HomeMy WebLinkAboutA01703 ROWLOCK WINDOW SILL @ MASONRY VENEER
SCALE:
11 2" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
1"1"±BRICK ROWLOCK SILL, TYP.
- PULL BTM. 1"
- SLOPE 1" TO PROVIDE POSITIVE
DRAINAGE AWAY FROM WINDOW.
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
HOLD T/SILL 1/4" ± FROM
WINDOW FRAME
- PROVIDE SEALANT, TYP.
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
3" = 1'-0"
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF SILL
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")
09 CAST STONE WINDOW SILL @ MASONRY VENEER
SCALE:3" = 1'-0"
1 12" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE.
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE.
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
HOLD T/SILL 1/4" ± FROM
WINDOW FRAME
- PROVIDE SEALANT, TYP.
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
1"±
CAST STONE SILL, TYP.
- PULL BTM. 1"±
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF SILL
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")
3 1/2" @ BRICK
5 1/2" @ STONE
(FROM SHT'G)
01 SCALE:
11 2" NAIL @ EVERY OTHER NAILING HOLE IN
WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN FLANGE
WINDOW HEAD @ FRIEZE BOARD
MASONRY VENEER
1 4" BEAD OF 'SONOLASTIC NP-1' CAULK,
CONT. BTWN FLANGE AND SHEATHING
- TYPICAL, ALL (4) SIDES
CAULK, CONTINUOUS
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
MASONRY VENEER BEYOND
- BRICK SHOWN, STONE SIM.
2x4 BLOCKING @ 24"o.c.
TYPICAL
1x2 BLK'G @ TOP & BOTTOM,
TYPICAL
5/4" BLOCKING TYPICAL
HARDBOARD FRIEZE
- TRIM TO MATCH WINDOW HEADER HEIGHTS
- REFER TO ELEVATIONS FOR SIZES AND
PROFILES
02 WINDOW JAMB @ MASONRY VENEER
SCALE:
CAULK, CONTINUOUS
PLAN DETAIL 38"±1"± AIR SPACE @ BRICK VENEER,
TYPICAL
GROUT SOLID W/ 15# FELT OR
OTHER APPROVED
WEATHER-RESISTANT MATERIAL
@ STONE VENEER ONLY, TYPICAL
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE.
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G.
REFER TO TYPICAL WALL SECTIONS AND
GENERAL NOTES FOR BRICK TIE
REQUIREMENTS.
10BRICK VENEER @ CAST STONE SILL
SCALE:
SECTION DETAIL
BRICK VENEER, TYPICAL
HORIZONTAL SIDING, TYPICAL
SIDING STARTER STRIP, TYP.
RECOMMENDED OPTION
05 WINDOW JAMB w/ WD TRIM @ MASONRY VENEER
SCALE:
MASONRY VENEER, TYPICAL
PLAN DETAIL
1x TRIM, OVER P.T. 1x BACK-UP
- REFER TO ELEVATIONS FOR SIZES
AND PROFILES
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
11 BRICK VENEER @ CAST STONE SILL
SCALE:
SECTION DETAIL
HORIZONTAL SIDING, TYPICAL
FINISH (UTILITY) TRIM, TYPICAL
SECOND OPTION
12SCALE:
THIRD OPTION
BRICK VENEER @ CAST STONE SILL
SECTION DETAIL
HORIZONTAL SIDING, TYPICAL
J-CHANNEL TRIM, TYPICAL
w/ HOLES DRILLED @ 24"o.c. FOR
DRAINAGE
5 8" HOLES DRILLED IN
J-CHANNEL @ 24"o.c.
- LOCATE IN BOTTOM
FRONT OF J-CHANNEL
11 2" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
11 2" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
3" = 1'-0"
3" = 1'-0"
3" = 1'-0"
3" = 1'-0" 3" = 1'-0"
3" = 1'-0"
1x6, RIP TO FIT
CAULK, CONTINUOUS
2" x 3" METAL DRIP FLASHING, TYP.
- w/ 1" HEM
- NAIL & TAPE TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
1"±NOTE:
HEM OF FLASHING MUST FASTEN ONE
PIECE TO THE OTHER.
1"±
CAST STONE SILL, TYP.
- PULL BTM. 1"±
BRICK VENEER, TYPICAL
2" x 3" METAL DRIP FLASHING, TYP.
- w/ 1" HEM
- NAIL & TAPE TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
NOTE:
HEM OF FLASHING MUST FASTEN ONE
PIECE TO THE OTHER.
1"±
CAST STONE SILL, TYP.
- PULL BTM. 1"±
BRICK VENEER, TYPICAL
2" x 3" METAL DRIP FLASHING, TYP.
- w/ 1" HEM
- NAIL & TAPE TO SHEATHING
- USE 1" ROOFING NAILS @ EA. STUD
1"± NOTE:
HEM OF FLASHING MUST FASTEN ONE
PIECE TO THE OTHER.
1"±
4" CAST STONE SILL, TYP.
- PULL BTM. 1"±
WINDOW NAILING FLANGE MUST
HAVE A CONTINUOUS LAP OF 1-1/8"
OVER THE SHEATHING
08 WINDOW HEAD @ MASONRY VENEER
SCALE:
CAULK, TYPICAL:
- LEAVE 1/8" GAP @ EA. END OF
WINDOW FOR AIR
CIRCULATIOIN
STEEL LINTEL, TYPICAL
- RE: GENERAL NOTES FOR SIZE &
BEARING REQUIREMENTS
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G.
04 WINDOW HEAD w/ WD TRIM @ MASONRY VENEER
SCALE:
BRICK VENEER, TYPICAL
STEEL LINTEL, TYPICAL
- RE: GENERAL NOTES FOR SIZE &
BEARING REQUIREMENTS
1x TRIM, OVER P.T. 1x BACK-UP
- REFER TO ELEVATIONS FOR SIZES
AND PROFILES
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
07 ARCHED WINDOW HEAD @ MASONRY VENEER
SCALE:
MASONRY VENEER, TYPICAL
CAULK, CONTINUOUS
1x TRIM, OVER P.T. 1x BACK-UP
- REFER TO ELEVATIONS FOR SIZES
AND PROFILES
-BRICK SHOWN, STONE SIM.
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
3" = 1'-0"3" = 1'-0"
3" = 1'-0"
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF
WINDOW
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")
112" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
112" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE.
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE.
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF
WINDOW
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF
WINDOW
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")
11 2" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
BREAK MTL DRIP EDGE FLASH'G:
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2"± BEYOND
OUTSIDE EDGE OF WINDOW
BREAK MTL DRIP EDGE FLASH'G:
- NAIL & CAULK T/ FLASHING TO WALL
SHEATHING, TYPICAL
- EXTEND FLASH'G 1/2"± BEYOND
OUTSIDE EDGE OF WINDOW
06 CAST STONE WINDOW HEAD @ MASONRY VENEER
SCALE:3" = 1'-0"
1 1 2" NAIL @ EVERY OTHER NAILING HOLE
IN WINDOW FLANGE
- NAIL HEAD TO BE WIDER THAN HOLE IN
FLANGE
CAULK, TYPICAL
- LEAVE 1 8" GAP @ EA. END OF
WINDOW FOR AIR
CIRCULATIOIN
STEEL LINTEL, TYPICAL
- RE: GENERAL NOTES FOR SIZE &
BEARING REQUIREMENTS
1 4" BEAD OF 'SONOLASTIC NP-1'
CAULK, CONT. BTWN FLANGE AND
SHEATHING
- TYPICAL, ALL (4) SIDES
'SONOLASTIC NP-1' CAULK OVER ALL
NAIL HOLES AND OUTSIDE EDGE OF
NAILING FLANGE
- SMOOTH w/ APPLICATOR
- INSTALL IN SUCH A MANNER SO AS TO
PREVENT MOISTURE FROM ENTERING
THE TOP & SIDES OF THE EXTERIOR
WINDOW OPN'G
18" MYLAR FLASHING
-EXTEND 8" BEYOND EA. SIDE OF
WINDOW
-NAIL & CAULK T/ FLASH'G TO
SHEATHING, TYP.
BRICK WEEPHOLES, TYPICAL
-ANGLE UP FROM BTM OF SOLDIER
-2'-0" o.c. & AT EA. SIDE OF OPN'G
-KEEP WEEPS TO MINIMUM (3/16")OVERBROOK FARMS
REASON FOR PLOT: PLOT DATE: Job No.
Sheet No.INHOMESITE NO. MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED
FISCHER HOMES, Inc.JOB INFO: DATE: HOME TYPE:PLAN:5/10/2019 1:00 PM# LKHANNAA MAAMUUJAV3960 BEAR CREEK WAYMARSHALL
47-480-MARSHALL FRENCH MANOR WITH BRICK & STONECARMEL, IN91 05/2017
-------- ------------fieldspecchange@fischerhomes.com
REVISED BY:---- ---- ----SAPPHIRE TRADE SUPPORT
sapphiretradepartners@fischerhomes.com
Fischer Homes Indianapolis II, LLC----05/31/19
William Hohlt