HomeMy WebLinkAboutA000.4SCALE:ROOF PLAN1/8" = 1'-0"-SCALE:ROOF PLAN1/8" = 1'-0"-
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;4'-0"
\A1;7'-0"\A1;26'-0"
\A1;12'-0"
9:12
14:1214:12
9:12
9:12
9:12
4:12
7:12
4:12
4:12
ROOF AREASQ. FT."B"435 ROOF AREASQ. FT."A"2455
ROOF AREASQ. FT."C"309
4:12
10:1210:12
14:1214:12
14:12
4:12
14:12
9:12
9:12
ROOF AREA "A"SQ FTG 2780 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 3.71 4.63 4.24 50.41 10 0
AT EAVE 5.56 4.63 4.17 49.59 0 60.00
TOTAL (MIN)9.27 9.27 8.40 100.00
3
HIGH -
RIDGE VENT 3.71 4.63 4.13 49.75 0 0 33.00
AT EAVE 5.56 4.63 4.17 50.25 0 60.00
TOTAL (MIN)9.27 9.27 8.29 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ELEVATION GR3G
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "B"SQ FTG 435 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.58 0.73 0.42 50.41 1 0
AT EAVE 0.87 0.73 0.42 49.59 0 6.00
TOTAL (MIN)1.45 1.45 0.84 100.00
3
HIGH -
RIDGE VENT 0.58 0.73 0.38 47.37 0 0 3.00
AT EAVE 0.87 0.73 0.42 52.63 0 6.00
TOTAL (MIN)1.45 1.45 0.79 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "C"SQ FTG 309 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.41 0.52 0.56 44.44 0 2
AT EAVE 0.62 0.52 0.69 55.56 0 10.00
TOTAL (MIN)1.03 1.03 1.25 100.00
3
HIGH -
RIDGE VENT 0.41 0.52 0.50 41.86 0 0 4.00
AT EAVE 0.62 0.52 0.69 58.14 0 10.00
TOTAL (MIN)1.03 1.03 1.19 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ELEVATION FH3G ELEVATION FH3G
PLOTTED: March 20, 2019 / Annie Lee / 2056-SKYVIEW-IN-WCLY-EL-GR3G.DWG
A3-GR3G
3SB.2Gothic Revival3 Car GarageRoof Plan and Attic Ventilation Schedule...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
Joel Hampshire03/01/2016
Left
Skyview
2056.300.00.CPM
LOT 657
12/11/20181900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office05/07/19
Mike Sheeks