HomeMy WebLinkAboutEnergy compliance - JGH021 (AS DESIGNED)IECC 2009 Performance Compliance
Property
12098 SIGILLARY LANE
CARMEL, IN 46032
Model: CROXDALE
Community: HAMLET AT JACKSON
JGH021 (AS DESIGNED)
HAMLET AT JACKSONS GRANT 21
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE,
INC.
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,476
$199
$280
$1,955
$812
$0
$2,767
Requirements
C-M,
Energy Solutions
As Designed
$1,340
$166
$280
$1,785
$812
$0
$2,597
C4405.3
Performance-based compliance passes by 8.7%
R402.4.1.2
Air Leakage Testing Air sealing is 5.0[) ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa.
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U -Factor
403.2.2
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R405.2
Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 8.7%.
Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name
Organization
Devin Sielschott
TSI Energy Solutions
Signature:
Date:
5/13119 at 12:13 PM
Ekotrope RATER - Version 3.1.0.2170
IECC 2009 Performance compliance results calculated using Eketrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all1iabitityfor the information shown on this report.
12098 SIGILLARY LANE
CARMEL, IN 46032
Builder: HOMES BY McKENZIE, INC.
Ceiling Attic, R-50
Above Grade Walls R-15
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 5 ACH50
Window U -Value: 0.29, SHGC: 0.27
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 156.0 CFM @ 25Pa
Total Duct Leakage 208.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric - 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 5/13119 at 12:13 PM
Ekotrope RATER - Version 3.1.0.2170
2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property Organization
12098 SIGILLARY LANE TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSON Builder
HOMES BY McKENZIE,
JGH021 (AS DESIGNED) INC.
HAMLET AT JACKSONS GRANT 21
General Building Information
Conditioned Area (sq ft) 2,675
Conditioned Volume (cubic ft) 30,415
Insulated Shell Area (sq ft) 7,770
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (1,890 s.f.)
R-10 perimeter insulation, R-10 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
Name: CONDIAMB (1,833 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CON DIAMB 2X6 (1,540 s.f.)
R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CON DIGAR (430 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (99 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Energy Cade Inspection Checklist
Property
12098 SIGILLARY LANE
CARMEL, IN 46032
Model: CROXDALE
Community: HAMLET AT JACKSON
JGH021 (AS DESIGNED)
HAMLET AT JACKSONS GRANT 21
Rim Joist
Name: CONDIAMB (55 s.f.)
l--1 R: 11.691
Name: CONDIATTIC (33 s.f.)
R: 11.691
Roof
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY McKENZIE,
INC.
1� Name: MAIN (1,890 s.f.)
1--1 R-39.73 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
1� Name: GARAGE (24 s.f.)
1--1 U: 0.182
Glazing
Inspection Status
Results are projected
11 Name: FRONT 2X6 (160 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH
Name: FRONT 2X6 GD (24 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH
E] Name: BACK 2X6 (43 s.f.), U: 0.300, SHGC: 0.26, Orientation: SOUTH
E] Name: BACK 2X4 (11 s.f.), U: 0.300, SHGC: 0.26, Orientation: SOUTH
Name: LEFT SIDE 2X6 (45 s.f.), U: 0.290, SHGC: 0.27, Orientation: EAST
E] Name: LEFT SIDE (180 s.f.), U: 0.290, SHGC: 0.27, Orientation: EAST
El Name: RIGHT SIDE 2X6 (25 s.f.), U: 0.290, SHGC: 0.27, Orientation: WEST
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property
TSI Energy Solutions
Organization Inspection Status
12098 SIGILLARY LANE
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSON
Builder
HOMES BY McKENZIE,
JGH021 (AS DESIGNED)
INC.
HAMLET AT JACKSONS GRANT 21
Name: RIGHT SIDE (14 s.f.),
U:0.290, SHGC: 0.27, Orientation: WEST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE
1I Air conditioner • Electric • 100% Cooling Load @ 13 SEER
El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 2,535 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 156.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 208.0 CFM @ 25Pa
3
Energy Code Inspection Checklist
Property Organization
12098 SIGILLARY LANE TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSON Builder
HOMES BY McKENZIE,
JGH021 (AS DESIGNED) INC.
HAMLET AT JACKSONS GRANT 21
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 3 CFM251 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization
12098 SIGILLARY LANE
TSI Energy Solutions
CARMEL, N 46032
Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 21
Builder
HOMES BY McKENZIE, INC.
JGH021 (AS DESIGNED)
HAMLET AT JACKS ONS GRANT 21
General Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq_ ft.]
Unconditioned; attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Floor Number
Model
Community
Climate Zone
Basement Wall
Basement Wall Library List
Slab AL
Name Library Type
SLAB R-10, 1'down, Tin
J=
2
2
2,675
Yes
34,415
1
Single family detached
CROXDALE
HAMLET AT JACKSONS GRANT 21
5A
None Present
Inspection Status
Results are projected
C-M,
Energy Solutions
240 On Grade 1.23 0 1,890.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction Slab Camplet Underslab Perimeter Perimeter Thermal Break Effective R -value
Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
R-10, 1'down, 3' in Wood Frame 1 Other No 3 1 10 No 10.00
Framed Floor
None Present
1
Building Summary
Property
Organization
12098 SIGILLARY LANE
TSI Energy Solutions
CARMEL, N 46032
Devin Sielschott
Model: CROXDALE
Medium
Community: HAMLET AT JACKSONS GRANT 21
Builder
CONDIAMB 2X6
HOMES BY McKENZIE, INC.
JGH021 (AS DESIGNED)
1,540.0 sq. tt.
HAMLET AT JACKS ONS GRANT 21
CONDIATTIC
Framed Floor Library List _
None Present
Rim JoistA
Name
CONDIAMB
CONDIATTIC
Rim Joist Library List
Name
G1 R-15. OSB
1
uorary TYPE
G1 R-15, OSB
C-M
Energy Solutions
Inspection Status
Results are projected
Surface Area Location
55.0 sq. ft. Exposed Exterior
G1 R-15, OSB 33.0 sq. ft. Attic
t -value
11.691
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-15 BATT, OSB
Medium
1,833.0 sq. ft.
Exposed Exterior
CONDIAMB 2X6
G1 R-19, OSB 2x6
Medium
1,540.0 sq. tt.
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, OSB
Medium
99.0 sq. tt.
Attic
CONDIGAR
G1 R-13 Gar Walls
Medium
430.0 sq. 11
Unconditioned; attached garage
Wall Library List
Name
Effective R -value
G1 R-13 Gar Walls
11.141
G1 R-15 BATT, OSB
13.423
G1 R-19, OSB 2x6
17.591
2
Building Summary
Property Organization
Inspection Status
C-MEnergy
Solutions
12098 SIGLLARY LANE TSI Energy Solutions
I
Results
are projected
CARMEL, N 46032 Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 21 Builder
HOMES BY MCKENZIE, INC.
JGH021 (AS DESIGNED)
HAMLET AT JACKSONS GRANT 21
Glazing
Name Library type Wall Assignment Basement Wall Overhang
Assignment
Depth
Overhang Ft To Overhang
Tap
Ft To
Isottom
Orientation
Surface Area
BACK 2X4 111-.30, SHGC-26 CONDIAMB
0
0
0
South
11.0 sq. ft.
BACK 2X6 111-.30, SHGC-26 CON DIAMB 2X6
0
0
0
South
43.0 sq. ft.
FRONT 2X6 U-29, SHGC-27 CONDIAMB 2X6
0
0
0
North
160.0 sq. ft.
FRONT 2X6 GD U-29, SHGC-27 CON DIAMB 2X6
0
0
0
North
24.0 sq. R.
LEFT SIDE U-29, SHGC-27 CONDIAMB
0
0
0
East
180.0 sq. R.
LEFT SIDE 2X6 U-29, SHGC-27 CONDIAMB 2X6
0
0
0
East
45.0 sq. R.
RIGHT SIDE U-29, SHGC-27 CONDIAMB
0
0
0
West
14.0 sq. ft.
RIGHT SIDE 2X6 U-29, SHGC-27 CONDIAMB 2X6
0
0
0
West
25.0 sq. ft.
Glazing Library List
Name Singe
U -factor
U-29, SHGC-27 027
0290
U-.30, SHGC-26 026
0.300
Skylight
None Present
Skylight Library List
None Present
3
Building Summary
Property
Organization
Inspection Status C-MEnergy Solutions
I
12098 SIGLLARY LANE
TSI Energy Solutions
Results are projected
CARMEL, N 46032
Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSONS. GRANT 21
Builder
HOMES BY MCKENZIE, INC.
JGH021 (AS DESIGNED)
HAMLET AT JACKSONS GRANT 21
Opaque Door
Name Library type Wall Assignment Basement Wall
Emittance Solar Surface Color Surface Area Location
Assignment
Ab so rp to n ce
GARAGE Steel Door
CONDlGAR
0.9 0.75 Medium 24.0 sq. ft. Exposed Exterior
Opaque Door Library List
Name Effective U -factor
Steel Door
Roof Insulation
Name
0.182
P.f.] - Tiles
MAIN R-50 Blown, GR1 1,890 No
Roof Insulation Library List
Name Has Radiant Barrier
R-50 Blown, GRi
Whole House Infiltration
Infiltration
5 ACH at 50 Pa
`J c
Measurement Type
Blower -door tested
Mechanical Ventilation
None Present
Effective R -value
50.474
Shelter Glass
Medium 1.890.0 sq. ft. Attic
4
Building Summary
Property
Organization
Inspection Status
C-MEnergy Solutions
I
12098 SIGLLARY LANE
TSI Energy Solutions
Results are projected
CARMEL, N 46032
Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 21
Builder
HOMES BY MCKENZIE, INC.
JGH021 (AS DESIGNED)
HAMLET AT JACKSONS GRANT 21
Lighting
/o Interior Fluorescent % Interior LED Lighting
% Exterior Fluorescent
% Exterior LED Lighting
% Garage Fluorescent % Garage LED Lighting
Lighting
Lighting
Lighting
0 0
0
0
0 0
Onsite Generation
-
None Present
Onsite Generation Library List -
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load
Air conditioner CA13NA060 0% 100% 0%
Fuel -fired air 912SA6010OS17 100% 0% 0%
distribution
Water Heating ENT 50 100 0% 0% 100%
Building Summary
Property
12098 SIGILLARY LANE
CARMEL, N 46032
Madel: CROXDALE
Community: HAMLET AT JACKSONS GRANT 21
JGH021 (AS DESIGNED)
HAMLET AT JACKSONS GRANT 21
rr
ment Type:
e
on Type
pe
Efficiency
Capacity [kBtulh]
ult EAE
h]
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE, INC.
912SA60100517
ipment Type: CA13NA060
Natural Gas
Forced Air
PSG (Single Speed)
92.1 AFUE
97.1
Yes
1.149.1
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 58.2
Equipment Type: ENT 50 100
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
Organization
12098 SIGILLARY LANE
TSI Energy Solutions
CARMEL, N 46032
Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 21
Builder
HOMES BY MCKENZIE, INC.
JGH021 (AS DESIGNED)
HAMLET AT JACKS ONS GRANT 21
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
2675
# Return Grilles
4
Supply Duct R Value
10
Return Duct R Value
10
Supply Duct Area [sq. ft.]
722.25
Return Duct Area [sq. ft]
535
Duct Leakage to Outdoors (CFM25)
156
Total Leakage
208
Total Leakage Dud Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
12098 SIGILLARY LANE
CARMEL, N 46032
Madel: CROXDALE
Community: HAMLET AT JACKSONS GRANT 21
JGH021 (AS DESIGNED)
HAMLET AT JACKSONS GRANT 21
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE, INC.
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
66
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
136
Drain Water Heat Recovery?
No
Clothes Dryer
Fuel Type Electric
Cef 2.617
Field Utilization Timer Controls
asher VWV
Label Energy Rating
764 kWh/Year
Electric Rate
$0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.581Therm
Capacity
2.874
1 met
0.33053
Appliances and Controls
M
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Electric
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
709 kVVh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions