Loading...
HomeMy WebLinkAboutHSM 024 - Plot Plan"BASE HOUSE STANDARD FEATURES" MODEL: GENEVA 8' FULL BASEMENT - NO WINDOW WELLS 2 CAR COURTYARD 5'X7' DECK "SELECT D FEATURES" ELEV C01 - RIG HAND BRICK WRAP 14'X1 1XCONCRETE PATIO (1) 4'X4' WINDOW WELL ® = Proposed Grade = Drainage Flow —_°— = Proposed Silt Fence Note: Contractor should verify sump pit location with Field Manager, Flood Hazard Note: Lot Number 24 lies within that Special Flood Hazard Zone "X" per the scaled location on the Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel #18057CO208G, dated November 19, 2014). Note: LOT # 24 ±85482 SF PAD 848.4 PER PLAN MFFE 849.0 PER PLAN MFPG 848.7 PER PLAN • Cone Ratwork Sq. Ft = t1,104 Public Walk Sq Ft = ±325 Sod Sq Yds = t151 Seeding Sq Ft = t2,947 " (Drive, Apron, 3' Walk, Patio, Stoops) (PORCH NOT INCLUDED) This document has been prepared for the benefit of the parties indicated hereon, for the express use of obtaining a residential building permit. This document has been prepared and based upon the construction documents, record drawings, and additional information prepared for this development by others. This document is not based upon a field survey and Coor Consulting does not warrant the accuracy or completeness of this information. Note: The lowest elevation to have gravity sanitary sewer service must be more than one (1) foot above the lowest top of casting elevation of either the first upstream or downstream manhole on the main line sewer to which the connection is made. Note Manholes must remain accessible and at grade at all times. Note: Gar. FFE = 848.9 1 st Fir FFE = 850.7 TOW = 849.7 Bsmt FFE = 841.9 Drive Slope =19.0% 45 7 L)HP p0' cc cTM SEIN 651 r- 9' S5b 48,9 O SUMP Q�T W � r O LP R v z �o' 5.2' 15 s.S. D ,E, 1 �nm ]ir @d HOMh ogal c-�"_09' Note: Minimum Front Yard - 15' Minimum Side Yard - 0' Minimum Between Bldgs - 6' Aggregate Minimum - 10' Minimum Rear Yard - 20' STM SH TC=845.01 15' D1&�.�• � � 2p B.S•� GStyeVA COMMON AREA "D" S.S.D.&U.E o� w PORCH rn 0 HSM 14 --3 z3.5g' SAN MH 6 S, ' TC=846.23 15' 12' cp{111c Ilk" E 5 W ALK HSM 15 APRo� �- x c,sRBwrss� 12.0' U SAN MH TC=848.39 1 47 RIW (��,�c_�c� 50 -- Contractor should verify site specific information depicted hereon with the approved construction plans for this development in regards to sidewalk and handicap ramp placement, widths, and construction. Contractor should verify site specific information in regards to erosion control placement and materials. Also. Contractor should reference Architectural plans for foundation orientation and dimensions. The contractor/owner should verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, Corp.; failure to do so would result in the contractor/owners assumption of liability. 001r, C�OC �aUUnno) k<53U)nd �m@TdOC�- 0 c� o p o T� a® In Note: Unless otherwise stated hereon, no information pertaining to but not limited to, fluctuating water tables elevations, soil types, and conditions within the building areas of this development have been provided andlor referenced on said documents. With the excavation of the proposed structure foundations, certain care and observations should be made in regard to such conditions as soil types and fluctuating water tables. During the excavation process should any unsuitable soils or ground water be witnessed, the builder shall be immediately notified for further examination and consultation. At the builders discretion, additional construction techniques may be necessary to alleviate future problems. HERITAGE AT SPRINGMILL SECTION 2 P.C. 5, SLIDE 728 NSTR. #2017047160 LOT # 24 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA 458 HERITAGE TERRACE (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 LANE DATE: 06/11/19 JOB #2017-055.024 REVISIONS:1 CARMEL, IN 46032 PLOT PLAN Prepared For: *PulteGroup Pulte Homes of Indiana