HomeMy WebLinkAboutP6-1 - Plumbing Schedules a Details2 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel 1�01NGIDwTc711DA.eL DOMESTIC WATER SUPPLY PIPING PRESSURE REGULATING VALVE FLOW CONTROL VALVE; REFER TO PLANS FOR GPM WATER HAMMER ARRESTOR'E' PRESSURE GAUGE STERILIZERS AND WASHERS PIPING DIAGRAM NO SCALE 7' TO SPOUT BI 30 IM /E CLINIC SERVICE SINK ROUGH -IN DETAIL NO SCALE TERMINATE SLEEVE FLUSH WITH FINISHED WALL FIRESTOP EACH SIDE OF SLEEVE AS SPECIFIED IN DIV 7 FINISHED WALL SURFACE OF RATED ASSEMBLY INTERIOR FIRE RATED WALLS TERMINATE SLEEVE FLUSH WITH FINISHED WALL PIPE FIRESTOP EACH SIDE OF SLEEVE AS SPECIFIED IN DIV 7 FINISHED WALL SURFACE OF RATED ASSEMBLY PLUMBING FIXTURE SCHEDULE CONNEC IONSIZES FlXTURE MANUFACTURE REFERENCEMODEL WATER USAGE NOTES HOT HOT COLT) TEPID WASTE VENT WATER WATER SK-1(FU(11RE) ELKAY LRAD1918 - T T - - - - SK-1(FAUCET) SPEAKMAN SEF-1800.CA-TW 1.5GPM - - la. la. la. - SK-21FIMRE) ELKAY EWSF390226KWG WITH LK1 BB - T T 1/2' 1/2' - - SK-2(FAUCET) ELKAY LK394A 22 GPM - - - - 11T PROVIDE FAUCET FOR EACH OF THE THREE STATIONS OF THE SCRUB SINK SK-3 (FIXTURE) AMERICAN AMERICAN 95MS99.020 WITH _ 4- T 71009&201.081 ZURN WITH ZWM2AV-BWN WITH SK-3 (FAUCET) CHICAGO FAUCET 785500-XL-WM AND HAND - - - 11IT 3W - - SPRAY SK4 ELKAY EWSF13026KWC 2.2 GPM T T 12' 12' - SPOUT AND DRAIN INCLUDED LAVA (FIXTURE) AMERICAN 0366.041 - T T - - - AMERICAN DISABILITIES ACT (AM) STANDARD INSTALL PER REQUIREMENTS OF THE ACCESSIBILITY GUIDELINES LAVA (FAUCET) CHICAGOFAUCET 116AMABA OS GPM - - 10 10 - - PLUMBING EQUIPMENT SCHEDULE FIXTURE REFERENCE MANUFACTURE REFERENCE MODEL VOLTAGE PHASE HPIWATT EFFICIENCY GALLONS STORAGE BTU INPUT CAPACITY NOTES VB-1 WATTS BIXI - - - - - - 21 GPM( au13 PSI PD LEAD FREE RPZ-1 ZURN WILKINS 375-XL - - - - - - SO GPM @ 16 PSI PD LEAD FREE A0l GAST MANUFACTURING 1HD-M853 D-f0 460 3 2 - - - 9.1 CFM@f00 PSIG - DI-1 (CARBON TANK) AQUASYSTEMS (2) CARBON BED 3.6 - - - - - - 10 GPM @ 14 PSI PD - (2) NEW MIXED BEDS IN COMBINATION WITH (2) DFi(MIXED BED) AQUASYSTEMS (2)MIXED BEDS 3S - - - - - - 15 GPM@25 PSI PD EXISTING MIXED BEDS. SYSTEM TOTAL WILL HAVE MIXED BEDS (1) NEW QUALITY LIGHT IN COMBINATION WITH (1) DO(RESILITE) AQUASYSTEMS (1)QUALITY LITE 120 1 - - - - - EXISTING QUALITY LIGHT. SYSTEM TOTAL WILL HAVE (2) QUALITY LIGHTS MEDICAL GAS SCHEDULE - PHASE 2 DESIGNATION DESCRIPTION QUANTITY MANUFACTURER CONFIGURATION STYLE OUTLETS NOTES O MV MA WAGD N2 NO2 CO2 SLIDE A AREA ALARM PANEL 1 AMICO B ZONEVALVE 2 AMICO C WALLOUTLETS 2 AMICO CHEMETRON I I MATCH EXISTING 0 CEILING OUTLETS 6 AMICO DISS OUTLET I I I I I 1 - - - - - PROVIDE CO_OR-CODm, GAS SPECIFIC HOSE ASSEMBLIES WITH HOSE RETRACTOR. E NITROGEN CONTROL PANEL 2 AMICO GAS CONTROL PANEL - - - - - - NOTE: QUANTITIES LISTED ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE FOR FINAL QUANTITIES. PIPE SLEEVE TO BE SIZED TO PASS PIPE THRU SLEEVE AND ALLOW SPACE FOR SEALANT TO MEET UL-LISTING SLEEVE WATER STC WALL O PIPE SLEEVE TO BE SIZED TO PASS PIPE AND INSULATION THRU AND ALLOW SPACE FOR BE/ MEET UL-LISTING PIPE PIPE INSULATION TO CONT THRU WALL NONCOMBUSTIBLE SEALANT � FINISHED WALL SURFACE EXTERIORWALLS NOTESUK5MUKe-Ke5I5lANl GUKKIUUHwALLs O PROVIDE ESCUTCHEON PLATE FLUSH AGAINST WALLAND OF SIZE TO COMPLETELY COVER OPENING IN EXPOSED AREAS ONLY. O SEE SPECIFICATION SECTIONS FOR FURTHER REQUIREMENTS INCLUDING FLOORSLEEVES. O3 LOCATE FIRESTOP LABEL ON EACH SIDE OF PENETRATION SOTHAT IT IS VISIBLE FROM AN ACCESSIBLE LOCATION ABOVE CEILING. O4 INCLUDES FIRE WALLS, FIRE BARRIERS, SMOKE BARRIERS, AND FIRE PARTITIONS. PIPE PENETRATION DETAIL NO SCALE LEEVE PIPE rATIC PIPE ;'LINK -SEAL' ILL ANNULAR GAPS ROUND PIPES ON ACH SIDE OF WALL SSEMBLY FLOOR DRAIN SCHEDULE FIXTURE REFERENCE MANUFACTURE JR. SMITH REFERENCE MODEL DIAMETER NOTES FD-1 2O05T37 T 4' FS-1 JR. SMITH 330-Y04 1TX12' 4' TYPICAL WHEELCHAIR LAVATORY DETAIL NO SCALE PROVIDE HORIZONTAL BRACE FOR PIPE 5 INCHES B LARGER AT EVERY BRANCH OPENING OR CHANGE OF DIRECTION BY THE USE OF BRACES, BLOCKS OR RODDING TO PREVENT MOVEMENT IN ACCORDANCE WITH CISPI STD. �1 NO-I1UB PIPE FITTING BRACE DETAIL NO SCALE rmuuti MSKTD & Associates Architecture I Engineering I Interior Design 1715 Magnavox Way 930 North Meridian Fort Wayne, IN 46804 Indianapolis, IN 46204 260.432.9337 1 317.917.1190 mxvri.msktd.com PE10708732 STATE a CD oT EN N ^, W co � O }r p (n ^ W O3 0. 4-1 �l^'`J ^L^, r}n1 `+ / L' \ LU U) / 0 /� .,SJ 0 z �r lwilmom}1�', Q n ,CD (o 0. CD U) //�� VJ PROJECT NO. DATE 7335 05-07-19 REV. DATE SET DESCRIPTION SHEET TITLE Plumbing Schedules and Details DATE: V//L)U/-IU SHEET NUMBER P6-1 B