HomeMy WebLinkAboutA018SCALE: 3/4" = 1'-0"812"APPROXIMATE LINE OF 3'-0" OVERDIG UNDISTURBED SOIL #4 RE-BAR @ 24" o.c. - SET BARS BELOW SLAB - EXTEND RE-BAR 2" INTO FOUNDATION WALL - PROVIDE TIGHT/FRICTION FIT OR EPOXY T/ FDN. WALL 6" 1'-4"212"6"thk. CONCRETE PATIO - w/12" x 6" FIBER EXPANSION JOINT MAT'L @ FDN. WALL T/ SUBFLOOR 2x12 FLOOR SYSTEM T/ FINISH GRADE FACE ALL EXPOSED SIDES OF PATIO - 2x12 FLOOR SYSTEM SECTION - PATIO @ FULL GRADE SCALE: 3/4" = 1'-0" - 2x10 FLOOR SYSTEM4" 812" 1'-4" 412" APPROXIMATE LINE OF 3'-0" OVERDIG UNDISTURBED SOIL #4 RE-BAR @ 24" o.c. - SET BARS BELOW SLAB - EXTEND RE-BAR 2" INTO FOUNDATION WALL - PROVIDE TIGHT/FRICTION FIT OR EPOXY 4"thk. CONCRETE PATIO - w/12" x 4" FIBER EXPANSION JOINT MAT'L @ FDN. WALL T/ SUBFLOOR T/ FDN. WALL 2x10 FLOOR SYSTEM T/ FINISH GRADE FACE ALL EXPOSED SIDES OF PATIO SECTION - PATIO @ FULL GRADE SCALE: @ GARAGE SERVICE DOOR 3/4" = 1'-0" T/ GARAGE SLAB 1"REFER TOPLANFOR DEPTHOF POUR-THRUSECTION - WEATHERLIP 1" WEATHERLIP @ SERVICE DOOR HOLD T/ GARAGE FDN. WALL DOWN FOR SLAB POUR-THRU - REFER TO PLAN FOR DEPTH 1" 01 02 03 04 05 06 07 BLOCKS ONLY AT SIDES OF OPENING - PROVIDE RECESSED NAILING SCALE: NOTE: CONCRETE DOOR HEADER DO NOT SET NAILING BLOCK INTO (2) #4 RE-BARS - w/ 2" MINIMUM COVER - w/ 2" MINIMUM COVER - EXTEND MIN 12" BEYOND OPENING (2) #4 RE-BARS 1014"or 22 14"8'-0"or 9'-0"2"3/4" = 1'-0"7'-134" 2" 2x6 @ PATIO DOOR SECTION - CONCRETE HEADER BLOCKS ONLY AT SIDES OF OPENING - PROVIDE RECESSED NAILING SCALE: NOTE: CONCRETE DOOR HEADER DO NOT SET NAILING BLOCK INTO (2) #4 RE-BARS - w/ 2" MINIMUM COVER - w/ 2" MINIMUM COVER - EXTEND MIN 12" BEYOND OPENING (2) #4 RE-BARS 1112"or 23 12"8'-0"or 9'-0"2" 3/4" = 1'-0" 7'-012" 2" 2x6 SECTION - CONCRETE HEADER @ SGD SCALE: SECTION - FROST FOOTING @ DOOR 3/4" = 1'-0" T/ SLAB 1"1" WEATHERLIP @ DOOR T/ SLAB 2'-0" DEPTH OF INSUL.312"NOTE: BASEMENT WALL INSULATION NOT SHOWN - TYPE VARIES PER PLAN - SEE NOTES ON FDN. PLAN FOR SPECIFIC INFO RIGID INSULATION - REFER TO GN SHEET FOR R-VALUE - 24" DEPTH - @ ALL AREAS WHERE GRADE COVERS 30" OR LESS OF THE FDN. WALL ABOVE THE T/ SLAB GRAVEL FILL - 4" MINIMUM 3 12"thk. CONCRETE SLAB 6-MIL VAPOR BARRIER FOUNDATION WALL THICKNESS VARIES - REFER TO PLAN FROST FOOTING - REFER TO GN FOR MIN. FROST FOOTING DEPTH FOOTING WIDTH VARIES PER PLANREFER TO GENERAL NOTES FORMINIMUM FROST FOOTING DEPTHSCALE: SECTION - FROST FOOTING T/ SLAB 2'-0" DEPTH OF INSUL.312" 3/4" = 1'-0" NOTE: BASEMENT WALL INSULATION NOT SHOWN - TYPE VARIES PER PLAN - SEE NOTES ON FDN. PLAN FOR SPECIFIC INFO RIGID INSULATION - REFER TO GN SHEET FOR R-VALUE - 24" DEPTH - @ ALL AREAS WHERE GRADE COVERS 30" OR LESS OF THE FDN. WALL ABOVE THE T/ SLAB 1" BEVELED INSULATION GRAVEL FILL - 4" MINIMUM 3 12"thk. CONCRETE SLAB 6-MIL VAPOR BARRIER FOUNDATION WALL THICKNESS VARIES - REFER TO PLAN FROST FOOTING - REFER TO GN FOR MIN. FROST FOOTING DEPTH FOOTING WIDTH VARIES PER PLANREFER TO GENERAL NOTES FORMINIMUM FROST FOOTING DEPTHWILLIAM L.KAUF H OL Z ARCHITECTTALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:5/8/2019 9:52 AM# TLR010160000 JOE ARRUDA 14368 TRAHAN DRIVEROOKWOOD 77-450-ROOKWOOD COASTAL ACADIAN WITH BRICK & STONE CARMEL, IN16 03/2017 BA---- ----------------------------------------Grand Estates fieldspecchange@fischerhomes.comREVISED BY:---- ---- ----ARCH. SPECIALIST:SAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC----D2.2 05/16/19 Adam Schriner