Loading...
HomeMy WebLinkAboutA01403ROWLOCK WINDOW SILL @ MASONRY VENEERSCALE:1 1 2" NAIL @ EVERY OTHER NAILING HOLEIN WINDOW FLANGE- NAIL HEAD TO BE WIDER THAN HOLE INFLANGE1"1"±AT BRICK VENEERBRICK ROWLOCK SILL, TYP.- PULL BTM. 1"- SLOPE 1" TO PROVIDE POSITIVEDRAINAGE AWAY FROM WINDOW.14" BEAD OF 'SONOLASTIC NP-1'CAULK, CONT. BTWN FLANGE ANDSHEATHING- TYPICAL, ALL (4) SIDESHOLD T/SILL 1/4" ± FROMWINDOW FRAME- PROVIDE SEALANT, TYP.'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'G3" = 1'-0"18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OF SILL-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")09CAST STONE WINDOW SILL @ MASONRY VENEER SCALE: 3" = 1'-0" 1 1 2" NAIL @ EVERY OTHER NAILING HOLEIN WINDOW FLANGE.- NAIL HEAD TO BE WIDER THAN HOLE INFLANGE.14" BEAD OF 'SONOLASTIC NP-1'CAULK, CONT. BTWN FLANGE ANDSHEATHING- TYPICAL, ALL (4) SIDESHOLD T/SILL 1/4" ± FROMWINDOW FRAME- PROVIDE SEALANT, TYP.'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'G1"±CAST STONE SILL, TYP.- PULL BTM. 1"±18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OF SILL-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")3 1/2" @ BRICK5 1/2" @ STONE(FROM SHT'G)01SCALE:1 1 2" NAIL @ EVERY OTHER NAILING HOLE INWINDOW FLANGE- NAIL HEAD TO BE WIDER THAN HOLE IN FLANGEWINDOW HEAD @ FRIEZE BOARDMASONRY VENEER14" BEAD OF 'SONOLASTIC NP-1' CAULK,CONT. BTWN FLANGE AND SHEATHING- TYPICAL, ALL (4) SIDESCAULK, CONTINUOUS 'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'GMASONRY VENEER BEYOND- BRICK SHOWN, STONE SIM.2x4 BLOCKING @ 24"o.c.TYPICAL1x2 BLK'G @ TOP & BOTTOM,TYPICAL5/4" BLOCKING TYPICALHARDBOARD FRIEZE- TRIM TO MATCH WINDOW HEADER HEIGHTS- REFER TO ELEVATIONS FOR SIZES ANDPROFILES02WINDOW JAMB @ MASONRY VENEERSCALE:CAULK, CONTINUOUS PLAN DETAIL38"±NOTE:1"± AIR SPACE @ BRICK VENEER,TYPICALGROUT SOLID W/ 15# FELT OROTHER APPROVEDWEATHER-RESISTANT MATERIAL@ STONE VENEER ONLY, TYPICAL'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE.- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'G.NOTE:REFER TO TYPICAL WALL SECTIONS ANDGENERAL NOTES FOR BRICK TIEREQUIREMENTS. 10BRICK VENEER @ CAST STONE SILLSCALE: SECTION DETAILBRICK VENEER, TYPICALHORIZONTAL SIDING, TYPICALSIDING STARTER STRIP, TYP.RECOMMENDED OPTION05WINDOW JAMB w/ WD TRIM @ MASONRY VENEERSCALE: MASONRY VENEER, TYPICALPLAN DETAIL1x TRIM, OVER P.T. 1x BACK-UP- REFER TO ELEVATIONS FOR SIZESAND PROFILES'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'G11BRICK VENEER @ CAST STONE SILLSCALE: SECTION DETAILHORIZONTAL SIDING, TYPICALFINISH (UTILITY) TRIM, TYPICALSECOND OPTION12SCALE: THIRD OPTION BRICK VENEER @ CAST STONE SILLSECTION DETAILHORIZONTAL SIDING, TYPICALJ-CHANNEL TRIM, TYPICALw/ HOLES DRILLED @ 24"o.c. FORDRAINAGE58" HOLES DRILLED INJ-CHANNEL @ 24"o.c.- LOCATE IN BOTTOMFRONT OF J-CHANNEL1 1 2" NAIL @ EVERY OTHER NAILING HOLEIN WINDOW FLANGE- NAIL HEAD TO BE WIDER THAN HOLE INFLANGE14" BEAD OF 'SONOLASTIC NP-1'CAULK, CONT. BTWN FLANGE ANDSHEATHING- TYPICAL, ALL (4) SIDES1 1 2" NAIL @ EVERY OTHER NAILING HOLEIN WINDOW FLANGE- NAIL HEAD TO BE WIDER THAN HOLE INFLANGE14" BEAD OF 'SONOLASTIC NP-1'CAULK, CONT. BTWN FLANGE ANDSHEATHING- TYPICAL, ALL (4) SIDES3" = 1'-0"3" = 1'-0"3" = 1'-0" 3" = 1'-0"3" = 1'-0"3" = 1'-0"1x6, RIP TO FITCAULK, CONTINUOUS 2" x 3" METAL DRIP FLASHING, TYP.- w/ 1" HEM- NAIL & TAPE TO SHEATHING- USE 1" ROOFING NAILS @ EA. STUD1"±NOTE:HEM OF FLASHING MUST FASTEN ONEPIECE TO THE OTHER.1"±CAST STONE SILL, TYP.- PULL BTM. 1"±BRICK VENEER, TYPICAL2" x 3" METAL DRIP FLASHING, TYP.- w/ 1" HEM- NAIL & TAPE TO SHEATHING- USE 1" ROOFING NAILS @ EA. STUDNOTE:HEM OF FLASHING MUST FASTEN ONEPIECE TO THE OTHER.1"±CAST STONE SILL, TYP.- PULL BTM. 1"±BRICK VENEER, TYPICAL2" x 3" METAL DRIP FLASHING, TYP.- w/ 1" HEM- NAIL & TAPE TO SHEATHING- USE 1" ROOFING NAILS @ EA. STUD1"± NOTE:HEM OF FLASHING MUST FASTEN ONEPIECE TO THE OTHER.1"±4" CAST STONE SILL, TYP.- PULL BTM. 1"±NOTE:WINDOW NAILING FLANGE MUSTHAVE A CONTINUOUS LAP OF 1-1/8"OVER THE SHEATHING08 WINDOW HEAD @ MASONRY VENEERSCALE:CAULK, TYPICAL:- LEAVE 1/8" GAP @ EA. END OFWINDOW FOR AIRCIRCULATIOIN STEEL LINTEL, TYPICAL - RE: GENERAL NOTES FOR SIZE & BEARING REQUIREMENTS 14" BEAD OF 'SONOLASTIC NP-1'CAULK, CONT. BTWN FLANGE ANDSHEATHING- TYPICAL, ALL (4) SIDES'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'G.04WINDOW HEAD w/ WD TRIM @ MASONRY VENEERSCALE: BRICK VENEER, TYPICALSTEEL LINTEL, TYPICAL- RE: GENERAL NOTES FOR SIZE &BEARING REQUIREMENTS 1x TRIM, OVER P.T. 1x BACK-UP- REFER TO ELEVATIONS FOR SIZESAND PROFILES'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'G07ARCHED WINDOW HEAD @ MASONRY VENEER SCALE: MASONRY VENEER, TYPICALCAULK, CONTINUOUS 1x TRIM, OVER P.T. 1x BACK-UP- REFER TO ELEVATIONS FOR SIZESAND PROFILES-BRICK SHOWN, STONE SIM.'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'G3" = 1'-0"3" = 1'-0"3" = 1'-0"18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OF WINDOW-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")1 1 2" NAIL @ EVERY OTHER NAILING HOLEIN WINDOW FLANGE- NAIL HEAD TO BE WIDER THAN HOLE INFLANGE14" BEAD OF 'SONOLASTIC NP-1'CAULK, CONT. BTWN FLANGE ANDSHEATHING- TYPICAL, ALL (4) SIDES1 1 2" NAIL @ EVERY OTHER NAILING HOLEIN WINDOW FLANGE.- NAIL HEAD TO BE WIDER THAN HOLE INFLANGE.18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OFWINDOW-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OFWINDOW-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")1 1 2" NAIL @ EVERY OTHER NAILING HOLEIN WINDOW FLANGE- NAIL HEAD TO BE WIDER THAN HOLE INFLANGE14" BEAD OF 'SONOLASTIC NP-1'CAULK, CONT. BTWN FLANGE ANDSHEATHING- TYPICAL, ALL (4) SIDESBREAK MTL DRIP EDGE FLASH'G:- NAIL & CAULK T/ FLASHING TO WALLSHEATHING, TYPICAL- EXTEND FLASH'G 1/2"“ BEYONDOUTSIDE EDGE OF WINDOWBREAK MTL DRIP EDGE FLASH'G:- NAIL & CAULK T/ FLASHING TO WALLSHEATHING, TYPICAL- EXTEND FLASH'G 1/2"“ BEYONDOUTSIDE EDGE OF WINDOW06CAST STONE WINDOW HEAD @ MASONRYVENEERSCALE: 3" = 1'-0"1 1 2" NAIL @ EVERY OTHER NAILING HOLEIN WINDOW FLANGE- NAIL HEAD TO BE WIDER THAN HOLE INFLANGECAULK, TYPICAL- LEAVE 18" GAP @ EA. END OFWINDOW FOR AIRCIRCULATIOIN STEEL LINTEL, TYPICAL- RE: GENERAL NOTES FOR SIZE &BEARING REQUIREMENTS 14" BEAD OF 'SONOLASTIC NP-1'CAULK, CONT. BTWN FLANGE ANDSHEATHING- TYPICAL, ALL (4) SIDES'SONOLASTIC NP-1' CAULK OVER ALLNAIL HOLES AND OUTSIDE EDGE OFNAILING FLANGE- SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TOPREVENT MOISTURE FROM ENTERINGTHE TOP & SIDES OF THE EXTERIORWINDOW OPN'G18" MYLAR FLASHING-EXTEND 8" BEYOND EA. SIDE OFWINDOW-NAIL & CAULK T/ FLASH'G TOSHEATHING, TYP.BRICK WEEPHOLES, TYPICAL-ANGLE UP FROM BTM OF SOLDIER-2'-0" o.c. & AT EA. SIDE OF OPN'G-KEEP WEEPS TO MINIMUM (3/16")WILLIAM L.KAUF H OL Z ARCHITECTTALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:5/8/2019 9:52 AM# TLR010160000 JOE ARRUDA 14368 TRAHAN DRIVEROOKWOOD 77-450-ROOKWOOD COASTAL ACADIAN WITH BRICK & STONE CARMEL, IN16 03/2017 BA---- ----------------------------------------Grand Estates fieldspecchange@fischerhomes.comREVISED BY:---- ---- ----ARCH. SPECIALIST:SAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC----D1.3 05/16/19 Adam Schriner