Loading...
HomeMy WebLinkAboutLEGACY RIDGE 95 - LR095 (AS DESIGNED)IECC 2009 Performance Compliance Property 6789 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (C) Community: LEGACY RIDGE 95 LR095 (AS DESIGNED) LEGACY RIDGE 95 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,905 $290 $411 $2,607 $959 $0 $3,565 Requirements C-M, Energy Solutions As Designed $1,906 $269 $411 $2,586 $959 $0 $3,545 C4405.3 Performance-based compliance passes by 0.8% R402.4.12 Air Leakage Testing Air sealing is 6 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 0.8%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 5114119 at 9:24 AM Ekotrope RATER - Version 3.1.0.2171 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 6789 PULASKI CT 4Fri MI CARMEL, IN 46033 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 6 ACH50 Window U -Value: 0.32, SHGC: 0.31 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 328.0 CFM @ 25Pa Total Duct Leakage 437.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 5114119 at 9:24 AM Ekotrope RATER - Version 3.1.0.2171 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 6789 PULASKI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (C) Community: LEGACY RIDGE 95 Builder LENNAR HOMES LRO95 (AS DESIGNED) LEGACY RIDGE 95 General Building Information Conditioned Area (sq ft) 5,469 Conditioned Volume (cubic ft) 48,294 Insulated Shell Area (sq ft) 10,186 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (1,951 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: AMBIENT (15 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 178, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 31, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (3,204 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (468 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 6789 PULASKI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOLITHILL (C) Community: LEGACY RIDGE 95 Builder LENNAR HOMES LRO95 (AS DESIGNED) LEGACY RIDGE 95 Name: CONDIGAR (279 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (255 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (314 s.f.) R: 13.575 Name: CONDIGAR (31 s.f.) R: 10.876 El Name: CONDIATTIC (31 s.f.) R: 13.575 Roof El Name: MAIN (1,966 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door J --G Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (138 s.f.), U:0.320, SHGC: 0.28, Orientation: EAST El Name: BACK (210 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST C-M, Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 6789 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (C) Community: LEGACY RIDGE 95 Builder LENNAR HOMES LRO95 (AS DESIGNED) LEGACY RIDGE 95 E] Name: BACK BSMT (11 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST E] Name: SLIDER (40 s.f.), U:0.280, SHGC: 0.32, Orientation: WEST El !Name: RIGHT SIDE (82 s.f.), U:0.320, SHGC: 0.31, Orientation: NORTH El Name: LEFT SIDE (121 s.f.), U:0.320, SHGC: 0.31, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 92.1 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4,829 CFM50 (6.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 6789 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (C) Community: LEGACY RIDGE 95 LRO95 (AS DESIGNED) LEGACY RIDGE 95 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 328.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 437.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 6789 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (C) Community: LEGACY RIDGE 9 Builder LENNAR HOMES LRO95 (AS DESIGNED LEGACY RIDGE 95 General Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 5;469 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 48;294 Total Units in Building 1 Residence Type Single family detached Floor Number Model SOUTHILL (C) Community LEGACY RIDGE 95 Climate Zone 5A C-M, Energy Solutions Basement Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4Pt 1 7 178 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4Pt 1 7 31 Exposed Exterior Conditioned Space w' Basement Wall Literary List Name Feet From Wall Top To Insulation Feet From Wall Top To Insulation Is Fully Insulated Effective Insulation R -value Top Bottom R-11 Draped, Oft 0 4 No 11.00 Slab BSMT Uninsulated 1 Below Grade 0 0 1,951.0 sq. ft. Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective 11-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame/ Other No 0 0 0 No 1).00 1 Building Summary Property Organization 6789 PULASKI CT TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOUTHILL (C) Surface Calor Community: LEGACY RIDGE 95 Builder CONDIAMB LENNAR HOMES LR095 (AS DESIGNED. 3,204.0 sq. ft. LEGACY RIDGE 95 CONDIAMB 2X6 ramed Floor Medium Name Library Type Ca AMBIENT R-38, GR1 G1 R-13 BATT, R-3.0 Medium 255.0 sq. ft. Framed Floor Library List Name Effective R -value R-38, GRi 2 33.825 Rim Joist Name Library Type CONDIAMB G1 R-13, R-3.0 CONDIATTIC G1 R-13, R-3.0 CONDIGAR G1 R-13, OSB Rim Joist Library List Name Effective Insulation R -value G1 R-13, OSB 10.876 G1 R-13. R-3.0 13.575 C-M Energy Solutions Inspection Status Results are projected e Surface Area Location 1.23 Above Grade 15.0 sq. ft Exposed Exterior 314.0 sq. ft. Exposed Exterior 31.0 sq. 11 Attic 31.0 sq. ft. Unconditioned, attached garage ali Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-13 BATT, R-3.0 Medium 3,204.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 468.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 255.0 sq. ft. Attic 2 Building Summary Property 6789 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (C) Community: LEGACY RIDGE 95 LRO95 (AS DESIGNED) LEGACY RIDGE 95 Name Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Library Type Inspection Status Results are projected Surface Calor Surface Area C-MEnergy Solutions Location CONDIGAR G1 R-13 Gar Walls Medium 279.0 sq. ft. Unconditioned, attached garage Wall Library List Name Effective R -value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 Glazing Name Library Type Wall Assignment Basement Wall Assignment Overhang Depth Overhang Ft Top To Overhang Ft To Bottom Orientation Surface Area BACK U-.32, SHGG.31 CONDIAMB 0 0 0 West 210.0 sq. ft. BACK BSMT U-.32, SHGC-.31 CONDIAMB 0 0 0 West 11.0 sq. ft. FRONT U-.32, SHGG28 CONDIAMB 0 0 ❑ East 138.0 sq. ft. LEFT SIDE U-.32, SHGG.31 CONDIAMB 0 0 ❑ South 121.0 sq. ft. RIGHT SIDE U-.32, SHGG.31 CONDIAMB 0 0 ❑ North 82.0 sq. ft SLIDER U-28, SHGG.32 CONDIAMB 0 0 ❑ West 40.0 sq. ft Glazing Library List Name Shg c U factor U-28, SHGC-.32 0.32 0280 U-.32, SHGC-28 028 0.320 U-.32, SHGC-.31 0.31 0.320 Building Summary Property 6789 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (C) Community: LEGACY RIDGE 95 LRO95 (AS DESIGNED) LEGACY RIDGE 95 kylight Skylight Library List Opaque Door Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Name Library Type Wall Assignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta nce FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 sq. ft Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 sq- ft Exposed Exterior Opaque Door Library List Name Effective U -factor 0.182 Roof Insulation Name imm Library Typ MAIN R-38 Blown. GR1 krea Clay or Concrete Root P.f.] Tiles 93S No Roof Insulation Library List Name Has Radiant Barrier Effective R -value '•0 �- -I :a l No 38268 n Medium 1,966.0 sq. ft Attic 4 Building Summary Property 6789 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (C) Community: LEGACY RIDG: 9 - LRO95 (AS DESIGNED LEGACY RIDGE 95 FWhole House Infiltration Infiltration 6 ACH at 50 Pa Mechanical Ventilation Lighting , °I Interior Fitiorescent Lighting Onsite Generation Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Blower -door tested 4 rang Y. t)senor rmorescem Lighting 100 0 None Present Onsite Generation Library List None Present Solar Generation Solar Generation Library List C-M, Energy Solutions Lighting 1❑0 Building Summary Property Organization Inspection Status 6789 PULASKI CT TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons PSG (Single Speed) Model: SOUTHILL (C) 92.1 AFUE Heating Capacity [kBtulh] Community: LEGACY RIDG: 9- Builder No EAE [kWh] LENNAR HOMES Equipment Type: CA13NA042 LRO95 (AS DESIGNED Fuel Type Electric LEGACY RIDGE 95 Forced Air Motor Type onditioning Equipment Cooling Efficiency 13 SEER Name Library Type Heating Percent Load Co( Air conditioner (2) Equipment Type: RE350* CA13NA042 0% C-M, Energy Solutions g Percent Load Hot Water 100% 0% Fuel4red air 912SA4808OS17 100% 0% 0% distribution (1) Water Heating (3) RE350" 0% 0% 100% 1 Equipment Type: 912SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 977 Equipment Type: CA13NA042 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 Building Summary Property 6789 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (C) Community: LEGACY RIDG: 9. LRO95 (AS DESIGNED. LEGACY RIDGE 95 1butivn System tion Type Equipment Equipment t Served i Grilles Xct R Value )uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Forced Air Fuel -fired air distribution (1) Air conditioner (2) 5469 6 3❑ 3❑ 1107.5 1025.4 328 437 Post -Construction Yes Conditioned Space 7❑ 70 Attic (well vented; under insulation) 3❑ 3❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No C-M, Energy Solutions 7 Building Summary Property 6789 PULASKI CT CARMEL, IN 46033 Model: SOUTHILL (C) Community: LEGACY RIDGE 55 LRO95 (AS DESIGNEI.: LEGACY RIDGE 95 ater Distribution Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 125 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 20 Drain Water Heat Recovery? No r othes Dryer elType Electric f 2.32 ld utilization Timer Controls Clothes Washer Label Energy Rating 704 kWh/Year Electric Rate 0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.847 1 mef 0.331 Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Yes Standard 270 kWh Electric No No 709 kWh/Year "M � TSI Energy Solutions ,�