HomeMy WebLinkAboutA013 - ADDITION ROOF PLANUP 1 9'-2 3/8"8'-9 7/8"2/12 SLOPE NEW SHINGLE ROOF NEW METAL ROOF ADDITION ROOF ADDITION ROOF NOTES: FURNISH & INSTALL ICE & WATER SHIELD OVER ENTIRE METAL ROOF AREA. F/I FLASHING/STEP FLASHING ALONG WALLS. F/I METAL DRIP EDGE AT RAKE & EAVE TO MATCH NEW METAL ROOFING. F/I STANDING SEAM METAL ROOF AS SHOWN ON PLAN. F/I 6" SEAMLESS ALUMINUM GUTTERS & (1) NEW 3"X4" DOWNSPOUT TO MATCH EXISTING AS CLOSELY AS POSSIBLE AT NEW GUTTER. RELOCATE (1) EXISTING DOWNSPOUT TO ALTERNATE LOCATION AT EXISTING GUTTER. #1 of 33 Date: 05.02.19 Sheet: Revision: www.caseindy.com 99 E. Carmel Drive, Suite 100 Carmel, Indiana 46032 317.846.2600 317.846.2601(f) These drawings have been prepared by Case Design & Remodeling solely for its use and should not be reproduced or relied upon by any other parties. Dimensions shown or scaled are subject to change per actual job condition and must be verified. Materials are to be supplied as specified as equal or standard when not uniquely specified. Installed materials may vary in appearance from drawings. Reference manufacturer's product data for actual appearance and specifications.McBroom ResidenceOutdoor Living AdditionFred & Carin McBroom14556 Jackie Spring Ct.Carmel, Indiana 46033Approved By: Date: 13 FINAL Jordan Stocklin Designer jstocklin@caseindy.com Dave Null Lead Designer dnull@caseindy.com ADDITION ROOF PLAN SCALE: 1/4" = 1' 05/16/19 Adam Schriner