HomeMy WebLinkAboutP0.1 - Plumbing Symbols and General Notes7 RELEASED FOR CONSTRUCTION MECHANICAL AND PLUMBING ABBREVIATIONS ABBREV. DESCRIPTION ABBREV. DESCRIPTION ABBREV. DESCRIPTION NE ARCHITECT AND END IN EER FHC FIRE HOSE CABINET OC ON CENTER AC OR ACU AI R CONDITION NG UNIT OR Al R CO MPRESSOR FIN FINISH OD OUTSIDE DIAMETER ACCU AIR COOLED CONDENSING UNIT FLA FULL LOAD AMPS OFCI OWNER FURNISHED/CONTRACTOR INSTALLED ADD AIR CONDITIONING CONDENSATE DRAIN FLR FLOOR OFOI OWNER FURNISHEDIOWNER INSTALLED AD ACCESS DOOR FODT FUEL OIL DAY TANK OM OXYGEN MANIFOLD ADJ ADJUSTABLE ORADJACENT FOP FUEL OIL PUMP OPER OPERATOR AFCV AIRFLOWCONTROL VALVE FOR FUEL OIL RETURN OPNG OPENING AFF ABOVE FINISHED FLOOR FOS FUEL OIL SUPPLY OSD OPEN SITE DRAIN AFMS AIR FLOW MEASURING STATION POST FUEL OIL STORAGE TANK AHU AIR HANDLING UNIT FOV FUEL OIL VENT P PUMP, PNEUMATIC OR PRESSURE ADD AIR PRESSURE DROP FP FIRE PROTECTION PC PLUMBING CONTRACTOR APPROX APPROXIMATE FPB FAN POWERED BOX PC PRESSURE DROP OR PERFORATED DIFFUSER AR AIR RECEIVER FPC FIRE PROTECTION CONTRACTOR PE PNEUMATIC ELECTRIC ARCH ARCHITECT FPM FEET PER MINUTE PF PREFILTERS AS AIR SEPARATOR FPS FEET PER SECOND PG PROPYLENE GLYCOL ATM ATMOSPHERE FPST FIRE PROTECTION STORAGE TANK PHC PREHEAT COIL AV ACID VENT FS FLOWSWITCH PIV POST INDICATOR VALVE AVMS AIR VOLUME MEASURING STATION FT FEET OR FLASH TANK PLT PLASTERTRAP AW ACID WASTE FTG FOOTING OR FITTING POC POINT OF CONNECTION FTR FIN TUBE RADIATION PPH POUNDS PER HOUR B BOILER PPM PARTS PER MILLION BCU BLOWER COIL UNIT G GAS,NATURAL PRO PRESSURE RELIEF DOOR BOD BACKDRAFT DAMPER GA GAUGE PREFAB PREFABRICATED BHP BRAKE HORSEPOWER GAL GALLON PRIES PRESSURE BI BACKWARD INCLINED BALM GALVANIZED FIRM PRESSURE REDUCING VALVE BLDG BUILDING GC GENERAL CONTRACTOR PSI POUNDS PER SQUARE INCH BOT BOTTOM GH GRAVITY HOOD PSIG POUNDS PER SQUARE INCH GAUGE BP BRINE PUMP GPH GALLONS PER HOUR PVC POLYVINYL CHLORIDE BST BULK SALT STORAGE GPM GALLONS PER MINUTE BTU BRITISH THERMAL UNIT TV GAS NATURAL VENT RA RETURN AIR OR RELIEF AIR BTUH BTU PER HOUR RA RADIATED H HUMIDIFIER, HUMIDITY OR HEIGHT RAT RETURN AIR TEMPERATURE CA COMPRESSED AIR HC HEATING COIL RIH REHEAT CAP CAPACITY HCP HEATING COIL PUMP (HOT WATER) RD ROOF DRAIN CAV CONSTANT AIR VOLUME HD HEAD RED RECEIVER CC COOLING COIL HE HEAT EXCHANGER RECIR RECIRCULATING CCP COOLING COIL PUMP HGT HEIGHT REF REFRIGERATOR CDS CONDENSATE PUMP DISCHARGE HO HUB OUTLET RF RETURN AIR FAN CENTRIF CENTRIFUGAL HOA HAND -OFF -AUTOMATIC RG RETURN GRILLE CFM CUBIC FEET PER MINUTE HORZ HORIZONTAL RH RELIEF HOOD OR RELATIVE HUMIDITY CFOI CONTRACTOR FURNISHEDIOWNER INSTALLED HOSP HOSPITAL RFC REHEAT COIL CH CHILLER HP HORSEPOWER OR HEATPUMP RLA RUNNING LOAD AMPS Cl CASTIRON HPR HI GH PRESSURE CONDENSATE RETURN RM ROOM CO CLEAN OUT FPS HIGH PRESSURE STEAM ROM REVERSE OSMOSIS VENT CO2 CARBON DIOXIDE HR HOUR ROP REVERSE OSMOSIS PUMP COL COLUMN HRC HEAT RECOVERY COIL ROST REVERSE OSMOSIS STORAGE TANK COM CARBON DIOXIDE MANIFOLD HTR HEATER RP RADIANT PANELS COMP COMPRESSOR HVAC HEATING, VENTILATION AND AIR CONDITIONING RPG RETURN PERFORATED GRILLE CONIC CONCRETE HW DOMESTIC HOT WATER RPM REVOLUTIONS PER MINUTE CONN CONNECTION HAD DOMESTIC HOT WATER RECIRC RPZ REDUCED PRESSURE BACKFLOW CONST CONSTRUCTION HWCP HOT WATER CIRCULATING PUMP REDD REQUIRED CONT CONTINUOUS HAP HEATING HOTWATERPUMP RV ROOFVENTILATOR CP CONDENSATE PUMP HAIR HEATING HOTWATER RETURN CPD CONDENSATE PUMP DISCHARGE HWS HEATING HOTWATERSUPPLY S SANITARYORSEWER DUN CABINET UNIT HEATER HX HEAT EXCHANGER SA SUPPLY AIR OR SOUND ATTENUATOR CV CENTRALVACUUM HZ HERTZ SB STEAM BOILER CW COLD WATER SC STEAM COIL CWM COLD WATER MAKE-UP IA INSTRUMENT AIR SCC STEAM CONDENSATE COOLER CWP CHILLED WATER PUMP LAC INSTRUMENT AIR COMPRESSOR SCCH SUBCOOLED CHILLER CAR CHILLED WATER RETURN LAD INSTRUMENT AIR DRYER, EQAD SCFM STANDARD CUBIC FEET PER MINUTE CWS CHILLED WATER SUPPLY ID INSIDE DIAMETER OR DIMENSION SCH SCHEDULE IFB INTEGRAL FACE AND BYPASS SCW SOFT COLD WATER (DOMESTIC) D DIFFUSER OR DAMPER IHOM IN-HOUSE OXYGEN MANIFOLD SO SUPPLY DIFFUSER OR SMOKE DAMPER DB DECIBELS OR DRY BULB IN INCHES SEC SECTION DC DUCT COIL INCL INCLUDE SENS SENSIBLE DCV DOUBLE CHECK VALVE INSUL INSULATED SEP SEWAGE EJECTOR PUMP DCWBP DOMESTIC COLD WATER BOOSTER PUMP INT INTERIOR SF SUPPLY AIR FAN DID DUAL DUCT INV INVERT SG SUPPLY GRILLE CDC DIRECT DIGITAL CONTROL P.S. INTERNATIONAL PIPE SIZING SHT SHEET DE DEAERATOR ISOL ISOLATION SHIN SOFT HOTWATER DEFL DEFLECTION SK SINK DEG DEGREE JT JOINT SMBH SENSIBLE MBH DEPT DEPARTMENT SMC SHEET METAL CONTRACTOR DHWBP DOMESTIC HOTWATER BOOSTER PUMP KAIC SHORT CIRCUIT RATING SP STATIC PRESSURE OR STORM PUMP DI DEIONIZED WATER KEC KITCHEN EQUIPMENT CONTRACTOR SPEC SPECIFICATIONS CIA DIAMETER KW KILOWATTS SQ SQUARE DISC DISCONNECT SOFT SQUARE FEET TISCH DISCHARGE L LENGTH SRV SAFETY RELIEF VALVE CIS DOWNSPOUT LAC LAB AIR COMPRESSOR ST STEAM TRAP DSWBP DOMESTIC SOFT WATER BOOSTER PUMP LAD LAB AIR DRYER STD STANDARD DUC DOOR UNDER CUT LAN LOCAL AREA NETWORK STM STORM DWG DRAWING LAT LEAVING AIR TEMPERATURE STIR STARTER DIN DISTILLED WATER LAV LAVATORY STRUCT STRUCTURAL DWBP DOMESTIC WATER BOOSTER PUMP LBD LINEARBAR DIFFUSER SV STEAM VENT DWH DOMESTIC WATER HEATER LBS POUNDS SW SWITCH LD LINEAR DIFFUSER SYS SYSTEM EA EXHAUST AIR LF LINEAR FOOT SZ SPRINKLERZONE EAT ENTERING AIR TEMPERATURE LFD LAMINAR FLOW DIFFUSER EBH ELECTRIC BASEBOARD HEATER LFT LEAVING FLUID TEMPERATURE T THERMOSTAT EC ELECTRICAL CONTRACTOR LOC LOCATION TB TERMINAL BOX ECC ENVIRONMENTAL CONTROL CONTRACTOR LPR LOW PRESSURE CONDENSATE RETURN TCC TEMPERATURE CONTROL CONTRACTOR ECG EGG CRATE GRILLE LPS LOW PRESSURE STEAM TDH TOTAL DISCHARGE HEAD ED EXHAUST DIFFUSER _VG LEAVING TDV TRIPLE DUTY VALVE EDC ELECTRIC DUCT COIL LVP LAB VACUUM PUMP TEMP TEMPERATURE EER ENERGY EFFICIENCY RATIO LWT LEAVING WATERTEMPERATURE THW TEMPERED HOT WATER EF EXHAUST AIR FAN TILL TEMPERATURE LOW LIMIT EFT ENTERING FLUID TEMPERATURE MA MEDICAL AIR TMV THERMOSTAT MIXING VALVE EG EXHAUST GRILLE OR ETHYLENE GLYCOL MAC MEDICAL AIR COMPRESSOR TMBH TOTAL MBH ELEC ELECTRIC MAD MEDICAL AIR DRYER TSP TOTAL STATIC PRESSURE ELEV ELEVATION MAI MEDICAL AIR INTAKE TW TEMPERED WATER EVER EMERGENCY MAT MIXED AIRTEMPERATURE TYP TYPICAL EMG EXTRUDED METAL GRILLE MAX MAXIMUM ENCL ENCLOSURE MB MOP BASIN UH UNIT HEATER ENTR ENTERING MBH BTUIHRX 1000 UNO UNLESS NOTED OTHERWISE EOM END OF MAIN DRIP MC MECHANICAL CONTRACTOR UR URINAL EQA EQUIPMENTAIR MCA MINIMUM CIRCUIT AMPACITY UVL ULTRA VIOLET LIGHT EQAC EQUIPMENTAIR COMPRESSOR MCC MOTOR CONTROL CENTER EQAI EQUIPMENTAIR INTAKE MD MOTORIZED DAMPER V VENT EQUIP EQUIPMENT MECH MECHANICAL VAC VACUUM EQV EQUIPMENTVACUUM MFR MANUFACTURER VAV VARIABLE AIR VOLUME EQVP EQUIPMENT VACUUM PUMP MH MANHOLE VB VACUUM BREAKER EQVV EQUIPMENT VACUUM VENT MIN MINIMUM VD VOLUME DAMPER (MANUAL) ERP ELECTRIC RADIANT PANEL MISC MISCELLANEOUS VEL VELOCITY ES EMERGENCY SHOWER MOCP MAXIMUM OVERCURRENT PROTECTION VSC VARIABLE SPEED CONTROLLER ESP EXTERNAL STATIC PRESSURE OR ELEVATOR SUMP PUMP MPSR MEDIUM PRESSURE CONDENSATE RETURN VTR VENT THROUGH ROOF ET EXPANSION TANK MPS MEDIUM PRESSURE STEAM VV VACUUM VENT EUH ELECTRIC UNIT HEATER MTD MOUNTED EW EMERGENCY EYEWASH MV MEDICAL VACUUM W WASTE, WATTS OR WIDTH EWC ELECTRIC WATER COOLER MVP MEDICAL VACUUM PUMP WAGD WASTE ANESTHESIA GAS DISPOSAL PUMP EAT ENTERING WATER TEMPERATURE WB WET BULB EXH EXHAUST N NORTH OR NITROGEN WI WITH EXIST EXISTING NA NOT APPLICABLE WIO WITHOUT EXT EXTERIOR INC NORMALLY CLOSED OR NOISE CRITERIA WC WATER CLOSET OR WATER COLUMN NIC NOT IN CONTRACT ACID WALL CLEAN OUT F DEGREES FAHRENHEIT NM NITROGEN MANIFOLD WFMD WATER FLOWMEASURING DEVICE F&B FACE B BYPASS NO NORMALLY OPEN, NITROUS OXIDE, OR NUMBER WG WATER GAUGE F&T FLOAT AND THERMOSTATIC TRAP NOM NOMINAL OR NITROUS OXIDE MANIFOLD ACT WEIGHT FIA FIRE ALARM NTS NOT TO SCALE Witt WALL HYDRANT FISD FIRE AND SMOKE DAMPER AM WATER METER FC FLEXIBLE CONNECTION 0 OXYGEN WP WEATHERPROOF FCU FAN COIL UNIT CA OUTSIDE AIR APT WATER PRESSURE DROP FD FLOOR DRAIN OR FIRE DAMPER OAT OUTSIDE AIR TEMPERATURE WS WATER SOFTENER FH FIRE HOSE OR FUME HOOD a POUND VALVE AND FITTING SYMBOLS TAGS PLAN VI EWS DETAIL V1 E CALIBRATED BALANCE VALVE V2 -D<a PIPING FLEXIBLE CONNECTION V3 --0 PIPE TURNED UP (UNLESS NOTED OTHERWISE) V4 D PIPE TURNED DOWN V5 PIPE OUT TOP V6 PIPE OUT BOTTOM V7 THREADED N I PPLE WICAP VB —iI PI PE WITH BLIND FLANGE V9 CONCENTRIC REDUCER MID ALL- ECCENTRIC REDUCER V11 �b CHECK VALVE V12 �� UNION V13 HHyy N.1Dd GATEVALVE V14 I Cl BALL VALVE V15 a^fi} M M GLOBE VALVE V16 �0 BUTTERFLY VALVE V17 TEMPERATURE CONTROL- 2 WAY MODULATING VALVE MIS TEMPERATURE CONTROL 2 WAY 2 POSITION MODULATING VALVE V19 0 TEMPERATURE CONTROL- 3 WAY MODULATING VALVE TEMPERATURE CONTROL- 3 WAY 2 POSITION MODULATING VALVE V20 C 0 V21 0 � SAFETY RELIEF VALVE V22 m STRAINER V23 -V - FLOW METER V24 0 S 0 FLOOR DRAIN V25 I I -J), ZONE CONTROL VALVE(OS&Y) V26 -EAr AUTOMATIC FLOW CONTROL VALVE V27 -0- FLOW MEASURING DEVICE V28 MANUAL AIR RELIEF VENT V29 AUTOMATIC AIR RELIEF VENT V30 -7EP- LUBRICATED PLUG VALVE V31 1� STEAM PRESSU RE REDUCING VALVE V32 ANGLEVALVE V33 GAS PRESSURE RELIEF VALVE V34 REFRIGERANT HOT GAS BY-PASS VALVE V35 SHUT-OFF COCK(HYDRONICS) V36 SOLENOIDVALVE V37 41- REFRIGERANT EXPANSION VALVE V38 a WATER PRESSURE REDUCINGREGULATING VALVE V39 - (D�- COMBINATION WATER PRESSURE RELIEF AND REDUCING VALVE V40 0 -{Tr STEAM TRAP V41 DIELECTRIC UNION BETWEEN STEEL AND COPPER V42 T1 STMIINER(STEAM) V43 P PRESSURE AND TEMPERATURE PLUG V44 REFRIGERANT SIGHT GLASS V45 THERMOMETER V46 (PEPRESS V=VAC T=TEMP) GAUGE V47 T SENSOR(T-TEMP HFH UMIDITY) V48 FLOW SWITCH V49 CLEAN OUT V51) . WATER HAMMER ARRESTOR OR ALARM PRESSURENACUUM SWITCH V51 INDICATED EXPANSION LOOP (COLD SPRUNG) V52— ANCHOR V53 — GUIDE V54 REDUCED PRESSURE BACIffLOW PREVENTER V55 ATMOSPHERIC VACUUM BREAKER V56 PRESSURE VACUUM BREAKER V57 REFRIGERANT SHUT-OFF VALVE V58 DOMESTIC WATER TEMPERATURE REGULATING VALVE V59 EXPANSION JOINT VBD L'-1 DIFFERENTIAL SWITCH V61 0 CENTRAL VACUUM OUTLET PLUMBING PIPING SYMBOLS 6'DCW, — ��j DOMESTIC COLD WATER _.. SIR 1 . DOMESTIC HOTWATER 6' DHW R - - - DOMESTIC HOT WATER RETURN FIRE PROTECTION 6' NG� NATURAL GAS 6'S� SANITARY —----6V�----— VENT 6' SCW — - - - - DOMESTIC SOFT COLD WATER GENERAL NOTES (REQUIRED TO COMPLETE THE SCOPE OF WORK) 1. ALL CONTRACT DOCUMENTS(SPECI FICATI ONS AND D RAWI NGS) ARE COMPLI MENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. 2. ALL CONFLI CTS SHALL BE BROUGHT TO THE ARCHITECTS OR ENGI NEERS ATTENTI ON IN ORDER TO ALLOW A CLARIFICATION TO BE ISSUED. ANY WORK COMPLETED WITHOUT THE CLARIFYING INFORMATION IS AT THE CONTRACTORS FINANCIAL RISK. 3. THE CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS AND ACCESSORIES TO CREATE A FULLY OPERATIONAL, CODE COMPLIANT AND TESTED SYSTEM. ALL MATERIALS AND ACCESSORIES REQUIRED TO CREATE THE FULLY OPERATIONAL SYSTEM SHALL BE INCLUDED IN THE COST OF THIS PROJECT. 4, THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR MAY AT THEIR OPTION MODIFY THE PIPE ROUTING IN ORDER TO CREATE A SYSTEM THAT MEETS THE INTENT OF THIS SET OF CONSTRUCTION DOCUMENTS. 5. THE CONTRACTOR SHALL INCLUDE ALL ITEMS THAT ARE REQUIRED TO ENSURE THAT THE ENTIRE SYSTEM IS FUNCTIONING IN COMPLIANCE WITH THE APPLICABLE CODES, AND MANUFACTURES INSTALLATION RECOMMENDATIONS AND OR REQUIREMENTS. 6. ALL CUTTING, DRILLING AND PATCHING OF WALLS, FLOORS ANDIOR STRUCTURAL MEMBERS FOR THE INSTALLATION OF THE PLUMBING AND FIRE PROTECTION SYSTEMS SHALL BE PROVIDED AS PART OF THE SCOPE OF THIS PROJECT. 7. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED OR MODIFIED IN ANY WAY WITHOUT THE STRUCTURAL ENGINEERS REVIEW AND PRIOR WRITTEN APPROVAL. B. PROVIDE FIRE STOPPING WHERE PIPES PENETRATE FIRE RATED FLOORS AND WALLS. FIRE STOPPING MATERIALS AND METHODS SHALL BE PER LOCAL AND STATE CODES AND REQUIREMENTS. 9. ALL PLUMBING SYSTEMS SHALL BE INSTALLED PER THE CURRENT PLUMBING CODE FOR THE LOCATION OF THE WORK BEING INSTALLED. 10. ALL PLUMBING EQUIPMENT, PIPING, FIXTURES, AND PIPE ACCESSORIES SHALL BE NSF 61, ANNEX G COMPLIANT. 11. ALL PIPING LOCATED WITHIN A RETURN AIR PLENUM SHALL COMPLY WITH A 25150 FLAME SMOKE RATING. ANY EXISTING PIPING DISCOVERED WITHIN A RETURN AIR PLENUM THAT DOES NOT COMPLY WITH THIS REQUIREMENT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR FURTHER CLARIFICATION. 12. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WATER AND WEATHER TIGHT BY THE APPROPRIATE TRADE COMPETENT IN COMPLETING THIS WORK. THE COST OF THIS WORK SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. 13. ALL VENT THROUGH ROOF VTR) LOCATIONS SHALL BE FIELD VERIFIED IN REGARDS TO ANY OUTDOOR INTAKE. LOCATION OF VTR SHALL BE NO LESS THAN AS REQUIRED BY THE LOCAL OR STATE CODES. 14. DO NOT ATTACH ANY CONSTRUCTION TO THE ROOF DECK JOIST BRIDGING, JOIST CROSS BRACING, PIPING, CONDUIT, DUCTWORK OR ANY OTHER NON-STRUCTURAL ITEM. 15. DO NOT WELDOR DRILL INTO STRUCTURAL STEEL OR JOIST; INSTEAD USE CLAMPS, TIE WIRE, THRU-BOLTS WITH WASHERS 16. DO NOT USE ANY PVC,PLASTIC,ETC. IN PLENUM OR DEMISING WALLS UNLESS FIRE WRAPPED. ALL WOOD BLOCKING AND NAILERS, CONCEALED OR NOT SHALL BE FIRE RETARDANT TREATED. 17. DO NOT PENETRATE BUILDING WALLS FOR ANY DUCTING OR VENTING; ROUTE THROUGH ROOF USING OWNERS ROOFING CONTRACTOR. 18. VENT THROUGH ROOF INSTALLATION; ALL ROOFING WORK SHALL BE COMPLETED BY THE OWNERS ROOFING CONTRACTOR. THE COST SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. 19. PIPING BELOW GROUND SHALL BE SERVICE -WEIGHT CAST IRON OR SCHEDULE 4D PVC. NO HUB PIPING OR FERNCO CONNECTIONS ARE NOT PERMITTED BELOW GRADE. 20 DOMESTIC WATER PIPING ABOVE GRADE SHALL BE TYPE T'WATER TUBE. 21. ALL PIPING SHALL BE PROPERLY SUSPENDED BY THE STRUCTURE PER THE LOCAL CODES. 24. GAS PIPING SUPPORTED ON THE ROOF SHALL BE PROVIDED FREE FLOATING PREFABRICATED SUPPORTS OR EQUIPMENT SUPPORTS WITH ROLLER ASSEMBLIES. WOOD SUPPORTS ALL NOT BE PERMITTED. 25. ALL GAS PIPING SHALL BE PROVIDED PIPE LABELS IDENTIFYING THE GAS PRESSURE. 26. ALL GAS PIPING SHALL BE INSTALLED PER THE LOCAL CODES FOR MATERIALS AND INSTALLATIONS REQUIREMENTS. 27. ALL SHUT -DOWN OF UTILITIES AND FIRE PROTECTION SYSTEMS SHALL BE ARRANGED WITH NO LESS THAN SEVEN(7) DAYS NOTICE TO THE OWNER. WORK MAY NOT COMMENCE UNLESS WRITTEN APPROVAL IS PROVIDED BY THE OWNER. 28, ALL DOMESTIC WATER BRANCH PIPES SERVING FIXTURES OR EQUIPMENT WITH FAST ACTING OR ELECTRONIC VALVES SHALL BE PROVIDED WATER HAMMER ARRESTORS. 29. ALL BRANCH PIPES FROM DOMESTIC WATER MAINS SHALL BE PROVIDED QUARTER TURN FULL PORT BALL VALVES ON THE BRANCH PIPE JUST ADJACENT TO THE MAIN. FLOOR PLAN SYMBOLS TYP 1 SECTION WITH TOP NUMBER INDICATING SECTION DESIGNATION AND BOTTOM A101 NUMBER INDICATING DRAWING THAT SECTION IS CUT ON 1 TYP DETAIL WITH TOP LETTER INDICATING DETAIL A101 DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT DETAIL IS REFERENCED ON OR DRAWING THAT DETAIL IS DRAWN ON 7O PLAN NOTE (� UN THERMOSTAT -'N' INDICATING NIGHT SETBACK THERMOSTAT O HUMIDISTAT A. GENERAL NOTEHAT SECTION IS DRAWN ON 1. PLAN NOTE LIST 4%ir CONNECTION OF NEWWORK TOEXISTING H V ^W NO W am IM 2 Z O 0 LLI C / MSKTD & Associates Architecture I Engineering I Interior Design 1715 Magnavox Way 930 North Meridian Fort Wayne, IN 46804 Indianapolis, IN 46204 260.432.9337 1 317.917.1190 w .msktd.cwm Opnn4U1p `��ANN A. � 4oe g PE10708732 3z _ P�tL STATE 9 A ? W TOT V! E W co Q }r O ^� W 0 0 CIO W Vi V/ W VJ i 0 O LL Z V/ `V Cc: O 0 O (`) O U) VJ PROJECT NO. DATE 7335 05-07-19 REV. DATE SET DESCRIPTION SHEET TITLE Plumbing Symbols and General Notes Subject to compliance with all regulations of State and Local Codes City of Cannel 1�01AG19 DATE: V//V`U/-IU SHEET NUMBER P0.1