HomeMy WebLinkAboutL100 2nd Floor Life Safety2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CODE SUMMARY SCOPE OF WORK PREVIOUS USE OF SPACE OFFICE REMODEL OF PREVIOUSLY BUILTOUTOFFICE SPACE BUSINESS) OCCUPANCY CLASSIFICATION B(USINESS) CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA 27,950 SF/FLOOR X 3 STORIES = 83,850 SF TOTAL PROJECTAREA 4,738 SF OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUR LOAD GEN. OFFICE 4,738 SF 100 48 TOTAL OCCUPANTS IN PROJECTAREA 48 NUMBER OF EXITS REQUIRED:I PROVIDED:2 SPRINKLER SYSTEM(YES/NO) YES- EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 27,950 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS OF REQUIRED) N/A ASHRAE 90.1 SUMMARY EXEMPT (SEE REFLECTED CEILING PLAN) BUILT BEFORE 19782 NO BUILDING CONSTRUCTION TYPE ILA LEGEND EP EXISTING ELECTRICAL PANEL LOCATION EJ( EXISTING EXIT. BUILDING STAIR LOCATION FE I FF FIRE EXTINGUISHER ® EXITSIGN — — — TRAVEL DISTANCE O NIGHT LIGHT/EMERGENCY LIGHTING NLEL RELEASED FOR CONSTRUCTION Subject to compliance with all regulalions of State and meal Codes City of Camel �VT�'�B*S41WML_ DATE: 07/01/19 AREA NOT IN CONTRACT AREA OF WORK GENERAL NOTES H. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT, PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. LIFE SAFETY PLAN 0 4' 8' 16, N r THIS DRAWING, AND THE IDEAS, IESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC-, AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR CONSENT OF SCH07 DESIGN. VCO CV B L� Z 0 ' 0 r r Cl ZNQ W Lu o C ~ Z Lu � YZF CL < z z Q Z7r � L LL de L I Q O ISSUE DATE DESCRIPTION 05.02.19 REVIEW SET 05.06.19 PERMITSET REVISIONS ARK DATE DB DESCRIPTION H 80I �_ No. AR10700017 , c STATE OF �. TFRED PRD� PROJECT NUMBER 2019.187 PROD. MGR DRAWN BY ACMi CB 2ND FLOOR LIFE SAFETY L100