Loading...
HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property Organization 7032 PICKETT PL TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: BERKLEY Michael Hill Community: THE GROVE AT LEGA[ Builder GL100 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 100 Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,139 5173 5342 $1,655 S800 SO $2,455 Requirements C-M, Energy Solutions As Designed 51,110 S165 S342 $1,617 S800 S0 $2,417 C4405.3 Performance -based compliance passes by 2.3% R402.4.12 Air Leakage Testing Air sealing is S.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 2.3%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 616119at1:39PM Ekotrope RATER - Version 3.1.0.2189 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 7032 PICKETT PL CAR M E L, IN 46033 Builder: PYATT BUILDERS, LLC Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor R-38 Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U-Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 120.0 CFM @ 25Pa Total Duct Leakage 192.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 616119 at 1:39 PM Ekotrope RATER - Version 3.1.0.2189 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 7032 PICKETT PL TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: BERKLEY Michael Hill Community: THE GROVE AT LEGA[ GL100 (AS DESIGNED) THE GROVE AT LEGACY 100 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Builder PYATT BUILDERS, LLC 2,449 23,174 6,208 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (1,133 s.f.) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor El Name: OVER GAR (271 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (2,672 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIGAR (350 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIATTIC (213 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Energy Code Inspection Checklist Property 7032 PICKETT PL CARMEL, IN 46033 Model: BERKLEY Community: THE GROVE AT LEGA[ GL100 (AS DESIGNED) THE GROVE AT LEGACY 100 Roof Name: CONDIAMB (94 s.f.) R: 11.691 Name: CONDIATTIC (71 s.f.) R: 11.691 Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Name: MAIN (1,404 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f. ) U: 0.182 Glazing Inspection Status Results are projected 11 Name: FRONT (103 s.f.), U: 0.320, SHGC: 0.31, Orientation: EAST 11 Name: BACK (84 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST Name: SLIDER (40 s.f.), U: 0.320, SHGC: 0.31, Orientation: WEST E] Name: LEFT SIDE (75 s.f.), U: 0.320, SHGC: 0.31, Orientation: SOUTH E] Name: RIGHT SIDE (148 s.f.), U: 0.320, SHGC: 0.31, Orientation: NORTH Skylight None Present Mechanical Ventilation None Present C-M, Energy Solutions 2 Energy Code Inspection Checklist Property Organization 7032 PICKETT PL TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: BERKLEY Michael Hill Community: THE GROVE AT LEGA[ Builder GL100 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 100 Mechanical Equipment inspection Status Results are projected 0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE M Air conditioner • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,931 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 120.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 192.0 CFM @ 25Pa C", Energy Solutions 3 Energy Code Inspection Checklist Property Organization 7032 PICKETT PL TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: BERKLEY Michael Hill Community: THE GROVE AT LEGA[ Builder GL100 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 100 Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 7032 PICKETT PL CARMEL, IN 46033 Model: BERKLEY Community: THE GROVE AT LEGACY 100 GL100 (AS DESIGNED) THE GROVE AT LEGACY 100 eneraFBuilding Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq_ ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Foundation Wall Library List Slab C-M Energy Solutions Organization Inspection Status TSI Energy Solutions Results are projected 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC 3 2 2;449 Yes 23;174 1 Single family detached BERKLEY THE GROVE AT LEGACY 100 5A None Present None Present Masonry Area n SLAB R-10, 1'down, 2' in 175 On Grade 1.23 0 1,133.0 sq. f[. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, 2' in Wood Frame /Other No 2 1 10 No 10.00 1 Building Summary Property Organization 7032 PICKETT PL TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: BERKLEY Michael Hill Community: THE GROVE AT LEGACY 100 Builder GL100 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 100 OVER GAR R-38, GR1 Framed Floor Library List Name R-38, GRi Rim Joist Name CONDIAMB CONDIATTIC Rim Joist Library List Name G1 R-15, OSB 33.825 C-M Energy Solutions Inspection Status Results are projected e Surface Area Location 1.23 Above Grade 271.0 sq. ft Unconditioned, attached garage G1 R-15, OSB 94.0 sq. ft. Exposed Exterior G1 R-15, OSB 71.0 sq. tt. Attic Name Library Type Surface Color Surface Area Location CONDIAMB G1 R-15 BATT, OSB Medium 2.672.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 213.0 sq. ft. Attic CONDIGAR G1 R-15 Gar Walls Medium 350.0 sq. ft. Unconditioned, attached garage 2 Building Summary Property Organization Inspection Status Energy C-M Solutions 7032 PICKETT PL TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: BERKLEY Michael Hill Community: THE GROVE AT LEGACY 100 Builder GL100 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 1 D0 RVall-library List Name Effective R-value G1 R-15 BATT, OSB 13.423 G1 R-15 Gar Walls 11.972 Glazing Name Library Type Wall Assignment Foundation Wall Overhang Assignment Depth Overhang Ft Top To Overhang Ft To Bottom Orientation Surface Area BACK U-.32, SHGG.31 CONDIAMB 0 0 0 West 84.0 sq. ft. FRONT U-.32, SHGG.31 CONDIAMB 0 0 0 East 103.0 sq. ft. LEFT SIDE 11-.32, SHGG.31 CONDIAMB 0 0 ❑ South 75.0 sq. ft. RIGHT SIDE 11-.32, SHGG.31 CONDIAMB 0 0 ❑ North 148.0 sq. ft. SLIDER 11-32, SHGG.31 CONDIAMB 0 0 ❑ West 40.0 sq. ft Glazing Library List Name Shg c U factor U-.32, SHGC-.31 0.31 0.320 Skylight None Present Skylight Library List None Present Building Summary Property Organization 7032 PICKETT PL TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: BERKLEY Michael Hill Community: THE GROVE AT LEGACY 100 Builder GL100 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 100 Fopaque Door Name Library Type Wall Assignmen FRONT Steel Door CONDIAMB GARAGE Steel Door CONDIGAR ndatPon Wall Assignment Opaque Door Library List Name Effective U-factor 0.182 Inspection Status Results are projected Solar Absorptance C-M, Energy Solutions PF M r Surface Area Location 0.9 0.75 Medium 20.0 sq- ft Exposed Exterior 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location P.f.] Tiles F•,9AIN R-38 Blown, GR1 1,404 No Medium 1,404-0 sq. ft Attic Roof Insulation Library List Name Has Radiant Barrier Effective R-value ?•8 3 :a l No 38268 Whole House Infiltratic Infiltration I5 ACH at 50 Pa Mechanical Ventilation Blower -door tested 4 M Building Summary Property Organization 7032 PICKETT PL TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: BERKLEY Michael Hill Community: THE GROVE AT LEGACY 100 Builder GL100 (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 100 ighting % Interior Fluorescent °% Interior LED Lighting % Exterior Fluorescent Lighting Lighting 0 0 C-M Energy Solutions Inspection Status Results are projected Fluorescent Lighting 0 C Gnsite Generation mmmft� m None Present Gnsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Literary Type Air co nd itione r CA13NA030 Fuel4red air 9125A42060S17 distribution Water Heating RE350" Heating Percent Load Cooling Percent Load Hot Water Percent Load 0% 100% 100% ❑ % 0% 0% 0% ❑% 100% Building Summary Property 7032 PICKETT PL CARMEL, IN 46033 Model: BERKLEY Community: THE GROVE AT LEGACY 100 GL100 (AS DESIGNED) THE GROVE AT LEGACY 100 quipment Type: Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtulh] Use default EAE EAE [kWh] Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC 912 SA42060 S 17 gquipment Type: CA13NA030 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Natural Gas Forced Air PSG (Single Speed) 92.1 AFUE 57 Yes 736.1 i Electric Forced Air PSG (Single Speed) 13 SEER 27.4 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 7032 PICKETT PL CARMEL, IN 46033 Model: BERKLEY Community: THE GROVE AT LEGACY 100 GL100 (AS DESIGNED) THE GROVE AT LEGACY 1 D0 1butivn System Lion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Forced Air Fuel -fired air distribution Air conditioner 2449 2 3❑ 2❑ 661.23 244.9 120 192 Post -Construction Yes Attic (well vented; under insulation) 4❑ 40 Conditioned Space 6❑ 6❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 7032 PICKETT PL CARMEL, IN 46033 Model: BERKLEY Community: THE GROVE AT LEGACY 100 GL100 (AS DESIGNED) THE GROVE AT LEGACY 100 ater Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Standard No 75 No No 20 No Electric Timer Controls ff"W 704 kWh/Year 0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year "M � Inspection Status Results are projected C-M, Energy Solutions ,�