Loading...
HomeMy WebLinkAboutA01202DOOR JAMB @ HORIZONTAL SIDINGSCALE:PLAN DETAILHORIZONTAL SIDING, TYPICALJ-CHANNEL TRIM, TYPICAL1x TRIM SURROUND - REFER TO ELEVATIONS LINE OF THRESHOLD BELOWENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'G.05 DOOR JAMB @ MASONRY VENEERSCALE: PLAN DETAILCAULK, CONTINUOUS LINE OF THRESHOLD BELOWLINE OF CONCRETE STEPBELOWENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'GNOTE:REFER TO TYPICAL WALL SECTIONS ANDGENERAL NOTES FOR BRICK TIEREQUIREMENTS. MASONRY VENEER, TYP.- BRICK SHOWN, STONE SIM.10DOOR HEAD WITH WOOD TRIM PANEL ABOVESCALE: 3" = 1'-0"08 SCALE:DOOR JAMB WITH WOOD TRIMPLAN DETAILCAULK, CONTINUOUS MASONRY VENEER, TYPICALLINE OF THRESHOLD BELOWLINE OF CONCRETE STOOPBELOW1x TRIM OVER P.T. 5/4 BACK-UP- REFER TO ELEVATIONS ENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'G11DOOR HEAD @ COVERED PORCH SCALE: ENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'G.BRICK BEYOND 2x CEILING RAFTER- REFER TO PLANS & SECTIONS06DOOR THRESHOLD @ BRICK VENEERSCALE: 8" THICK CAST-IN-PLACECONCRETE FOUNDATION WALL- UNLESS NOTED OTHERWISEON FOUNDATION PLANCAULK, CONTINUOUS DOOR JAMB BEYOND5/8x4 BLOCKING, TYPICALBRICK ROWLOCK SILL- SLOPE 1/4"- HOLD 1/4" BELOWTHRESHOLD, TYP.FINISH FLOORING SHOWN DASHED- REFER TO PLANSBRICK VENEER BEYOND'FLASH & SEAL' FLASHING6"1/2" FIBER EXPANSION BOARD,TYPICALCONC. HAUNCH BEYOND REFERTO FOUNDATION PLANSALUMINUM PAN- SET IN 3 BEADS OF CAULK12MASONRY VENEER w/ DECORATIVE SURROUNDSCALE: 8" THICK CAST-IN-PLACECONCRETE FOUNDATION WALL- UNLESS NOTED OTHERWISEON FOUNDATION PLAN1x6 TRIM OVER P.T. 1x BLOCKING- HOLD 1/4" BELOW THRESHOLD- HOLD 1/4" OFF T/ PORCH SLAB- w/ 45° BEVEL @ TOPFLASH & SEAL' FLASHING6"CAULK, CONTINUOUS SYNTHETIC DECORATIVE DOORSURROUND BEYOND-REFER TO ELEV'SDOOR THRESHOLDCONC. HAUNCH BEYOND REFERTO FOUNDATION PLANSCAULK, CONTINUOUS DOOR JAMB BEYONDFINISH FLOORING SHOWN DASHED- REFER TO PLANSBRICK VENEER BEYOND5/8x4 BLOCKING, TYPICALALUMINUM PAN- SET IN 3 BEADS OF CAULKDOOR HEAD @ HORIZONTAL SIDING01SCALE:HORIZONTAL SIDING, TYPICALSTRUCTURAL SHEATHING, TYPICALENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDOVERLAP STRUCTURAL SHEATHING 2"@ TOP PLATE TYPICAL1x TRIM, TYPICAL- REFER TO ELEVATIONS J-CHANNEL TRIM, TYPICALCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'G24" POLY FLASHING @ BANDBOARD, TYPICALBREAK MTL DRIP EDGE FLASH'G- NAIL & CAULK T/ FLASHING TO WALLSHEATHING, TYPICAL- EXTEND FLASH'G 1/2"± BEYONDOUTSIDE EDGE OF BRICK MOULD- SUPPLIED & INSTALLED BY DOORINSTALLER. 5/16" HARDIPANEL - SMOOTH FINISH,TYPICAL- HOLD 1/4" OFF BRICK MOULD1x TRIM, TYPICAL- HOLD TRIM 1/16" OFF BRICK MOULD- REFER TO ELEVATIONS FOR SIZES ANDPROFILESVENEER BEYOND- REFER TO ELEVATIONS, (BRICKSHOWN)BREAK MTL DRIP EDGE FLASH'G- NAIL & CAULK T/ FLASHING TO WALLSHEATHING, TYPICAL- EXTEND FLASH'G 1/2"± BEYONDOUTSIDE EDGE OF BRICK MOULD- SUPPLIED & INSTALLED BY DOORINSTALLERENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'G1x TRIM, TYPICAL- w/ 30° BEVEL @ TOP EDGE- HOLD TRIM 1/16" OFF BRICK MOULD- REFER TO ELEVATIONS FOR SIZES ANDPROFILESPVC MOULDING, TYPICAL- REFER TO ELEVATIONS FOR SIZE ANDLOCATION3" = 1'-0" 3" = 1'-0"3" = 1'-0"3" = 1'-0"3" = 1'-0"3" = 1'-0"3" = 1'-0"03DOOR THRESHOLD @ SIDING / CULTURED STONESCALE: 3" = 1'-0"8" THICK CAST-IN-PLACECONCRETE FOUNDATION WALL- UNLESS NOTED OTHERWISEON FOUNDATION PLANCAULK, CONTINUOUS DOOR JAMB BEYOND1x6 TRIM, TYPICAL- HOLD 14" BELOW THRESHOLD- HOLD1 4" OFF T/ PORCH SLABFINISH FLOORING SHOWN DASHED- REFER TO PLANS6"CAULK, CONTINUOUS CONC. HAUNCH BEYOND REFERTO FOUNDATION PLANSSTRUCTURAL SHEATHING- EXTEND SHEATHING TO12" BELOW T/ FDN WALL- w/ POLY EXTENDED 1"BELOW T/ FOUNDATION 5/8 x 4 BLOCKING, TYPICALALUMINUM PAN- SET IN 3 BEADS OF CAULK'FLASH & SEAL' FLASHINGMETAL DRIP- NAIL & TAPE TO SHEATHING- USE 1" ROOFING NAILS @ EA. STUD07SCALE: 3" = 1'-0"DOOR HEAD WITH WOOD TRIMSTEEL LINTEL, TYPICAL- RE: GENERAL NOTES FOR SIZE &BEARING REQUIREMENTS CAULK, CONTINUOUS 1x TRIM OVER P.T. 5/4 BACK-UP- REFER TO ELEVATIONS BREAK MTL DRIP EDGE FLASH'G- NAIL & CAULK T/ FLASHING TO WALLSHEATHING, TYPICAL- EXTEND FLASH'G 1/2"“ BEYONDOUTSIDE EDGE OF BRICK MOULD- SUPPLIED & INSTALLED BY DOORINSTALLERENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'GMASONRY VENEERMASONRY VENEER, TYP.- BRICK SHOWN, STONE SIM18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OFDOOR-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")04SCALE: 3" = 1'-0"DOOR HEAD @ MASONRY VENEERSTEEL LINTEL, TYPICAL- RE: GENERAL NOTES FOR SIZE &BEARING REQUIREMENTS ENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'GMASONRY VENEER, TYP.- BRICK SHOWN, STONE SIMNOTE:7/8"“ AIR SPACE @ BRICK VENEER,TYPICALGROUT SOLID W/ 15# FELT OROTHER APPROVEDWEATHER-RESISTANT MATERIAL@ STONE VENEER ONLY, TYPICAL09ARCHED DOOR HEAD @ BRICK VENEERSCALE: 3" = 1'-0"MASONRY VENEER, TYPICALCAULK, CONTINUOUS 1x TRIM OVER P.T. 5/4 BACK-UP- REFER TO ELEVATIONS ARCHED BRICK HEADER- BRICK SHOWN, STONE SIMBREAK MTL DRIP EDGE FLASH'G- NAIL & CAULK T/ FLASHING TO WALLSHEATHING, TYPICAL- EXTEND FLASH'G 1/2"“ BEYONDOUTSIDE EDGE OF BRICK MOULD- SUPPLIED & INSTALLED BY DOORINSTALLERENTRY DOOR WITH FACTORYAPPLIED BRICK MOULDCAULK CONTINUOUS OUTSIDE &BEHIND BRICK MOULD- INSTALL IN SUCH A MANNER SOAS TO PREVENT MOISTURE FROMENTERING THE TOP & SIDES OFTHE EXTERIOR DOOR OPN'G18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OFDOOR-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")BREAK MTL DRIP EDGE FLASH'G- NAIL & CAULK T/ FLASHING TO WALLSHEATHING, TYPICAL- EXTEND FLASH'G 1/2"“ BEYONDOUTSIDE EDGE OF BRICK MOULD- SUPPLIED & INSTALLED BY DOORINSTALLER18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OFDOOR-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")WILLIAM L.KAUF H OL Z ARCHITECTTALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:5/8/2019 9:52 AM# TLR010160000 JOE ARRUDA 14368 TRAHAN DRIVEROOKWOOD 77-450-ROOKWOOD COASTAL ACADIAN WITH BRICK & STONE CARMEL, IN16 03/2017 BA---- ----------------------------------------Grand Estates fieldspecchange@fischerhomes.comREVISED BY:---- ---- ----ARCH. SPECIALIST:SAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC----D1.1 05/16/19 Adam Schriner