Loading...
HomeMy WebLinkAboutA01703 ROWLOCK WINDOW SILL @ MASONRY VENEER SCALE: 11 2" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1"1"±BRICK ROWLOCK SILL, TYP. - PULL BTM. 1" - SLOPE 1" TO PROVIDE POSITIVE DRAINAGE AWAY FROM WINDOW. 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES HOLD T/SILL 1/4" ± FROM WINDOW FRAME - PROVIDE SEALANT, TYP. 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 3" = 1'-0" 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF SILL -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") 09 CAST STONE WINDOW SILL @ MASONRY VENEER SCALE:3" = 1'-0" 1 12" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE. - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE. 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES HOLD T/SILL 1/4" ± FROM WINDOW FRAME - PROVIDE SEALANT, TYP. 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 1"± CAST STONE SILL, TYP. - PULL BTM. 1"± 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF SILL -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") 3 1/2" @ BRICK 5 1/2" @ STONE (FROM SHT'G) 01 SCALE: 11 2" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE WINDOW HEAD @ FRIEZE BOARD MASONRY VENEER 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES CAULK, CONTINUOUS 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G MASONRY VENEER BEYOND - BRICK SHOWN, STONE SIM. 2x4 BLOCKING @ 24"o.c. TYPICAL 1x2 BLK'G @ TOP & BOTTOM, TYPICAL 5/4" BLOCKING TYPICAL HARDBOARD FRIEZE - TRIM TO MATCH WINDOW HEADER HEIGHTS - REFER TO ELEVATIONS FOR SIZES AND PROFILES 02 WINDOW JAMB @ MASONRY VENEER SCALE: CAULK, CONTINUOUS PLAN DETAIL 38"±1"± AIR SPACE @ BRICK VENEER, TYPICAL GROUT SOLID W/ 15# FELT OR OTHER APPROVED WEATHER-RESISTANT MATERIAL @ STONE VENEER ONLY, TYPICAL 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE. - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G. REFER TO TYPICAL WALL SECTIONS AND GENERAL NOTES FOR BRICK TIE REQUIREMENTS. 10BRICK VENEER @ CAST STONE SILL SCALE: SECTION DETAIL BRICK VENEER, TYPICAL HORIZONTAL SIDING, TYPICAL SIDING STARTER STRIP, TYP. RECOMMENDED OPTION 05 WINDOW JAMB w/ WD TRIM @ MASONRY VENEER SCALE: MASONRY VENEER, TYPICAL PLAN DETAIL 1x TRIM, OVER P.T. 1x BACK-UP - REFER TO ELEVATIONS FOR SIZES AND PROFILES 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 11 BRICK VENEER @ CAST STONE SILL SCALE: SECTION DETAIL HORIZONTAL SIDING, TYPICAL FINISH (UTILITY) TRIM, TYPICAL SECOND OPTION 12SCALE: THIRD OPTION BRICK VENEER @ CAST STONE SILL SECTION DETAIL HORIZONTAL SIDING, TYPICAL J-CHANNEL TRIM, TYPICAL w/ HOLES DRILLED @ 24"o.c. FOR DRAINAGE 5 8" HOLES DRILLED IN J-CHANNEL @ 24"o.c. - LOCATE IN BOTTOM FRONT OF J-CHANNEL 11 2" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 11 2" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 3" = 1'-0" 1x6, RIP TO FIT CAULK, CONTINUOUS 2" x 3" METAL DRIP FLASHING, TYP. - w/ 1" HEM - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD 1"±NOTE: HEM OF FLASHING MUST FASTEN ONE PIECE TO THE OTHER. 1"± CAST STONE SILL, TYP. - PULL BTM. 1"± BRICK VENEER, TYPICAL 2" x 3" METAL DRIP FLASHING, TYP. - w/ 1" HEM - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD NOTE: HEM OF FLASHING MUST FASTEN ONE PIECE TO THE OTHER. 1"± CAST STONE SILL, TYP. - PULL BTM. 1"± BRICK VENEER, TYPICAL 2" x 3" METAL DRIP FLASHING, TYP. - w/ 1" HEM - NAIL & TAPE TO SHEATHING - USE 1" ROOFING NAILS @ EA. STUD 1"± NOTE: HEM OF FLASHING MUST FASTEN ONE PIECE TO THE OTHER. 1"± 4" CAST STONE SILL, TYP. - PULL BTM. 1"± WINDOW NAILING FLANGE MUST HAVE A CONTINUOUS LAP OF 1-1/8" OVER THE SHEATHING 08 WINDOW HEAD @ MASONRY VENEER SCALE: CAULK, TYPICAL: - LEAVE 1/8" GAP @ EA. END OF WINDOW FOR AIR CIRCULATIOIN STEEL LINTEL, TYPICAL - RE: GENERAL NOTES FOR SIZE & BEARING REQUIREMENTS 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G. 04 WINDOW HEAD w/ WD TRIM @ MASONRY VENEER SCALE: BRICK VENEER, TYPICAL STEEL LINTEL, TYPICAL - RE: GENERAL NOTES FOR SIZE & BEARING REQUIREMENTS 1x TRIM, OVER P.T. 1x BACK-UP - REFER TO ELEVATIONS FOR SIZES AND PROFILES 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 07 ARCHED WINDOW HEAD @ MASONRY VENEER SCALE: MASONRY VENEER, TYPICAL CAULK, CONTINUOUS 1x TRIM, OVER P.T. 1x BACK-UP - REFER TO ELEVATIONS FOR SIZES AND PROFILES -BRICK SHOWN, STONE SIM. 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 3" = 1'-0"3" = 1'-0" 3" = 1'-0" 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF WINDOW -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 112" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE. - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE. 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF WINDOW -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF WINDOW -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16") 11 2" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES BREAK MTL DRIP EDGE FLASH'G: - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"± BEYOND OUTSIDE EDGE OF WINDOW BREAK MTL DRIP EDGE FLASH'G: - NAIL & CAULK T/ FLASHING TO WALL SHEATHING, TYPICAL - EXTEND FLASH'G 1/2"± BEYOND OUTSIDE EDGE OF WINDOW 06 CAST STONE WINDOW HEAD @ MASONRY VENEER SCALE:3" = 1'-0" 1 1 2" NAIL @ EVERY OTHER NAILING HOLE IN WINDOW FLANGE - NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE CAULK, TYPICAL - LEAVE 1 8" GAP @ EA. END OF WINDOW FOR AIR CIRCULATIOIN STEEL LINTEL, TYPICAL - RE: GENERAL NOTES FOR SIZE & BEARING REQUIREMENTS 1 4" BEAD OF 'SONOLASTIC NP-1' CAULK, CONT. BTWN FLANGE AND SHEATHING - TYPICAL, ALL (4) SIDES 'SONOLASTIC NP-1' CAULK OVER ALL NAIL HOLES AND OUTSIDE EDGE OF NAILING FLANGE - SMOOTH w/ APPLICATOR - INSTALL IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE TOP & SIDES OF THE EXTERIOR WINDOW OPN'G 18" MYLAR FLASHING -EXTEND 8" BEYOND EA. SIDE OF WINDOW -NAIL & CAULK T/ FLASH'G TO SHEATHING, TYP. BRICK WEEPHOLES, TYPICAL -ANGLE UP FROM BTM OF SOLDIER -2'-0" o.c. & AT EA. SIDE OF OPN'G -KEEP WEEPS TO MINIMUM (3/16")OVERBROOK FARMS REASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: HOME TYPE:PLAN:5/10/2019 1:00 PM# LKHANNAA MAAMUUJAV3960 BEAR CREEK WAYMARSHALL 47-480-MARSHALL FRENCH MANOR WITH BRICK & STONECARMEL, IN91 05/2017 -------- ------------fieldspecchange@fischerhomes.com REVISED BY:---- ---- ----SAPPHIRE TRADE SUPPORT sapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC----05/31/19 William Hohlt