HomeMy WebLinkAboutA100.0\A1;10"\A1;2'-5{\H0.750000x;\S1#4;}"
REF.
2/10
2/10
(4) 12" SH(4) 12" SH
2/10
2/10
2/10
2/102/0
2/4
1R/1S
1R/1S
1R/1S 1R/1S
1R/1S
1R/1S
12" DROP HDR.12" DROP HDR.12" DROP HDR.
12" DROP HDR.
12" DROP HDR.12" DROP HDR.12" DROP HDR.
(3) 3060 SH
16'-0"x7'-0" O.H.G.D.
2/8
3/0
2/10
2/8 FDWATER HEATER, PER SPEC 2/0
4010 FX
\A1;1'-10{\H0.750000x;\S1#2;}"
\A1;27'-5"\A1;5'-0"\A1;1'-0{\H0.750000x;\S1#2;}"\A1;5'-4"\A1;2'-4{\H0.750000x;\S1#2;}"\A1;15'-10"\A1;6'-0"\A1;57'-0"\A1;4'-0"\A1;67'-0" - OVERALL
\A1;2'-9{\H0.750000x;\S1#2;}"\A1;2'-6"\A1;14'-8{\H0.750000x;\S1#2;}"\A1;5'-3{\H0.750000x;\S1#2;}"\A1;5'-5{\H0.750000x;\S1#2;}"\A1;3'-6{\H0.750000x;\S1#2;}"\A1;67'-0" - OVERALL
\A1;7'-0"
\A1;6'-8"
\A1;8'-8{\H0.750000x;\S1#2;}"
\A1;11'-7{\H0.750000x;\S1#2;}"
\A1;10'-0"
\A1;10'-0"
\A1;20'-0"
\A1;20'-4"
\A1;13'-8"
\A1;54'-0" - OVERALL
\A1;6'-0"\A1;3'-0"\A1;3'-0"
\A1;2'-0"\A1;TYP.
\A1;4'-5"
\A1;5"\A1;3'-4"
\A1;2'-2{\H0.750000x;\S1#2;}"\A1;4'-0"\A1;2'-4{\H0.750000x;\S1#2;}"\A1;2'-5{\H0.750000x;\S1#2;}"\A1;3'-0{\H0.750000x;\S1#2;}"
\A1;10'-8"
\A1;6'-5"\A1;7'-4{\H0.750000x;\S1#2;}"
\A1;3'-3{\H0.750000x;\S1#2;}"
\A1;7'-9"
\A1;3'-8"\A1;10"
\A1;1'-9"
\A1;10'-0"
\A1;6'-1"
\A1;10'-8"
\A1;4'-9{\H0.750000x;\S1#2;}"\A1;1'-11{\H0.750000x;\S1#2;}"\A1;1'-8"\A1;1'-7{\H0.750000x;\S1#2;}"
\A1;1'-7{\H0.750000x;\S1#4;}"\A1;5'-4{\H0.750000x;\S1#2;}"
\A1;1'-5"\A1;2'-4{\H0.750000x;\S1#2;}"\A1;7{\H0.750000x;\S1#2;}"
\A1;3'-6{\H0.750000x;\S1#2;}"
\A1;2'-7"
\A1;2'-7"
\A1;5'-0"
\A1;4'-3{\H0.750000x;\S1#2;}"
\A1;4'-4{\H0.750000x;\S1#2;}"\A1;2'-4"
\A1;1'-4{\H0.750000x;\S1#2;}"
\A1;2'-5{\H0.750000x;\S3#4;}"
\A1;2'-3{\H0.750000x;\S3#4;}"
\A1;6'-11{\H0.750000x;\S1#2;}"\A1;8'-0"\A1;1'-1{\H0.750000x;\S1#2;}"
\A1;1'-7{\H0.750000x;\S1#2;}"
\A1;2'-0"\A1;1'-4"
\A1;3'-0"\A1;5'-0"\A1;3'-0{\H0.750000x;\S1#2;}"
\A1;9'-5{\H0.750000x;\S1#2;}"
\A1;7'-4{\H0.750000x;\S1#2;}"\A1;6{\H0.750000x;\S1#2;}"\A1;6'-0"
\A1;15'-0"
\A1;2'-8{\H0.750000x;\S1#4;}"
\A1;8'-5{\H0.750000x;\S1#2;}"
\A1;3'-6{\H0.750000x;\S3#4;}"
\A1;3'-0{\H0.750000x;\S1#2;}"\A1;1'-3{\H0.750000x;\S1#2;}"
3/0\P(SEE SPECS.)
(2) 3060 SH
\A1;7'-2"\A1;20'-3"
(2) 3060 SH (TEMP)
(3) 3060 SH
2/10
(2) 3060 SH
\A1;14'-0"\A1;10'-0"\A1;4'-0"
\A1;1'-10"
\A1;2'-4{\H0.750000x;\S1#2;}"
5/0 BI-PASS\A1;3'-6"
\A1;1'-4"\A1;1'-11{\H0.750000x;\S1#2;}"
2/10
2X6 WALL
\A1;21'-7{\H0.750000x;\S1#2;}"
2/10
\A1;3'-10{\H0.750000x;\S1#2;}"
3/0
\A1;34 {\H0.7x;\S1#2;}" HALF WALL \A1;6'-11{\H0.750000x;\S1#2;}"\A1;8'-0"
\A1;9'-3"
\A1;1'-1"
\A1;1'-1{\H0.750000x;\S1#2;}"\A1;1'-1{\H0.750000x;\S1#2;}"
\A1;1'-9"
FIREPLACE, PER SPEC.\A1;1'-6"\A1;4'-0"\A1;5'-10"
DROP SOFFIT FOR FIREPLACE VENTING
FURNACE PER MECHANICAL PLANS
\A1;4{\H0.750000x;\S1#2;}"
\A1;4{\H0.750000x;\S1#2;}"\A1;3'-1{\H0.750000x;\S1#2;}"\A1;6'-8{\H0.750000x;\S1#2;}"\A1;1'-2{\H0.750000x;\S1#2;}"
8" SQUARE COLUMN, PER SPEC
\A1;4"
\A1;20'-0"
\A1;5'-8"\A1;4"
3060
3060 SH
BRICK WRAP PER SPEC.
BRICK WRAP PER SPEC.
3068 ENT. DOOR
10" SQ. HALF COLUMN (SEE PORCH DETAIL)
10" SQ. HALF COLUMN (SEE PORCH DETAIL)
10" SQ. COLUMN
3060
\A1;2'-6"
\A1;16'-0"
\A1;2'-6"
\A1;5'-9{\H0.750000x;\S1#2;}"
\A1;6'-2{\H0.750000x;\S1#2;}"
\A1;3'-6"
\A1;3'-6"
\A1;3'-10{\H0.750000x;\S1#2;}"
\A1;3'-10{\H0.750000x;\S1#2;}"
\A1;21'-0"
\A1;12'-0"
\A1;7'-0"
\A1;14'-0"
\A1;54'-0" - OVERALL
\A1;16'-0"
\A1;4'-0"
\A1;4'-2"\A1;10"\A1;4"
\A1;10'-9"
\A1;10"
\A1;6'-7"
\A1;5"
\A1;5'-0"
\A1;10"\A1;1'-2"
\A1;2'-0"
\A1;6'-3"
\A1;3'-10{\H0.750000x;\S1#2;}"\A1;15'-0{\H0.750000x;\S1#2;}"
\A1;2'-8"
\A1;1'-7{\H0.750000x;\S1#2;}"
\A1;5"
1R/1S
\A1;9'-8{\H0.750000x;\S1#2;}"\A1;21'-4"
\A1;4{\H0.750000x;\S1#2;}"3060 SH
SCALE:FIRST FLOOR PLAN - 4" EXTERIOR WALLS1/4" = 1'-0"
2 CAR GARAGE
WIC9'-0" CLG.
OWNER'S SUITE9'-0" CLG. 8" TRAY (IN TRUSS)
9'-0"9'-8"OWNER'S BATH9'-0" CLG.
GATHERING ROOM9'-0" CLG.
KITCHEN9'-0" CLG.
PANTRY9'-0" CLG.
CAFE9'-0" CLG.
FLEX9'-0" CLG.
BEDROOM 29'-0" CLG.
BATH 29'-0" CLG.
3A2 S.2 3A2 S.2
COVERED PATIO
30X60 TUB/SHOWER
36x60 SHOWER
TR TR
TB TP
TP
TR
TB
FOYER9'-0" CLG.
HVAC9'-0" CLG.1A2 S.1
2A2 S.1
2A2 S.1
22"x30" ATTIC ACCESS
GREY BOX\pxqc;WASHER/DRYER
BEDROOM 39'-0" CLG.
30X60 TUB/SHOWER
TP
TR
BATH 39'-0" CLG.
LAUNDRY9'-0" CLG.
22"x30" ATTIC ACCESS
RAISED DW
COOKTOP-36
SINK
WALL OVEN
PORCH
1A2 S.1
\A1;{\LGENERAL SPECIFICATIONS\P\P\pxi-2,l2,t2;}1. ALL ANGLED WALLS (OTHER THAN THOSE AT 90%%D) SHALL BE CONSIDERED TO BE AT 45%%D UNLESS NOTED OTHERWISE\P2. ALL STUDS AT EXTERIOR AND INTERIOR WALLS SHALL BE 2x4 UNLESS OTHERWISE NOTED\P3. ALL STUDS AT EXTERIOR WALLS AND INTERIOR BEARING WALLS TO BE FRAMED AT 16" O.C. UNLESS NOTED OTHERWISE\P4. ALL NON-BEARING WALLS, OTHER THAN IN THE KITCHEN AND PLANNING CENTERS, TO BE 2x4 STUDS AT 24" O.C. UNLESS OTHERWISE NOTED OR RESTRICTED BY LOCAL CODES OR ORDINANCES. KITCHEN AND PLANNING CENTER WALLS WHERE WALL CABINETS ARE TO BE HUNG SHALL BE FRAMED AT 16" O.C.\P5. PROVIDE DOUBLE 2x TOP PLATES AT ALL LOAD BEARING WALLS.\P6. PROVIDE SINGLE TOP PLATE AT ALL INTERIOR NON-LOADING BEARING WALLS.\P7. PROVIDE A 1-3/8" OR LARGER SOLID CORE WOOD DOOR, SOLID CORE STEEL DOOR OR HONEYCOMB CORE STEEL DOOR, OR 20 MINUTE FIRE-RATED DOOR EQUIPPED WITH A SELF-CLOSING DEVICE BETWEEN GARAGE AND LIVING SPACE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE. \P8. PROVIDE FIRE SEPARATION BETWEEN DWELLING AND GARAGE IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P9. PROVIDE {\H0.7x;\S1#2;}" DRYWALL AT WALLS, CEILING AND UNDERSIDE OR STAIR ASSEMBLY ACCESSIBLE SPACE UNDER STAIRS IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P10. ALL GLAZING INSTALLED IN HAZARDOUS LOCATIONS AS DEFINED BY THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE SHALL HAVE A PERMANENT DESIGNATION OR LABEL AFFIXED TO EACH PANE OF GLAZING BEARING THE MANUFACTURER'S LABEL SHOWING THE TYPE AND THICKNESS OF GLASS. FOR OTHER THAN TEMPERED GLASS, LABELS MAY BE OMITTED PROVIDED THE BUILDING OFFICIAL APPROVES THE USE OF A CERTIFICATE, AFFIDAVIT OR OTHER EVIDENCE CONFIRMING COMPLIANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P11. ALL BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT NOT LESS THAN 72" ABOVE THE FLOOR PER THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODE.\P12. PROVIDE THERMO-PLY SHEATHING AND BATT INSULATION FILLING ALL CAVITIES AT EXTERIOR WALLS SURROUNDING TUBS AND SHOWERS.\P13. ALL REQUIRED GUARDRAILS AND GUARDWALLS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. GUARDS SHALL NOT BE LESS THAN 36" HIGH MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE AND NOT LESS THAN 34" HIGH MEASURED VERTICALLY FROM THE SLOPED PLANE THAT ADJOINS THE TREAD NOSINGS.\P14. ALL REQUIRED HANDRAILS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH 4 OR MORE RISERS. HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34" OR MORE THAN 38" AS MEASURED VERTICALLY FROM THE SLOPED PLANE THAT ADJOINS THE TREAD NOSINGS AND SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL.\P15. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM MUST HAVE AT LEAST ONE EMERGENCY ESCAPE OR RESCUE OPENING IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES. WHERE THE BASEMENT CONTAINS 1 OR MORE SLEEPING ROOMS, EMERGENCY ESCAPE OR RESCUE OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM. THE EMERGENCY ESCAPE OR RESCUE OPENING SHALL HAVE A CLEAR 5.7 SQUARE FEET OF OPEN AREA WITH A SILL HEIGHT OF NO MORE THAN 44" ABOVE THE FLOOR OR 5.0 SQUARE FEET OF OPEN AREA FOR GRADE-FLOOR WINDOWS. THE CLEAR OPENING SHALL A MINIMUM OF 24" OF OPENING HEIGHT AND 20" OPENING WIDTH. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE ADJACENT GROUND LEVEL ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL AND LADDER IN ACCORDANCE WITH THE CURRENTLY ADOPTED EDITION OF THE IRC OR APPLICABLE LOCAL CODES.\P16. FOR ADDITIONAL INFORMATION SEE STRUCTURAL DRAWINGS AND NOTESFLOORPLAN NOTES
1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
SUZETTE SCHUETTE06/07/2013
GARAGE RIGHT
Croix
1993.301
LOT 06
06/07/2019
PLOTTED: June 12, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-PLAN.DWG
A1
4-1.1First Floor Plan.4" Exterior Walls07/01/19
Mike Sheeks