HomeMy WebLinkAboutA121 2nd Floor Elec & Reflected CeilingELECTRICAL LEGEND
ME
NEW CONSTRUCTION EXISTING TO REMAIN
D@
POWER OUTLET, DUPLEX
POWER OUTLET, DUPLEX
POWER OUTLET
POWER OUTLET
QUADRUPLEX
QUADRUPLEX
®
JUNCTION BOX
J
0
JUNCTION BOX
OCEILING
MOUNTED
CEILING MOUNTED
JUNCTION BOX
JUNCTION BOX
®
BOX, BLANK COVER PLATE
QH
BOX, BLANK COVER PLATE
®
BOX,OPEN
QO
BOX, OPEN
P
PROVIDE JUNCTION BOX
P
POWER AND DATA POLE
ABOVE CEILING FOR
O
POWER POLE
CONNECTION. POWER
POLE BY OTHERS.
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
F&19
AND DATA, FLUSH
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
JUNCTION BOX AND
J q
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
I®
OUTLET (PROVIDE BOX
q
AND PULL STRING ONLY)
OUTLET
DIED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42'
HEIGHT OF ELECTRICAL
OR DATA DEVICE
ELECTRICAL PLAN NOTES
E01 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN, COORDINATE EXACT
LOCATION WITH TENANT.
E02 NO ELECTRICAL WORK IN THIS AREA, EXISTING TO REMAIN.
E03 PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS
FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU
DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO
ORDERING.
E04 PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR
FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANTS SECURITY CONTRACTOR. SEE DOOR SCHEDULE
FOR MORE DETAILS.
E05 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED,
DAVE
OFFICE
220
AREA NOT IN CONTRACT
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 07/01/19
I I
UP
P L_J
GENERAL ELEC. NOTES
I. TENANTS FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO BE INSTALLED I E' MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS, ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
T-NANCY
CINDA
MATT
OFFICE
PRICE1_0_
2
_X8 II
E02
r KRISTIN
TIM
8x8 'I
______ �J
OFFICE
—
OFFICE
1
JUDA
OFFICE
217 w I�{{I
° i a�
-■1?
Till
III
III
�.I�.gR.r
•-cY Fl.:
I�
♦I
I
!II
PSJ
•
•
Y�
PIIb]
IU
III
I
I/
V 111
APRIL
OFFICE
MISTI
OFFICE
STEPHANIE
OFFICE
E02
CHRIS W
OFFICE
rm
KURT
OFFICE
17771
E02
ELECTRICAL PLAN
0 2' 4' 8' 16,
RCP LEGEND
NEW OR RELOCATED EXISTING TO REMAIN
FEERLIGHT FIXTURE, 2'x4',
IJ
LIGHT FIXTURE, 2'x4',
FLUORESCENT,
FLUORESCENT,
PRISMATIC
PRISMATIC
❑LIGHT FIXTURE, 2'X2',
LIGHT FIXTURE, 2'X2',
FLUORESCENT.
FLUORESCENT.
PRISMATIC
PRISMATIC
LIGHT FIXTURE, 2'x2',
LIGHT FIXTURE, 2'x2'
FLUORESCENT.
FLUORESCENT.
INDIRECT
INDIRECT
0 RECESSED LIGHT FIXTURE
ii
RECESSED LIGHT FIXTURE
WALL SCONCE UGHT
WALL SCONCE LIGHT
01 FIXTURE
^'
FIXTURE
PROVIDED BY TENANT,
®
UGHT FIXTURE.
® CONTRACTOR TO INSTALL
PENDANT
IN INDICATES NIGHT UGHT
INDICATES NIGHT LIGHT
LOCATION
LOCATION
® EXIT LIGHT FIXTURE
EXIT LIGHT FIXTURE
EMERGENCVLIGHT
EMERGENCY LIGHT
FIXTURE
FIXTURE
$N LIGHT SWITCH
$
UGHTSWITCH
$N3 LIGHT SWTCH.&WAY
$3
UGHTSWITCH,&WAY
$ND LIGHT SWITCH, DIMMER
$D
UGHT SWITCH, DIMMER
SNP SWITCH, PROJECTOR
$P
SWITCH, PROJECTOR
SCREEN
SCREEN
$NG SWITCH, GARBAGE
$G
SWITCH, GARBAGE
DISPOSAL
DISPOSAL
LIGHTCIRCUIT
......
UGHTORCUIT
CEILING GRID,
-
IIk CEILING GRID,
SUSPENDED, 2'x4
SUSPENDED, 2'x4'
CEILING GRID,
T__T__k
CHUNG GRID,
SUSPENDED, 2'x2
SUSPENDED, 2x2'
CEILING GRID,
SUSPENDED, 4 x4 TEES
TO COMPLETE GRID
ICDUN
I SUSPENDED, 4 'xd'
GYPSUM BOARD
CEILING
❑EXISIING/RELOCATED
DIFFUSER LAYJN, 2'x2'
®
DIFFUSER, LAWN, 2'x2'
MATCH EXISTING
REMAINING
EXISTING/RELOCATED
C:2�1
DIFFUSER, LAYJN, 1'x4'
DIFFUSER, LAY -IN, 1X4
EXISTING/RELOCATED
m
DIFFUSER, LAYJN, 4'k4'
DIFFUSER, LAY -IN, 4N4'
® EXHAUST FAN, 2'x2'
�
EXRIIN G EXHAUST FAN,
EXIS
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND
CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
RELOCATE DIFFUSERS &
GENERAL RCP NOTES
ww
I- REUSE EXISTING CEILING GRID AND TILE UNLESS07HERWISE
NOTED. EXISTING GRID IS 2'x4'AT 8'-0" UNLESS OTHERWISE
NOTED. TILES ARE 2$4' SECOND -LOOK ACOUSTICAL LAY IN
TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY
DAMAGED TILES WITH NEW TO MATCH EXISTING.
2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE
POSSIBLE TO CREATE UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS
REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS
OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE
ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN
RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH
PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH
DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO
INSTALLATION, FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS "NEW OR
RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS
LOCATION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN
INTENT IS LESS THAN 50%OF THE LIGHTS ARE ACTUALLY BEING
REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE
SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET
ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS
RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS
REQUIRED TO MEET ASTRAL 90.1, CONTRACTOR MUST NOTIFY
SDI.
5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE
OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH
ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE
BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUI RED, OR
RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI).
EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE.
6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT
ON PLAN.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND
IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS
LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL
OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE
CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE
BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE
PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
8. PROVIDE SEPARATE PRICE FOR NEW 2X4 METALUX LED INDIRECT
LIGHTSTHROUGHOUT. PRICE TO INCLUDE DIMMER SWITCH IN
ALL LOCATIONS.
MECHANICAL DIFFUSER RELOCATION_
Al zl 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
AREA NOT IN CONTRACT
❑ AREA OF WORK
MECHANICAL NOTES
I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS, NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENTARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
RCP PLAN NOTES
R01 CONTROL ENTRY 201, OPENOFFICEAREA, HUDDLE222, AND
CORRIDOR LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION.
CONVERT EXISTING SWITCH AS REQUIRED AND PROVIDE MULTIPLE
SWITCHES AS REQUIRED.
R02 NO CEILING/LIGHTING WORK IN THIS LOCATION, EXISTINGTO
REMAIN.
I
k
IN 11
I
I �`
[
OI N I11 r:
M
PIH
REFLECTED CEILING PLAN N
0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO SE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
� Z
O�
O
H
a—
ZNQ
W
Lu
o
C
~
Z
. w
V
F
<
�-
z
C
Z
z
Q
C/7
Z
CLLJ
Z
`J n
Q
N
2
ISSUE
DATE
DESCRIPTION
OS.02.19
REVIEW SET
OS.06.19
PERMITSET
REVISIONS
ARK
DATE
DS
DESCRIPTION
H 80�_
No.
70 AR10700017 ,
STATE OF �.
TFRED PR��
PROJECT NUMBER
2019.187
PROD. MGR DRAWN BY
ACWCB CB
2ND FLOOR
ELECTRICAL PLAN/
REFLECTED
CEILING PLAN
A121