HomeMy WebLinkAboutCLAY CORNER 23 - CC023 (AS DESIGNED)IECC 2009 Performance Compliance
Property
1552 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (A)
Community: CLAY CORNER 23
CCO23 (AS DESIGNED)
CLAY CORNER 23
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,330
$222
$392
$1,943
$673
$0
$2,617
Requirements
C-M,
Energy Solutions
As Designed
S1,254
S192
S392
$1,838
S573
SO
$2,511
C4405.3 Performance-based compliance passes by 5.4%
R402.4.12 Air Leakage Testing Air sealing is 6 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 5.4%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
4/25119 at 8:22 AM
Ekotrope RATER - Version 3.1.0.2158
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
�J PTO Pi
1552 JENSEN DR
CARMEL, IN 46032
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 6 ACH50
Window U -Value: 0.31, SHGC: 0.32
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 180.0 CFM @ 25Pa
Total Duct Leakage 240.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 4125119 at 8:22 AM
Ekotrope RATER - Version 3.1.0.2158
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
1552 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON (A)
Community: CLAY CORNER 23 Builder
LENNAR HOMES
CCO23 (AS DESIGNED)
CLAY CORNER 23
General Building Information
Conditioned Area (sq ft) 3,028
Conditioned Volume (cubic ft) 28,085
Insulated Shell Area (sq ft) 7,841
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (2,093 s.f.)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB 2X4 (2,312 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (440 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONUATTIC (463 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
1552 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (A)
Community: CLAY CORNER 23
CCO23 (AS DESIGNED)
CLAY CORNER 23
Rim Joist
El Name: CONDIAMB (49 s.f.)
R: 13.575
Name: CONDIATTIC (82 s.f.)
R: 13.575
Roof
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
El Name: SECOND (1,853 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
El Name: SLOPED (369 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
I_:I Name: FRONT (145 s.f.), U:0.310, SHGC: 0.29, Orientation: SOUTH
El Name: FRONT GD (24 s.f.), U:0.290, SHGC: 0.33, Orientation: SOUTH
11 Name: BACK 2X6 (90 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
11 Name: LEFT SIDE (48 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST
M Name: LEFT SIDE 2X6 (45 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST
C",
Energy Solutions
2
Energy Code Inspection Checklist
TSI Energy Solutions
Property Organization Inspection Status
1552 JENSEN DR TSI Energy Solutions Results are projected
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON (A)
Community: CLAY CORNER 23 Builder
LENNAR HOMES
CCO23 (AS DESIGNED)
CLAY CORNER 23
El Name: LEFT SIDE GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST
E] Name: RIGHT SIDE (93 s.f.), U: 0.310, SHGC: 0.32, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE
U Air conditioner • Electric • 100% Cooling Load @ 13 SEER
Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 2,809 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 180.0 CFM @ 25Pa 3
Total Duct Leakage is specified in Ekotrope at 240.0 CFM @ 25Pa
Energy Code Inspection Checklist
Property
1552 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON (A)
Community: CLAY CORNER 23
CCO23 (AS DESIGNED)
CLAY CORNER 23
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Surface Area
Property
C-MEnergy Solutions
Organization Inspection Status
1552 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON (A)
Community: CLAY CORNER 23
Builder
LENNAR HOMES
CCO23 [AS DESIGNED]
CLAY CORNER 23
GenerAuilding Information
Name Wall Construction Slab Completel Underslab Perimeter Perimeter
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
3;028
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu- ft.]
28;085
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
PENNINGTON (A)
Community
CLAY CORNER 23
Climate Zone
5A
I
Basement Wall
None Present
Basement Wall Library List
None Present
Slab
Name Library Type Perimeter Floor Grade Carpet R Exposed
Masonry Area
Surface Area
Location
Enclosing
SLAB R-10, 2'down 212
On Grade 0 0
2,093.0 sq. R.
Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Slab Completel Underslab Perimeter Perimeter
Thermal Break
Effective R -value
Type Insulated. Insulation
Width [ft] Insulation Depth [ft] Insulation
R Value
IR-10, 2'down Wood Frame /Other No
0 2
10
No
0.00
Framed Floor
None Present
1
Building Summary
Property
Organization
1552 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON [A]
Medium
Community: CLAY CORNER 23
Builder
CONDIAMB 2X6
LENNAR HOMES
CCO23 [AS DESIGNED]
440.0 sq. ft.
CLAY CORNER 23
CONDIATTIC
Framed Floor Library
Rim Joist
Name
CONDIAMB
CONDIATTIC
Rim Joist Library List
Name
G1 R-13. R-3.0
Library TypE
G1 R-13, R-3.0
C-M
Energy Solutions
Inspection Status
Results are projected
Surface Area Location
49.0 sq. ft. Exposed Exterior
G1 R-13, R-3.0 82.0 sq. ft. Attic
13.575
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB 2X4
G1 R-13 BATT, R-3 -0
Medium
2,312.0 sq. ft.
Exposed Exterior
CONDIAMB 2X6
G1 R-19, R-3.0 2X6
Medium
440.0 sq. ft.
Exposed Exterior
CONDIATTIC
G1 R-13 BATT, R-3.0
Medium
463.0 sq. ft.
Attic
CONDIGAR
G1 R-13 Gar Walls
Medium
180.0 sq. ft.
Unconditioned, attached garage
■
Wall Library List
Name
Effective R -value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
G1 R-19, R-3.0 2X6
20217
2
Building Summary
Property Organization
Inspection Status
C-MEnergy
Solutions
1552 JENSEN DR TSI Energy Solutions
Results are projected
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON [A]
Community: CLAY CORNER 23 Builder
LENNAR HOMES
CCO23 [AS DESIGNED]
CLAY CORNER 23
Glazing
Name Library Type Wall Assignment Basement Wall Overhang Depth
Overhang Ft Te
Overhang Ft Te
Orientation
Surface Area
Assignment
Top
Bottom
BACK 2X6 U-.31, SHGC-.32 CONDIAMB 2X6
0
0
❑
North
90.0 sq. fL
FRONT U-.31, SHGG29 CONDIAMB 2X4
❑
0
❑
South
145.0 sq. ft.
FRONT GD U-29, SHGG.33 CONDIAMB 2X4
0
0
❑
South
24.0 sq. fL
LEFT SIDE U-.31, SHGG.32 CONDIAMB 2X4
0
0
❑
West
48.0 sq. ft
LEFT SIDE 2X6 U-.31, SHGG.32 CONDIAMB 2X4
0
0
0
West
45.0 sq. fL
LEFT SIDE GD U-29, SHGG.33 CONDIAMB 2704
0
0
0
West
18.0 sq. ft
RIGHT SIDE U-.31, SHGC-.32 CONDIAMB 2X4
0
0
❑
East
93.0 sq. ft
Glazing Library List
Name Shgc
U factor
U-29, SHGC-.33 0.33
0290
U-.31, SHGC-29 029
0.310
U-.31, SHGC-.32 0.32
0.310
Skylight
Skylight Library List
3
Building Summary
Property Organization
1552 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON [A]
Community: CLAY CORNER 23 Builder
LENNAR HOMES
CCO23 [AS DESIGNED]
CLAY CORNER 23
Surface Area Location
Opaque Door
27.186
Name
Library Type Wall Assignmen,
FRONT
Steel Door CONDIAMB 2X4
GARAGE
6 ACH at 50 Pa Blower -door tested
Steel Door CONDIGAR
Opaque Door Library List A
Name E
sement Wall
Assign ment
0.182
C-M
Energy Solutions
Inspection Status
Results are projected
0.9 0.75 Medium 20.0 sq_ ft Exposed Exterior
0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior
Roof Insulation i
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area
P.f.] Tiles
Location
SECOND R-38 Blown, GR1 1,853 No Medium 1,853.0 sq. ft Attic
SLOPED R-30 Vaulted, GR1 369 No Medium 369.0 sq. ft Attic
Roof Insulation Library List
Solar Surface Color
Surface Area Location
Absorptance
27.186
0.9 0.75 Medium 20.0 sq_ ft Exposed Exterior
0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior
Roof Insulation i
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area
P.f.] Tiles
Location
SECOND R-38 Blown, GR1 1,853 No Medium 1,853.0 sq. ft Attic
SLOPED R-30 Vaulted, GR1 369 No Medium 369.0 sq. ft Attic
Roof Insulation Library List
Name Has Radiant Barrier
Effective R -value
R-30 Vaulted. GR l No
27.186
R-38 Blown. GR1 No
38.268
Whale House Infiltration
Infiltration Measurement Type
Shelter Class
6 ACH at 50 Pa Blower -door tested
4
M
Building Summary
Property
1552 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [A]
Community: CLAY CORNER 23
CCO23 [AS DESIGNED]
CLAY CORNER 23
F Mechanical Ventilation
Lighting
o Interior Fluorescent
Lighting
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
% Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting
Lighting
900 10 7DO
Onsite Generation
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
C-M,
Energy Solutions
Lighting
0
100
Building Summary
Property
Organization
Inspection Status
1552 JENSEN DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Matthew Timmons
PSG (Single Speed)
Model: PENNINGTON (A)
95.5 AFUE
Heating Capacity [kBtulh]
Community: CLAY CORNER 23
Builder
No
EAE [kWh]
LENNAR HOMES
Equipment Type: CA13NA042
CCO23 [AS DESIGNED]
Fuel Type
Electric
CLAY CORNER 23
Forced Air
Motor Type
Conditioning Equipment
Cooling Efficiency
13 SEER
Name
Library Type
Heating Percent Load Co(
Air conditioner
Equipment Type: RE350*
CA13NA042
0%
I Fuel -fired air 9155A4206OS17 100%
distribution
IWater Heating RE350" 0%
1
Equipment Type: 915SA4206OS17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
58
Use default EAE
No
EAE [kWh]
636
Equipment Type: CA13NA042
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
46
Equipment Type: RE350*
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
C-M,
Energy Solutions
g Percent Load Hot Water
100% 0%
0% 0%
0% 100%
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
1552 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: PENNINGTON [A]
Community: CLAY CORNER 23
Builder
LENNAR HOMES
CCO23 [AS DESIGNED]
CLAY CORNER 23
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
3628
# Return Grilles
4
Supply Duct R Value
30
Return Duct R Value
20
Supply Duct Area [sq. ft.]
782.46
Return Duct Area [sq. ft_]
579.6
Duct Leakage to Outdoors (CFM25)
186
Total Leakage
246
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rCeiling Fan W
Has Ceiling Fan No
Cfm Per Watt 101
7
Building Summary
Property
1552 JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [A]
Community: CLAY CORNER 23
CCO23 [AS DESIGNED]
CLAY CORNER 23
Water Distribution MM
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Standard
No
75
No
No
30
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�