Loading...
HomeMy WebLinkAboutA005 - PROPOSED FOUNDATION & FRAMING PLANS1 8'-3 1 /2"7'-11" 20'-8"12'-8"7'-0 1/4" 7'-5" 6 3/4" 9'-9 1 /4" 9'-9 1 /4"7'-5" 7'-0 1/4"6 3/4"1'-4 1/2"1 '-1 1 /2" 3'-4" 10"8'-4" 16'-1 1/4" 6 3/4" EXISTING FINISHED STORAGE ROOM EXISTING PORCH ABOVE NEW CRAWL SPACE EXISTING GARAGE ABOVE POOLHOUSE STORAGE ROOM ABOVE POOLHOUSE PORCH ABOVE HOLD DOWN FOR SERVICE DOOR HOLD DOWN FOR OVERHEAD DOOR 1 8'-3 1 /2"7'-11"11 7/8" TJI @ 16" O.C. 1 3/4" X 11 7/8" LSL LEDGER 1 1/8" X 11 7/8" TJ RIMBOARD R-19 BATT INSULATION AT PERIMETER ADDITION FOUNDATION FRAMING NOTES:ADDITION FOUNDATION &FRAMING NOTES: EXCAVATE & HAUL SPOILS AS NECESSARY FOR NEW ADDITION CRAWL SPACE FOUNDATION. FURNISH & INSTALL NEW 16"W X 8"H CONTINUOUS CONCRETE FOOTINGS TO MINIMUM 32" BELOW FINISH GRADE FOR ADDITION. F/I PERIMETER DRAIN AT NEW FOOTINGS; TIE INTO EXISTING DRAINAGE SYSTEM. F/I NEW 8" CMU STEM WALLS AT NEW FOOTINGS. F/I 2" RIGID FOAM INSULATION AT INSIDE FACE OF NEW CRAWL SPACE FOUNDATION WALLS & 6 MIL VAPOR BARRIER W/ TAPED JOINTS. FILL AT FOUNDATION OVERDIG AS NECESSARY. F/I 2X4 TREATED SILL PLATES W/ SILL SEAL AT NEW ADDITION STEM WALLS. F/I 11 7/8" I-JOISTS @ 16" O.C. W/ 3/4" TONGUE & GROOVE OSB SUBFLOOR AT NEW ENTRY HALL & BATHROOM. F/I R-19 BATT INSULATION AT NEW FLOOR FRAMING PERIMETER POOLHOUSE FOUNDATION NOTES:POOLHOUSE FOUNDATION NOTES: EXCAVATE & HAUL SPOILS AS NECESSARY FOR NEW POOLHOUSE STORAGE ROOM & PORCH FOUNDATIONS. FURNISH & INSTALL NEW 16"W X 8"H CONTINUOUS CONCRETE FOOTINGS TO MINIMUM 32" BELOW FINISH GRADE FOR STORAGE ROOM FOUNDATION. F/I (5) 18"ø X 32"D CONCRETE PIER FOOTERS FOR NEW POOLHOUSE PORCH POSTS. F/I NEW 8" CMU STEM WALLS AT NEW STORAGE ROOM FOOTINGS. HOLD DOWN STEM WALLS AT OVERHEAD DOOR & SERVICE DOOR. FILL AT FOUNDATION OVERDIG AS NECESSARY. #1 of 33 Date: 05.02.19 Sheet: Revision: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.McBroom ResidenceOutdoor Living AdditionFred & Carin McBroom14556 Jackie Spring Ct.Carmel, Indiana 46033Approved By: Date: 5 FINAL Jordan Stocklin Designer jstocklin@caseindy.com Dave Null Lead Designer dnull@caseindy.com PROPOSED FOUNDATION & FRAMING PLANS SCALE: AS NOTED FOUNDATION PLANAA SCALE: 1/8" = 1' ADDITION FLOOR FRAMING PLAN BB SCALE: 1/4" = 1' POOLHOUSE ROOF TRUSS PLAN CC NOT TO SCALE 05/16/19 Adam Schriner