HomeMy WebLinkAboutGN - Zeronik_Spear TSI Certificate (1)487 JACKSONS GRANT VLVD CARMEL, IN 46032 Builder: OLD TOWN DESIGN GROUP Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-13 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.3, SHGC: 0.27 Building Features Duct Supply R-20.0, Return R-20.0 Duct Leakage to Outside 228.0 CFM @ 25Pa Total Duct Leakage 304.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric - 13 SEER Water Heating Water Heater • Natural Gas • 0.64 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 5/28119 at 10:44 AM Ekotrope RATER - Version 3.1.1.2181 2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.