HomeMy WebLinkAboutTLR-016 ENERGYIECC 2009 Performance Compliance Property 14368 TRAHAN DR CARMEL, IN 46074 Model: ROOKWOOD(CA) Community: TALLYNS RIDGE 16 TRL016 (AS DESIGNED) TALLYNS RIDGE 16 Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,743 5254 $379 $2,376 $1,515 $0 $3,892 Requirements C-M, Energy Solutions As Designed S1,700 S240 S380 $2,319 S1,515 so $3,835 C4405.3 Performance-based compliance passes by 2.4% R402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 2.4%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 4/22119 at 8:44 AM Ekotrope RATER - Version 3.1.0.2155 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 74368 TRAHAN DR �J 15—P P CARMEL, IN 46074 Builder: FISCHER HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-11 Framed Floor N/A Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-6.0, Return R-6.0 Duct Leakage to Outside 155.0 CFM @ 25Pa Total Duct Leakage 248.0 CFM @ 25Pa Heating Furnace • Natural Gas • 96.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 4122119 at 8:44 AM Ekotrope RATER - Version 3.1.0.2155 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 14368 TRAHAN DR TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Model: ROOKWOOD(CA) Community: TALLYNS RIDGE 16 Builder FISCHER HOMES TRL016 (AS DESIGNED) TALLYNS RIDGE 16 General Building Information Conditioned Area (sq ft) 6,316 Conditioned Volume (cubic ft) 66,844 Insulated Shell Area (sq ft) 11,446 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (3,158 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 208, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 62, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (1,872 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I [ Name: CONDIGAR (558 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Energy Code Inspection Checklist Property 14368 TRAHAN DR CARMEL, IN 46074 Model: ROOKWOOD(CA) Community: TALLYNS RIDGE 16 TRL016 (AS DESIGNED) TALLYNS RIDGE 16 Roof Name: CONDIAMB (208 s.f.) R: 11.691 Name: CONDIGAR (62 s.f.) R: 11.691 Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Name: MAIN (3,158 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GAR (18 s.f.) U: 0.182 Glazing inspection Status Results are projected 11 Name: FRONT (100.02 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST El Name: BACK (186 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST Name: GD (72 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST E] Name: RIGHT SIDE (10 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH E] Name: LEFT SIDE (34 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present C-M, Energy Solutions 2 Energy Code Inspection Checklist Property 14368 TRAHAN DR CARMEL, IN 46074 Model: ROOKWOOD(CA) Community: TALLYNS RIDGE 16 TRL016 (AS DESIGNED) TALLYNS RIDGE 16 Mechanical Equipment Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Inspection Status Results are projected SYSTEM 1 HEATING • Natural Gas • 50% Heating Load @ 96.1 AFUE SYSTEM 2 HEATING • Natural Gas • 50% Heating Load @ 96.1 AFUE E] SYSTEM 1 COOLING • Electric • 50% Cooling Load @ 13 SEER E] SYSTEM 2 COOLING • Electric • 50% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4,737 CFM50 (5.00 AC H50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 Entirely within conditioned space Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 155.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 248.0 CFM @ 25Pa Duct System 2 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 155.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 248.0 CFM @ 25Pa C-M, Energy Solutions 3 Energy Code Inspection Checklist Property 14368 TRAHAN DR CARMEL, IN 46074 Model: ROOKWOOD(CA) Community: TALLYNS RIDGE 16 TRL016 (AS DESIGNED) TALLYNS RIDGE 16 Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes MECH VENT TO PASS ON FRONT 4 Building Summary Property Organization Inspection Status 14368 TRAHAN DR TSI Energy Solutions Results are projected CARMEL, IN 46074 Devin Sielschott Model: ROOKWOOD(CA) Community: TALLYNS RIDGE 16 Builder FISCHER HOMES TRL016 [AS DESIGNED] TALLYNS RIDGE 16 Genera?Building Information Number Of Bedrooms 4 Number Of Floors 1 Conditioned Floor Area [sq_ ft.] 6;316 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 56;844 Total Units in Building 1 Residence Type Single family detached Floor Number Model ROOKWOO❑(CA) Community TALLYNS RIDGE 16 Climate Zone 5A C-M, Energy Solutions Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4Pt 1 8 208 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4Pt 1 8 62 Exposed Exterior Conditioned Space w' Basement Wall Literary List Name Feet From Wall Top To Insulation Feet From Wall Top To Insulation Is Fully Insulated Effective Insulation R -value Top Bottom R-11 Draped, Oft 0 4 No 11.00 Slab BSMT Uninsulated 270 Below Grade 0 0 3,158.0 sq. ft. Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective 11-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame/ Other No 0 0 0 No 1).00 1 Building Summary Property 14368 TRAHAN DR CARMEL, IN 46074 Model: ROOKVVOOD[CA] Community: TALLYNS RIDGE 16 TRL016 [AS DESIGNED] TALLYNS RIDGE 16 Framed Floor Framed Floor Library List Organization TSI Energy Solutions Devin Sielschott Builder FISCHER HOMES Inspection Status Results are projected C-M, Energy Solutions Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-15, OSB 208.0 sq. ft. Exposed Exterior CONDIGAR G1 R-15, OSB 62.0 s9. ft. Unconditioned, attached garage Rim Joist Library List Name Effective Insulation R -value G1 R-15, OSB 11.691 CONDIAMB C O N DIGAR G1 R-15 BATT, T -PLY Medium 1.872.0 sq. fl. Exposed Exterior G1 R-15 Gar Walls Medium 558.0 sq. fl. Unconditioned, attached garage Building Summary Property Organization Inspection Status C-MEnergy Solutions 14368 TRAHAN DR TSI Energy Solutions Results are projected CARMEL, IN 46074 Devin Sielschott Model: ROOKWOOD[CA] Community: TALLYNS RIDGE 16 Builder FISCHER HOMES TRL016 [AS DESIGNED] TALLYNS RIDGE 16 Wall -library List Name Effective R -value G1 R-15 BATT, T -PLY 12.842 G1 R-15 Gar Walls 11.972 Glazing Name Library Type Wall -3 Assignment Basement Wall Overhang Assignment Depth Overhang Pt Top To Overhang Pt To Bottom Orientation Surface Area BACK U-.31, SHGG28 CONDIAMB 0 0 0 West 186.0 sq. ft. FRONT U-.31, SHGG28 CONDIAMB 0 0 0 East 100.0 sq. ft. GD U-31, SHGG28 CONDIAMB 0 0 ❑ West 72.0 sq. ft LEFT SIDE U-31, SHGG28 CONDIAMB 0 0 ❑ South 34.0 sq. fL RIGHT SIDE U-31, SHGG28 CONDIAMB 0 0 ❑ North 10.0 sq. fL Glazing Library List Name Shg c U factor U-.31, SHGC-28 028 0.310 Skylight None Present Skylight Library List None Present Building Summary Property Organization 14368 TRAHAN DR TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Model: ROOKWOOD[CA] Community: TALLYNS RIDGE 16 Builder FISCHER HOMES TRL016 [AS DESIGNED] TALLYNS RIDGE 16 Surface Area Location Opaque Door Name Library Type WallAssignmen: FRONT Steel Door CONDIAMB GAR Steel Door CONDIGAR Assign ment Opaque Door Library List Name Effective LI -factor 0.182 C-M Energy Solutions Inspection Status Results are projected 0.9 0.75 Medium 20.0 sq- ft Exposed Exterior 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area P.f.] Tiles Location F•,9AIN R-38 Blown, GR1 3,158 No Medium 3,158-0 sq. R Attic Roof Insulation Library List Name Has Radiant Barrier Effective R -value ?•8 3 :a l No 38268 Whole House Infiltratic Infiltration I5 ACH at 50 Pa Mechanical Ventilation Blower -door tested 4 M Solar Surface Color Surface Area Location Absorptance 0.9 0.75 Medium 20.0 sq- ft Exposed Exterior 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area P.f.] Tiles Location F•,9AIN R-38 Blown, GR1 3,158 No Medium 3,158-0 sq. R Attic Roof Insulation Library List Name Has Radiant Barrier Effective R -value ?•8 3 :a l No 38268 Whole House Infiltratic Infiltration I5 ACH at 50 Pa Mechanical Ventilation Blower -door tested 4 M Building Summary Property Organization 14368 TRAHAN DR TSI Energy Solutions CARMEL, IN 46074 Devin Sielschott Model: ROOKWOOD[CA] Community: TALLYNS RIDGE 16 Builder FISCHER HOMES TRL016 [AS DESIGNED] TALLYNS RIDGE 16 Lighting % Interior Fluorescent °% Interior LED Lighting % Exterior Fluorescent Lighting Lighting 0 C-M Energy Solutions Inspection Status Results are projected Fluorescent Lighting 0 C Onsite Generation mmmft� m None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load SYSTEM 1 COOLING GSX130361A o% 50% 0% SYSTEM 1 HEATING GMSS960603B 50% 0% 0% SYSTEM 2 COOLING GSX130361A 0% 50% 0% SYSTEM HEATING GMSS960603B 50% 0% 0% Water Heating ENT 50 100 0% 0% 100% Building Summary Property 14368 TRAHAN DR CARMEL, IN 46074 Model: ROOKVVOOD[CA] Community: TALLYNS RIDGE 16 TRL016 [AS DESIGNED] TALLYNS RIDGE 16 Equipment Type: Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency P Equipment Type: Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtulh] Use default EAE EAE [kWh] Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Builder FISCHER HOMES ENT 50 100 JJJJF"���� Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 GMSS960603BIl Equipment Type: GSX130361A Natural Gas Forced Air PSG (Single Speed) 96.1 AFUE 58 No 574 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 35 C-M, Energy Solutions Building Summary Property Organization Inspection Status 14368 TRAHAN DR TSI Energy Solutions Results are projected CARMEL, IN 46074 Devin Sielschott Model: ROOKWOOD[CA] 3158 Community: TALLYNS RIDGE 16 Builder Supply Duct R Value FISCHER HOMES TRL016 [AS DESIGNED] 6 TALLYNS RIDGE 16 852.66 Distribution System Distribution Type Forced Air Heating Equipment SYSTEM 1 HEATING Cooling Equipment SYSTEM 1 COOLING Sq. Feet Served 3158 # Return Grilles 2 Supply Duct R Value 6 Return Duct R Value 6 Supply Duct Area [sq. ft.] 852.66 Return Duct Area [sq. ft_] 315.8 Duct Leakage to Outdoors (CFM25) 155 Total Leakage 248 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 100 Percent Return Area 166 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area ❑ Percent Return Area ❑ Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ C-M, Energy Solutions 7 Building Summary Property C-MEnergy Solutions Organization Inspection Status 14368 TRAHAN DR TSI Energy Solutions Results are projected CARMEL, IN 46074 Devin Sielschott Model: ROOKWOOD[CA] Community: TALLYNS RIDGE 16 Builder FISCHER HOMES TRL016 [AS DESIGNED] TALLYNS RIDGE 16 Distribution System Distribution Type Forced Air Heating Equipment SYSTEM 2 HEATING Cooling Equipment SYSTEM 2 COOLING Sq. Feet Served 3158 # Return Grilles 2 Supply Duct R Value 25 Return Duct R Value 25 Supply Duct Area [sq. ft.] 852.66 Return Duct Area [sq. ft_] 315.8 Duct Leakage to Outdoors (CFM25) 155 Total Leakage 248 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 5 Percent Return Area 5 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 95 Percent Return Area 95 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ rCeiling Fan W Has Ceiling Fan No Cfm Per Watt 101 rA Building Summary Property 14368 TRAHAN DR CARMEL, IN 46074 Model: ROOKWOOD[CA] Community: TALLYNS RIDGE 16 TRL016 [AS DESIGNED] TALLYNS RIDGE 16 Water Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption PMCH VENT TO PASS ON FRONT Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Builder FISCHER HOMES Standard No 75 No No 10 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 0.331 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year C-M, Energy Solutions A