HomeMy WebLinkAboutA200.0\A1;14'-3"
\A1;1'-4"2/4\A1;1'-10"
WIC9' CLG.UP TRTP
TB
60x30 TUB/SHOWER1R/1S
1R/1S
2/6
\A1;3'-8{\H0.750000x;\S1#2;}"\A1;4'-7"\A1;8'-6{\H0.750000x;\S1#2;}"\A1;2'-0"\A1;1'-7{\H0.750000x;\S1#2;}"\A1;1'-11"BATH 48' CLG.
2/4
SCALE:SECOND FLOOR PLAN1/4" = 1'-0"
OWNER'S SUITE9' CLG.
WIC9' CLG..
BEDROOM 49' CLG..
WIC9' CLG..
LOFT9' CLG..BEDROOM 39' CLG..
BEDROOM 29' CLG..
OWNER'S
RETREAT9' CLG..
\A1;58'-0" - OVERALL \A1;10'-4"\A1;15'-0"\A1;32'-8"
\A1;47'-0"\A1;51'-0" - OVERALL
\A1;10'-0"
\A1;36'-0"
\A1;5'-0"
2/6
2/4
2/6 2/4
1R/1S
2/4
DN 16 RISERS
\A1;4'-2"\A1;7'-6"\A1;7'-6"\A1;3'-7{\H0.750000x;\S1#2;}"
OPEN TO BELOW
1R/1S60x30 TUB/SHOWER
2/6
2/4
1R/1S
1R/1S
WIC9' CLG..1R/1S1R/1S
WIC9' CLG..
BATH 29' CLG..(4) 16" SH
(4) 12" SH
2/4
2/8
\A1;51'-0" - OVERALL
\A1;4'-0"
\A1;13'-2"
\A1;8'-8"
\A1;6'-3{\H0.750000x;\S1#2;}"
\A1;5'-6"
2/42/4
\A1;12'-0"
\A1;3'-5{\H0.750000x;\S1#2;}"
\A1;5'-3{\H0.750000x;\S1#2;}"
\A1;3'-5{\H0.750000x;\S1#2;}"
\A1;11'-9{\H0.750000x;\S1#2;}"
\A1;5'-11"
\A1;6'-1"
60x30 TUB/SHOWER 1R/1S
\A1;8'-1{\H0.750000x;\S1#2;}"
\A1;3'-8"
\A1;9'-1"
\A1;4'-3{\H0.750000x;\S1#2;}"
LINE OF WALL BELOW
\A1;1'-10{\H0.750000x;\S1#2;}"
\A1;1'-6{\H0.750000x;\S1#2;}"2020 FX
2020 FX
12" DROP HDR
1R/1S1R/1S
KNEE WALL w/ CAP @ 42" A.F.F.12" DROP HDR
\pxql;STD. RAIL1A2 B.1
LINE OF WALL BELOW
\A1;1'-6{\H0.750000x;\S1#2;}"
\A1;1'-3"\A1;1'-8{\H0.750000x;\S1#2;}"\A1;1'-11"
\A1;1'-7{\H0.750000x;\S1#2;}"\A1;1'-5{\H0.750000x;\S1#2;}"
\A1;1'-7{\H0.750000x;\S1#2;}"
\A1;3'-5{\H0.750000x;\S1#2;}"
\A1;2'-0"
\A1;1'-7{\H0.750000x;\S1#2;}"\A1;1'-11"
\A1;1'-11"
\A1;2'-0"
\A1;1'-7{\H0.750000x;\S1#2;}"\A1;2'-1{\H0.750000x;\S1#2;}"
\A1;1'-4{\H0.750000x;\S1#2;}"\A1;2'-3{\H0.750000x;\S1#2;}"\A1;3'-1{\H0.750000x;\S1#2;}"\A1;5'-4{\H0.750000x;\S1#2;}"\A1;3'-8{\H0.750000x;\S1#2;}"
\A1;1'-6"\A1;1'-6"\A1;3'-3{\H0.750000x;\S1#2;}"\A1;2'-1"
\A1;8'-6"\A1;6'-1{\H0.750000x;\S1#2;}"\A1;6'-0"\A1;4'-8"
\A1;8'-2{\H0.750000x;\S1#4;}"\A1;3'-5{\H0.750000x;\S3#4;}"\A1;3'-10{\H0.750000x;\S1#2;}"
\A1;3'-0"\A1;3'-1{\H0.750000x;\S1#2;}"\A1;7"
\A1;4'-5{\H0.750000x;\S1#2;}"
\A1;3'-3{\H0.750000x;\S1#2;}"
\A1;4'-3{\H0.750000x;\S3#4;}"
\A1;4'-6{\H0.750000x;\S1#2;}"
\A1;13'-3{\H0.750000x;\S1#2;}"
\A1;6'-5"
\A1;5{\H0.750000x;\S1#2;}"
\A1;3'-1"
\A1;12'-1"
\A1;4'-0"
\A1;3'-6{\H0.750000x;\S1#2;}"
\A1;1'-5{\H0.750000x;\S1#2;}"
\A1;3'-3"
\A1;6'-1{\H0.750000x;\S1#2;}"\A1;10'-8"
\A1;15'-10{\H0.750000x;\S1#2;}"\A1;16'-10"
\A1;19'-3{\H0.750000x;\S1#2;}"
2/4 \A1;5'-3{\H0.750000x;\S1#2;}"\A1;4'-9{\H0.750000x;\S1#2;}"
4020 FX (TEMP)TB
\A1;1'-8{\H0.750000x;\S1#2;}"\A1;1'-10"
\A1;2'-9"
\A1;3'-6{\H0.750000x;\S1#2;}"
\A1;4'-7{\H0.750000x;\S1#2;}"
\A1;2'-2"
2X6 WALL 2X6 WALL
\A1;4'-6{\H0.750000x;\S1#2;}"
\A1;4'-1"
\A1;2'-0"
2A2 B.2
1A2 B.1
2A2 B.2
3A2 B.2
BATH 39' CLG..
\A1;2'-10"\A1;2'-10"
\A1;2'-10"
TB
TB
2/4
2/4
\A1;2'-0"\A1;5"DROPPED CLG.
22"x30" ATTIC ACCESS\A1;4'-4"TR
TP
TR
TB
TR
TP
TR
(2) 3053 SH
2020 FX
3053 SH
3053 SH
\A1;2'-0"
\A1;3'-0"
3053 SH3053 SH3053 SH
12" DROP HDR
34x48 SHOWER
42x60 DROP-IN TUB
\A1;\pxql;27" 2X6 AND 2X4 KNEE WALL w/ CAP, SLOPE {\H0.7x;\S1#2;}" PER FT.
OWNER'S BATH9' CLG..
TP
TR
TR
3053 SH3040 SH3053 SH (2) 3053 SH
\A1;58'-0" - OVERALL\A1;15'-8"\A1;13'-4"\A1;6'-11{\H0.750000x;\S1#2;}"\A1;8'-0{\H0.750000x;\S1#2;}"\A1;14'-0"\A1;7'-0"\A1;7'-0"\A1;3'-5{\H0.750000x;\S3#4;}"\A1;3'-5{\H0.750000x;\S3#4;}"\A1;4'-0"\A1;9'-4"\A1;4'-0{\H0.750000x;\S1#4;}"\A1;4'-0{\H0.750000x;\S1#4;}"
\A1;28'-4"
LINE OF WALL BELOW
BEDROOM 59' CLG.
3053 SH 3053 SH
\A1;3'-3"\A1;10'-3{\H0.750000x;\S1#2;}"\A1;3'-3"\A1;16'-9{\H0.750000x;\S1#2;}"\A1;12'-3"\A1;15'-10{\H0.750000x;\S1#2;}"
1A2 B.11A2 B.1
\A1;1'-9{\H0.750000x;\S1#2;}"
\A1;1'-7{\H0.750000x;\S1#2;}"
\pxql;2x4 FLAT WALL \A1;4{\H0.750000x;\S1#2;}"
FLOORPLAN NOTES\A1;{\LGENERAL SPECIFICATIONS\P\P\pxi-2,l2,t2;}1. ALL ANGLED WALLS (OTHER THAN THOSE AT 90%%D) SHALL BE CONSIDERED TO BE AT 45%%D UNLESS NOTED OTHERWISE\P2. ALL NON-BEARING WALLS TO BE 2x4 STUDS AT 24" O.C. KITCHEN AND PULTE PLANNING CENTER WALLS, WHERE CABINETS ARE TO BE HUNG, SHALL BE FRAMED AT 16" O.C.\P3. PROVIDE A 1-3/8" OR LARGER SOLID CORE WOOD DOOR, SOLID CORE STEEL DOOR OR HONEYCOMB CORE STEEL DOOR, OR 20 MINUTE FIRE-RATED DOOR EQUIPPED WITH A SELF-CLOSING DEVICE BETWEEN GARAGE AND LIVING SPACE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE. \P4. PROVIDE FIRE SEPARATION BETWEEN DWELLING AND GARAGE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P5. PROVIDE {\H0.7x;\S1#2;}" DRYWALL AT WALLS, CEILING AND UNDERSIDE OR STAIR ASSEMBLY ACCESSIBLE SPACE UNDER STAIRS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P6. ALL GLAZING INSTALLED IN HAZARDOUS LOCATIONS AS DEFINED BY THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE SHALL HAVE A PERMANENT DESIGNATION OR LABEL AFFIXED TO EACH PANE OF GLAZING BEARING THE MANUFACTURER'S LABEL SHOWING THE TYPE AND THICKNESS OF GLASS. FOR OTHER THAN TEMPERED GLASS, LABELS MAY BE OMITTED PROVIDED THE BUILDING OFFICIAL APPROVES THE USE OF A CERTIFICATE, AFFIDAVIT OR OTHER EVIDENCE CONFIRMING COMPLIANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P7. ALL BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT NOT LESS THAN 72" ABOVE THE FLOOR PER THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P8. PROVIDE {\H0.7x;\S1#8;}" MAX. SHEATHING WITH TAPED JOINTS AS DRAFT STOP WITH BATT INSULATION FILLING ALL CAVITIES AT EXTERIOR WALLS ADJACENT TO TUBS AND SHOWERS.\P9. ALL REQUIRED GUARDRAILS AND GUARDWALLS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. GUARDS SHALL NOT BE LESS THAN 36" HIGH MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE AND NOT LESS THAN 34" HIGH MEASURED VERTICALLY FROM THE SLOPED PLANE THAT ADJOINS THE TREAD NOSINGS.\P10. ALL REQUIRED HANDRAILS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH 4 OR MORE RISERS. HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34" OR MORE THAN 38" AS MEASURED VERTICALLY FROM THE SLOPED PLANE THAT ADJOINS THE TREAD NOSINGS AND SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL.\P11. BASEMENTS, HABITABLE ATTICS AND ALL SLEEPING ROOMS MUST HAVE AT LEAST ONE EMERGENCY ESCAPE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. THE EMERGENCY ESCAPE MUST HAVE A 5.7 SFCLEAR OPENING AND A SILL HEIGHT OF NO MORE THAN 44" ABOVE FINISHED FLOOR. ESCAPE WINDOWS AT GRADE LEVEL MUST HAVE A MIN. OF 5.0 SF OF OPEN AREA. REQUIRED CLEAR OPENINGS SHALL BE A MINIMUM OF 24" HIGH AND 20" WIDE. EMERGENCY ESCAPES WITH A FINISHED SILL HEIGHT BELOW THE ADJACENT GRADE MUST HAVE A WINDOW WELL AND LADDER IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P12. FOR ADDITIONAL INFORMATION SEE STRUCTURAL DRAWINGS AND NOTES
...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
Joel Hampshire03/01/2016
Left
Skyview
2056.300.00.CPM
LOT 657
12/11/20181900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone OfficePLOTTED: March 20, 2019 / Annie Lee / 2056-SKYVIEW-IN-WCLY-PLAN.DWG
A1
4-2.1Second Floor Plan.4" Exterior Walls05/07/19
Mike Sheeks