Loading...
HomeMy WebLinkAboutMEP - First Floor Partial ME Plans2 I I Partial First Floor Mechanical Ductwork Plan -Area B �J 1/8"=1%01 7 8 I I c`mod 1 F1 FI = � �G it a rE (D (D �G EtiHH=6 ® EMH0CR2-6 — — D.5 e m I I anial First Floor Lighting Plan - Area B 7 s I I 2's �i0�� X 2' 6 11 r 1 L - - - - - - -I - - D.5 o I I RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel �1 Level Foundation Sanitary Plan -Area B-Phase II T T 4j I AEGL09I t TU4-602 .l 0 ®�:u4- 'R�.7 rgl2r L 1 TU-0-077 P TU-4 I O ❑ TLL4007 =TU4-025t TU�a-�Zr,,. AA. Partial First Floor Mechanical Piping Plan -Area B 7T 4$ it I EMLCR3 El 29 EMLCR3-41 `m' `�' 'r' 7 a rc a a ¢ aa'e 6s ..�a ww ww `tsJ 29 EMLCR3-43 — — — — O — — EsiML R3 42 O %ryML R3 43 P U U —RP6A-31 — — — RP6A-31 — — — RPBA-31 RP6A-33 RP6A-33 RP6A-33 Partial Frst Floor Power and Systems Plan ,/4" -a" �7,I°l �1 First Floo'F lumbing Plan -Phase II �J 118"=1' PLAN NOTES 1 COVER SUPPLY OPENING WITH EXPANDED METAL GRILLE. 2 COVER RETURN OPENING WITH EXPANDED METAL GRILLE. BALANCE RETURN TO 175 CFM. 3 BALANCE TERMINAL UNIT TO TOTAL CONNECTED AIRFLOW VALUES SHOWN ON PLAN. BALANCE REHEAT COIL TO ENSURE 75 -F LEAVING AIR TEMPERATURE WITH 120 -F ENTERING WATER TEMPERATURE. 4 CONNECT NEW CRITICAL LIGHT FIXTURES IN THIS ROOM I AREA TO NEW 277V, 20A, 1 P CRITICAL CIRCUIT INDIACTED ON PLAN, FROM PANEL'EMCR2'. 5 SUSPEND EXISTING LIGHT FIGURE(S)IN THIS ROOM TO+9'-0A.F.F. COORDINATE LOCATION OF FIXTURE TO AVOID DUCTWORK, PIPING AND ALL OTHER TRADES TO MAXIMIZE LIGHT DISTRIBUTION. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. 6 PROVIDE AMICO RETRACTABLE ELECTRICAL RECEPTACLE OR SIMILAR IN CEILING. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. 7 PROVIDE STAINLESS STEEL I-VY GROMMET CABLE PASS THROUGH SINGLE GANG WALL PLATE FOR OLYMPUS VIDEO EQUIPMENT CONNECTION SAME HEIGHT AS ADJACENT TELECOM OUTLET. VIDEO CABLING IS PROVIDED BY OLYMPUS AND INSTALLED BY CONTRACTOR. 8 PROVIDE STAINLESS STEEL I-1l2' GROMMET CABLE PASS THROUGH SINGLE GANG WALL PLATE. FOR OLYMPUS VIDEO EQUIPMENT CONNECTION SAME HEIGHT AS ADJACENT EMERGENCY QUAD RECEPTACLE. VIDEO CABLING IS PROVIDED BY OLYMPUS AND INSTALLED BY CONTRACTOR. 9 PROVIDE STAINLESS STEEL I-12' GROMMET CABLE PASS THROUGH SINGLE GANG WALL PLATE FOR OLYMPUS VIDEO EQUIPMENT CONNECTION ABOVE CEILING. VIDEO CABLING IS PROVIDED BY OLYMPUS AND INSTALLED BY CONTRACTOR. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. VIDEO CABLE SHALL BE ROUTED NEATLY WITH RETRACTABLE POWER RECEPTACLE CORD. 10 PROVIDE TELECOM OUTLET IN CEILING. TELECOM CABLE SHALL BE ROUTED NEATLY WITH RE TRACTABLE POWER RECEPTACLE CORD. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. 11 2'SUP. 12 CONNECT TS TO EXISTING SANITARY. 13 CONNECT 2' V TO EXISTING. 14 CONNECT 112'DOW& DHW TO EXISTING. 15 2'S ON - TV RISE, 112 DCW&DHW DROP. 16 3'4'MV,12' O DROP TO WALL OUTLETS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION, REFER TO RISER DIAGRAM 17 3'4'MV, IIY CO2 DROP TO CEILING OUTLETS. PROVIDE COLOR -CODED, GAS SPECIFIC HOSE ASSEMBLIES WITH HOSE RETRACTOR. 10 3'4- My, 12' O DROP TOWALL OUTLETS. REFER TOARCHITECTURAL DRAWINGS FOR EXACT LOCATION MEDICAL GAS SCHEDULE - EUS DESIGNATION DESCRIPTION QUANTITY MANUFACTURER CONFIGURATION STYLE OUTLETS NOTES O MV MA Y/AGD N2 NO2 CO2 SLIDE A WALLOUTLETS 1 AMICO OHMEDA(PIN INDEX) 1 7 - - - - - 1 - B WALLOUTLETS 1 AMICO OHMEDA(PIN INDEX) 1 7 - 1 - C CEILNGOUTIETS 1 AMICO DISS - 1 - - - - 1 - PROVIDE COLOR -CODED, GAS SPECIFIC HOSE ASSEMBLIES WITH HOSE RETRACTOR. First Floor Medical Gas Plan -Area &Phase II �J 1/8"=,,_0 KEY PLAN MSKTD & Associates Architecture I Engineering I Interior Design 1715 Magnavax Way 930 North Meridian Fort Wayne, IN 46804 Indianapolis, IN 46204 260.432.9337 317.917.1190 vnvv.msktd.cwm PE10708732 STATE OF ^MEAN) CD nE W O 4-1 (10 rOr �W ^� N W L LU _O �+ LL O U) = V) PROJECT NO. DATE 7335 05-07-19 REV. DATE 1 PR-01 - Phase 2 6/14/2019 SET DESCRIPTION FOR CONSTRUCTION SET SHEET TITLE First Floor Partial MEP Plans DATE: V//V`J/l