HomeMy WebLinkAboutSHW 003 - Plot Plan"BASE HOUSE STANDARD FEATURES"
MODEL: CROIX
SLAB FOUNDATION
2 CAR FRONT ENTRY GARAGE
7'X5' DECK
"SELECTED FEATURES"
ELEV CT21H - LEFT HAND
9' FULL BASEMENT
BRICK WRAP
GOLF CART STORAGE
(1)4'X4' WINDOW WELL
NOTE:
Minimum Front Yard - 20'
Minimum Side Yard - 5710' AGG
Minimum Rear Yard - 25'
0 = Proposed Grade
= Drainage Flow
= Overflow Route
WATER LINE
SW 404
SAN MH
TC=918.56
LOT # 3
±13,457 SF
PAD 919.6 PER PLAN
MFFE 920.2 PER PLAN
MFPG 920.2 PER PLAN
MLAG 919.7 PER PLAN
Note:
Contractor should verify sump
pit location with Field Manager.
STM INLET
TC=917.50
Note:
The lowest elevation to have gravity sanitary
sewer service must be more than one (1) foot SW 403
above the lowest top of casting elevation of SAN MH
either the first upstream or downstream manhole TC=917.99
on the main line sewer to which the connection
is made.
Note:
Manholes must remain accessible
and at grade at all times.
Note:
Contractor should verify site specific information depicted hereon with the
approved construction plans for this development in regards to sidewalk
and handicap ramp placement, widths, and construction. Contractor
should verify site specific Information in regards to erosion control
placement and materials. Also, Contractor should reference Architectural
plans for foundation orientation and dimensions.
The contractorlowner should verify existing conditions prior to
construction. Any varying field conditions or any discrepancy with the
information contained hereon should be Immediately reported to COOR
Consulting & Land Services, Corp.; failure to do so would result in the
contractorlowners assumption of liability.
MD�Ung 2 D�a�d OGD,
c� o T p o p b o o c�
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 06/10/19 JOB #2016-080.003 REVISIONS:1
Gar. FFE = 920.2
1st Flr FIFE = 922.0
TOW = 921.0
Bsmt FIFE = 912.2
Drive Slope = ±9.6%
Llmum(@d aorM
NJ&os-aa T u = 00
` Conc Flatwork Sq. Ft = t767
Public Walk Sq Ft = t323
Sod Sq Yds = ±214
Seeding Sq Ft = t7,867
• (Drive, Apron, T Walk, Patio, Stoops)
(PORCH NOT INCLUDED)
STM BH
TC=915.30
Flood Hazard Note:
Lot Number 3 lies within Flood Hazard Zone "X" per the scaled location on
the Flood Insurance Rate Maps for Hamilton County, Indiana (Community
Panel #18057CO205G, dated November 19. 2014).
Note:
Unless otherwise stated hereon, no information pertaining to but not limited
to, fluctuating water tables elevations, soil types, and conditions within the
building areas of this development have been provided andlor referenced
on said documents. With the excavation of the proposed structure
foundations, certain care and observations should be made in regard to
such conditions as soil types and fluctuating water tables. During the
excavation process should any unsuitable soils or ground water be
witnessed, the builder shall be immediately notified for further examination
and consultation. At the builders discretion, additional construction
techniques may be necessary to alleviate future problems.
Note:
This document has been prepared for the benefit of the parties indicated
hereon, for the express use of obtaining a residential building permit.
This document has been prepared and based upon the construction
documents, record drawings, and additional Information prepared for this
development by others. This document is not based upon a field survey and
Coor Consulting does not warrant the accuracy or completeness of this
Information.
SHADOW WOOD PLOT PLAN
P.C. 5, SLIDE 730
Prepared For:
INSTR # 2017048049
LOT # 3 *PulteGroup
14497 CARLOW RUN
CARMEL, IN 46074 Pulte Homes of Indiana