A019
SCALE: 3/4" = 1'-0" PLAN DTL - 3'-0"w. LANDING w/ STEPS TO GRADE @ HORIZONTAL SIDING 3'-0" 10" 10" 10"3'-0" 1'-0"4'-0"24" Ø FROST FOOTING 12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. JOIST HANGER 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD 2x6 P.T. DECK JOIST - @ 16" o.c. 5/4 x 6 P.T. DECKING 2x2 PICKETS @ 5" o.c. 4x4 P.T. POST - 36" BELOW GRADE 12" Ø CARRIAGE BOLTS - 16" o.c. STAGGERED 2x BAND BOARD - SIZE VARIES 2x12 P.T. TREADS & STRINGERS - MAX. 81 4" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE - SHOWN BELOW 01 6'-0" 10" 10" 10"3'-0" 1'-0"4'-0"SCALE: 3/4" = 1'-0" PLAN DTL - 6'-0"w. LANDING w/ STEPS TO GRADE @ HORIZONTAL SIDING JOIST HANGER 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD 2x6 P.T. DECK JOIST - @ 16" o.c. 5/4 x 6 P.T. DECKING 2x2 PICKETS @ 5" o.c. 4x4 P.T. POST - 36" BELOW GRADE 12" Ø CARRIAGE BOLTS - 16" o.c. STAGGERED 2x BAND BOARD - SIZE VARIES 24" Ø FROST FOOTING 12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. 2x12 P.T. TREADS & STRINGERS - MAX. 81 4" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE - SHOWN BELOW 02 SCALE: 3/4" = 1'-0" PLAN DTL - 3'-0"w. LANDING w/ STEPS TO GRADE @ BRICK VENEER 3'-0" 10" 10" 10"3'-0" 1'-0"4'-0"12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. JOIST HANGER 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD 2x6 P.T. DECK JOIST - @ 16" o.c. 5/4 x 6 P.T. DECKING 2x2 PICKETS @ 5" o.c. 4x4 P.T. POST - 36" BELOW GRADE 2x12 P.T. TREADS & STRINGERS - MAX. 814" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE - SHOWN BELOW 3" 2'-6" BRICK BRACKET - INSTALL PER MANUFACTURER'S INSTRUCTIONS 2x BAND BOARD - SIZE VARIES 3" 24" Ø FROST FOOTING 03 07 D5.0 06 D5.0 07 D5.0 06 D5.0 6'-0" 10" 10" 10"3'-0" 1'-0"4'-0"SCALE: 3/4" = 1'-0" PLAN DTL - 6'-0"w. LANDING w/ STEPS TO GRADE @ BRICK VENEER JOIST HANGER 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD 2x6 P.T. DECK JOIST - @ 16" o.c. 5/4 x 6 P.T. DECKING 2x2 PICKETS @ 5" o.c. 4x4 P.T. POST - 36" BELOW GRADE BRICK BRACKET - INSTALL PER MANUFACTURER'S INSTRUCTIONS 2x BAND BOARD - SIZE VARIES 12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. 2x12 P.T. TREADS & STRINGERS - MAX. 814" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE - SHOWN BELOW 7" 2'-5" 7"2'-5" 24" Ø FROST FOOTING 04 05 06 07 SCALE: 3/4" = 1'-0" ELEV. - LANDING w/ STEPS TO GRADE3'-0"12" Ø CARRIAGE BOLTS 2x2 PICKETS @ 5" o.c. 2x12 P.T. TREADS & STRINGERS - MAX. 81 4" RISE (MIDWEST) - MAX. 73 4" RISE (ATLANTA) - FIELD VERIFY NUMBER OF TREADS 214"2x6 P.T. TOP RAIL - HOLD PICKETS DOWN 214" FROM TOP 2x4 BLK'G. SET 1" BACK FROM NOSING - TO PREVENT PASSAGE OF 4" Ø SPHERE 12" HANDGRIP GROOVE - SEE DTL. 08/D5.0 3'-0"SCALE: 1" = 1'-0" BRICK VENEER CAST-IN-PLACE CONCRETE FOUNDATION WALL STRUCTURAL SHEATHING 1x TRIM BOARD 12" Ø CARRIAGE BOLTS - 16" o.c. STAGGERED GALV. DECK FLASHING JOIST HANGER 5/4 x 6 P.T. DECKING 2x6 P.T. DECK JOIST 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD - RIP TO FIT 2x BAND BOARD - SIZE VARIES 2"2" CAULK - SMOOTH OUT w/APPLICATOR SECTION DETAIL - LEDGER BOARD @ BRICK VENEER4"BRICK BRACKET - INSTALL PER MANUFACTURER'S INSTRUCTIONS SCALE:1" = 1'-0" HORIZONTAL SIDING CAST-IN-PLACE CONCRETE FOUNDATION WALL STRUCTURAL SHEATHING - EXTEND SHEATHING TO 12" BELOW T/FOUNDATION 1x TRIM BOARD 12" Ø CARRIAGE BOLTS - 16" o.c. STAGGERED GALV. DECK FLASHING JOIST HANGER 5/4 x 6 P.T. DECKING 2x6 P.T. DECK JOIST 2x6 P.T. LEDGER - HOLD T/ LEDGER 4" BELOW DOOR THRESHOLD - RIP TO FIT 2x BAND BOARD - SIZE VARIES 2"2" CAULK - SMOOTH OUT w/APPLICATOR POLY FLASHING SECTION DETAIL - LEDGER BOARD @ HORIZONTAL SIDING4"08 SCALE: 1 1/2" = 1'-0" SECTION - HANDRAIL 12" HANDGRIP GROOVE - BOTH SIDES 512"134"314" 214"2x2 P.T. PICKET @ 5" o.c. - HOLD DOWN 21 4" FROM T/ 2x6 TOP RAIL 2x6 P.T. TOP RAIL STAIRS TO GRADE TO BE INSTALLED 13 15 16 SCALE: SECTION - FOOTING @ DECK COLUMN 3/4" = 1'-0" 1'-6"REFER TO GENERAL NOTES FORMINIMUM FROST FOOTING DEPTH18"Ø C.I.P. CONCRETE FT'G - REFER TO GN FOR MIN. FROST FOOTING DEPTH APPROXIMATE LINE OF GRADE 'SIMPSON' STANDOFF POST BASE - # ABA66Z - ANCHOR TO FOOTING w/ 12"Ø EXPANSION BOLTS, EMBED MINIMUM 4" 12 1± 6x6 P.T. POST - FLUSH w/ TOP OF DECK JOISTS 512" NOTE: 22"Ø C.I.P. CONCRETE FT'G @ CENTER OF 17'-6"w. DECK - REFER TO GN FOR MIN. FROST FOOTING DEPTH 212" T/ LEDGER BD T/ SUBFLOOR 21116" 21116"2716"FOUNDATION WALL 2x P.T. LEDGER BOARD - REFER TO JOIST LAYOUT - SET T/ LEDGER 212" BELOW T/ SUBFLR, FLUSH w/ T/ BRICK BRACKET - BOLT TO RIM JOIST THROUGH BRICK BRACKET w/ 12"Ø CARRIAGE BOLTS w/ WASHERS @ 29" o.c., STAGGERED METAL JOIST HANGER DECKING - BY OTHERS DURING CONSTRUCTION CONTINUOUS FLASHING - EXTEND PAST JOIST HANGER 2x P.T. JOISTS @ 16" o.c. - REFER TO JOIST LAYOUT BRICK BRACKET - INSTALL PER MANUFACTURER'S INSTRUCTIONS SCALE: SECTION - LEDGER BOARD @ DECK 3/4" = 1'-0" SCALE: SECTION - COLUMN @ DECK & BEAM 3/4" = 1'-0" 6x6 P.T. POST - FLUSH w/ TOP OF DECK JOISTS (2) 2x12 P.T. BEAM - NOTCHED INTO 6x6 P.T. POSTS - w/ (2) 12"Ø CARRIAGE BOLTS w/ WASHERS PER 6x6 POST - ℄ OF CARRIAGE BOLTS @ MIN. 2 1 4" FROM EDGE OF 2x6 POST 2x P.T. BAND BOARD - INSTALL DECKING AROUND COLUMN AND ON BAND BOARD DECKING - BY OTHERS DURING CONSTRUCTION 512" 2x10 P.T. JOISTS @ 16" o.c. 2'-112" CANTILEVER NOTE: DECKING, RAILS, LANDINGS, AND STAIRS TO GRADE TO BE INSTALLED BY OTHERS DURING CONSTRUCTION 14 17 212"T/ LEDGER BD T/ SUBFLOORDECKING - BY OTHERS DURING CONSTRUCTION - EXTEND TO TUCK BENEATH DOOR THRESHOLD DECKING - VERTICAL BENEATH THRESHOLD TO T/ DECKING 2x P.T. BLOCKING - @ EACH END OF BRICK OPENING - ALONGSIDE DECK BRACKETS - @ 16" o.c., REMAINDER SCALE: SECTION - DECK @ DOOR THRESHOLD 3/4" = 1'-0" SCALE: SECTION - COLUMN @ DECK & BEAM 3/4" = 1'-0" 6x6 P.T. POST - FLUSH w/ TOP OF DECK JOISTS (2) 2x12 P.T. BEAM - NOTCHED INTO 6x6 P.T. POSTS - w/ (2) 12"Ø CARRIAGE BOLTS w/ WASHERS PER 6x6 POST - ℄ OF CARRIAGE BOLTS @ MIN. 2 1 4" FROM EDGE OF 2x6 POST 2x P.T. BAND BOARD - INSTALL DECKING AROUND COLUMN AND ON BAND BOARD 2x P.T. JOISTS @ 16" o.c. - REFER TO JOIST LAYOUT DECKING - BY OTHERS DURING CONSTRUCTION 512" Xref K:\AC OVERBROOK FARMS REASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:6/10/2019 2:52 PM# OBF010860000 OBF010860000 * MARKET HOME *14562 OVERBROOK DRIVECLAY46-430-CLAY ENGLISH ELEGANCE WITH BRICKCARMEL, IN86 05/2017 JP---- --------------------------------------------fieldspecchange@fischerhomes.comREVISED BY:---- ---- ----ARCH. SPECIALIST:SAPPHIRE TRADE SUPPORT sapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC----D5.0 06/28/19 Mike Sheeks