HomeMy WebLinkAboutA000.3\A1;5'-4"
\A1;2'-7"
\A1;8{\H0.750000x;\S1#4;}"\A1;4"\A1;4"
DORMER DETAIL
9" CROSSHEADTRIM BOARD AROUND WINDOW
SCALE 1/4" = 1'-0"PORCH ELEVATIONS
LEFT PORCH FRONT PORCH RIGHT PORCH2" CORNER BOARD (TYP)SIDING PER COMM. SPECS (TYP)
BRICK WAINSCOT, PER SPEC.T.O. FOUNDATIONT.O. FLOOR \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
8" SQUARE COLUMN, PER SPEC
10" TRIM, PER SPEC
ROOF SHINGLES, PER SPEC
SCALE:REAR ELEVATION1/8" = 1'-0"-
HORIZONTAL SIDING, PER SPEC \A1;1'-1"\A1;1'-1"\A1;2'-4{\H0.750000x;\S1#4;}"WINDOW HEIGHT
1st FLR LINE
CEILING HEIGHT
STONE VENEER
PER SPECS6" CORNER BD.
ON FRONT ELEV. &4" ON SIDES& REAR ELEV.
TOP OF FOUNDATION \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
612126
BRICK WAINSCOT, PER SPEC.
SCALE:LEFT ELEVATION1/8" = 1'-0"-
\A1;8'-4{\H0.750000x;\S3#8;}"\A1;HDR. HGT. @ 4010
661212
BRICK WAINSCOT, PER SPEC.
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
\A1;8'-0"
\A1;20'-0"\A1;20'-0"
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
SCALE:ROOF PLAN1/8" = 1'-0"-
ROOF AREA"A"3287 SQ. FT.
10:1210:12
10:1210:12
6:12
6:126:12
10:12
3:12
3:12
ELEVATION CT2H
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3287 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.38 5.48 5.08 49.73 12 0
AT EAVE 6.57 5.48 5.14 50.27 0 74.00
TOTAL (MIN)10.96 10.96 10.22 100.00
3
HIGH -
RIDGE VENT 4.38 5.48 6.00 53.87 0 0 48.00
AT EAVE 6.57 5.48 5.14 46.13 0 74.00
TOTAL (MIN)10.96 10.96 11.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
\A1;1'-1"
1012
1012
3:12
SHINGLES PERSUB. SPECS.
9" CROSSHEAD14" PANELED SHUTTERS (TYP.)
SHINGLES PERSUB. SPECS.
STONE VENEERPER SPECS9" CROSSHEAD
4" TRIM SURROUND ON DOORSTONE VENEER PER SPECS 10" SQ. COLUMN(SEE PORCH DETAIL)
9" CROSSHEAD
VERTICAL SIDING PER SPECS
VERTICAL SIDING4" TRIM BOARD4" SILL
STONE SILL6" TRIM BOARD (TYP.)DRIP CAP
9" CROSSHEAD OVER DOOR
C L
1012 3:12
20202020
GABLE VENT PER SPEC
SHINGLES PER SUB SPECS.
PER SPECS
SHINGLES PER SUB SPECS.FIXEDFIXED
\A1;25'-2{\H0.750000x;\S1#2;}"\A1;6'-0"
\A1;4'-6" A.F.F.
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
WINDOW HEIGHT
1st FLR LINE
PLATE HEIGHT
TOP OF FOUNDATION
\A1;2'-11{\H0.750000x;\S5#8;}"
\A1;2'-11{\H0.750000x;\S5#8;}"
\A1;4'-0"
FYPON LV12x36 OR EQUIV., TYP.
SCALE:FRONT ELEVATION1/4" = 1'-0"-
HORIZONTAL SIDING,\PPER SPEC 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
SUZETTE SCHUETTE06/07/2013
GARAGE RIGHT
Croix
1993.301
LOT 06
06/07/2019
PLOTTED: June 12, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-CT2H.DWG
A3
CT2H-2FS.1Cottage 2H - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule07/01/19