HomeMy WebLinkAboutMEP - First Floor Partial ME Plans2
I I
Partial First Floor Mechanical Ductwork Plan -Area B
�J 1/8"=1%01
7 8
I I
c`mod
1
F1 FI
= � �G
it a
rE
(D (D �G
EtiHH=6 ® EMH0CR2-6 — — D.5
e m
I I
anial First Floor Lighting Plan - Area B
7 s
I I
2's
�i0��
X 2' 6
11 r
1 L
- - - - - - -I - - D.5
o
I I
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
�1 Level Foundation Sanitary Plan -Area B-Phase II
T
T
4j I
AEGL09I t TU4-602
.l
0 ®�:u4- 'R�.7
rgl2r L
1 TU-0-077 P
TU-4 I
O ❑ TLL4007
=TU4-025t
TU�a-�Zr,,. AA.
Partial First Floor Mechanical Piping Plan -Area B
7T 4$
it I
EMLCR3
El 29 EMLCR3-41 `m' `�' 'r' 7
a rc a a ¢ aa'e
6s ..�a ww ww
`tsJ
29
EMLCR3-43 — — — — O — —
EsiML R3 42 O
%ryML R3 43
P U U
—RP6A-31 — — — RP6A-31 — — —
RPBA-31
RP6A-33
RP6A-33 RP6A-33
Partial Frst Floor Power and Systems Plan
,/4" -a"
�7,I°l
�1 First Floo'F lumbing Plan -Phase II
�J 118"=1'
PLAN NOTES
1 COVER SUPPLY OPENING WITH EXPANDED METAL GRILLE.
2 COVER RETURN OPENING WITH EXPANDED METAL GRILLE. BALANCE RETURN TO 175 CFM.
3 BALANCE TERMINAL UNIT TO TOTAL CONNECTED AIRFLOW VALUES SHOWN ON PLAN. BALANCE REHEAT COIL TO
ENSURE 75 -F LEAVING AIR TEMPERATURE WITH 120 -F ENTERING WATER TEMPERATURE.
4 CONNECT NEW CRITICAL LIGHT FIXTURES IN THIS ROOM I AREA TO NEW 277V, 20A, 1 P CRITICAL CIRCUIT INDIACTED
ON PLAN, FROM PANEL'EMCR2'.
5 SUSPEND EXISTING LIGHT FIGURE(S)IN THIS ROOM TO+9'-0A.F.F. COORDINATE LOCATION OF FIXTURE TO AVOID
DUCTWORK, PIPING AND ALL OTHER TRADES TO MAXIMIZE LIGHT DISTRIBUTION. PROVIDE ADDITIONAL SUPPORT
STRUCTURE AS REQUIRED.
6 PROVIDE AMICO RETRACTABLE ELECTRICAL RECEPTACLE OR SIMILAR IN CEILING. PROVIDE ADDITIONAL SUPPORT
STRUCTURE AS REQUIRED.
7 PROVIDE STAINLESS STEEL I-VY GROMMET CABLE PASS THROUGH SINGLE GANG WALL PLATE FOR OLYMPUS VIDEO
EQUIPMENT CONNECTION SAME HEIGHT AS ADJACENT TELECOM OUTLET. VIDEO CABLING IS PROVIDED BY OLYMPUS
AND INSTALLED BY CONTRACTOR.
8 PROVIDE STAINLESS STEEL I-1l2' GROMMET CABLE PASS THROUGH SINGLE GANG WALL PLATE. FOR OLYMPUS VIDEO
EQUIPMENT CONNECTION SAME HEIGHT AS ADJACENT EMERGENCY QUAD RECEPTACLE. VIDEO CABLING IS
PROVIDED BY OLYMPUS AND INSTALLED BY CONTRACTOR.
9 PROVIDE STAINLESS STEEL I-12' GROMMET CABLE PASS THROUGH SINGLE GANG WALL PLATE FOR OLYMPUS VIDEO
EQUIPMENT CONNECTION ABOVE CEILING. VIDEO CABLING IS PROVIDED BY OLYMPUS AND INSTALLED BY
CONTRACTOR. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED. VIDEO CABLE SHALL BE ROUTED NEATLY
WITH RETRACTABLE POWER RECEPTACLE CORD.
10 PROVIDE TELECOM OUTLET IN CEILING. TELECOM CABLE SHALL BE ROUTED NEATLY WITH RE TRACTABLE POWER
RECEPTACLE CORD. PROVIDE ADDITIONAL SUPPORT STRUCTURE AS REQUIRED.
11 2'SUP.
12 CONNECT TS TO EXISTING SANITARY.
13 CONNECT 2' V TO EXISTING.
14 CONNECT 112'DOW& DHW TO EXISTING.
15 2'S ON - TV RISE, 112 DCW&DHW DROP.
16 3'4'MV,12' O DROP TO WALL OUTLETS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION, REFER TO
RISER DIAGRAM
17 3'4'MV, IIY CO2 DROP TO CEILING OUTLETS. PROVIDE COLOR -CODED, GAS SPECIFIC HOSE ASSEMBLIES WITH HOSE
RETRACTOR.
10 3'4- My, 12' O DROP TOWALL OUTLETS. REFER TOARCHITECTURAL DRAWINGS FOR EXACT LOCATION
MEDICAL GAS SCHEDULE - EUS
DESIGNATION
DESCRIPTION
QUANTITY
MANUFACTURER
CONFIGURATION
STYLE
OUTLETS
NOTES
O
MV
MA
Y/AGD
N2
NO2
CO2
SLIDE
A
WALLOUTLETS
1
AMICO
OHMEDA(PIN INDEX)
1
7
-
-
-
-
-
1
-
B
WALLOUTLETS
1
AMICO
OHMEDA(PIN INDEX)
1
7
-
1
-
C
CEILNGOUTIETS
1
AMICO
DISS
-
1
-
-
-
-
1
-
PROVIDE COLOR -CODED, GAS SPECIFIC HOSE
ASSEMBLIES WITH HOSE RETRACTOR.
First Floor Medical Gas Plan -Area &Phase II
�J 1/8"=,,_0
KEY PLAN
MSKTD
& Associates
Architecture I Engineering I Interior Design
1715 Magnavax Way 930 North Meridian
Fort Wayne, IN 46804 Indianapolis, IN 46204
260.432.9337 317.917.1190
vnvv.msktd.cwm
PE10708732
STATE OF
^MEAN) CD
nE
W
O
4-1
(10
rOr
�W
^� N
W
L
LU
_O
�+ LL
O
U) = V)
PROJECT NO. DATE
7335 05-07-19
REV. DATE
1 PR-01 - Phase 2 6/14/2019
SET DESCRIPTION
FOR CONSTRUCTION
SET
SHEET TITLE
First Floor Partial MEP
Plans
DATE: V//V`J/l