Loading...
HomeMy WebLinkAboutOBF-086 ENERGYIECC 2009 Performance Compliance Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY (EE) Community: OVERBROOK FARMS OBF086 (AS DESIGNED) OVERBROOK FARMS 86 Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,446 $202 $394 $2,042 $1,141 $0 $3,183 Requirements C-M, Energy Solutions As Designed S1,230 S188 S394 $1,813 S1,141 S0 $2,953 C4405.3 Performance -based compliance passes by 11.2% R402.4.12 Air Leakage Testing Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 1 1.2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 6110119 at 3:06 PM Ekotrope RATER - Version 3.1.0.2191 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 14562 OVERBROOK DR CARMEL, IN 46074 Builder: FISCHER HOMES �JITMRP4W_►'1 Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-10 Framed Floor R-30 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 210.0 CFM @ 25Pa Total Duct Leakage 304.0 CFM @ 25Pa Heating Furnace • Natural Gas • 96.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 6/10119 at 3:06 PM Ekotrope RATER - Version 3.1.0.2191 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 14562 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Model: CLAY (EE) Community: OVERBROOK FARMS Builder FISCHER HOMES OBF086 (AS DESIGNED) OVERBROOK FARMS 86 General Building Information Conditioned Area (sq ft) 4,231 Conditioned Volume (cubic ft) 35,149 Insulated Shell Area (sq ft) 7,985 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (1,147 s.f.) R-0 perimeter insulation, R-0 under slab insulation. [ Name: LL SLAB (414 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (282 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 104, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: COND LLIAMB (Exterior Perimeter [ft]: 18, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 1.5) R: 10.012 Fully insulated (top to bottom) El Name: CONDIGAR (Exterior Perimeter [ft]: 41, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Energy Code Inspection Checklist Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY (EE) Community: OVERBROOK FARMS OBF086 (AS DESIGNED) OVERBROOK FARMS 86 Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Inspection Status Results are projected C", Energy Solutions E[ Name: COND LLIGAR (Exterior Perimeter [ft]: 14, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 1.5) R: 10.012 Fully insulated (top to bottom) Above Grade Wall El Name: CONDIAMB (1,770 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I [ Name: CONDIAMB 2X6 (315 s.f.) R-0.41 continuous insulation, R-19 cavity insulation Insulation Grade: I [ Name: CONDIGAR (399 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I [ Name: CONDIATTIC (264 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (235 s.f.) R: 15.414 El Name: CONDIGAR (14 s.f.) R: 15.414 [ Name: CONDIATTIC (62 s.f.) R: 15.414 Roof [ Name: SECOND (1,843 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I 2 Energy Code Inspection Checklist Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY (EE) Community: OVERBROOK FARMS OBF086 (AS DESIGNED) OVERBROOK FARMS 86 Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES inspection Status Results are projected El Name: FRONT (88 s.f.), U: 0.310, SHGC: 0.28, Orientation: EAST El Name: SACK (137 s.f.), U: 0.310, SHGC: 0.28, Orientation: WEST El Name: BACK 2X6 (105 s.f.), U: 0.310, SHGC: 0.28, Orientation: WEST El Name: RIGHT SIDE (17 s.f.), U: 0.310, SHGC: 0.28, Orientation: NORTH 11 Name: LEFT SIDE (52 s.f.), U: 0.310, SHGC: 0.28, Orientation: SOUTH 1-I Name: LEFT BSMT (20 s.f.), U: 0.310, SHGC: 0.28, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 96.1 AFUE j] Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER C-M, Energy Solutions 3 Energy Code Inspection Checklist Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY (EE) Community: OVERBROOK FARMS OBF086 (AS DESIGNED) OVERBROOK FARMS 86 Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Inspection Status Results are projected E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 2,929 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 210.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 304.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. 4 Project Notes Building Summary Property Organization Inspection Status Energy C-M Solutions 14562 OVERBROOK DR TSI Energy Solutions Results are projected CARMEL, IN 46074 Devin Sielschott Model: CLAY (EE) Community: OVERBROOK FARMS 86 Builder FISCHER HOMES OBF086 [AS DESIGNED] OVERBROOK FARMS 86 enera?Building Information mber Of Bedrooms 4 mber Of Floors 2 nditioned Floor Area [sq_ ft.] 4;231 conditioned, attached garage? Yes nditioned Volume [Cu. ft.] I 35;149 tal Units in Building 1 sidence Type Single family detached oor Number odel CLAY (EE) mmunity OVERBROOK FARMS 86 mate Zone 5A Foundation Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing COND LLIAMB R-15 Finished, G3 1 1.5 18 Exposed Exterior Conditioned Space COND LUGAR R-15 Finished, G3 1 1.5 14 Exposed Exterior Conditioned Space CONDIAMB R-10 Draped, 4ft 1 7 104 Exposed Exterior Conditioned Space COND/GAR R-10 Draped, Oft 1 7 41 Exposed Exterior Conditioned Space Foundation Wall Library List Name Feet From Wall Top To Feet From WaIf Top To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulation value Top Bottom R-10 Draped, Oft 0 4 No NIA NIA 10.00 R-15 Finished, G3 NIA NIA Yes NIA NIA 10.012 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated FLLLL 177 Below Grade 0 0 1.147.0 sq. ft. Exposed Exterior Conditioned Space SLAB Uninsulated 58 On Grade 0 0 414.0 sq. ft. Exposed Exterior Conditioned Space 1 Building Summary Property Organization Inspection Status Energy Solutions C-M 14562 OVERBROOK DR TSI Energy Solutions Results are projected CARMEL, IN 46074 Devin Sielschott Model: CLAY [EE] Community: OVERBROOK FARMS 86 Builder FISCHER HOMES OBF086 [AS DESIGNED] OVERBROOK FARMS 86 Fslab Library List MEMMUM Name Wall Construction Slab Completely Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width Iffy Insulation Depth [ft] Insulation R Value Uninsulated Woad Frame / Other No ❑ ❑ ❑ No D.00 Framed Floor Name Library Type Carpet R Floor Grade Surface Area Location I OVER GARAGE R-30, GR1 123 Above Grade 282.0 sq. ft Unconditioned, attached garage Framed Floor Library List Name Effective R-value R-30, GR1 27.493 Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-19, OSB 235.0 sq. tt. Exposed Exterior CONDIATTIC G1 R-19, OSB 62.0 sq. ft. Attic CONDIGAR G1 R-19, OSB 14.0 sq. ft. Unconditioned, attached garage Rim Joist Library List Name Effective Insulation R-value G1 R-19, OS8 15.414 Building Summary Property Organization 14562 OVERBROOK DR TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Model: CLAY [EE] Community: OVERBROOK FARMS 86 Builder FISCHER HOMES OBF086 [AS DESIGNED] OVERBROOK FARMS 86 Wall Name Library Type Inspection Status Results are projected Surface Color Surface Area Energy Solutions C-M Location CONDIAMB G1 R-15 BATT, T-PLY Medium 1.770.0 sq. fl. Exposed Exterior CONDIAMB 2X6 G1 R-19 BATT, T-PLY Medium 315.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-15 BATT, T-PLY Medium 264.0 sq. ft. Attic CONDIGAR G1 R-15 Gar Walls Medium 399.0 sq. ft. Unconditioned, attached garage Wall Library List Name Effective R-value G1 R-15 BATT, T-PLY 12.842 G1 R-15 Gar Walls 11.972 G1 R-19 BATT, T-PLY 17278 Glazing 0 Name Library Type Wall Assignment Foundation Wall Assignment Overhang Depth Overhang Ft Top To Overhang Ft To Bottom Orientation M Surface Area BACK U-.31, SHGG28 CONDIAMB 0 0 0 West 137.0 sq. H. BACK 2X6 U-.31, SHGG28 CONDIAMB 2X6 0 0 0 West 105.0 sq. H. FRONT U-.31, SHGG.28 CONDIAMB 0 0 0 East 88.0 sq. 1 LEFT BSMT U-.31, SHGG28 CONDIAMB 0 0 ❑ South 20.0 sq. ft LEFT SIDE U-.31, SHGG28 CONDIAMB 0 0 ❑ South 52.0 sq. ft RIGHT SIDE U-.31, SHGG28 CONDIAMB 0 0 0 North 17.0 sq. 1 Building Summary Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY [EE] Community: OVERBROOK FARMS 86 OBF086 [AS DESIGNED] OVERBROOK FARMS 86 FGlazing Library List Name I1I-.31,SHGC-28 Skylight Organization TSI Energy Solutions Devin Sielschoft Builder FISCHER HOMES Inspection Status Results are projected 028 0.310 C-M, Energy Solutions wr None Present Skylight Library List None Present Opaque Door Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta n ce FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 sq_ ft Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior Opaque Door Library List Name Effective U #actor Steel Door 0.182 Roof Insulation Name Library Typ SECOND R-38 Blown. GR1 krea Clay or Concrete Roof �-C] Tiles 1,843 No n Medium 1,843.0 sq. R Attic 4 Building Summary Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY [EE] Community: OVERBROOK FARMS 86 OBF086 [AS DESIGNED] OVERBROOK FARMS 86 FRoof Insulation Library List kl- U- R-38 Blown, GR1 Whale House Infiltrati nfiitration 5 ACH at 50 Pa Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES No Blower -door tested Mechanical Ventilation None Present Inspection Status Results are projected 38268 4 C-M, Energy Solutions Lighting Interior Fluorescent % Interior LED Lighting % Exteriar Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting 0 0 Dnsite Generation None Present Dnsite Generation Library Li None Present Solar Generation None Present 0 0 0 0 Building Summary Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY (EE) Community: OVERBROOK FARMS 86 OBF086 (AS DESIGNED) OVERBROOK FARMS 86 Kolar Generation Library Conditioning Equipment Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Inspection Status Results are projected C-M, Energy Solutions Name Library Type Heating Percent Load Coaling Percent Load Hot Water Percent Load Air conditioner (2) GSX130601B 0% 100% 0% Fuel -fired air GMSS961005CN 100% 0% 0% distribution (1) Water Heating (3) ENT 50 100 0% 0% 100% Equipment Type: ENT 50 100 i Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.99 quipment Type: GMSS961005CN Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG [Single Speed] Heating Efficiency 96.1 AFUE Heating Capacity [kBtulh] 96 Use default EAE No EAE [kWh] 1;077 rEqu1pmenit Type: G5X130601B Fuel Type Electric Distribution Type Forced Air Motor Type PSG [Single Speed] Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 57 61 Building Summary Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY (EE) Community: OVERBROOK FARMS 86 OBF086 [AS DESIGNED] OVERBROOK FARMS 86 1bution System Lion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 4231 4 3❑ 3❑ 771.9 571.8 210 304 Post -Construction Yes Conditioned Space 8❑ 80 Attic (well vented; under insulation) 2❑ 2❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 14562 OVERBROOK DR CARMEL, IN 46074 Model: CLAY [EE] Community: OVERBROOK FARMS 86 OBF086 [AS DESIGNED] OVERBROOK FARMS 86 Water Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Builder FISCHER HOMES Standard No 85 No No 30 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year "M � C-M, Energy Solutions ,�