HomeMy WebLinkAboutEnergy compliance - JGH021 (AS DESIGNED)IECC 2009 Performance Compliance Property 12098 SIGILLARY LANE CARMEL, IN 46032 Model: CROXDALE Community: HAMLET AT JACKSON JGH021 (AS DESIGNED) HAMLET AT JACKSONS GRANT 21 Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,476 $199 $280 $1,955 $812 $0 $2,767 Requirements C-M, Energy Solutions As Designed $1,340 $166 $280 $1,785 $812 $0 $2,597 C4405.3 Performance-based compliance passes by 8.7% R402.4.1.2 Air Leakage Testing Air sealing is 5.0[) ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 8.7%. Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name Organization Devin Sielschott TSI Energy Solutions Signature: Date: 5/13119 at 12:13 PM Ekotrope RATER - Version 3.1.0.2170 IECC 2009 Performance compliance results calculated using Eketrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all1iabitityfor the information shown on this report. 12098 SIGILLARY LANE CARMEL, IN 46032 Builder: HOMES BY McKENZIE, INC. Ceiling Attic, R-50 Above Grade Walls R-15 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U -Value: 0.29, SHGC: 0.27 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 156.0 CFM @ 25Pa Total Duct Leakage 208.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric - 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 5/13119 at 12:13 PM Ekotrope RATER - Version 3.1.0.2170 2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 12098 SIGILLARY LANE TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSON Builder HOMES BY McKENZIE, JGH021 (AS DESIGNED) INC. HAMLET AT JACKSONS GRANT 21 General Building Information Conditioned Area (sq ft) 2,675 Conditioned Volume (cubic ft) 30,415 Insulated Shell Area (sq ft) 7,770 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (1,890 s.f.) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall Name: CONDIAMB (1,833 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CON DIAMB 2X6 (1,540 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CON DIGAR (430 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIATTIC (99 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Cade Inspection Checklist Property 12098 SIGILLARY LANE CARMEL, IN 46032 Model: CROXDALE Community: HAMLET AT JACKSON JGH021 (AS DESIGNED) HAMLET AT JACKSONS GRANT 21 Rim Joist Name: CONDIAMB (55 s.f.) l--1 R: 11.691 Name: CONDIATTIC (33 s.f.) R: 11.691 Roof Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY McKENZIE, INC. 1� Name: MAIN (1,890 s.f.) 1--1 R-39.73 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door 1� Name: GARAGE (24 s.f.) 1--1 U: 0.182 Glazing Inspection Status Results are projected 11 Name: FRONT 2X6 (160 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH Name: FRONT 2X6 GD (24 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH E] Name: BACK 2X6 (43 s.f.), U: 0.300, SHGC: 0.26, Orientation: SOUTH E] Name: BACK 2X4 (11 s.f.), U: 0.300, SHGC: 0.26, Orientation: SOUTH Name: LEFT SIDE 2X6 (45 s.f.), U: 0.290, SHGC: 0.27, Orientation: EAST E] Name: LEFT SIDE (180 s.f.), U: 0.290, SHGC: 0.27, Orientation: EAST El Name: RIGHT SIDE 2X6 (25 s.f.), U: 0.290, SHGC: 0.27, Orientation: WEST C-M, Energy Solutions 2 Energy Code Inspection Checklist Property TSI Energy Solutions Organization Inspection Status 12098 SIGILLARY LANE TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSON Builder HOMES BY McKENZIE, JGH021 (AS DESIGNED) INC. HAMLET AT JACKSONS GRANT 21 Name: RIGHT SIDE (14 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE 1I Air conditioner • Electric • 100% Cooling Load @ 13 SEER El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 2,535 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 156.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 208.0 CFM @ 25Pa 3 Energy Code Inspection Checklist Property Organization 12098 SIGILLARY LANE TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSON Builder HOMES BY McKENZIE, JGH021 (AS DESIGNED) INC. HAMLET AT JACKSONS GRANT 21 Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 3 CFM251 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization 12098 SIGILLARY LANE TSI Energy Solutions CARMEL, N 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 21 Builder HOMES BY McKENZIE, INC. JGH021 (AS DESIGNED) HAMLET AT JACKS ONS GRANT 21 General Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq_ ft.] Unconditioned; attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Basement Wall Basement Wall Library List Slab AL Name Library Type SLAB R-10, 1'down, Tin J= 2 2 2,675 Yes 34,415 1 Single family detached CROXDALE HAMLET AT JACKSONS GRANT 21 5A None Present Inspection Status Results are projected C-M, Energy Solutions 240 On Grade 1.23 0 1,890.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Camplet Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, 3' in Wood Frame 1 Other No 3 1 10 No 10.00 Framed Floor None Present 1 Building Summary Property Organization 12098 SIGILLARY LANE TSI Energy Solutions CARMEL, N 46032 Devin Sielschott Model: CROXDALE Medium Community: HAMLET AT JACKSONS GRANT 21 Builder CONDIAMB 2X6 HOMES BY McKENZIE, INC. JGH021 (AS DESIGNED) 1,540.0 sq. tt. HAMLET AT JACKS ONS GRANT 21 CONDIATTIC Framed Floor Library List _ None Present Rim JoistA Name CONDIAMB CONDIATTIC Rim Joist Library List Name G1 R-15. OSB 1 uorary TYPE G1 R-15, OSB C-M Energy Solutions Inspection Status Results are projected Surface Area Location 55.0 sq. ft. Exposed Exterior G1 R-15, OSB 33.0 sq. ft. Attic t -value 11.691 Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-15 BATT, OSB Medium 1,833.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19, OSB 2x6 Medium 1,540.0 sq. tt. Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 99.0 sq. tt. Attic CONDIGAR G1 R-13 Gar Walls Medium 430.0 sq. 11 Unconditioned; attached garage Wall Library List Name Effective R -value G1 R-13 Gar Walls 11.141 G1 R-15 BATT, OSB 13.423 G1 R-19, OSB 2x6 17.591 2 Building Summary Property Organization Inspection Status C-MEnergy Solutions 12098 SIGLLARY LANE TSI Energy Solutions I Results are projected CARMEL, N 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 21 Builder HOMES BY MCKENZIE, INC. JGH021 (AS DESIGNED) HAMLET AT JACKSONS GRANT 21 Glazing Name Library type Wall Assignment Basement Wall Overhang Assignment Depth Overhang Ft To Overhang Tap Ft To Isottom Orientation Surface Area BACK 2X4 111-.30, SHGC-26 CONDIAMB 0 0 0 South 11.0 sq. ft. BACK 2X6 111-.30, SHGC-26 CON DIAMB 2X6 0 0 0 South 43.0 sq. ft. FRONT 2X6 U-29, SHGC-27 CONDIAMB 2X6 0 0 0 North 160.0 sq. ft. FRONT 2X6 GD U-29, SHGC-27 CON DIAMB 2X6 0 0 0 North 24.0 sq. R. LEFT SIDE U-29, SHGC-27 CONDIAMB 0 0 0 East 180.0 sq. R. LEFT SIDE 2X6 U-29, SHGC-27 CONDIAMB 2X6 0 0 0 East 45.0 sq. R. RIGHT SIDE U-29, SHGC-27 CONDIAMB 0 0 0 West 14.0 sq. ft. RIGHT SIDE 2X6 U-29, SHGC-27 CONDIAMB 2X6 0 0 0 West 25.0 sq. ft. Glazing Library List Name Singe U -factor U-29, SHGC-27 027 0290 U-.30, SHGC-26 026 0.300 Skylight None Present Skylight Library List None Present 3 Building Summary Property Organization Inspection Status C-MEnergy Solutions I 12098 SIGLLARY LANE TSI Energy Solutions Results are projected CARMEL, N 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSONS. GRANT 21 Builder HOMES BY MCKENZIE, INC. JGH021 (AS DESIGNED) HAMLET AT JACKSONS GRANT 21 Opaque Door Name Library type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab so rp to n ce GARAGE Steel Door CONDlGAR 0.9 0.75 Medium 24.0 sq. ft. Exposed Exterior Opaque Door Library List Name Effective U -factor Steel Door Roof Insulation Name 0.182 P.f.] - Tiles MAIN R-50 Blown, GR1 1,890 No Roof Insulation Library List Name Has Radiant Barrier R-50 Blown, GRi Whole House Infiltration Infiltration 5 ACH at 50 Pa `J c Measurement Type Blower -door tested Mechanical Ventilation None Present Effective R -value 50.474 Shelter Glass Medium 1.890.0 sq. ft. Attic 4 Building Summary Property Organization Inspection Status C-MEnergy Solutions I 12098 SIGLLARY LANE TSI Energy Solutions Results are projected CARMEL, N 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 21 Builder HOMES BY MCKENZIE, INC. JGH021 (AS DESIGNED) HAMLET AT JACKSONS GRANT 21 Lighting /o Interior Fluorescent % Interior LED Lighting % Exterior Fluorescent % Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting 0 0 0 0 0 0 Onsite Generation - None Present Onsite Generation Library List - None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Air conditioner CA13NA060 0% 100% 0% Fuel -fired air 912SA6010OS17 100% 0% 0% distribution Water Heating ENT 50 100 0% 0% 100% Building Summary Property 12098 SIGILLARY LANE CARMEL, N 46032 Madel: CROXDALE Community: HAMLET AT JACKSONS GRANT 21 JGH021 (AS DESIGNED) HAMLET AT JACKSONS GRANT 21 rr ment Type: e on Type pe Efficiency Capacity [kBtulh] ult EAE h] Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. 912SA60100517 ipment Type: CA13NA060 Natural Gas Forced Air PSG (Single Speed) 92.1 AFUE 97.1 Yes 1.149.1 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 58.2 Equipment Type: ENT 50 100 Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property Organization 12098 SIGILLARY LANE TSI Energy Solutions CARMEL, N 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 21 Builder HOMES BY MCKENZIE, INC. JGH021 (AS DESIGNED) HAMLET AT JACKS ONS GRANT 21 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 2675 # Return Grilles 4 Supply Duct R Value 10 Return Duct R Value 10 Supply Duct Area [sq. ft.] 722.25 Return Duct Area [sq. ft] 535 Duct Leakage to Outdoors (CFM25) 156 Total Leakage 208 Total Leakage Dud Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Attic (well vented, under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 12098 SIGILLARY LANE CARMEL, N 46032 Madel: CROXDALE Community: HAMLET AT JACKSONS GRANT 21 JGH021 (AS DESIGNED) HAMLET AT JACKSONS GRANT 21 Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 66 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 136 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.617 Field Utilization Timer Controls asher VWV Label Energy Rating 764 kWh/Year Electric Rate $0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 1 met 0.33053 Appliances and Controls M Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Electric Convection Oven? No Induction Range? No Refrigerator Consumption 709 kVVh/Year Inspection Status Results are projected C-M, Energy Solutions