Loading...
HomeMy WebLinkAboutGN - Emerick TSI Certificate311 E CITY CENTER DR CAR M E L, IN 46032 Builder: OLD TOWN DESIGN GROUP �,ITSM Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-13 Framed Floor N/A Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.3, SHGC: 0.27 Building Features Duct Supply R-20.0, Return R-20.0 Duct Leakage to Outside 185.0 CFM @ 25Pa Total Duct Leakage 336.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Natural Gas • 0.64 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 6120119 at 11:34 AM Ekotrope RATER - Version 3.1.1.2199 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report.