HomeMy WebLinkAboutTLR-016 ENERGYIECC 2009 Performance Compliance
Property
14368 TRAHAN DR
CARMEL, IN 46074
Model: ROOKWOOD(CA)
Community: TALLYNS RIDGE 16
TRL016 (AS DESIGNED)
TALLYNS RIDGE 16
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,743
5254
$379
$2,376
$1,515
$0
$3,892
Requirements
C-M,
Energy Solutions
As Designed
S1,700
S240
S380
$2,319
S1,515
so
$3,835
C4405.3 Performance-based compliance passes by 2.4%
R402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 2.4%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date:
4/22119 at 8:44 AM
Ekotrope RATER - Version 3.1.0.2155
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
74368 TRAHAN DR
�J 15—P P
CARMEL, IN 46074
Builder: FISCHER HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor N/A
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-6.0, Return R-6.0
Duct Leakage to Outside 155.0 CFM @ 25Pa
Total Duct Leakage 248.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 96.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 4122119 at 8:44 AM
Ekotrope RATER - Version 3.1.0.2155
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
14368 TRAHAN DR TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
Model: ROOKWOOD(CA)
Community: TALLYNS RIDGE 16 Builder
FISCHER HOMES
TRL016 (AS DESIGNED)
TALLYNS RIDGE 16
General Building Information
Conditioned Area (sq ft) 6,316
Conditioned Volume (cubic ft) 66,844
Insulated Shell Area (sq ft) 11,446
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT (3,158 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 208, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
E[ Name: CONDIGAR (Exterior Perimeter [ft]: 62, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (1,872 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
[ Name: CONDIGAR (558 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
Energy Code Inspection Checklist
Property
14368 TRAHAN DR
CARMEL, IN 46074
Model: ROOKWOOD(CA)
Community: TALLYNS RIDGE 16
TRL016 (AS DESIGNED)
TALLYNS RIDGE 16
Roof
Name: CONDIAMB (208 s.f.)
R: 11.691
Name: CONDIGAR (62 s.f.)
R: 11.691
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Name: MAIN (3,158 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GAR (18 s.f.)
U: 0.182
Glazing
inspection Status
Results are projected
11 Name: FRONT (100.02 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST
El Name: BACK (186 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
Name: GD (72 s.f.), U:0.310, SHGC: 0.28, Orientation: WEST
E] Name: RIGHT SIDE (10 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH
E] Name: LEFT SIDE (34 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property
14368 TRAHAN DR
CARMEL, IN 46074
Model: ROOKWOOD(CA)
Community: TALLYNS RIDGE 16
TRL016 (AS DESIGNED)
TALLYNS RIDGE 16
Mechanical Equipment
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Inspection Status
Results are projected
SYSTEM 1 HEATING • Natural Gas • 50% Heating Load @ 96.1 AFUE
SYSTEM 2 HEATING • Natural Gas • 50% Heating Load @ 96.1 AFUE
E] SYSTEM 1 COOLING • Electric • 50% Cooling Load @ 13 SEER
E] SYSTEM 2 COOLING • Electric • 50% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 4,737 CFM50 (5.00 AC H50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
Entirely within conditioned space
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 155.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 248.0 CFM @ 25Pa
Duct System 2
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 155.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 248.0 CFM @ 25Pa
C-M,
Energy Solutions
3
Energy Code Inspection Checklist
Property
14368 TRAHAN DR
CARMEL, IN 46074
Model: ROOKWOOD(CA)
Community: TALLYNS RIDGE 16
TRL016 (AS DESIGNED)
TALLYNS RIDGE 16
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
MECH VENT TO PASS ON FRONT
4
Building Summary
Property
Organization Inspection Status
14368 TRAHAN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46074
Devin Sielschott
Model: ROOKWOOD(CA)
Community: TALLYNS RIDGE 16
Builder
FISCHER HOMES
TRL016 [AS DESIGNED]
TALLYNS RIDGE 16
Genera?Building Information
Number Of Bedrooms
4
Number Of Floors
1
Conditioned Floor Area [sq_ ft.]
6;316
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu. ft.]
56;844
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
ROOKWOO❑(CA)
Community
TALLYNS RIDGE 16
Climate Zone
5A
C-M,
Energy Solutions
Basement Wall
Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing
CONDIAMB R-11 Draped, 4Pt 1 8 208 Exposed Exterior Conditioned Space
CONDIGAR R-11 Draped, 4Pt 1 8 62 Exposed Exterior Conditioned Space
w'
Basement Wall Literary List
Name Feet From Wall Top To Insulation Feet From Wall Top To Insulation Is Fully Insulated Effective Insulation R -value
Top Bottom
R-11 Draped, Oft 0 4 No 11.00
Slab
BSMT Uninsulated 270 Below Grade 0 0 3,158.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library Lis
Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective 11-value
Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
Uninsulated Wood Frame/ Other No 0 0 0 No 1).00
1
Building Summary
Property
14368 TRAHAN DR
CARMEL, IN 46074
Model: ROOKVVOOD[CA]
Community: TALLYNS RIDGE 16
TRL016 [AS DESIGNED]
TALLYNS RIDGE 16
Framed Floor
Framed Floor Library List
Organization
TSI Energy Solutions
Devin Sielschott
Builder
FISCHER HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Rim Joist
Name Library Type Surface Area Location
CONDIAMB G1 R-15, OSB 208.0 sq. ft. Exposed Exterior
CONDIGAR G1 R-15, OSB 62.0 s9. ft. Unconditioned, attached garage
Rim Joist Library List
Name Effective Insulation R -value
G1 R-15, OSB 11.691
CONDIAMB
C O N DIGAR
G1 R-15 BATT, T -PLY Medium 1.872.0 sq. fl. Exposed Exterior
G1 R-15 Gar Walls Medium 558.0 sq. fl. Unconditioned, attached garage
Building Summary
Property
Organization
Inspection Status
C-MEnergy
Solutions
14368 TRAHAN DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46074
Devin Sielschott
Model: ROOKWOOD[CA]
Community: TALLYNS RIDGE 16
Builder
FISCHER HOMES
TRL016 [AS DESIGNED]
TALLYNS RIDGE 16
Wall -library List
Name
Effective R -value
G1 R-15 BATT, T -PLY
12.842
G1 R-15 Gar Walls
11.972
Glazing
Name Library Type Wall
-3
Assignment Basement Wall Overhang
Assignment
Depth Overhang Pt
Top
To Overhang Pt To
Bottom
Orientation
Surface Area
BACK U-.31, SHGG28
CONDIAMB
0
0 0
West
186.0 sq. ft.
FRONT U-.31, SHGG28
CONDIAMB
0
0 0
East
100.0 sq. ft.
GD U-31, SHGG28
CONDIAMB
0
0 ❑
West
72.0 sq. ft
LEFT SIDE U-31, SHGG28
CONDIAMB
0
0 ❑
South
34.0 sq. fL
RIGHT SIDE U-31, SHGG28
CONDIAMB
0
0 ❑
North
10.0 sq. fL
Glazing Library List
Name
Shg c
U factor
U-.31, SHGC-28
028
0.310
Skylight
None Present
Skylight Library List
None Present
Building Summary
Property Organization
14368 TRAHAN DR TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
Model: ROOKWOOD[CA]
Community: TALLYNS RIDGE 16 Builder
FISCHER HOMES
TRL016 [AS DESIGNED]
TALLYNS RIDGE 16
Surface Area Location
Opaque Door
Name
Library Type WallAssignmen:
FRONT
Steel Door CONDIAMB
GAR
Steel Door CONDIGAR
Assign ment
Opaque Door Library List
Name Effective LI -factor
0.182
C-M
Energy Solutions
Inspection Status
Results are projected
0.9 0.75 Medium 20.0 sq- ft Exposed Exterior
0.9 0.75 Medium 18.0 sq- ft Exposed Exterior
Roof Insulation i
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area
P.f.] Tiles
Location
F•,9AIN R-38 Blown, GR1 3,158 No Medium 3,158-0 sq. R Attic
Roof Insulation Library List
Name Has Radiant Barrier Effective R -value
?•8 3 :a l No 38268
Whole House Infiltratic
Infiltration
I5 ACH at 50 Pa
Mechanical Ventilation
Blower -door tested 4
M
Solar Surface Color
Surface Area Location
Absorptance
0.9 0.75 Medium 20.0 sq- ft Exposed Exterior
0.9 0.75 Medium 18.0 sq- ft Exposed Exterior
Roof Insulation i
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area
P.f.] Tiles
Location
F•,9AIN R-38 Blown, GR1 3,158 No Medium 3,158-0 sq. R Attic
Roof Insulation Library List
Name Has Radiant Barrier Effective R -value
?•8 3 :a l No 38268
Whole House Infiltratic
Infiltration
I5 ACH at 50 Pa
Mechanical Ventilation
Blower -door tested 4
M
Building Summary
Property Organization
14368 TRAHAN DR TSI Energy Solutions
CARMEL, IN 46074 Devin Sielschott
Model: ROOKWOOD[CA]
Community: TALLYNS RIDGE 16 Builder
FISCHER HOMES
TRL016 [AS DESIGNED]
TALLYNS RIDGE 16
Lighting
% Interior Fluorescent °% Interior LED Lighting % Exterior Fluorescent
Lighting Lighting
0
C-M
Energy Solutions
Inspection Status
Results are projected
Fluorescent
Lighting
0 C
Onsite Generation mmmft� m
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name
Library Type
Heating Percent Load
Cooling Percent Load
Hot Water Percent Load
SYSTEM 1 COOLING
GSX130361A
o%
50%
0%
SYSTEM 1 HEATING
GMSS960603B
50%
0%
0%
SYSTEM 2 COOLING
GSX130361A
0%
50%
0%
SYSTEM HEATING
GMSS960603B
50%
0%
0%
Water Heating
ENT 50 100
0%
0%
100%
Building Summary
Property
14368 TRAHAN DR
CARMEL, IN 46074
Model: ROOKVVOOD[CA]
Community: TALLYNS RIDGE 16
TRL016 [AS DESIGNED]
TALLYNS RIDGE 16
Equipment Type:
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
P
Equipment Type:
Fuel Type
Distribution Type
Motor Type
Heating Efficiency
Heating Capacity [kBtulh]
Use default EAE
EAE [kWh]
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
FISCHER HOMES
ENT 50 100 JJJJF"����
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
GMSS960603BIl
Equipment Type: GSX130361A
Natural Gas
Forced Air
PSG (Single Speed)
96.1 AFUE
58
No
574
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 35
C-M,
Energy Solutions
Building Summary
Property
Organization Inspection Status
14368 TRAHAN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46074
Devin Sielschott
Model: ROOKWOOD[CA]
3158
Community: TALLYNS RIDGE 16
Builder
Supply Duct R Value
FISCHER HOMES
TRL016 [AS DESIGNED]
6
TALLYNS RIDGE 16
852.66
Distribution System
Distribution Type
Forced Air
Heating Equipment
SYSTEM 1 HEATING
Cooling Equipment
SYSTEM 1 COOLING
Sq. Feet Served
3158
# Return Grilles
2
Supply Duct R Value
6
Return Duct R Value
6
Supply Duct Area [sq. ft.]
852.66
Return Duct Area [sq. ft_]
315.8
Duct Leakage to Outdoors (CFM25)
155
Total Leakage
248
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
100
Percent Return Area
166
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
❑
Percent Return Area
❑
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
C-M,
Energy Solutions
7
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
14368 TRAHAN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46074
Devin Sielschott
Model: ROOKWOOD[CA]
Community: TALLYNS RIDGE 16
Builder
FISCHER HOMES
TRL016 [AS DESIGNED]
TALLYNS RIDGE 16
Distribution System
Distribution Type
Forced Air
Heating Equipment
SYSTEM 2 HEATING
Cooling Equipment
SYSTEM 2 COOLING
Sq. Feet Served
3158
# Return Grilles
2
Supply Duct R Value
25
Return Duct R Value
25
Supply Duct Area [sq. ft.]
852.66
Return Duct Area [sq. ft_]
315.8
Duct Leakage to Outdoors (CFM25)
155
Total Leakage
248
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
5
Percent Return Area
5
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
95
Percent Return Area
95
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rCeiling Fan W
Has Ceiling Fan No
Cfm Per Watt 101
rA
Building Summary
Property
14368 TRAHAN DR
CARMEL, IN 46074
Model: ROOKWOOD[CA]
Community: TALLYNS RIDGE 16
TRL016 [AS DESIGNED]
TALLYNS RIDGE 16
Water Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
PMCH VENT TO PASS ON FRONT
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
FISCHER HOMES
Standard
No
75
No
No
10
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
0.331
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
C-M,
Energy Solutions
A