HomeMy WebLinkAboutE001 - 6GG33 33
3SINGLE POLE SWITCH
THREE WAY SWITCH
FOUR WAY SWITCH
SMOKE DETECTOR
TELEPHONE JACK
TV/ DATA
EXHAUST FAN
DUPLEX OUTLET
WEATHER PROOF OUTLET
GROUND FAULT OUTLET
220V OUTLET
RECESSED EYEBALL LIGHT
EYE
CEILING FIXTURE
WALL MOUNT FIXTURE
FLUORESCENT FIXTURE
RECESSED FIXTURE
TRACK FIXTURET
UNDER CABINET FIXTURE
EXTERIOR FLOOD LIGHT
WIRE FOR PADDLE FAN
WIRE FOR PADDLE FAN
AND LIGHT KIT
CS 34 WP
GFI
220V
BEDROOM #4 CLOSET
BATH 4
GAME ROOM
THEATER
MECHANICAL/
STORAGE
GLIGHTFAN TO SWITCH ABOVECS CS
PROVISIONCRAWL
SPACE
UU
SLAB RECESSED 4"
EJECT.SUMPWATERHEATERWATERSOFTENERR.I.FURNZERO THRESHOLDSHOWER ABOVE2x10 FJ HUNG FROM
JOIST HEADERCUSTOMER:
PROJECT NAME:LOCATION:DRAWING TITLE: DRAWN BY:Wedgewood
Building Co., LLC
317.669.6300
32 First Street NE
Carmel, IN 46032
www.wedgewoodbc.com
Copyright c 2019 Wedgewood Building Co. LLC. 5/28/2019
1:30:16 PM
E1
Wedgewood Building Co.
Spec Residence
Lot #6 - Grannan Grove
BASEMENT ELEC. PLAN WBC 1/4" = 1'-0" 3 BASEMENT ELECTRICAL PLAN Rev.No. Date DescriptionELECTRICAL PLAN NOTES:
1. REFER TO COVER PAGE FOR SPANISH TRANSLATIONS = REFERIRSE A LA PORTADA DE LAS TRADUCCIONES AL ESPAÑOL.
By Andrew Lund at 1:30 pm, May 28, 2019
06/06/19
Mike Sheeks