Loading...
HomeMy WebLinkAboutE001HBHBREFER TO DETAIL SHEET D2.3 FOR DOVETAILS FOR SIDING TO GRADE NOTE: REFER TO DETAIL SHEET D2.0 FOR GARAGE SLAB REBAR REQUIREMENT NOTE: A FLR BRK C B UPDUPFURNACE LINE OF PATIO ABOVE 1'-0" - SAFETY COVER EGRESS WINDOW WELL - w/ DRAIN -HOLD T/ WINDOW 10" BELOW T/ FDN. WALL 4"5'-1134" TO BEARING STUDS3'-912"TO NOSING3'-1112"TO NOSINGPREF'D EJECTOR LOCATION PREF'D SUMP LOCATION 1'-0"VERTICAL CONTROL JOINT - SEE DTL. 01/D2.1 9'-83 4" TO ® PIER / FT'G.11'-1078"TO ® PIER / FT'G.11'-412"TO ® STEEL BEAM / COLUMNWATER SOFT. R.I. UNEXCAVATED BASEMENT 5'-0"8"1112" 8" x 18" C.I.P. CONCRETE FOOTINGS FD LINE OF PORCH ABOVE 2x4 LET-IN FOR SLAB SUPPORT #4 RE-BAR - STUBBED OUT & LOOPED ® 1'-8"4'-10"TO NOSING3'-7" 2'-0" 36" x 36" x 15" THICK C.I.P. CONCRETE COLUMN FT'G - HOLD T/ FT'G. DOWN 312" FROM T/ SLAB 4" Ø STEEL COLUMN 8"3'-11" TO ® STEELBEAM / COLUMN4"Ø STEEL COLUMN7'-712"TO ® FOOT'G36" x 36" x 15" THICK C.I.P. CONCRETE COLUMN FT'G - HOLD T/ FT'G. DOWN 312" FROM T/ SLAB4'-218"4 ' - 21 4"16'-034"TO ® STEEL BEAM15'-3" 11'-812"TO ® STEEL BEAMW8 x 18 STEEL BEAM8"8"8" 14'-312" TO ® STEEL COLUMN 8" 13'-312" TO ® FLOOR DRAIN 19'-11 4" TO ® FOOTING 20'-6" 12'-112" TO ® STEEL COLUMN 8" 17'-712" TO ® STEEL COLUMN 8" 18'-3" 24'-9" 8" C.I.P. CONCRETE FOUNDATION WALLS FURNACE WH HANDRAIL 412"512"4 1/2" X 5 1/2" BOX OUT 2x4 NOTCH SLOPED 3" FROM REAR TO FRONT FOR SLAB SUPPORT - SEE DTL. 04/D2.1 HOLD T/ GARAGE SLAB DOWN 1" FROM T/ FDN. & SLOPE TO O.H. DOOR 8"3"5'-534"412"1'-1112" 3" 5'-0" 3'-7"15'-514"TO ® STEEL BEAM / COLUMN5'-6"TO ® FLR. DRAIN9'-214"TO ® STEEL BEAM / COLUMNRADON PIPE - DETAIL 02/D2.1 13'-4" TO ® STEEL COLUMN 12'-712" TO ® STEEL COLUMN 4" Ø STEEL COLUMN 36" x 36" x 15" THICK C.I.P. CONCRETE COLUMN FT'G - HOLD T/ FT'G. DOWN 31 2" FROM T/ SLAB W8 x21 STEEL BEAM (3) 2x4 JACK STUDS FOR POINT LOAD BEARING ABOVE 24" x 24" x 12" THICK CONC. COLUMN FOOTING - HOLD T/ FT'G. DOWN 31 2" FROM T/ SLAB (2) 2x4 JACK STUDS FOR POINT LOAD BEARING ABOVE DETECTOR 110V SMOKE 4" x 8" x 81 8"d. BEAM POCKET 4" Ø STEEL COLUMN 42" x 42" x 18" THICK C.I.P. CONCRETE COLUMN FT'G - HOLD T/ FT'G. DOWN 31 2" FROM T/ SLAB W8 x18 STEEL BEAM W8 x28 STEEL BEAM 45" x 45" x 18" THICK C.I.P. CONCRETE COLUMN FT'G - HOLD T/ FT'G. DOWN 31 2" FROM T/ SLAB 4" Ø STEEL COLUMN 8" 8" 15'-934"TO ® STEEL BEAM / COLUMN8'-0" FOUNDATION 8"d. x 18"w. C.I.P CONCRETE FOOTING - SEE DTL. 04/D2.13'-534"TO BEARING STUDS9'-4"2'-912"13'-10" 2'-10" 6'-6" 2'-3" 25'-5" 11'-0" 9'-1012" 2'-3 12" 48'-7"2'-312" 3'-812"6'-0" 56'-212"62'-212"8'-312" 8'-312" 16'-7" 9'-95 8" 2'-1112" 14'-33 8" 2'-115 8" 3" 15'-6" 3"2'-312" 4'-712" 16'-0" 19'-5 58" 5'-2" 3'-778" 2'-1112" 8'-058"62'-212"2'-0" FOUNDATION DIAGONALS A B A 0" A 56'-2 1/2" B 56'-2 1/2" B 0" C 64'-10 15/16" C 47'-10 3/8" D 46'-5 9/32" D 75'-8 19/32"OVERBROOK FARMS REASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. MASTER BY: DATE: C DATE: 3940 OLYMPIC BLVDERLANGER, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: HOME TYPE:PLAN:5/10/2019 12:58 PM# LKHANNAA MAAMUUJAV3960 BEAR CREEK WAYMARSHALL 47-480-MARSHALL FRENCH MANOR WITH BRICK & STONECARMEL, IN91 05/2017 -------- ------------fieldspecchange@fischerhomes.com REVISED BY:---- ---- ----SAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC ----SCALE = 1'-0" FOUNDATION PLAN 1/4"01 FOUNDATION PLAN NOTE: 1. FOUNDATION WALLS SHADED AS TO BE SET AT T/ FDN ELEVATION PER PLOT PLAN 2. FOUNDATION WALLS UNSHADED TO BE DROPPED AS NOTED ON FOUNDATION PLAN FLOOR PLAN NOTE: 1. EXTERIOR WALLS SHALL BE FRAMED @ 16" o.c. 2. INTERIOR WALLS SHADED AS INDICATES INTERIOR LOAD BEARING WALL TO BE FRAMED @ 19.2" o.c. (UNLESS OTHERWISE NOTED ON PLAN) - ALIGN JOISTS w/ STUDS. 3. INTERIOR WALLS SHADED AS INDICATES INTERIOR WALLS TO BE FRAMED @ 16" o.c. 05/31/19 William Hohlt