HomeMy WebLinkAboutP3.2- - Second Floor Medical Gas Plan -Area B2 GENERAL NOTES (REQUIRED TO COMPLETE THE SCOPE OF WORK) A. ALL CONTRACT DOCUMENTS (SPECIFICATIONS AND DRAWINGS) ARE COMPLIMENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. ALL CONFLICTS SHALL BE BROUGHT TO THE ARCHITECTS OR ENGINEERS ATTENTION IN ORDER TO ALLOW A CLARIFICATION TO BE ISSUED. ANY WORK COMPLETED WITHOUT THE CLARIFYING INFORMATION IS AT THE CONTRACTORS FINANCIAL RISK. B. THE CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS AND ACCESSORIES TO CREATE A FULLY OPERATIONAL, CODE COMPLIANT AND TESTED SYSTEM. ALL MATERIALS AND ACCESSORIES REQUIRED TO CREATE THE FULLY OPERATIONAL SYSTEM SHALL BE INCLUDED IN THE COST OF THIS PROJECT. C. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR MAY AT THEIR OPTION MODIFY THE PIPE ROUTING IN ORDER TO CREATE A SYSTEM THAT MEETS THE INTENT OF THIS SEE OF CONSTRUCTION DOCUMENTS. D. THE CONTRACTOR SHALL INCLUDE ALL ITEMS THAT ARE REQUIRED TO ENSURE THAT THE ENTIRE SYSTEM IS FUNCTIONING IN COMPLIANCE WITH THE APPLICABLE CODES, AND MANUFACTURES INSTALLATION RECOMMENDATIONS AND OR REQUIREMENTS. E. ALL CUTTING, DRILLING AND PATCHING OF WALLS, FLOORS ANDIOR STRUCTURAL MEMBERS FOR THE INSTALLATION OF THE PLUMBING AND FIRE PROTECTION SYSTEMS SHALL BE PROVIDED AS PART OF THE SCOPE OF THIS PROJECT. F. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED OR MODIFIED IN ANYWAY WITHOUT THE STRUCTURAL ENGINEERS REVIEW AND PRIOR WRITTEN APPROVAL. G. PROVIDE FIRE STOPPING WHERE PIPES PENETRATE FIRE RATED FLOORS AND WALLS. FIRE STOPPING MATERIALS AND METHODS SHALL BE PER LOCAL AND STATE CODES AND REQUIREMENTS. H. ALL PLUMBING SYSTEMS SHALL BE INSTALLED PER THE CURRENT PLUMBING CODE FOR THE LOCATION OF THE WORK BEING INSTALLED. L ALL PLUMBING EQUIPMENT,PIPING,FIXTURES, AND PIPE ACCESSORIES SHALL BE NSF 61, ANNEX G COMPLIANT. J. ALL PIPING LOCATED WITHIN A RETURN AIR PLENUM SHALL COMPLY WITH A 25150 FLAME SMOKE RATING. ANY EXISTING PIPING DISCOVERED WITHIN A RETURN AIR PLENUM THAT DOES NOT COMPLY WITH THIS REQUIREMENT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR FURTHER CLARIFICATION. K. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WATER AND WEATHER TIGHT BY THE APPROPRIATE TRADE COMPETENT IN COMPLETING THIS WORK. THE COST OF THIS WORK SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. p L. DO NOT ATTACH ANY CONSTRUCTION TO THE ROOF DECK JOIST BRIDGING, JOIST 4.'4.2 4.3 4.6 4.7 5.1 6 7 8 9 9.3 99.45 9.8 110.2 CROSS BRACING,PIPING,CONDUIT, DUCTWORK OR ANY OTHER NON- STRUCTURAL ITEM. M. DO NOT WELDOR DRILL INTO STRUCTURAL STEEL OR JOIST; INSTEAD USE CLAMPS, TIE WIRE, THRU-BOLTS WITH WASHERS N. DO NOT USE ANY PVC, PLASTIC, ETC. IN PLENUM OR DEMISING WALLS UNLESS FIRE WRAPPED. ALL WOOD BLOCKING AND HAILERS, CONCEALED OR NOT SHALL BE FIRE II II RETARDANT TREATED. 0. DO NOT PENETRATE BUILDING WALLS FOR ANY DUCTING OR VENTING; ROUTE THROUGH ROOF USING LANDLORDS ROOFING CONTRACTOR. P. VENT THROUGH ROOF INSTALLATION; ALL ROOFING WORK SHALL BE COMPLETED BY THE LANDLORDS ROOFING CONTRACTOR. THE COST SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. —�11 1 .9A Q. PIPING BELOW GROUND SHALL BE SERVICE -WEIGHT CAST IRON ORSCHEDULE40 PVC. — + TT7 NO HUB PIPING OR FERNCO CONNECTIONS ARE NOT PERMITTED BELOW GRADE. e— e—————WATER SO]R. DOMESTIC WATER PIPING ABOVE GRADE SHALL BE TYPE'L'WATER TUBE. S. ALL PIPING SHALL BE PROPERLY SUSPENDED BY THE STRUCTURE PER THE LOCAL CODES. E9NBBL-T aa--11 A3 A3 T. ALL PIPING INSULATED SHALL BE WITH PLENUM RATED MATERIALS. 202A U. FLOOR DRAINS SHALL BE PROVIDED WITH TRAP PRIMERS. TRAP PRIMER PIPES SHALL BE WAITING FIELD ROUTED AND FIELD INSTALLED. STORAGE€FAN ROOM V WITH NO LESS THAN SEVEN (])N OF UTILITIES AND FIRE DAYS NOTICO TO THE LANDLORDN SYSTEMS S WORK MAY OTHALL BE GEO 287 261 COMMENCE UNLESS WRITTEN APPROVAL IS PROVIDED BY THE OWNER. � �L8 W. CTINGORELECTRONICLVESSALLBEVIDEOATERHARESTO. � - - - - - - - � - tF � �A.HS� ACTING OR ELECTRONIC VALVES SHALL BE PROVIDED WATER HAMMER ARRESTORS. !B \_� X. ALL BRANCH PIPES FROM DOMESTIC WATER MAINS SHALL BE PROVIDED QUARTER TURN FULL PORT BALL VALVES ON THE BRANCH PIPE JUST ADJACENT TO THE MAIN. .4.1 — — — — �FCAMERA INSPECTIONS A N LOCATING OCATI Y D HALL B PRIORTO ED PRANG ANY WORK. ALL Q [TR B.2 B.2 CAMERA INSPECTIONS CONTRACTOR LMAYM GSHALL TING OFLETE, PRIORT-BINSTALLATION 219 DOF ANY OCUMENTS PIPE. CONTRACTOR MAY ENTIRE PROJECT. ROJECT. OF PIPE, KEEP AS -BUILT STAIR REG CORRIDOR STAIR DOCUMENTS THROUGHOUT THE ENTIRE PRW ECT. E2 REG1 201 REG3 213A LASER OM 0 REFER TO ALL RISER DIAGRAMS FOR ADDITIONAL INFORMATION ECH CHASE 206 208 ONSULT p3 EL R CORRIDOR IO HAZA 0 /JU'A'Tl 204 ztt z31 s 1 26s 18 ON PIPE SIZING AND ROUTING. CONTRACTOR SHALL FIELD VERIFY ALL MAINS IN FLOOR BELOW PRIOR TO BID I I zm I cowwooR r I 213 CO2050R — O O — — — — — — Edr — — — — — O 232 ry OFFICE JAN EQUIPMENT STORAGE 210 — ULT OFFICE 221A 220 CO ZR010 DECONTAMINATION CENTRALSTERILE 721 �211B 233 WOME CLEAN STORAGE 236 CORRI WF 22gREIPOST' Bd PREIPOST OP R00 REIPOST OP ROOM PREIPOST OP ROOM OFFICE 224 225 226 22] ® ® ® I I II 1 Milo s CORRIDOR CORRIDOR CORRIDOR 231 CORRIDOR 228 243 CORRIDOR 7LINEN STAFF LOUNGE ❑ ME0253 0 PREPOSTOP R00 II�� TOP\ TOILET 242 258 fJ i 260 277 OR qi NPE C SOILED UTILITY 1 — — — ❑ BIOK/55 —LORKSTATION LOCKER ROOM OR p2 TVPEc SUB BEERI EQUIPMENT STORAG RAGE PREIPOST OPR CORR90R DA161LET g iR'MA7712'MV EE PATIENT ROM 269 CORRIDOR 112'MA— 112'N CORRIDOR O RK AREA CORRIDOR 2 1'MV 30 -112.0 a 'N 314'O 112'NO TOILET 1 246 251 3140 WAGD -112'N 280 ❑ 270 --jl p -11 10NSCRUBAREA p SU STERILE 5 SUBSTERILE NU TATIONj� 4 112"0 1283 5 0 24] 250 2 55 A t2 MA 112"NO SUB STERILE RECOVERY WORK 2 3ATIO TOILET 4' WAGD 117 IN / -� 290 271 ... P AGD 314'WAGD T LINEN 2 T I a E 2 D L a D 2 oas I III 1 0 OR pPEC pR p4 TYPE ] 2B� Iiii�.--. D 2 248O 269 0 2 D PATIENT RECOV YI J 0 2 al 1� ECOVERY LECOI 274 �t t 289 2gg 3C p2 F RELEASED FOR CONSTRUCTION id Floor Medical Gas Plan -AreaB Subject to compliance with all regulations VI of State and Local Codes City of Carmel ' V"`JDw(}a�jOJ� I OFFICE PLAN NOTES I 3MWAG IWIIII III if2'Q, 717N DROP/RISE TO MEDICAL GAS20NEVALVE. 2 3'4'MV,314'WAGD, 7170, 72'MA, 717No, 7I7N DROP TO CEILING OUTLET. 3 314'MV DROP TO WALL OUTLETS. 4 7f2'N DROP TO NITROGEN CONTROL PANEL. — -D D 5 EXISTING ZONE VALVE. 6 IXISTI NG MASTER AWRM PANEL. 7 FROM DE Ill' NITROGEN CONNECTION WITH SHUT-OFF VALVE AND IN LINE REGULATOR. COORDINATE CONNECTION TYPE WITH EQUIPMENT PROVIDER. E7 E_7 KEY PLAN MSKTD & Associates Architecture I Engineering I Interior Design 1715 Magnavox Way 930 North Meridian Fort Wayne, IN 46804 Indianapolis, IN 46204 260.432.9337 1 317.917.1190 vnvv.msktd.cwm PE10708732 STATE a CD co V, \V }r � 0 W 0 i ^^ rn�i C ' }W}••�� L' \ LU U) / 0 �/� v5i 0 WIMILLz 0 O L 0 M U) O U) PROJECTNO. DATE 7335 05-07-19 REV. DATE SET DESCRIPTION SHEET TITLE Second Floor Medical Gas Plan - Area B SHEET NUMBER P302momal B DATE: V//L)U/-IU