Loading...
HomeMy WebLinkAboutA001.0SUMP w/ CHECK VALVE, VERIFY LOCATIONOPT. EJECTOR PIT AND PUMP AS REQUIRED, VERIFY LOCATIONPROVIDE SEPARATION BETWEEN WATER & SEWER LINES, PER CODE FURNACE PER MECHANICAL PLANS WATER HEATER, PER SPECOPT. WATER SOFTENER, PER SPECRADON VENT PER CODE, VERIFY LOCATION PERIMETER DRAIN, PER SPEC UP 7 RISERS HANDRAIL, PER CODE 1234567 POST & BEAM PER STRUCTURAL PLANS POST & BEAM PER STRUCTURAL PLANS 12345678 \pxql;2/8 FD 4140 SL & EGRESS WELL #4, AS REQUIRED BY CODE\PSEE STRUCTURAL DETAILS OPT\PROUGH IN BATH POST & BEAM PER STRUCTURAL PLANS ADD RISER W/ OPT. 9'-0" POUR \A1;22'-8{\H0.75x;\S1#2;}"\A1;10'-7{\H0.75x;\S1#2;}" \A1;10'-3{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}"\A1;3'-6{\H0.75x;\S1#2;}"\A1;15'-11{\H0.75x;\S1#2;}" \A1;10'-8" \A1;18'-8" \A1;18'-8"\A1;19'-5" \A1;12'-1" \A1;6'-5{\H0.75x;\S1#2;}" \A1;4'-5{\H0.75x;\S1#4;}" \A1;7'-0"\A1;48'-0" - OVERALL \A1;31'-6" \A1;16'-6" \A1;19'-2{\H0.75x;\S3#4;}" \A1;12'-3{\H0.75x;\S1#4;}" \A1;2'-11{\H0.75x;\S3#4;}" \A1;5'-0" \A1;2'-7{\H0.75x;\S1#4;}" \A1;20'-6{\H0.75x;\S1#2;}"\A1;1'-5{\H0.75x;\S1#2;}"\A1;2'-7{\H0.75x;\S1#2;}" \A1;42'-3{\H0.75x;\S1#2;}" LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) LEAD WALL PAST OVERDIG, FIELD VERIFY LOCATION\P(TYP.) \A1;33'-4" \A1;29'-4" \A1;48'-0" - OVERALL \A1;19'-6" \A1;10'-6" \A1;18'-0" \A1;64'-3{\H0.75x;\S1#2;}" - OVERALL \A1;30'-11{\H0.75x;\S1#2;}" \A1;64'-3{\H0.75x;\S1#2;}" - OVERALL \A1;11'-11{\H0.75x;\S1#2;}" \A1;5'-0{\H0.75x;\S1#2;}" \A1;1'-9"\A1;2'-6{\H0.75x;\S1#2;}"\A1;8'-3"\A1;2'-2"\A1;16'-3" \A1;8'-11{\H0.75x;\S1#2;}" \A1;1'-9{\H0.75x;\S1#2;}" \A1;1'-8" \A1;5'-7" \A1;11'-11{\H0.75x;\S1#2;}"\A1;3'-3"\A1;1'-9{\H0.75x;\S1#2;}"\A1;47'-3{\H0.75x;\S1#2;}" TO CORNER \A1;7'-4" \A1;6'-1{\H0.75x;\S1#2;}" \A1;12'-6{\H0.75x;\S1#2;}" 2A2 B.1 1A2 B.1 1A2 B.1 2A2 B.1 3A2 B.2 4A2 B.2 4A2 B.236x60 SHOWER GFI S3S GFIGAS VALVE GFI S 3S 220V S GFI GFI SLAB/UNEXCAVATED (SEE STRUCTURAL PLANS)HVACBASEMENT UNFINISHEDSLAB (SEE STRUCTURAL PLANS)CONCRETE SLABUNEXCAVATED (SEE STRUCTURAL PLANS)PORCHUNEXCAVATED (SEE STRUCTURAL PLANS) 3A2 B.2 A0.01 FOUNDATION - BASEMENTMidwest Zone Office1900 Golf Road - Suite 300Schaumburg, Illinois 60173(c) Copyright 2017 PulteGroup, Inc. PRODUCT MANAGERRick StarkeyVERSION RELEASEDATE:12/12/2016 PROJECT TYPESingle Family SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER ---- Allison II 2377.300Home for * Market Home *, 5581-012004440 Voyageur Way, Carmel, IN 46074BASEMENT FOUNDATION PLANSCALE: 1/4" = 1'-0" (HALF SCALE ON 11x17 PAPER) 05/09/19 William Hohlt