Loading...
HomeMy WebLinkAboutA000.4SCALE:ROOF PLAN1/8" = 1'-0"-SCALE:ROOF PLAN1/8" = 1'-0"- \A1;1'-0"\PTYP.\A1;1'-0"\PTYP. \A1;1'-0"\PTYP.\A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP.\A1;1'-0"\PTYP.\A1;1'-0"\PTYP. \A1;4'-0" \A1;7'-0"\A1;26'-0" \A1;12'-0" 9:12 14:1214:12 9:12 9:12 9:12 4:12 7:12 4:12 4:12 ROOF AREASQ. FT."B"435 ROOF AREASQ. FT."A"2455 ROOF AREASQ. FT."C"309 4:12 10:1210:12 14:1214:12 14:12 4:12 14:12 9:12 9:12 ROOF AREA "A"SQ FTG 2780 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.71 4.63 4.24 50.41 10 0 AT EAVE 5.56 4.63 4.17 49.59 0 60.00 TOTAL (MIN)9.27 9.27 8.40 100.00 3 HIGH - RIDGE VENT 3.71 4.63 4.13 49.75 0 0 33.00 AT EAVE 5.56 4.63 4.17 50.25 0 60.00 TOTAL (MIN)9.27 9.27 8.29 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION GR3G ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "B"SQ FTG 435 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.58 0.73 0.42 50.41 1 0 AT EAVE 0.87 0.73 0.42 49.59 0 6.00 TOTAL (MIN)1.45 1.45 0.84 100.00 3 HIGH - RIDGE VENT 0.58 0.73 0.38 47.37 0 0 3.00 AT EAVE 0.87 0.73 0.42 52.63 0 6.00 TOTAL (MIN)1.45 1.45 0.79 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "C"SQ FTG 309 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.41 0.52 0.56 44.44 0 2 AT EAVE 0.62 0.52 0.69 55.56 0 10.00 TOTAL (MIN)1.03 1.03 1.25 100.00 3 HIGH - RIDGE VENT 0.41 0.52 0.50 41.86 0 0 4.00 AT EAVE 0.62 0.52 0.69 58.14 0 10.00 TOTAL (MIN)1.03 1.03 1.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ELEVATION FH3G ELEVATION FH3G PLOTTED: March 20, 2019 / Annie Lee / 2056-SKYVIEW-IN-WCLY-EL-GR3G.DWG A3-GR3G 3SB.2Gothic Revival3 Car GarageRoof Plan and Attic Ventilation Schedule........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 Joel Hampshire03/01/2016 Left Skyview 2056.300.00.CPM LOT 657 12/11/20181900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office05/07/19 Mike Sheeks