Loading...
HomeMy WebLinkAboutA015 @ FIBER CEMENT BOARD PANEL SCALE: 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE. - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G. 06 3" = 1'-0" STRUCTURAL SHEATHING, TYPICAL FIBER CEMENT BOARD PANEL, TYPICAL 1x TRIM, TYPICAL - w/ 10° BEVEL @ TOP EDGE - w/ FIBER CEMENT BOARD PANEL BACK-UP - REFER TO ELEVATIONS FOR SIZES AND PROFILES @ FIBER CEMENT BOARD PANEL 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES SCALE:05 3" = 1'-0" STRUCTURAL SHEATHING, TYPICAL FIBER CEMENT BOARD PANEL, TYPICAL @ FIBER CEMENT BOARD PANEL 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 1x TRIM, TYPICAL - w/ FIBER CEMENT BOARD PANEL BACK-UP - REFER TO ELEVATIONS FOR SIZES AND PROFILES PLAN DETAIL - WINDOW JAMB w/ WOOD TRIM FIBER CEMENT BOARD PANEL, TYPICAL SCALE:08 3" = 1'-0" 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G @ FIBER CEMENT BOARD PANEL FIBER CEMENT BOARD PANEL, TYPICAL SCALE: 09 3" = 1'-0" 1x4 CORNER TRIM - OVER FIBER CEMENT BOARD PANEL FIBER CEMENT BOARD PANEL - EXTEND TO CORNER FRONT ELEVATION SCALE: w/ FIBER CEMENT BOARD PANEL 3" = 1'-0" PLAN DETAIL - 1x4 TRIM @ CORNER SECTION - WINDOW SILL w/ WOOD TRIM SECTION - WINDOW HEAD w/ SLOPED WOOD TRIM SECTION - WINDOW HEAD w/ WOOD TRIM @ GABLE END w/ LAPPED 1x8 RAKE BOARDS SECTION - FIBER CEMENT BOARD PANEL 07 SCALE: 3" = 1'-0" 1x8 RAKE BOARD - w/ 1x6 BACK-UP 1x8 FRIEZE BOARD - w/ FIBER CEMENT BOARD PANEL BACK-UP FIBER CEMENT BOARD PANEL, TYPICAL STRUCTURAL SHEATHING (STRUCTURAL & WATER REPELLENT) -GABLE SHT'G TO OVERLAP WALL SHT'G 2" MINIMUM.18"MAX.@ VERTICAL SEAM - GABLE END SCALE: SECTION - FIBER CEMENT BOARD PANEL 6" = 1'-0" - 2x4 FLATS @ 16" o.c. GABLE END TRUSS 1x BATTEN - REFER TO ELEVATIONS FOR SIZES AND PROFILES NOTE: ALWAYS PROVIDE STUD DIRECTLY BEHIND BATTEN / BUTT JOINT 18"MAX.@ VERTICAL SEAM SCALE: SECTION - FIBER CEMENT BOARD PANEL 6" = 1'-0" FRAME WALL @ 16" o.c. 1x BATTEN - REFER TO ELEVATIONS FOR SIZES AND PROFILES FIBER CEMENT BOARD PANEL, TYPICAL - MAX. 18" GAP @ SEAMS NAILING PATTERN NOTE: 2" x 6d GALVANIZED NAILS TO BE 6" o.c. ON PERIMETER and 12" o.c. IN THE FIELD - KEEP FASTENERS 2" AWAY FROM CORNERS & 38" MIN. FROM EDGE OF PANEL 'H' STRIP CONNECTOR FIBER CEMENT BOARD PANEL, TYPICAL FRAME WALL @ 16" o.c. 6" = 1'-0" SECTION - FIBER CEMENT BOARD PANEL SCALE: @ VERTICAL SEAM 12 01 02 03 18" STRUCTURAL SHEATHING 18" STRUCTURAL SHEATHING 18" STRUCTURAL SHEATHING FIBER CEMENT BOARD PANEL, TYPICAL - MAX. 18" GAP @ SEAMS 1x TRIM, TYPICAL - w/ 10° BEVEL @ TOP EDGE - w/ FIBER CEMENT BOARD PANEL BACK-UP - REFER TO ELEVATIONS FOR SIZES AND PROFILES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1x TRIM, TYPICAL - w/ 10° BEVEL @ TOP EDGE - w/ FIBER CEMENT BOARD PANEL BACK-UP - REFER TO ELEVATIONS FOR SIZES AND PROFILES BREAK MTL DRIP EDGE FLASH'G - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"“ BEYOND OUTSIDE EDGE OF WINDOW 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE BREAK MTL DRIP EDGE FLASH'G - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"“ BEYOND OUTSIDE EDGE OF WINDOW APPROVED ANCHORS @ 3"o.c., TYPICAL APPROVED FASTENER @ 3"o.c., TYPICAL STRUCTURAL SHEATHING, TYPICAL 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE NOTE: WINDOW NAILING FLANGE MUST HAVE A CONTINUOUS LAP OF 1-1/8" OVER THE SHEATHING, TYP. 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G HARDBOARD FRIEZE - TRIM TO MATCH WINDOW HEADER HEIGHTS - REFER TO ELEVATIONS FOR SIZES AND PROFILES - w/ FIBER CEMENT BOARD PANEL BACK-UP w/ FIBER CEMENT BOARD PANEL SCALE: 04 3" = 1'-0" SECTION - WINDOW HEAD @ FRIEZE BOARD @ BAND BOARD TRIM w/ SIDING BELOW PLAN DETAIL - FIBER CEMENT BOARD PANEL SCALE:11 3" = 1'-0" @ BAND BOARD TRIM w/ TRIM BELOW SECTION - FIBER CEMENT BOARD PANEL 10 SCALE: 3" = 1'-0" 1x TRIM BOARD - REFER TO ELEVATIONS FOR SIZES AND PROFILES - w/ FIBER CEMENT BOARD PANEL BACK-UP FIBER CEMENT BOARD PANEL, TYPICAL - HOLD OFF T/ TRIM 14" METAL DRIP FLASHING - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD 14"1x TRIM BOARD - REFER TO ELEVATIONS FOR SIZES AND PROFILES FIBER CEMENT BOARD PANEL, TYPICAL - HOLD OFF T/ TRIM 14" METAL DRIP FLASHING - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD 14" HORIZONTAL SIDING, TYPICAL J-CHANNEL TRIM, TYPICAL STRUCTURAL SHEATHING, TYPICAL FIBER CEMENT BOARD PANEL, TYPICAL 1x TRIM BOARD (SHOWN BEYOND) - REFER TO ELEVATIONS FOR SIZES AND PROFILES - w/ FIBER CEMENT BOARD PANEL BACK-UP STRUCTURAL SHEATHING, TYPICAL NAILING PATTERN NOTE: 2" x 6d GALVANIZED NAILS TO BE 6" o.c. ON PERIMETER and 12" o.c. IN THE FIELD - KEEP FASTENERS 2" AWAY FROM CORNERS & 38" MIN. FROM EDGE OF PANEL NAILING PATTERN NOTE: 2" x 6d GALVANIZED NAILS TO BE 6" o.c. ON PERIMETER and 12" o.c. IN THE FIELD - KEEP FASTENERS 2" AWAY FROM CORNERS & 38" MIN. FROM EDGE OF PANEL NOTE: ALWAYS PROVIDE STUD DIRECTLY BEHIND PANEL JOINT / 'H' STRIP CONNECTOR NOTE: ALWAYS PROVIDE STUD DIRECTLY BEHIND BATTEN / BUTT JOINT 1x2 SYNBOARD TRIM - EXTEND 1" BEYOND 1x BEVELED TRIM WILLIAM L.KAUF H OL Z ARCHITECTTALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:5/8/2019 9:52 AM# TLR010160000 JOE ARRUDA 14368 TRAHAN DRIVEROOKWOOD 77-450-ROOKWOOD COASTAL ACADIAN WITH BRICK & STONE CARMEL, IN16 03/2017 BA---- ----------------------------------------Grand Estates fieldspecchange@fischerhomes.comREVISED BY:---- ---- ----ARCH. SPECIALIST:SAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC----D1.4 05/16/19 Adam Schriner