HomeMy WebLinkAboutP6-1 - Plumbing Schedules a Details2
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
1�01NGIDwTc711DA.eL
DOMESTIC WATER SUPPLY PIPING
PRESSURE REGULATING VALVE
FLOW CONTROL VALVE;
REFER TO PLANS FOR GPM
WATER HAMMER ARRESTOR'E'
PRESSURE GAUGE
STERILIZERS AND WASHERS PIPING DIAGRAM
NO SCALE
7' TO SPOUT BI
30
IM
/E
CLINIC SERVICE SINK ROUGH -IN DETAIL
NO SCALE
TERMINATE SLEEVE FLUSH
WITH FINISHED WALL
FIRESTOP EACH SIDE
OF SLEEVE AS
SPECIFIED IN DIV 7
FINISHED WALL SURFACE
OF RATED ASSEMBLY
INTERIOR FIRE RATED WALLS
TERMINATE SLEEVE
FLUSH WITH FINISHED WALL
PIPE
FIRESTOP EACH SIDE
OF SLEEVE AS
SPECIFIED IN DIV 7
FINISHED WALL SURFACE
OF RATED ASSEMBLY
PLUMBING FIXTURE SCHEDULE
CONNEC IONSIZES
FlXTURE
MANUFACTURE
REFERENCEMODEL
WATER USAGE
NOTES
HOT
HOT
COLT)
TEPID
WASTE
VENT
WATER
WATER
SK-1(FU(11RE)
ELKAY
LRAD1918
-
T
T
-
-
-
-
SK-1(FAUCET)
SPEAKMAN
SEF-1800.CA-TW
1.5GPM
-
-
la.
la.
la.
-
SK-21FIMRE)
ELKAY
EWSF390226KWG WITH LK1 BB
-
T
T
1/2'
1/2'
-
-
SK-2(FAUCET)
ELKAY
LK394A
22 GPM
-
-
-
-
11T
PROVIDE FAUCET FOR EACH OF THE THREE STATIONS OF THE
SCRUB SINK
SK-3 (FIXTURE)
AMERICAN
AMERICAN
95MS99.020 WITH
_
4-
T
71009&201.081
ZURN WITH
ZWM2AV-BWN WITH
SK-3 (FAUCET)
CHICAGO FAUCET
785500-XL-WM AND HAND
-
-
-
11IT
3W
-
-
SPRAY
SK4
ELKAY
EWSF13026KWC
2.2 GPM
T
T
12'
12'
-
SPOUT AND DRAIN INCLUDED
LAVA (FIXTURE)
AMERICAN
0366.041
-
T
T
-
-
-
AMERICAN DISABILITIES ACT (AM)
STANDARD
INSTALL PER REQUIREMENTS OF THE ACCESSIBILITY GUIDELINES
LAVA (FAUCET)
CHICAGOFAUCET
116AMABA
OS GPM
-
-
10
10
-
-
PLUMBING EQUIPMENT SCHEDULE
FIXTURE
REFERENCE
MANUFACTURE
REFERENCE MODEL
VOLTAGE
PHASE
HPIWATT
EFFICIENCY
GALLONS
STORAGE
BTU INPUT
CAPACITY
NOTES
VB-1
WATTS
BIXI
-
-
-
-
-
-
21 GPM( au13 PSI PD
LEAD FREE
RPZ-1
ZURN WILKINS
375-XL
-
-
-
-
-
-
SO GPM @ 16 PSI PD
LEAD FREE
A0l
GAST MANUFACTURING
1HD-M853 D-f0
460
3
2
-
-
-
9.1 CFM@f00 PSIG
-
DI-1 (CARBON TANK)
AQUASYSTEMS
(2) CARBON BED 3.6
-
-
-
-
-
-
10 GPM @ 14 PSI PD
-
(2) NEW MIXED BEDS IN COMBINATION WITH (2)
DFi(MIXED BED)
AQUASYSTEMS
(2)MIXED BEDS 3S
-
-
-
-
-
-
15 GPM@25 PSI PD
EXISTING MIXED BEDS. SYSTEM TOTAL WILL HAVE
MIXED BEDS
(1) NEW QUALITY LIGHT IN COMBINATION WITH (1)
DO(RESILITE)
AQUASYSTEMS
(1)QUALITY LITE
120
1
-
-
-
-
-
EXISTING QUALITY LIGHT. SYSTEM TOTAL WILL HAVE
(2) QUALITY LIGHTS
MEDICAL GAS SCHEDULE - PHASE 2
DESIGNATION
DESCRIPTION
QUANTITY
MANUFACTURER
CONFIGURATION
STYLE
OUTLETS
NOTES
O
MV
MA
WAGD
N2
NO2
CO2
SLIDE
A
AREA ALARM PANEL
1
AMICO
B
ZONEVALVE
2
AMICO
C
WALLOUTLETS
2
AMICO
CHEMETRON
I
I
MATCH EXISTING
0
CEILING OUTLETS
6
AMICO
DISS OUTLET
I
I
I
I
I
1 - -
- - -
PROVIDE CO_OR-CODm, GAS SPECIFIC HOSE
ASSEMBLIES WITH HOSE RETRACTOR.
E
NITROGEN CONTROL
PANEL
2
AMICO
GAS CONTROL PANEL
-
-
-
-
-
-
NOTE: QUANTITIES LISTED ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE FOR FINAL QUANTITIES.
PIPE SLEEVE TO BE SIZED TO PASS
PIPE THRU SLEEVE AND ALLOW SPACE
FOR SEALANT TO MEET UL-LISTING
SLEEVE WATER STC
WALL
O
PIPE SLEEVE TO BE SIZED TO PASS
PIPE AND INSULATION THRU
AND ALLOW SPACE FOR BE/
MEET UL-LISTING
PIPE
PIPE INSULATION TO
CONT THRU WALL
NONCOMBUSTIBLE
SEALANT
� FINISHED WALL
SURFACE
EXTERIORWALLS
NOTESUK5MUKe-Ke5I5lANl GUKKIUUHwALLs
O PROVIDE ESCUTCHEON PLATE FLUSH AGAINST WALLAND OF SIZE TO COMPLETELY COVER OPENING
IN EXPOSED AREAS ONLY.
O SEE SPECIFICATION SECTIONS FOR FURTHER REQUIREMENTS INCLUDING FLOORSLEEVES.
O3 LOCATE FIRESTOP LABEL ON EACH SIDE OF PENETRATION SOTHAT IT IS VISIBLE FROM AN ACCESSIBLE
LOCATION ABOVE CEILING.
O4 INCLUDES FIRE WALLS, FIRE BARRIERS, SMOKE BARRIERS, AND FIRE PARTITIONS.
PIPE PENETRATION DETAIL
NO SCALE
LEEVE
PIPE
rATIC PIPE
;'LINK -SEAL'
ILL ANNULAR GAPS
ROUND PIPES ON
ACH SIDE OF WALL
SSEMBLY
FLOOR
DRAIN
SCHEDULE
FIXTURE
REFERENCE
MANUFACTURE
JR. SMITH
REFERENCE MODEL
DIAMETER
NOTES
FD-1
2O05T37
T
4'
FS-1
JR. SMITH
330-Y04
1TX12'
4'
TYPICAL WHEELCHAIR LAVATORY DETAIL
NO SCALE
PROVIDE HORIZONTAL BRACE FOR PIPE
5 INCHES B LARGER AT EVERY BRANCH
OPENING OR CHANGE OF DIRECTION
BY THE USE OF BRACES, BLOCKS OR
RODDING TO PREVENT MOVEMENT IN
ACCORDANCE WITH CISPI STD.
�1 NO-I1UB PIPE FITTING BRACE DETAIL
NO SCALE
rmuuti
MSKTD
& Associates
Architecture I Engineering I Interior Design
1715 Magnavox Way 930 North Meridian
Fort Wayne, IN 46804 Indianapolis, IN 46204
260.432.9337 1 317.917.1190
mxvri.msktd.com
PE10708732
STATE a
CD
oT
EN
N
^,
W
co
�
O
}r
p
(n
^
W
O3
0.
4-1
�l^'`J
^L^,
r}n1
`+
/
L'
\
LU
U)
/
0
/�
.,SJ
0
z
�r
lwilmom}1�',
Q
n ,CD
(o
0.
CD
U)
//��
VJ
PROJECT NO.
DATE
7335
05-07-19
REV.
DATE
SET DESCRIPTION
SHEET TITLE
Plumbing Schedules
and
Details
DATE: V//L)U/-IU
SHEET NUMBER
P6-1 B