Loading...
HomeMy WebLinkAboutSHW 006 - Plot Plan"BASE HOUSE STANDARD FEATURES" MODEL: CROIX SLAB FOUNDATION 2 CAR FRONT ENTRY GARAGE 3'X3' CONCRETE STOOP "SELECTED FEATURES" ELEV CT2H - RIGHT HAND BRICK WRAP COVERED PATIO NOTE: Minimum Front Yard - 20' Minimum Side Yard - 5'110' AGG Minimum Rear Yard - 25' = Proposed Grade = Drainage Flow = Overflow Route SW 403 SAN MH TC=917.99 LOT # 6 +11,053 SF PAD 919.6 PER PLAN MFFE 920.2 PER PLAN MFPG 920.2 PER PLAN MLAG 919.7 PER PLAN SW _ STATE OF Gar. FFE = 920.2 1st Fir FFE = 921.0 TOW = 921.0 Bsmt FFE = NIA Drive Slope = t6.2% • Conc Flatwork Sq. Ft = ±988 Public Walk Sq Ft =±390 Sod Sq Yds = ±201 Seeding Sq Ft = #5,537 " (Drive, Apron, 3' Walk, Patio, Stoops) (PORCH NOT INCLUDED) STMI MH N HY y'` 148.60' TC=916.70 1.0' f1 5. J O uj SW 402 o x c j SAN MH h� Ld TC=918.90 J �Vti 3' WALK ry I X ILUO 1a u�i l! CO1N 'jai \ 'P O I "�' L — 11 �� z Goo b0 _ I ti Z �/ moo �a�a" I 0 UQ OC7Z oOJ O 67.57' / L L2J 52.1' ff END SECTION 160.02' 6 5 INV=916.70 LAKE #1 WATER LINE 9.4. P.=909.50 106N.YR.=913.38 Note: The lowest elevation to have gravity sanitary sewer service must be more than one (1 )foot above the lowest top of casting elevation of either the first upstream or downstream manhole on the main line sewer to which the connection is made. Note: Manholes must remain accessible and at grade at all times. Note: G1 AS I-oT Contractor should verify site specific Information depicted hereon with the approved construction plans for this development in regards to sidewalk and handicap ramp placement, widths, and construction. Contractor should verify site specific information in regards to erosion control placement and materials. Also, Contractor should reference Architectural plans for foundation orientation and dimensions. The contractor/owner should verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting 8 Land Services, Corp.; failure to do so would result in the contractorlowners assumption of liability. o D�a�d 00�o9 p �a � n o� Flood Hazard Note: Lot Number 6 lies within Flood Hazard Zone "X" per the scaled location on the Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel #18057CO205G, dated November 19, 2014). Note: Unless otherwise stated hereon, no information pertaining to but not limited to, fluctuating water tables elevations, soil types, and conditions within the building areas of this development have been provided andtor referenced on said documents. With the excavation of the proposed structure foundations, certain care and observations should be made in regard to such conditions as soil types and fluctuating water tables. During the excavation process should any unsuitable soils or ground water be witnessed, the builder shall be Immed lately notified for further examination and consultation. At the builders discretion, additional construction techniques may be necessary to alleviate future problems. Note: This document has been prepared for the benefit of the parties indicated hereon, for the express use of obtaining a residential building permit. This document has been prepared and based upon the construction documents, record drawings, and additional information prepared for this development by others. This document Is not based upon a field survey and Coor Consulting does not warrant the accuracy or completeness of this information. SHADOW WOOD P.C. 5, SLIDE 730 INSTR # 2017048049 LOT # 6 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 14479 CARLOW RUN DATE: 06/04/19 JOB #2016-080.006 REVISIONS: CARMEL, IN 46074 PLOT PLAN Prepared For: Pu lte Pulte Homes of Indianal