Loading...
HomeMy WebLinkAboutA000.3\A1;5'-4" \A1;2'-7" \A1;8{\H0.750000x;\S1#4;}"\A1;4"\A1;4" DORMER DETAIL 9" CROSSHEADTRIM BOARD AROUND WINDOW SCALE 1/4" = 1'-0"PORCH ELEVATIONS LEFT PORCH FRONT PORCH RIGHT PORCH2" CORNER BOARD (TYP)SIDING PER COMM. SPECS (TYP) BRICK WAINSCOT, PER SPEC.T.O. FOUNDATIONT.O. FLOOR \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. 8" SQUARE COLUMN, PER SPEC 10" TRIM, PER SPEC ROOF SHINGLES, PER SPEC SCALE:REAR ELEVATION1/8" = 1'-0"- HORIZONTAL SIDING, PER SPEC \A1;1'-1"\A1;1'-1"\A1;2'-4{\H0.750000x;\S1#4;}"WINDOW HEIGHT 1st FLR LINE CEILING HEIGHT STONE VENEER PER SPECS6" CORNER BD. ON FRONT ELEV. &4" ON SIDES& REAR ELEV. TOP OF FOUNDATION \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" 612126 BRICK WAINSCOT, PER SPEC. SCALE:LEFT ELEVATION1/8" = 1'-0"- \A1;8'-4{\H0.750000x;\S3#8;}"\A1;HDR. HGT. @ 4010 661212 BRICK WAINSCOT, PER SPEC. SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;8'-0" \A1;20'-0"\A1;20'-0" \A1;1'-0"\PTYP. \A1;1'-0"\PTYP.\A1;1'-0"\PTYP. SCALE:ROOF PLAN1/8" = 1'-0"- ROOF AREA"A"3287 SQ. FT. 10:1210:12 10:1210:12 6:12 6:126:12 10:12 3:12 3:12 ELEVATION CT2H ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3287 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.38 5.48 5.08 49.73 12 0 AT EAVE 6.57 5.48 5.14 50.27 0 74.00 TOTAL (MIN)10.96 10.96 10.22 100.00 3 HIGH - RIDGE VENT 4.38 5.48 6.00 53.87 0 0 48.00 AT EAVE 6.57 5.48 5.14 46.13 0 74.00 TOTAL (MIN)10.96 10.96 11.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE \A1;1'-1" 1012 1012 3:12 SHINGLES PERSUB. SPECS. 9" CROSSHEAD14" PANELED SHUTTERS (TYP.) SHINGLES PERSUB. SPECS. STONE VENEERPER SPECS9" CROSSHEAD 4" TRIM SURROUND ON DOORSTONE VENEER PER SPECS 10" SQ. COLUMN(SEE PORCH DETAIL) 9" CROSSHEAD VERTICAL SIDING PER SPECS VERTICAL SIDING4" TRIM BOARD4" SILL STONE SILL6" TRIM BOARD (TYP.)DRIP CAP 9" CROSSHEAD OVER DOOR C L 1012 3:12 20202020 GABLE VENT PER SPEC SHINGLES PER SUB SPECS. PER SPECS SHINGLES PER SUB SPECS.FIXEDFIXED \A1;25'-2{\H0.750000x;\S1#2;}"\A1;6'-0" \A1;4'-6" A.F.F. \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT TOP OF FOUNDATION \A1;2'-11{\H0.750000x;\S5#8;}" \A1;2'-11{\H0.750000x;\S5#8;}" \A1;4'-0" FYPON LV12x36 OR EQUIV., TYP. SCALE:FRONT ELEVATION1/4" = 1'-0"- HORIZONTAL SIDING,\PPER SPEC 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 SUZETTE SCHUETTE06/07/2013 GARAGE RIGHT Croix 1993.301 LOT 06 06/07/2019 PLOTTED: June 12, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-CT2H.DWG A3 CT2H-2FS.1Cottage 2H - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule07/01/19 Mike Sheeks