HomeMy WebLinkAboutRecessed Drawing- IndianaKAYAK POOLS
RECESSED ISTALLATION
ENG IEERING DESI GN
Design Code:
References:
2003 International Residential Code
AISC Manual of Steel Construction, ASD, Ninth Edition
Manual fr Engineered Wood Construction, ASD, 2001 Edition
National Design Specifications fr Wood Construction, 2001 Edition
Permanent Wood Foundations Design & Construction Guide, Souther Pine Council
2000
Material Specifications:
Treated Plywood shall be APA rated Sheathing: Exposure 1 marked APA series V-600, or
Exterior marked APA series V-611. Minimum thickness 23/32" with a Span Rating of 48/24.
Face grain shall run perpendicular to studs.
Treated Lumber shall be preservative treated Grade No. 1 or No. 2.
Fasteners fr treated lumber shall be stainless steel screws.
Soil Properties:
It is assumed that the soil at the site of the Installation is suitable fr the intended use. The
minimum soil properties suitable fr this installation will include clay or granular soils having an
allowable bearing capacity of 3000 pounds per square fot (psf.
Suitable clay soils will include firm or stiff clays.
Suitable granular soils will include medium dense sands and dense sands.
Unsuitable soils would include: silts, loose sands, and soſt clays.
It is recommended that the installer dig at least one test hole, 4' deep, at the site to verif the
suitability of the soil.
1/7
06/26/19
David Rutti
06/26/19
David Rutti
06/26/19
David Rutti
06/26/19
David Rutti
06/26/19
David Rutti
06/26/19
David Rutti
06/26/19
David Rutti