HomeMy WebLinkAboutA000.33.5:12
8:12
6:128:12
2030 FIXED
10121012
2030 FIXED
1012
8:12
8:12
24" LOUVERED SHUTTERS (U.N.O.) REF. PROD. SPEC.
STONE SILL- REF. PRODUCT SPECS.
14" LOUVERED SHUTTERS (U.N.O.) REF. PROD. SPEC.BKT5X5
STONE VENEER REF. PRODUCT SPECS.
1012
1012
8" ARCHED STONE HEADER -REF. PRODUCT SPECS.\pxql;8" ARCHED STONE HEADER -REF. PRODUCT SPECS.
STANDING SEAM METAL ROOF
14" LOUVERED SHUTTERS (U.N.O.) REF. PROD. SPEC.SHINGLES PER - REF. PRODUCT SPECS.
BKT5X5
\pxql;STONE VENEER REF. PRODUCT SPECS.
10121012
SIDING - REF. PRODUCT SPECS.
SIDING - REF. PRODUCT SPECS.
SHINGLE ROOF - REF. PRODUCT SPECS.
6:12
\A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H.
\A1;1'-1"O.H.\A1;1'-1"O.H.
\A1;27'-0"
\pxqc;LINE OF PITCH CHANGE\pxqc;LINE OF PITCH CHANGE
\A1;3'-6"
\A1;2'-4"
1x12 MATERIAL
1x8 MATERIAL
\A1;10'-6"\A1;10'-6"
12" RD TAPERED COL. ON 24"x24" STONE VENEER BASE1"x6" TRIM2X2 OVER 1X8 BOARD
\A1;4'-6" A.F.F.
MIN. 2 STEPS AT FRONT ENTRANCE W/ 18"-24" EXPOSED MASONRY PER COMM. SPECS.
STONE SILL -\PREF. PRODUCT SPECS.
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
WINDOW HEIGHT
1st FLR LINE
PLATE HEIGHT
TOP OF FOUNDATION \A1;3'-0"
SCALE:FRONT ELEVATION1/4" = 1'-0"-
SCALE:REAR ELEVATION1/8" = 1'-0"-
812812
WINDOW HEIGHT
1st FLR LINE
PLATE HEIGHT
STONE VENEER REF. PRODUCT SPECS.
SHINGLE ROOF - REF. PRODUCT SPECS.
5/4"x4" TRIM\A1;1'-1"O.H.\A1;1'-1"O.H.
812
5/4"x6" TRIM
\A1;4'-0"
\A1;2'-0"
\A1;4'-0"
TOP OF FOUNDATION\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
BRICK MASONRY WAINSCOT
612
SCALE:LEFT ELEVATION1/8" = 1'-0"-
BRICK MASONRY WAINSCOT
WINDOW HEIGHTPLATE HEIGHT
TOP OF FOUNDATION \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;8'-4{\H0.750000x;\S3#8;}"\A1;HDR. HGT. @ 4010
612
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
\A1;10'-0"
\A1;16'-0"
\A1;1'-0"\PTYP.\A1;8'-1{\H0.750000x;\S1#2;}"\A1;4'-11{\H0.750000x;\S1#4;}"
\A1;7'-0{\H0.75x;\S1#2;}"
\A1;16'-0"
\A1;10'-0"
\A1;1'-0"\PTYP.
SCALE:ROOF PLAN1/8" = 1'-0"-
ROOF AREA"A"3287 SQ. FT.
6:12
6:12
10:1210:128:12
10:1210:12
10:1210:128:12
8:12
3.5:12
8:1210:12
ELEVATION EC3M
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3287 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.38 5.48 5.08 49.73 12 0
AT EAVE 6.57 5.48 5.14 50.27 0 74.00
TOTAL (MIN)10.96 10.96 10.22 100.00
3
HIGH -
RIDGE VENT 4.38 5.48 5.75 52.81 0 0 46.00
AT EAVE 6.57 5.48 5.14 47.19 0 74.00
TOTAL (MIN)10.96 10.96 10.89 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
SCALE :1/4" = 1'-0"INTERIOR PORCH ELEVATION EC3M
SIDING - REF. PRODUCT SPECS.SIDING - REF. PRODUCT SPECS.SIDING - REF. PRODUCT SPECS.1"x6" TRIM 12" RD TAPERED COL. ON 24"x42" STONE VENEER BASE1"x6" TRIMSTONE WAINSCOT 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
SUZETTE SCHUETTE06/07/2013
GARAGE RIGHT
Croix
1993.301
LOT 05
04/25/2019
PLOTTED: April 30, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-EC3M.DWG
A3
EC3M-2FS.1Elevation EC3M - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule05/16/19
Adam Schriner