing
Masonry Area
BSI.1T Uninsulated 174 Below Grade 0 a 1,712.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction type
Slab Completel�l
Insulated.
Unders lab Insulation
Width [fq
Perimeter Insulation
Depth [ftJ
Perimeter Insulation R Effective R -value
Value
Uninsulated Wood Frame /Other
No
0
0
6 0.00
1
Building Summary
Property
Organization
14309 NEW GARDEN LN
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Model: RIVIERA
Exposed Exterior
Community: LEGACY RIDGE 84
Builder
LENNAR HOMES
LR34 (AS DESIGNED)
LEGACY RIDGE 84
Framed Floor
Name
Library type Car
OVER AMBIENT
R-38, GR1
OVER GARAGE
R-38, GR1
Framed Floor Library List
Name
�A
Effective R -value
R-38, GR1
33.825
Rim Joist
Name
Library Type
CONDIAMB
G1 R-13. R-3.0
COiND1ATTIC
G1 R-13, OSB
CONDIGAR
G1 R-13, OSB
Rim Joist Library List
Name
Effective Insulation R -value
G1 R-13, OSB
10.876
G1 R-13, R-3.0
13.575
C-M
Energy Solutions
Inspection Status
Results are projected
ret R
Floor Grade
SUrraceArea
Location
1.23
Above Grade
14.0 sq. ft.
Exposed Exterior
1.23 Above Grade 428.0 sq. ft. Unconditioned, attached
garage
Surface Area Location
270.6 sq. R. Exposed Exterior
58.0 sq. it
Unconditioned, attached
garage
43.0 sq. It
Unconditioned, attached
garage
E M
Name Library Type Surface Calor Surface Area Location
CONDIAMB G1 R-13 BATT, R-3.0 Medium 2,387.0 sq. ft. Exposed Exterior
CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 270.0 sq. R. Exposed Exterior
2
Building Summary
Property Organization
Inspection
Status
C-MEnergy
Solutions
14309 NEW GARDEN LN TSI Energy Solutions
Results are projected
CARMEL, IN 46033 Matthew Timmons
Model: RIVIERA
Community: LEGACY RIDGE 84 Builder
LENNAR HOMES
LR34 (AS DESIGNED)
LEGACY RIDGE 84
Name Library Type
Surface Calor
Surface Area
Location
CONDIATTIC G1 R-13 BATT, R-3.0
Medium
218.0 sq. ft.
Attic
CONDIGAR G1 R-13 Gar Walls
Medium
387.0 sq. ft.
Unconditioned, attached garage
■
Wall Library List
Name Effective R-value
G1 R-13 BATT, R-3.0 15.12
G1 R-13 Gar Walls 11.141
G1 R-19, R3.02X6 20.217
Glazing
Name Library lype Wall Assignment Basement Wall
Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK U-.31, SHGC-.31 CONDIAMB
❑
0
0
West
174.0 sq. ft.
BACK 2X6 U-.31, SHGC-.31 CONDIAMB 2X6
❑
0
0
West
77.0 sq. 11
BACK 2X6 GD U-29, SHGC-.33 CONDIAMB 2X6
❑
0
0
West
18.0 sq. ft.
FRONT U-.31, SHGC-29 CONDIAMB
❑
0
0
East
127.0 sq. ft.
LEFT BSMT U-d9, SHGC-.66 CONDIAMB
0
0
0
South
16.0 sq. ft.
LEFT SIDE 111-.32, SHGC-.31 CONDIAMB
0
0
0
South
59.0 sq. ft.
RIGHT SIDE 111-.32, SHGC-.31 CONDIAMB
❑
0
0
North
83.0 sq. ft.
RIGHT SIDE BSMT U-.49, SHGC-.66 CONDIAMB
❑
0
0
North
16.0 sq. ft.
3
Building Summary
Property
Organization
Inspection Status
14309 NEW GARDEN LN
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Matthew Timmons
Assignment
Model: RIVIERA
Community: LEGACY RIDGE 84
Builder
20.0 sq. ft.
Exposed Exterior
LENNAR HOMES
LR34 (AS DESIGNED)
0.9 0.75 Medium
LEGACY RIDGE 84
Exposed Exterior
Glazing (Library List
Name
Shgc
U -factor
U-.29, SHGG.33
0.33
8.296
U-.31, SHGC-.29
0.29
0.310
U-.31, SHGG.31
0.31
0.310
U-.32, SHGG.31
0.31
0.320
U-.49. SHGC-.66
0.66
0.490
Skylight
one
Skylight Library List
i
None
C-M,
Energy Solutions
Opaque Door
Name Library Type Wall Assignment Basement Wall
Emittance Solar Surface Color
Surface Area
Location
Assignment
Ab so rp tan ce
FRONT Steel Door CONDlAMB
0.9 0.75 Medium
20.0 sq. ft.
Exposed Exterior
GARAGE Steel Door CONDlGAR
0.9 0.75 Medium
18.0 sq. ft.
Exposed Exterior
Opaque Door Library List
Name Effective U -factor
Steel Door 0.182
4
Building Summary
Property
14309 NEW GARDEN LN
CARMEL, IN 46033
Model: RIVIERA
Community: LEGACY RIDGE 84
LR34 (AS DESIGNED)
LEGACY RIDGE 84
Roof Insulation
Name
Library type
EC'0`,JD
R-38 Blown, GR1
Organization
TSI Energy Solutions
Ma tthew Ti m mon s
Builder
LENNAR HOMES
r Area clay or
P.f.]
2,154
Inspection Status
Results are projected
Tiles
No
Roof Insulation Library List
Name Has Radiant Barrier Effective R -value
R-38 Blown, GR1 No 38268
Whole House Infiltration
Infiltration Measurement Typi
6 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
None Present
4
C-M,
Energy Solutions
Medium 2,154.0 sq. ft. Attic
LightingE101"a
°I Interior Fluorescent °I Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting °I Garage Fluorescent °I Garage LED Lighting
Lighting Lighting Lighting
a to,-- 0 100 0 100
Onsite Generation
None Present
,:I
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
14309 NEW GARDEN LN
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: RIVIERA
Community: LEGACY RIDGE 5=
Builder
LENNAR HOMES
LR34 (AS DESIGNED)
LEGACY RIDGE 84
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name
Air conditioner (2)
Fuel -fired air
distribution (1)
Water Heating (3)
CA13NA042
9155A48080S17
RE350"
Equipment Type: 915SA4808OS17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 95.5 AFUE
Heating Capacity [kBtulh] 78
Use default EAE N0
EAE [kWh] 946
Equipment Type: CA13NA042 M
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 46
g Percent LOaS
0%
100%
0%
100%
0%
a%
100°%
11
Building Summary
Property
14309 NEW GARDEN LN
CARMEL, IN 46033
Model: RIVIERA
Community: LEGACY RIDGE
LR34 (AS DESIGNED)
LEGACY RIDGE 84
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Distribution System
Distribution Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Duct R Value
Supply Duct Area [sq. ft.]
Return Duct Area [sq. ft]
Duct Leakage to Outdoors (CFM25)
Total Leakage
Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1
Duct Location
Percent Supply Area
Percent Return Area
Duct 2
Duct Location
Percent Supply Area
Percent Return Area
Duct 3
Duct Location
Percent Supply Area
Percent Return Area
Duct 4
Duct Location
Percent Supply Area
Percent Return Area
Duct 5
Duct Location
Percent Supply Area
Percent Return Area
Duct 6
Duct Location
Percent Supply Area
Percent Return Area
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
Organization
TSI Energy Solutions
Ma tthew Ti m mon s
Builder
LENNAR HOMES
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
❑.98
Forced Air
Fuel -fired air distribution (1)
Air conditioner (2)
5446
4
30
20
1470.42
1089.2
324
432
Post -Construction
Yes
Conditioned Space
60
60
Attic (well vented, under insulation)
40
40
Conditioned Space
Conditioned Space
0
Conditioned Space
Conditioned Space
0
No
100
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
14309 NEW GARDEN LN
CARMEL, IN 46033
Model: RIVIERA
Community: LEGACY RIDGE 84
LR34 (AS DESIGNED)
LEGACY RIDGE 84
Organization Inspection Status
TSI Energy Solutions Results are projected
Ma tthew Ti m mon s
Builder
LENNAR HOMES
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
166
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
30
Drain Water Heat Recovery?
No
Clothes Dryer
Fuel Type Electric
Cef 2.617
Field Utilization Timer Controls
Asher
Label Energy Rating
764 kWh/Year
Electric Rate
$0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.58frherm
Capacity
2.874
Imef
0.331
Appliances and Controls
M
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Electric
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
769 kWh/Year
C-M,
Energy Solutions