HomeMy WebLinkAboutE3-2 - Second Floor Power Plan -Area B2 T WORKSPACE CORRIDOR 0 I D IF Imo, DECONTAMINATION HP4, F50 2236 175 ❑ O ❑ I rcY 7t L WAVE Phase 2 - Enlarged Decontamination 236 & Central Sterile 233 Power Plan \--J 114,E =1,-0,� 4.3 45. 4.7 5.1 — — —I — — — — WAITING 202 I I I I I STAIR O REG1 REG2 CORRIDOR 201 ..�,. n 240 ,.,.,., CORRIDOR 63 STAFF LOUNGE 2d2 ���iii III III ME LOCKER ROC � 2d4 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel �VI(AW \tPrv:4VM/�L DATE: Vf/V`J/-IU I 11 MECH CHASISj N 204 CORRIDOR 205 239 =&RIOR z3e 6 7 8 9 9.3 4 OINSULT WATER SOFTENS — — — — —— — 262 (D R-TVACMP--� STORAGE FAN ROOM 26d — — — — RECEIPT 15 20,T2, p OFFICE W HP4 J 7 w 219 O CORRIDOR LRP6C -7 TRANSFOR R SFORMER CONSULT M3 213A LASER R OM L HP3 LS WILLS CR MLCRA 211 231 HP2 9 EL TOR 1 CORRIDOR WORK SPAC 210 In HAZARD CORRIDOR 218 ■ SOONTAMINATIO� pap CONSU OFFICE O OFFI O SEE DETAIL CENTRAL STERILE 221A ON SHEET E3-2C ❑ 233 SEE DETAIL 4 ON SHEET Eb2C CORRIDOR !1 pREIPOST OP R00 REIPOST OP ROOK PREIPOST OP RO M 222 223 224 Q M 234 CORRIDOR I WAVE71 23] CORRIDOR �\ CORRIDOR 228 JAN EpUIPMENTSTORAGE 216 220 PREIPOST OR ROO PREIPOST OR ROO U U=a SOILED ICI YI 2 4 �� MEDS R00 BIOHAZARD 1 253 1 0 REIPOST P ROOM PREMOST OR ROOM TOILET ESH-284 SH-282 25 260 _ ORK STATION 27] OR#2 TYPE — — —OR#1 TYPE _ .. �1P4TF90 'F90 — — — — O 268 4 245 Eal a a El16 RP3q'.a �- ¢'cd CORRIDOR ryP src a � STO GE PREMOST OR 279 ADA TOILET 3 �7 2]6 M� 261 ww� 10 _ m° PATIENT RC OM ou 7MENURSE STATION HORRID C 75 8 PM€N — ORRIDOR +I — — — — 9 286 66 26V 11 280 O ORKAREA TOILET SUB STERILE 246 CORRIDOR m 4 MLC .41 18 - 270 267 ILE SCRUB AREA 250 10 EMLC 3:41 p3B: 331 ELI 281 WORK S ATION ED SEE DETAIL 22 TOILET 5 75 75 . n E3e� -3 �] RECOVERY 2]f 290 Q LINEN J EM CRA 3 EM RA 3 EMLCRA II P3 :41 2 2 /-EMLCRA:7 12 EMLC $ N 1 RP3B: 29 13 rc . 10 17 10 17 PATIENT RECOVERY OR A3 TYPE OR d4 TYPE RP3B'. 31� J s 274 MLCRA:S �l w w 12 240 2a9 `I II RP3B: " 0' EMLCRA. 70 = RECOVERY RP3B 29 RP3B'. 39 m J EMI•CRA: 13 � 209 q ®Ea l®� ® ® ®¢ ®15 RP3B:41 3.� Phase 2 - Second Floor Power Plan - Area B 9.8 -�� A.3 www I B.2 STAIR B.6 —41 B.9 NURSE MANAGE )RRIDO 267 266 OFFICE 263 PLAN NOTES 1 CONNECT NEW NORMAL POWER RECEPTACLETOEXISPNG120V,20A, IF NORMAL CIRCUIT THAT WAS MAINTAINED DURING DEMOLITION. EXTEND I MODIFY EXISTING WIRINGI CONDUIT AS REQUIRED. 2 RECEPTACLES FOR OR VIDEO INTEGRATION DATA RACK. COORDINATE LOCATION AND MOUNTING HEIGHT WITH OWNERS VENDOR. 3 CONNECT COMPLETE NEW ELECTRIC STEAM HUMIDIFIER VIA CIRCUIT INDICATED. PROVIDE 3P-60A, 460V, FUSIBLE DISCONNECT. FUSE PER MANUFACTURERS RECOMMENDATIONS. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. COORDINATE EXACT LOCATION PRIOR TO INSTALLATION. 4 RECEPTACLE FOR WALL MOUNTED PATIENT TRACKING TELEVISION. COORDINATE LOCATION AND MOUNTING HEIGHT WITH ARCHITECT. 5 CONNECT COMPLETE NEW STERILIZERMACIRCUIT INDICATED. PROMDE3P-6K HEIN. FUSIBLE DISCONNECT. FUSE PER MANUFACTURERS RECOMMENDATIONS. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. COORDINATE EXACT LOCATION PRIOR TO INSTALLATION. 6 CONNECT AUTO OPERATORS COMPLETE TO 121V,21A, 1 P LIFE SAFETY CIRCUIT FROM PANEL'EMLS'LOCATED IN SECOND FLOOR ELECTRICAL ROOM 221. PROVIDE PUSH PLATES AND ALL ASSOCIATED ROUGH -INS AND CONTROL WIRING IN CONDUIT AS REQUIRED. PROVIDE TOGGLE DISCONNECT SWITCH. 7 PROVIDE SINGLE CHANNEL SURFACE MOUNTED MULTI -OUTLET ASSEMBLY AS REQUIRED. MOUNT AT t42' A.F.F. 8 CONNECT COMPLETE NEW WASHER VIA CIRCUIT INDICATED. PROVIDE 3P-60A, 400V, FUSIBLE DISCONNECT. FUSE PER MANUFACTURERS RECOMMENDATIONS. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. COORDINATE EXACT LOCATION PRIOR TO INSTALLATION. 9 PROM DE NEW,ADDITIONAL, RECEPTACLE AT WORK AREA. CONNECT COMPLETE VIA EXISTING RECEPTACLE CIRCUIT OF ADJACENT RECEPTACLE. 10 RECEPTACLES WITHIN OR SHALL BE MOUNTED AT +44" UNLESS SPECIFICALLY NOTED OTHERWISE. 11 CONNECT EXISTING FIRE I SMOKE DAMPER COMPLETE TO CIRCUIT MAINTAINED DURING DEMOLITION. PROVIDE WIRING IN CONDUIT AS REQUIRED. PROVIDE TOGGLE DISCONNECT SWITCH. 12 RECEPTACLE FOR WALL MOUNTED MON TOR. COORDINATE LOCATION AND MOUNTING HEIGHT WITH ARCHITECT. 13 RECEPTACLE FOR OR SURGICAL LIGHT POWER SUPPLY ON SHELF. COORDINATE LOCATION AND MOUNTING HEIGHT WITH ARCHITECT. 14 PROVIDE 8"%8PBACK BOX FLUSH IN WALL FOR MICROSCOPE CONTROL PANEL. PROVIDE (2)2"CONDUITS FROM CONTROL PANEL TO MICROSCOPE BOOM BASE. PROVIDE CONDUTS WITH BUSHINGAS REQUIRED. PROVIDE RELAY AS REQUIRED FOR FOOT PEDAL CONTROL OF ROOM LIGHT FIXTURES. CONTRACTOR SHALL VERIFY ALL MICROSCOPE REQUIREMENTS WITH SUPPLIER AND OWNER PRIOR TO INSTALLATION. 15 CONNECT COMPLETE TO SPARE 120V, M BREAKER MADE AVAILABLE BY DEMOLITION. 16 CONNECT COMPLETE TO SPARE 120V, 20A BREAKER IN PANEL INDICATED. 17 CONNECT COMPLETE CIRCU ITS INDICATED WTHI N THIS ROOM VIA SPARE 120V, 20A BREAKERS MADE AVAILABLE BY DEMOLITION. 10 PROVIDE NEW 120V, 20A BREAKERWITHIN EXISTING SPACE OF PANEL INDICATED AND CONNECT COMPLETE. 19 CONNECT RELOCATED EXISTING EQUIPMENT VACUUM PUMP INSTALLED IN PHASE ONE OF THIS PROJECT TO CIRCUIT THAT IS CURRENTLY SERVING THE VACUUM PUMP. PROVIDE TOGGLE SWITCH DISCONNECT. 20 PROVIDE NEW DUPLEX RECEPTACLE SAME HEIGHT AS EXISTING RECEPTACLE SERVING DI WATER SYSTEM. CONNECT TO EXISTING CIRCUIT COMPLETE. 21 PROVIDE 480V3P 130q FUSIBLE DISCONNECT. FUSE PER MANUFACTURER'S RECCOMENDATION. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. CORRIDOR f �1 Phase 2 -Enlarged Sub Sterile 250 Power Plan 11 =1'-0" CORRIDOR 280 SUB STERILE HP4, F50 81 5 Phase 2 - Enlarged Sub Sterile 281 Power Plan KEY PLAN MSKTD & Associates Architecture I Engineering I Interior Design 1715 Magnavmx Way 930 North Meridian Fort Wayne, IN 46804 Indianapolis, IN 46204 260.432.9337 1 317.917.1190 v .msktd.cwm PE10708732 STALE 9 l�^ i CD l^'E W i O Co f rO NW W W W LU � � L _O C LL v! + vi PROJECT NO. 733505-07-19 REV. DATE