HomeMy WebLinkAboutA012 - POOLHOUSE ELECTRICAL PLANR
WP
WP
WP WPWP
R
R
R
EP
WP
WP
WP
WP
2'-6"
POOLHOUSE
PORCH
POOLHOUSE
STORAGE
CLG. HEATER
CLG. HEATER CLG. HEATER
CLG. HEATER
TV WIRE CHASE
NEW
PHOTOCELL
90" A.F.F.
90" A.F.F. 90" A.F.F. 90" A.F.F.
12" A.F.F.
90" A.F.F.
12" A.F.F.
12" A.F.F.60" A.F.F.12" A.F.F.
NEW PANEL
CEILING
DM
R
SD
R NEW 6" LED FAN/CAN
LEGEND-ELECTRICAL
LIGHTING
NEW 6" LED CAN
SWITCHES
COMMUNICATION
MISCELLANEOUS
SMOKE DETECTOR
EXISTING SMOKE DETECTORS TO BE HARDWIRE
WITH BATTERY BACKUP; UPDATE PER CODE
ALL WORK TO BE CONFORM TO THE NEC AND
ALL LOCAL APPLICABLE CODES.
EXACT DEVICE LOCATIONS SUBJECT TO JOB
CONDITIONS.
METER LOCATION TO BE DETERMINED BY
LOCAL UTILITY COMPANY.
GENERAL NOTES
OUTLETS
NEW OUTLETS
DIMMER SWITCH (ROCKER)
SWITCH (ROCKER)
WHITE OUTLET & SWITCH COVER
PLATES TO MATCH EXISTING IN HOME
NEW WALL MOUNT
FIXTURE
-
SWITCHES TO BE ROCKER-STYLE TO
MATCH EXISTING IN HOME
NEW PENDENT
FIXTURE
NEW BARE BULB
FIXTURE
EXISTING OUTLETS
TO REMAIN
NEW HOMEOWNER
PROVIDED FLOOD LIGHT
NEW CEILING FAN
EXISTING FIXTURE
TO REMAIN
ELECTRICAL NOTES:ELECTRICAL NOTES:
POOLHOUSE STORAGE ROOM:
FURNISH & INSTALL NEW SUBPANEL INSIDE POOLHOUSE STORAGE ROOM.
F/I (2) NEW BARE BULB FIXTURES ON SINGLE-POLE SWITCH AS SHOWN ON
PLANS.
F/I (2) NEW EXTERIOR COACH LIGHTS AT NEW OVERHEAD DOOR ON
PHOTOCELL CONTROL FACING WEST AS SHOWN ON PLANS.
INSTALL (2) NEW H.O. PROVIDED FLOOD LIGHTS NEAR SOFFIT AT NORTH
CORNERS OF STORAGE ROOM AS SHOWN ON PLANS. CONFIRM
LOCATIONS W/ H.O. PRIOR TO INSTALLATION.
F/I (4) NEW GFCI DUPLEX WALL RECEPTACLES & (1) NEW GFCI DUPLEX
CEILING RECEPTACLE AS SHOWN ON PLANS.
F/I (1) NEW GFCI DUPLEX RECEPTACLE W/ WEATHERPROOF COVER
ADJACENT TO NEW OVERHEAD DOOR AS SHOWN ON PLANS.
POOLHOUSE PORCH:
F/I (4) NEW 6" RECESSED LED CAN LIGHTS ON NEW SINGLE-POLE SWITCH
W/ WEATHERPROOF COVER AS SHOWN ON PLANS.
F/I (1) NEW CEILING FAN ON NEW SINGLE-POLE SWITCH W/
WEATHERPROOF COVER AS SHOWN ON PLANS.
F/I (4) NEW GFCI DUPLEX RECEPTACLES W/ WEATHERPROOF COVERS ON
WALLS INSIDE POOLHOUSE PORCH AT 12" A.F.F. AS SHOWN ON PLANS.
F/I (1) NEW GFCI DUPLEX RECEPTACLE W/ WEATHERPROOF COVER &
WIRE CHASE ON WALL INSIDE POOLHOUSE PORCH AT 60" A.F.F. FOR H.O.
PROVIDED WALL-HUNG TV. CONFIRM LOCATION W/ H.O. PRIOR TO
INSTALLATION.
F/I (5) NEW GFCI DUPLEX RECEPTACLES W/ WEATHERPROOF COVERS ON
INSIDE FACE OF POOLHOUSE PORCH HEADERS AT 90" A.F.F. CONFIRM
LOCATIONS W/ H.O. PRIOR TO INSTALLATION.
F/I (4) NEW 240V ROUGH-IN LOCATIONS IN CEILING ON SINGLE-POLE
SWITCH AS SHOWN ON PLANS FOR FUTURE H.O. PROVIDED INFRARED
HEATERS.
#1
of
33
Date:
05.02.19
Sheet:
Revision:
www.caseindy.com
99 E. Carmel Drive, Suite 100
Carmel, Indiana 46032
317.846.2600 317.846.2601(f)
These drawings have been
prepared by Case Design &
Remodeling solely for its use and
should not be reproduced or relied
upon by any other parties.
Dimensions shown or scaled are
subject to change per actual job
condition and must be verified.
Materials are to be supplied as
specified as equal or standard
when not uniquely specified.
Installed materials may vary in
appearance from drawings.
Reference manufacturer's product
data for actual appearance and
specifications.McBroom ResidenceOutdoor Living AdditionFred & Carin McBroom14556 Jackie Spring Ct.Carmel, Indiana 46033Approved By:
Date:
12
FINAL
POOLHOUSE ELECTRICAL PLAN
SCALE: 1/4" = 1'
Jordan Stocklin
Designer
jstocklin@caseindy.com
Dave Null
Lead Designer
dnull@caseindy.com
#2 05.16.19
05/16/19
Adam Schriner