HomeMy WebLinkAboutI37216396.659_West_Clay_Northlake16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). May 28,2019 Liu, Xuegang Pages or sheets covered by this seal: I37216396 thru I37216463 My license renewal date for the state of Indiana is July 31, 2020. 659_West_Clay_Northlake 659 West Clay Northlake IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss GE01 Truss Type GABLE Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216396 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:43:59 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-qN7TwJoN6?8J6GJxdHuM6Jq_Hyp0W2AXFrLxVFzC0lU Scale = 1:68.5 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 2930 31 32 63 62 61 60 59 58 57 56 55 54 53 5251 50 49 48 47 46 4544 43 42 41 40 39 38 37 36 35 34 33 3x6 5x6 3x6 3x6 3x6 38-11-0 38-11-0 -1-0-0 1-0-0 19-5-8 19-5-8 38-11-0 19-5-8 0-11-010-7-120-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.17 0.06 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.01 (loc) 1 1 33 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 672 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 32-33: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 17-48: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 17-48, 16-49, 15-50, 14-52, 18-47, 19-46, 20-44 REACTIONS.All bearings 38-11-0. (lb) - Max Horz 63=121(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 63, 50, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 46, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34 Max Grav All reactions 250 lb or less at joint(s) 63, 33, 48, 49, 50, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 47, 46, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 14-15=-25/256, 15-16=-25/285, 16-17=-25/297, 17-18=-26/297, 18-19=-27/285, 19-20=-26/256 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 63, 50, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 46, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss GE02 Truss Type GABLE Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216397 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:01 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-mmEDL?qeddO1MaTJkiwqCkvKxmUU_xEpj9q2a7zC0lS Scale: 3/16"=1' Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 3x6 5x6 3x6 3x6 3x6 35-11-0 35-11-0 -1-0-0 1-0-0 17-11-8 17-11-8 35-11-0 17-11-8 36-11-0 1-0-0 0-11-09-10-120-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.16 0.06 0.14 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.01 (loc) 31 31 32 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 584 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 16-46, 15-47, 14-49, 17-45, 18-43 REACTIONS.All bearings 35-11-0. (lb) - Max Horz 60=102(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 60, 32, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33 Max Grav All reactions 250 lb or less at joint(s) 60, 32, 46, 47, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 45, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 14-15=-18/260, 15-16=-19/270, 16-17=-19/270, 17-18=-18/260 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 60, 32, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss GE03 Truss Type GABLE Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216398 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:03 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-i9M_mgru9Eekbucis7yIH9_ZcaxqSeT6ATJ9e0zC0lQ Scale = 1:71.4 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 19 17 16 15 14 13 12188081 5x6 3x8 MT18HS 4x8 3x4 3x4 4x6 3x4 3x4 4x6 10x10 10x10 3x8 MT18HS 5x6 5x6 3-0-0 3-0-0 9-10-0 6-10-0 19-5-8 9-7-8 29-1-0 9-7-8 38-11-0 9-10-0 -1-0-0 1-0-0 6-7-8 6-7-8 13-0-8 6-5-0 19-5-8 6-5-0 25-10-8 6-5-0 32-3-8 6-5-0 38-11-0 6-7-8 39-11-0 1-0-0 0-11-010-7-120-11-06.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-0-14], [2:Edge,0-3-4], [4:0-3-0,0-3-0], [5:0-1-12,0-1-8], [7:0-1-12,0-1-8], [8:0-3-0,0-3-0], [10:0-1-12,0-0-14], [12:Edge,0-3-4], [20:0-1-11,0-1-0], [23:0-1-11,0-1-0], [26:0-1-11,0-1-0], [29:0-1-11,0-1-0], [39:0-1-12,0-1-0], [41:0-1-12,0-1-0], [52:0-1-11,0-1-0], [55:0-1-11,0-1-0], [58:0-1-11,0-1-0], [61:0-1-11,0-1-0], [70:0-1-12,0-1-0], [73:0-1-12,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.60 0.96 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.41 -0.81 0.17 (loc) 13-15 15-17 12 l/defl >999 >528 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 716 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 14-16: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-15,2-19,10-12: 2x4 SPF No.2, 3-19,9-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-14 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-15, 5-15, 3-19, 9-12 REACTIONS.(lb/size)19=1710/3-3-8, 12=1783/0-3-8, 18=87/0-3-8 Max Horz 19=-110(LC 4) Max Uplift 19=-160(LC 6), 12=-115(LC 7) Max Grav 19=1710(LC 1), 12=1783(LC 1), 18=213(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-585/212, 3-4=-2663/368, 4-5=-2581/400, 5-6=-2008/363, 6-7=-2008/363, 7-8=-2616/379, 8-9=-2698/347, 9-10=-668/153, 2-19=-500/205, 10-12=-537/179 BOT CHORD 18-19=-238/2395, 17-18=-238/2395, 17-80=-123/2146, 16-80=-123/2146, 15-16=-123/2146, 14-15=-113/2162, 14-81=-113/2162, 13-81=-113/2162, 12-13=-217/2430 WEBS 6-15=-183/1365, 7-15=-699/194, 7-13=0/461, 5-15=-676/208, 5-17=-20/426, 3-19=-2289/193, 9-12=-2242/230 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are MT20 plates unless otherwise indicated. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 19=160, 12=115. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss GE04 Truss Type GABLE Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216399 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:04 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-BLwMz0sWwYnbD1BuQrTXpMXrMzVtBIZGP72iBSzC0lP Scale = 1:41.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 24 23 22 21 20 19 18 17 16 15 14 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 12-5-0 12-5-0 -0-11-4 0-11-4 6-2-8 6-2-8 12-5-0 6-2-8 13-4-4 0-11-4 1-3-06-5-11-3-010.00 12 Plate Offsets (X,Y)-- [2:0-3-15,0-1-8], [12:0-3-15,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-R 0.15 0.08 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 13 13 14 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 157 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 12-5-0. (lb) - Max Horz 24=-156(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 20, 21, 22, 18, 17, 16 except 24=-154(LC 4), 14=-133(LC 5), 23=-147(LC 5), 15=-132(LC 4) Max Grav All reactions 250 lb or less at joint(s) 24, 14, 19, 20, 21, 22, 23, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 21, 22, 18, 17, 16 except (jt=lb) 24=154, 14=133, 23=147, 15=132. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J01 Truss Type Jack-Open Qty 2 Ply 1 659 West Clay Northlake Job Reference (optional) I37216400 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:04 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-BLwMz0sWwYnbD1BuQrTXpMXs?zWSBKCGP72iBSzC0lP Scale: 1"=1' 1 2 5 3 4 2x4 2x4 1-10-0 1-10-0 -1-0-0 1-0-0 1-10-0 1-10-0 0-11-01-10-01-5-51-10-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.11 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-10-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=156/0-3-8, 3=33/Mechanical, 4=14/Mechanical Max Horz 5=61(LC 6) Max Uplift 5=-27(LC 6), 3=-20(LC 6) Max Grav 5=156(LC 1), 3=33(LC 1), 4=32(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J02 Truss Type Jack-Closed Qty 7 Ply 1 659 West Clay Northlake Job Reference (optional) I37216401 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:05 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-fXUkAMt8hrvSrBm4zY_mMa40bNqBwn7PdnoGjuzC0lO Scale = 1:17.0 1 2 3 5 4 2x4 2x4 3x4 3x4 3-10-0 3-10-0 -1-0-0 1-0-0 3-10-0 3-10-0 0-11-02-10-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.18 0.14 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=221/0-3-8, 4=135/Mechanical Max Horz 5=84(LC 5) Max Uplift 5=-38(LC 6), 4=-22(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J03 Truss Type Jack-Open Qty 2 Ply 1 659 West Clay Northlake Job Reference (optional) I37216402 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:05 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-fXUkAMt8hrvSrBm4zY_mMa40wNsYwnSPdnoGjuzC0lO Scale: 1"=1' 1 2 5 3 4 2x4 2x4 2-6-6 2-6-6 -1-5-0 1-5-0 2-6-6 2-6-6 0-11-01-9-124.24 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.16 0.05 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-6-6 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=215/0-4-9, 3=46/Mechanical, 4=19/Mechanical Max Horz 5=59(LC 6) Max Uplift 5=-56(LC 4), 3=-18(LC 6) Max Grav 5=215(LC 1), 3=46(LC 1), 4=44(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J04 Truss Type Jack-Open Qty 2 Ply 1 659 West Clay Northlake Job Reference (optional) I37216403 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:05 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-fXUkAMt8hrvSrBm4zY_mMa4?fNq8wnSPdnoGjuzC0lO Scale = 1:17.4 1 2 5 3 4 3x4 2x4 4-0-0 4-0-0 -1-0-0 1-0-0 4-0-0 4-0-0 0-11-02-11-02-6-52-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.24 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.01 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=229/0-3-8, 3=102/Mechanical, 4=42/Mechanical Max Horz 5=93(LC 6) Max Uplift 5=-24(LC 6), 3=-48(LC 6) Max Grav 5=229(LC 1), 3=102(LC 1), 4=73(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J05 Truss Type Jack-Open Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216404 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:06 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-7k26OiumS91JSLLHXFW?vncAYn9JfEiZsRXpFLzC0lN Scale = 1:17.4 1 4 2 3 3x4 2x4 4-0-0 4-0-0 4-0-0 4-0-0 0-11-02-11-00-3-82-6-52-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.23 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.02 (loc) 3-4 3-4 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings Mechanical. (lb) - Max Horz 4=69(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2 Max Grav All reactions 250 lb or less at joint(s) 4, 4, 2, 3 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 6) Non Standard bearing condition. Review required. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J06 Truss Type Jack-Open Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216405 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:06 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-7k26OiumS91JSLLHXFW?vncAYn9JfEiZsRXpFLzC0lN Scale = 1:17.4 1 4 2 3 3x4 2x4 4-0-0 4-0-0 4-0-0 4-0-0 0-11-02-11-00-3-82-6-52-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.23 0.14 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 0.02 (loc) 3-4 3-4 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings Mechanical. (lb) - Max Horz 4=69(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2 Max Grav All reactions 250 lb or less at joint(s) 4, 4, 2, 3 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2. 6) Non Standard bearing condition. Review required. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J07 Truss Type Jack-Open Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216406 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:07 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-bwbUb2vPDT9A4VwT5z1ER?9N2BXBOhxi55HMnnzC0lM Scale = 1:11.2 1 2 5 3 4 3x8 2-2-15 2-2-3 -1-2-7 1-2-7 2-2-15 2-2-15 0-10-81-8-00-4-41-3-121-8-04.24 12 Plate Offsets (X,Y)-- [2:0-0-7,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.12 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=186/0-4-15, 3=41/Mechanical, 4=17/Mechanical Max Horz 5=52(LC 6) Max Uplift 5=-48(LC 4), 3=-17(LC 6) Max Grav 5=186(LC 1), 3=41(LC 1), 4=39(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J08 Truss Type Jack-Open Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216407 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:07 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-bwbUb2vPDT9A4VwT5z1ER?9N2BXBOhxi55HMnnzC0lM Scale = 1:11.2 1 2 5 3 4 3x8 2-2-15 2-2-3 -1-2-7 1-2-7 2-2-15 2-2-15 0-10-81-8-00-4-41-3-121-8-04.24 12 Plate Offsets (X,Y)-- [2:0-0-7,0-1-4], [5:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.12 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=186/0-4-15, 3=41/Mechanical, 4=17/Mechanical Max Horz 5=52(LC 6) Max Uplift 5=-48(LC 4), 3=-17(LC 6) Max Grav 5=186(LC 1), 3=41(LC 1), 4=39(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J09 Truss Type Jack-Open Qty 2 Ply 1 659 West Clay Northlake Job Reference (optional) I37216408 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:07 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-bwbUb2vPDT9A4VwT5z1ER?9NDBX6Ohxi55HMnnzC0lM Scale = 1:12.5 1 2 5 3 4 2x4 2x4 2-0-0 2-0-0 -1-0-0 1-0-0 2-0-0 2-0-0 0-11-01-11-01-6-51-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.11 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=161/0-3-8, 3=39/Mechanical, 4=17/Mechanical Max Horz 5=63(LC 6) Max Uplift 5=-27(LC 6), 3=-22(LC 6) Max Grav 5=161(LC 1), 3=39(LC 1), 4=35(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J10 Truss Type Jack-Open Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216409 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:08 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-369tpOv1_mH1ifVffgYT_CiXQbt278BrKl0wKDzC0lL Scale = 1:12.3 1 2 5 3 4 3x8 2-10-11 2-9-15 -1-3-8 1-3-8 2-10-11 2-10-11 0-10-81-10-124.24 12 Plate Offsets (X,Y)-- [2:0-0-10,0-1-12], [5:0-0-0,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.15 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-11 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=216/0-4-15, 3=61/Mechanical, 4=24/Mechanical Max Horz 5=61(LC 6) Max Uplift 5=-52(LC 4), 3=-24(LC 6) Max Grav 5=216(LC 1), 3=61(LC 1), 4=49(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J11 Truss Type Jack-Open Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216410 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:08 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-369tpOv1_mH1ifVffgYT_CiX9bt478BrKl0wKDzC0lL Scale = 1:12.3 1 2 5 3 4 2x4 2x4 2-9-3 2-9-3 -1-5-0 1-5-0 2-9-3 2-9-3 0-11-01-10-124.24 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.16 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=222/0-4-9, 3=55/Mechanical, 4=23/Mechanical Max Horz 5=62(LC 6) Max Uplift 5=-56(LC 4), 3=-22(LC 6) Max Grav 5=222(LC 1), 3=55(LC 1), 4=48(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J12 Truss Type Jack-Open Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216411 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:08 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-369tpOv1_mH1ifVffgYT_CiX9bt178BrKl0wKDzC0lL Scale = 1:12.4 1 2 5 3 4 2x4 2x4 2-9-15 2-9-15 -1-5-0 1-5-0 2-9-15 2-9-15 0-11-01-11-00-4-41-6-121-11-04.24 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.16 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=224/0-4-9, 3=57/Mechanical, 4=23/Mechanical Max Horz 5=62(LC 6) Max Uplift 5=-55(LC 4), 3=-22(LC 6) Max Grav 5=224(LC 1), 3=57(LC 1), 4=49(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J13 Truss Type Jack-Open Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216412 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:09 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-XJjF0kwfl4PuJp4sCO3iWQEiv_DGsbR?YPmTsgzC0lK Scale = 1:12.4 1 2 5 3 4 2x4 2x4 2-9-15 2-9-15 -1-5-0 1-5-0 2-9-15 2-9-15 0-11-01-11-00-4-41-6-121-11-04.24 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.16 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=224/0-4-9, 3=57/Mechanical, 4=23/Mechanical Max Horz 5=62(LC 6) Max Uplift 5=-55(LC 4), 3=-22(LC 6) Max Grav 5=224(LC 1), 3=57(LC 1), 4=49(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J17 Truss Type Jack-Closed Qty 3 Ply 1 659 West Clay Northlake Job Reference (optional) I37216413 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:09 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-XJjF0kwfl4PuJp4sCO3iWQEhA_Bwsb6?YPmTsgzC0lK Scale = 1:17.4 1 2 3 5 4 2x4 2x4 3x4 3x4 4-0-0 4-0-0 -0-11-0 0-11-0 4-0-0 4-0-0 0-11-02-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.21 0.15 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.03 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=221/0-3-8, 4=143/Mechanical Max Horz 5=86(LC 5) Max Uplift 5=-35(LC 6), 4=-23(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J17A Truss Type Jack-Closed Girder Qty 2 Ply 1 659 West Clay Northlake Job Reference (optional) I37216414 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:10 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-?VHdE4xHWOXlxyf2m5ax3dnuqOZjb2E8n3V0O6zC0lJ Scale = 1:12.3 1 2 3 4 7 6 5 2x4 4x6 2x4 3x4 3x4 3x4 2-0-0 2-0-0 4-0-0 2-0-0 -0-11-0 0-11-0 2-0-0 2-0-0 4-0-0 2-0-0 0-11-01-11-06.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.09 0.05 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 7 6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=221/0-3-8, 5=143/Mechanical Max Horz 7=57(LC 4) Max Uplift 7=-39(LC 11), 5=-20(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2 lb down and 15 lb up at 2-0-0 on top chord, and 3 lb up at 2-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 6=1(B) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J18 Truss Type JACK-OPEN Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216415 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:10 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-?VHdE4xHWOXlxyf2m5ax3dnt0OZXb2h8n3V0O6zC0lJ Scale = 1:12.3 1 2 5 3 4 2x4 2x4 2-9-3 2-9-3 -1-3-9 1-3-9 2-9-3 2-9-3 0-11-01-10-120-4-41-6-81-10-124.24 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.14 0.06 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=211/0-4-9, 3=58/Mechanical, 4=24/Mechanical Max Horz 5=60(LC 6) Max Uplift 5=-50(LC 4), 3=-23(LC 6) Max Grav 5=211(LC 1), 3=58(LC 1), 4=49(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J19 Truss Type JACK-OPEN Qty 5 Ply 1 659 West Clay Northlake Job Reference (optional) I37216416 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:10 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-?VHdE4xHWOXlxyf2m5ax3dnuYOZob2h8n3V0O6zC0lJ Scale = 1:12.5 1 2 5 3 4 2x4 2x4 2-0-0 2-0-0 -0-11-0 0-11-0 2-0-0 2-0-0 0-11-01-11-01-6-51-11-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.11 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=153/0-3-8, 3=41/Mechanical, 4=17/Mechanical Max Horz 5=61(LC 6) Max Uplift 5=-23(LC 6), 3=-24(LC 6) Max Grav 5=153(LC 1), 3=41(LC 1), 4=36(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J30 Truss Type JACK-OPEN Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216417 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:11 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-Thr?RPyvHhfcZ6EEKp5AbrK2mov3KVxI0jFawYzC0lI Scale = 1:11.6 1 2 5 3 4 2x4 2x4 2-4-5 2-4-5 -1-3-9 1-3-9 2-4-5 2-4-5 0-11-01-9-04.24 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.14 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-5 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=199/0-4-9, 3=43/Mechanical, 4=18/Mechanical Max Horz 5=56(LC 6) Max Uplift 5=-51(LC 4), 3=-17(LC 6) Max Grav 5=199(LC 1), 3=43(LC 1), 4=41(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J31 Truss Type JACK-OPEN Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216418 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:11 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-Thr?RPyvHhfcZ6EEKp5AbrK2mov3KVxI0jFawYzC0lI Scale = 1:11.6 1 2 5 3 4 2x4 2x4 2-4-5 2-4-5 -1-3-9 1-3-9 2-4-5 2-4-5 0-11-01-9-04.24 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.14 0.04 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-5 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=199/0-4-9, 3=43/Mechanical, 4=18/Mechanical Max Horz 5=56(LC 6) Max Uplift 5=-51(LC 4), 3=-17(LC 6) Max Grav 5=199(LC 1), 3=43(LC 1), 4=41(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 3. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss J32 Truss Type JACK-CLOSED GIRDER Qty 2 Ply 1 659 West Clay Northlake Job Reference (optional) I37216419 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:12 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-yuPNelyX2?nTAGpQuWcP82sE_CFW3yBREN_7T_zC0lH Scale = 1:11.6 1 2 4 3 2x4 2x4 2x4 2x4 1-0-0 1-0-0 1-8-0 1-8-0 2-0-0 0-4-0 0-11-01-9-01-5-80-3-81-9-06.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-0-12], [3:0-1-14,0-0-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.04 0.03 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 4 3-4 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=72/0-3-8, 3=73/0-1-8 Max Horz 4=47(LC 5) Max Uplift 3=-25(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1 lb down and 19 lb up at 1-10-12 on top chord, and 8 lb down and 1 lb up at 1-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 3-4=-20 Concentrated Loads (lb) Vert: 3=-2(F) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss M01 Truss Type Monopitch Qty 6 Ply 1 659 West Clay Northlake Job Reference (optional) I37216420 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:12 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-yuPNelyX2?nTAGpQuWcP82sDBCFl3yBREN_7T_zC0lH Scale = 1:10.8 1 2 3 5 4 2x4 2x4 2x4 2x4 1-4-0 1-4-0 -1-0-0 1-0-0 1-4-0 1-4-0 0-11-01-7-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MR 0.10 0.01 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 1-4-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.(lb/size)4=7/Mechanical, 5=148/0-3-8 Max Horz 5=42(LC 5) Max Uplift 4=-19(LC 5), 5=-49(LC 6) Max Grav 4=20(LC 2), 5=148(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(6-7) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss M02 Truss Type GABLE Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216421 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:13 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-Q4zms5z9pJvKoQNdRE8ehGPK8cVgoIHaT1kh?RzC0lG Scale = 1:24.6 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 8 7 13 18 2x4 4x8 3x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 2x4 2x4 2x4 2x4 3x4 2x4 2x4 4x6 0-1-12 0-1-12 9-11-8 9-9-12 -0-11-0 0-11-0 4-11-12 4-11-12 9-11-8 4-11-12 0-9-04-0-133-9-50-3-84-0-134.00 12 Plate Offsets (X,Y)-- [2:0-5-5,Edge], [6:0-2-0,0-0-12], [7:Edge,0-1-8], [13:0-1-0,0-1-4], [18:0-0-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.34 0.35 0.46 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.08 -0.21 0.01 (loc) 8-21 8-21 2 l/defl >999 >570 n/a L/d 240 180 n/a PLATES MT20 Weight: 90 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 6-7: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 18 REACTIONS.(lb/size)2=450/0-3-8, 7=390/0-1-8 Max Horz 2=121(LC 5) Max Uplift 2=-53(LC 4), 7=-43(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-550/0, 3-4=-490/131 BOT CHORD 2-8=-99/503, 7-8=-99/503 WEBS 4-13=-515/151, 13-18=-506/179, 7-18=-529/160 NOTES-(9-10) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable studs spaced at 1-4-0 oc. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss M03 Truss Type MONOPITCH Qty 16 Ply 1 659 West Clay Northlake Job Reference (optional) I37216422 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:13 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-Q4zms5z9pJvKoQNdRE8ehGPH_cTWoK1aT1kh?RzC0lG Scale = 1:24.6 1 2 3 4 5 6 2x4 6x8 3x4 2x4 6x6 9-11-8 9-9-12 -1-0-0 1-0-0 4-11-12 4-11-12 9-11-8 4-11-12 0-9-04-0-133-9-50-3-84-0-134.00 12 Plate Offsets (X,Y)-- [6:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.54 0.49 0.35 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.21 -0.53 0.03 (loc) 6-9 6-9 2 l/defl >552 >223 n/a L/d 240 180 n/a PLATES MT20 Weight: 34 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-6: 2x3 SPF No.2 SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-4-1 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=456/0-3-8, 6=389/0-1-8 Max Horz 2=121(LC 5) Max Uplift 2=-56(LC 4), 6=-43(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-872/0, 3-4=-467/158 BOT CHORD 2-6=-122/485 WEBS 4-6=-495/193 NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T01 Truss Type Hip Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216423 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:14 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-uGX83R_oac1BQayp?xftDTyPK?ngXn_kihTEXtzC0lF Scale = 1:39.2 1 2 3 4 5 6 7 12 11 10 9 8 4x6 4x6 10x10 3x6 3x8 3x4 3x8 10x10 5-10-0 5-10-0 16-5-0 10-7-0 22-3-0 5-10-0 -1-0-0 1-0-0 5-10-0 5-10-0 11-1-8 5-3-8 16-5-0 5-3-8 22-3-0 5-10-0 23-3-0 1-0-0 0-11-03-10-00-11-03-10-06.00 12 Plate Offsets (X,Y)-- [8:Edge,0-7-13], [8:0-1-12,0-0-0], [12:0-1-12,0-0-0], [12:Edge,0-7-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.76 0.62 0.36 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.23 -0.63 0.03 (loc) 9-11 9-11 8 l/defl >999 >420 n/a L/d 240 180 n/a PLATES MT20 Weight: 80 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-12,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-15 oc purlins, except end verticals, and 2-0-0 oc purlins (5-4-3 max.): 3-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)12=947/0-3-8, 8=947/0-3-8 Max Horz 12=-43(LC 4) Max Uplift 12=-53(LC 6), 8=-53(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1312/137, 3-4=-1110/151, 4-5=-1110/151, 5-6=-1312/137, 2-12=-906/167, 6-8=-906/167 BOT CHORD 11-12=-93/267, 10-11=-82/1361, 9-10=-82/1361, 8-9=-61/267 WEBS 3-11=0/341, 4-11=-369/121, 4-9=-369/121, 5-9=0/341, 2-11=0/834, 6-9=0/834 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T02 Truss Type Hip Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216424 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:14 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-uGX83R_oac1BQayp?xftDTyP8?o3XpWkihTEXtzC0lF Scale = 1:39.2 1 2 3 4 5 6 11 10 9 8 7 4x8 4x6 6x10 3x6 3x4 3x8 6x10 7-10-0 7-10-0 14-5-0 6-7-0 22-3-0 7-10-0 -1-0-0 1-0-0 7-10-0 7-10-0 14-5-0 6-7-0 22-3-0 7-10-0 23-3-0 1-0-0 0-11-04-10-00-11-04-10-06.00 12 Plate Offsets (X,Y)-- [3:0-5-0,0-2-0], [4:0-3-4,0-2-0], [7:0-7-9,0-3-0], [7:0-0-0,0-1-12], [11:0-0-0,0-1-12], [11:0-7-9,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.71 0.54 0.20 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.11 -0.27 0.03 (loc) 7-8 7-8 7 l/defl >999 >963 n/a L/d 240 180 n/a PLATES MT20 Weight: 82 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,5-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-14 oc purlins, except end verticals, and 2-0-0 oc purlins (5-2-9 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)11=947/0-3-8, 7=947/0-3-8 Max Horz 11=-53(LC 4) Max Uplift 11=-64(LC 6), 7=-64(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1242/160, 3-4=-1012/182, 4-5=-1242/160, 2-11=-871/195, 5-7=-870/196 BOT CHORD 10-11=-158/531, 9-10=-158/531, 8-9=-2/1010, 7-8=-128/533 WEBS 4-8=0/252, 2-9=-15/589, 5-8=-19/587 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T03 Truss Type Hip Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216425 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:15 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-MS4WHn?QKw921kX?ZeA6mhUdPP6UGGYtxLDn3JzC0lE Scale = 1:39.2 1 2 3 4 5 6 7 8 9 10 13 12 11 4x6 4x6 8x10 4x6 5x12 2x4 3x4 2x4 8x10 4x6 9-10-0 9-10-0 12-5-0 2-7-0 22-3-0 9-10-0 -1-0-0 1-0-0 5-0-4 5-0-4 9-10-0 4-9-12 12-5-0 2-7-0 17-2-12 4-9-12 22-3-0 5-0-4 23-3-0 1-0-0 0-11-05-10-00-11-05-10-06.00 12 Plate Offsets (X,Y)-- [6:0-4-4,0-2-0], [12:0-0-0,0-1-12], [12:0-2-12,0-3-0], [13:0-1-4,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.55 0.65 0.22 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.16 -0.39 0.06 (loc) 11-20 11-20 9 l/defl >999 >679 n/a L/d 240 180 n/a PLATES MT20 Weight: 84 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-3 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=950/0-3-8, 9=950/0-3-8 Max Horz 2=59(LC 6) Max Uplift 2=-69(LC 6), 9=-69(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-612/0, 3-4=-1297/218, 4-5=-1069/176, 5-6=-901/187, 6-7=-1068/176, 7-8=-1296/218, 8-9=-617/0 BOT CHORD 2-13=-103/1096, 12-13=0/900, 11-12=0/900, 9-11=-103/1096 WEBS 4-13=-254/129, 5-13=0/276, 6-11=0/276, 7-11=-255/129 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T04 Truss Type Hip Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216426 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:16 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-qfeuU7025EHuft6C7MhLIu1lMpWW?jK19_yLcmzC0lD Scale = 1:35.4 1 2 3 4 5 6 11 10 9 8 7 4x8 4x8 10x10 3x6 3x4 3x8 10x10 6-0-0 6-0-0 13-11-0 7-11-0 19-11-0 6-0-0 -1-0-0 1-0-0 6-0-0 6-0-0 13-11-0 7-11-0 19-11-0 6-0-0 20-11-0 1-0-0 0-11-03-11-00-11-03-11-06.00 12 Plate Offsets (X,Y)-- [3:0-5-0,0-2-0], [4:0-5-0,0-2-0], [7:Edge,0-7-13], [7:0-1-12,0-0-0], [11:0-1-12,0-0-0], [11:Edge,0-7-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.72 0.41 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.20 0.02 (loc) 8-9 8-9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,5-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc purlins, except end verticals, and 2-0-0 oc purlins (4-4-7 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-8 REACTIONS.(lb/size)11=854/0-3-8, 7=854/0-3-8 Max Horz 11=-44(LC 4) Max Uplift 11=-55(LC 6), 7=-55(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1138/137, 3-4=-951/152, 4-5=-1139/138, 2-11=-800/167, 5-7=-799/167 BOT CHORD 8-9=-5/947 WEBS 2-9=-23/719, 5-8=-27/717 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T05 Truss Type Common Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216427 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:16 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-qfeuU7025EHuft6C7MhLIu1oXpRG?ht19_yLcmzC0lD Scale = 1:41.2 1 2 3 4 5 6 7 8 9 10 8x10 4x6 4x6 5x12 2x4 2x4 8x10 4x6 11-1-8 11-1-8 22-3-0 11-1-8 -1-0-0 1-0-0 5-8-0 5-8-0 11-1-8 5-5-8 16-7-0 5-5-8 22-3-0 5-8-0 23-3-0 1-0-0 0-11-06-5-120-11-06.00 12 Plate Offsets (X,Y)-- [10:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.52 0.74 0.34 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.47 0.06 (loc) 10-13 10-13 8 l/defl >999 >564 n/a L/d 240 180 n/a PLATES MT20 Weight: 77 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-4 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=950/0-3-8, 8=950/0-3-8 Max Horz 2=65(LC 6) Max Uplift 2=-74(LC 6), 8=-74(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-679/0, 3-4=-1289/226, 4-5=-1012/174, 5-6=-1012/174, 6-7=-1289/226, 7-8=-679/0 BOT CHORD 2-10=-104/1090, 8-10=-104/1090 WEBS 5-10=-18/565, 6-10=-326/153, 4-10=-326/153 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T06 Truss Type Common Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216428 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:17 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-IrCGiT0gsXPlH1hOg3Car6azDDnUk71AOeiu8CzC0lC Scale = 1:40.7 1 2 3 4 5 6 7 8 9 8x10 4x6 4x6 5x12 2x4 2x4 8x10 4x6 11-1-8 11-1-8 22-3-0 11-1-8 5-8-0 5-8-0 11-1-8 5-5-8 16-7-0 5-5-8 22-3-0 5-8-0 23-3-0 1-0-0 0-11-06-5-120-11-06.00 12 Plate Offsets (X,Y)-- [9:0-6-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.53 0.75 0.35 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.19 -0.48 0.06 (loc) 9-12 9-12 7 l/defl >999 >560 n/a L/d 240 180 n/a PLATES MT20 Weight: 76 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-2 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=889/0-3-8, 7=951/0-3-8 Max Horz 1=-74(LC 7) Max Uplift 1=-42(LC 6), 7=-74(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-702/0, 2-3=-1296/228, 3-4=-1016/175, 4-5=-1015/175, 5-6=-1292/227, 6-7=-678/0 BOT CHORD 1-9=-107/1097, 7-9=-105/1092 WEBS 4-9=-19/566, 5-9=-326/153, 3-9=-332/155 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T07 Truss Type Hip Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216429 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:18 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-m1mfvp1IdrXcuBGaEnjpOJ6AOdCtTesKdIRSgezC0lB Scale = 1:35.4 1 2 3 4 5 6 7 8 11 10 9 4x8 4x6 5x12 4x6 3x6 2x4 3x4 5x12 4x6 8-0-0 8-0-0 11-11-0 3-11-0 19-11-0 8-0-0 -1-0-0 1-0-0 8-0-0 8-0-0 11-11-0 3-11-0 19-11-0 8-0-0 20-11-0 1-0-0 0-11-04-11-00-11-04-11-06.00 12 Plate Offsets (X,Y)-- [2:0-7-1,Edge], [4:0-5-0,0-2-0], [7:0-7-1,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.43 0.42 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.21 0.03 (loc) 11-14 11-14 2 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-5 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=857/0-3-8, 7=857/0-3-8 Max Horz 2=51(LC 6) Max Uplift 2=-62(LC 6), 7=-62(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-322/149, 3-4=-1060/157, 4-5=-861/181, 5-6=-1061/157, 6-7=-321/150 BOT CHORD 2-11=-18/858, 10-11=-17/860, 9-10=-17/860, 7-9=-18/858 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T08 Truss Type HIP GIRDER Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216430 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:19 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-EEK1682wO9fTWLrnoUE2wXfJU0SPCvqTryB?C5zC0lA Scale = 1:27.5 1 2 3 4 5 6 7 8 9 12 11 1021222324 5x6 5x6 5x12 3x4 5x12 3x4 2x4 5x8 2x4 2x4 2-0-0 2-0-0 7-5-8 5-5-8 12-11-0 5-5-8 14-11-0 2-0-0 -0-11-0 0-11-0 2-0-0 2-0-0 7-5-8 5-5-8 12-11-0 5-5-8 14-11-0 2-0-0 15-10-0 0-11-0 0-11-01-9-111-11-00-11-01-9-116.00 12 Plate Offsets (X,Y)-- [2:0-7-1,Edge], [4:0-3-4,0-1-0], [6:0-3-4,0-1-0], [8:0-7-1,Edge], [11:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.54 0.72 0.84 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.13 -0.29 0.01 (loc) 11 11 8 l/defl >999 >609 n/a L/d 240 180 n/a PLATES MT20 Weight: 64 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-6 oc purlins, except 2-0-0 oc purlins (3-1-10 max.): 4-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1013/0-3-8, 8=1013/0-3-8 Max Horz 2=21(LC 5) Max Uplift 2=-150(LC 4), 8=-150(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-609/116, 3-4=-1505/260, 4-5=-2779/489, 5-6=-2779/489, 6-7=-1505/260, 7-8=-609/116 BOT CHORD 2-12=-218/1325, 12-21=-218/1311, 21-22=-218/1311, 11-22=-218/1311, 11-23=-212/1311, 23-24=-212/1311, 10-24=-212/1311, 8-10=-212/1325 WEBS 4-11=-277/1534, 5-11=-390/121, 6-11=-277/1534 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=150, 8=150. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 53 lb down and 37 lb up at 1-8-12, 123 lb down and 32 lb up at 3-8-12, 123 lb down and 35 lb up at 5-8-12, 123 lb down and 35 lb up at 7-5-8, 123 lb down and 35 lb up at 9-2-4, and 123 lb down and 32 lb up at 11-2-4, and 53 lb down and 37 lb up at 13-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 6-9=-60, 13-17=-20 Continued on page 2 May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T08 Truss Type HIP GIRDER Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216430 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:19 2019 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-EEK1682wO9fTWLrnoUE2wXfJU0SPCvqTryB?C5zC0lA LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 12=-53 11=-123(F) 10=-53 21=-123(F) 22=-123(F) 23=-123(F) 24=-123(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T09 Truss Type HIP Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216431 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:20 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-jQuPKU3Z9SoK8VQzMCmHTkBV1Qv3xWfc4cwYlXzC0l9 Scale = 1:26.8 1 2 3 4 5 9 8 7 6 4x8 4x6 3x6 2x4 2x4 3x4 3x8 3x4 4-0-0 4-0-0 10-11-0 6-11-0 14-11-0 4-0-0 -0-11-0 0-11-0 4-0-0 4-0-0 10-11-0 6-11-0 14-11-0 4-0-0 0-11-02-9-52-11-00-11-02-9-56.00 12 Plate Offsets (X,Y)-- [2:0-1-12,0-1-8], [3:0-4-0,0-0-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.49 0.31 0.22 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.06 -0.16 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-9,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (5-9-13 max.): 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=651/0-3-8, 6=583/0-3-8 Max Horz 9=45(LC 5) Max Uplift 9=-45(LC 6), 6=-11(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-834/114, 3-4=-724/130, 4-5=-844/117, 2-9=-625/136, 5-6=-554/91 BOT CHORD 7-8=-46/711 WEBS 2-8=-18/652, 5-7=-31/653 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T10 Truss Type ROOF SPECIAL Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216432 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:20 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-jQuPKU3Z9SoK8VQzMCmHTkBStQodxPcc4cwYlXzC0l9 Scale = 1:44.5 1 2 3 4 5 6 7 8 14 13 12 11 10 9 4x6 6x6 4x6 6x10 3x8 4x8 2x4 3x8 3x6 2x4 4x6 7-5-8 7-5-8 16-1-0 8-7-8 21-3-0 5-2-0 25-3-0 4-0-0 -0-11-0 0-11-0 7-5-8 7-5-8 10-11-0 3-5-8 16-1-0 5-2-0 21-3-0 5-2-0 25-3-0 4-0-0 26-2-0 0-11-0 0-11-02-9-54-7-120-11-02-9-56.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-0-12], [7:0-2-15,0-2-0], [10:0-2-8,0-1-8], [11:0-2-0,0-1-8], [14:0-7-9,0-3-0], [14:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.69 0.72 0.68 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.48 0.06 (loc) 11-13 11-13 9 l/defl >999 >619 n/a L/d 240 180 n/a PLATES MT20 Weight: 91 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-14,7-9: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-10 oc purlins, except end verticals, and 2-0-0 oc purlins (3-4-7 max.): 4-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)14=1062/0-3-8, 9=1062/0-3-8 Max Horz 14=52(LC 5) Max Uplift 14=-57(LC 6), 9=-106(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1489/181, 3-4=-1450/198, 4-5=-2392/281, 5-6=-2392/281, 6-7=-1487/172, 2-14=-995/199, 7-9=-1019/174 BOT CHORD 13-14=-151/506, 12-13=-212/2377, 11-12=-212/2377, 10-11=-68/1294 WEBS 3-13=-41/953, 4-13=-1408/226, 5-11=-401/121, 6-11=-115/1221, 2-13=0/801, 7-10=-64/1144 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14 except (jt=lb) 9=106. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T11 Truss Type Common Qty 5 Ply 1 659 West Clay Northlake Job Reference (optional) I37216433 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:21 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-BcSnXq3BwmwBlf?9vvHW?ykeCq9ignCmJGg6HzzC0l8 Scale = 1:67.3 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 111819 3x6 5x6 3x6 3x8 4x8 3x4 3x4 4x6 3x4 3x4 4x6 10x10 10x10 3x8 9-10-0 9-10-0 19-5-8 9-7-8 29-1-0 9-7-8 38-11-0 9-10-0 -1-0-0 1-0-0 6-7-8 6-7-8 13-0-8 6-5-0 19-5-8 6-5-0 25-10-8 6-5-0 32-3-8 6-5-0 38-11-0 6-7-8 0-11-010-7-120-11-06.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-4], [2:0-1-12,0-0-14], [5:0-1-12,0-1-8], [7:0-1-12,0-1-8], [10:0-1-12,0-0-14], [11:Edge,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.59 0.66 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.36 -0.66 0.14 (loc) 12-14 12-14 11 l/defl >999 >698 n/a L/d 240 180 n/a PLATES MT20 Weight: 157 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-14,2-17,10-11: 2x4 SPF No.2, 4-17,8-11: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-14, 5-14, 4-17 2 Rows at 1/3 pts 8-11 REACTIONS.(lb/size)17=1791/0-3-8, 11=1720/Mechanical Max Horz 17=122(LC 5) Max Uplift 17=-111(LC 6), 11=-74(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-680/139, 3-4=-526/156, 4-5=-2715/371, 5-6=-2020/357, 6-7=-2019/357, 7-8=-2723/374, 8-9=-407/112, 9-10=-550/93, 2-17=-542/181, 10-11=-397/106 BOT CHORD 16-17=-241/2444, 16-18=-138/2174, 15-18=-138/2174, 14-15=-138/2174, 13-14=-138/2175, 13-19=-138/2175, 12-19=-138/2175, 11-12=-247/2459 WEBS 6-14=-177/1373, 7-14=-703/193, 7-12=-1/477, 5-14=-702/193, 5-16=0/466, 4-17=-2247/220, 8-11=-2389/268 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except (jt=lb) 17=111. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T12 Truss Type Roof Special Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216434 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:22 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-fp?9lA4ph422NoZLTdolY9HqYEXAPGWvYwPfpPzC0l7 Scale = 1:75.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 24 23 22 21 20 19 18 17 16 153334 3x6 5x6 3x6 3x12 4x6 3x6 2x4 4x6 2x4 2x4 3x6 3x4 2x4 3x8 3x4 5x8 4x8 5x8 3x4 3x4 2x4 4x10 4x6 5-6-3 5-6-3 10-9-13 5-3-11 15-11-12 5-1-15 16-1-8 0-1-12 18-0-1 1-10-9 18-0-7 0-0-6 25-10-8 7-10-1 32-3-8 6-5-0 38-11-0 6-7-8 -1-0-0 1-0-0 5-6-3 5-6-3 10-9-13 5-3-11 16-1-8 5-3-11 18-0-1 1-10-9 19-5-8 1-5-7 25-10-8 6-5-0 32-3-8 6-5-0 38-11-0 6-7-8 0-11-010-7-120-11-03-0-06.00 12 Plate Offsets (X,Y)-- [2:0-7-1,Edge], [4:0-1-12,0-1-8], [6:0-1-12,0-1-8], [10:0-1-12,0-1-8], [14:0-7-1,Edge], [19:0-3-4,0-2-8], [20:0-4-8,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.55 0.52 0.84 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.12 -0.25 -0.04 (loc) 15-16 16-18 18 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 183 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 7-21,8-18: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 9-16: 2x4 SPF No.2 SLIDER Left 2x6 SPF No.2 1-6-0, Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-3-8 oc purlins. BOT CHORD Structural wood sheathing directly applied or 4-7-5 oc bracing. WEBS 1 Row at midpt 16-19, 9-19 REACTIONS.All bearings 0-3-8 except (jt=length) 18=0-4-3, 14=Mechanical. (lb) - Max Horz 2=113(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 21, 14 Max Grav All reactions 250 lb or less at joint(s) except 2=616(LC 10), 21=710(LC 1), 18=1189(LC 1), 14=815(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-708/169, 4-5=-349/147, 5-6=-282/173, 6-7=0/392, 7-8=0/330, 8-9=0/352, 9-10=-705/333, 10-11=-1016/334, 11-12=-1171/303, 12-13=-1174/215, 13-14=-252/0 BOT CHORD 2-24=-115/579, 23-24=-115/579, 22-23=-115/579, 20-21=-668/126, 7-20=-267/76, 19-20=-297/141, 18-19=-1132/109, 16-33=-10/564, 33-34=-10/564, 15-34=-10/564, 14-15=-117/977 WEBS 4-22=-392/100, 6-22=0/289, 20-22=-49/294, 6-20=-581/161, 9-19=-1122/120, 9-16=-264/1126, 10-16=-673/273, 10-15=-160/626, 12-15=-333/189 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 21, 14. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T13 Truss Type Common Qty 3 Ply 1 659 West Clay Northlake Job Reference (optional) I37216435 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:23 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-7?ZYyW5RSNAv?y8Y1KJ_5Np_ierA8hi3ma9DLszC0l6 Scale = 1:67.3 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 111819 3x6 5x6 3x6 3x8 4x8 3x4 3x4 4x6 3x4 3x4 4x6 10x10 10x10 3x8 9-10-0 9-10-0 19-5-8 9-7-8 29-1-0 9-7-8 38-11-0 9-10-0 -1-0-0 1-0-0 6-7-8 6-7-8 13-0-8 6-5-0 19-5-8 6-5-0 25-10-8 6-5-0 32-3-8 6-5-0 38-11-0 6-7-8 0-11-010-7-120-11-06.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-4], [2:0-1-12,0-0-14], [5:0-1-12,0-1-8], [7:0-1-12,0-1-8], [10:0-1-12,0-0-14], [11:Edge,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.59 0.66 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.36 -0.66 0.14 (loc) 12-14 12-14 11 l/defl >999 >698 n/a L/d 240 180 n/a PLATES MT20 Weight: 157 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-14,2-17,10-11: 2x4 SPF No.2, 4-17,8-11: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-14, 5-14, 4-17 2 Rows at 1/3 pts 8-11 REACTIONS.(lb/size)17=1791/0-3-8, 11=1720/Mechanical Max Horz 17=122(LC 5) Max Uplift 17=-111(LC 6), 11=-74(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-680/139, 3-4=-526/156, 4-5=-2715/371, 5-6=-2020/357, 6-7=-2019/357, 7-8=-2723/374, 8-9=-407/112, 9-10=-550/93, 2-17=-542/181, 10-11=-397/106 BOT CHORD 16-17=-241/2444, 16-18=-138/2174, 15-18=-138/2174, 14-15=-138/2174, 13-14=-138/2175, 13-19=-138/2175, 12-19=-138/2175, 11-12=-247/2459 WEBS 6-14=-177/1373, 7-14=-703/193, 7-12=-1/477, 5-14=-702/193, 5-16=0/466, 4-17=-2247/220, 8-11=-2389/268 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except (jt=lb) 17=111. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T14 Truss Type Common Qty 3 Ply 1 659 West Clay Northlake Job Reference (optional) I37216436 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:24 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-bB7wAs63DhImc6jkb1qDdaM6N1BPtAYC?EumuIzC0l5 Scale = 1:66.8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 101718 3x6 5x6 3x6 3x8 4x8 3x4 3x4 4x6 3x4 3x4 4x6 10x10 10x10 3x8 9-10-0 9-10-0 19-5-8 9-7-8 29-1-0 9-7-8 38-11-0 9-10-0 6-7-8 6-7-8 13-0-8 6-5-0 19-5-8 6-5-0 25-10-8 6-5-0 32-3-8 6-5-0 38-11-0 6-7-8 0-11-010-7-120-11-06.00 12 Plate Offsets (X,Y)-- [1:Edge,0-3-8], [1:0-1-12,0-0-14], [4:0-1-12,0-1-8], [6:0-1-12,0-1-8], [9:0-1-12,0-0-14], [10:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.79 0.66 0.87 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.37 -0.67 0.14 (loc) 11-13 11-13 10 l/defl >999 >696 n/a L/d 240 180 n/a PLATES MT20 Weight: 156 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 5-13: 2x4 SPF No.2, 1-16,3-16,9-10,7-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-7 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-13, 4-13 2 Rows at 1/3 pts 3-16, 7-10 REACTIONS.(lb/size)16=1721/Mechanical, 10=1721/Mechanical Max Horz 16=114(LC 5) Max Uplift 16=-74(LC 6), 10=-74(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-539/92, 2-3=-398/111, 3-4=-2725/375, 4-5=-2021/357, 5-6=-2021/357, 6-7=-2725/375, 7-8=-398/111, 8-9=-539/92, 1-16=-391/105, 9-10=-391/105 BOT CHORD 15-16=-248/2461, 15-17=-139/2177, 14-17=-139/2177, 13-14=-139/2177, 12-13=-139/2177, 12-18=-139/2177, 11-18=-139/2177, 10-11=-248/2461 WEBS 5-13=-177/1374, 6-13=-703/193, 6-11=-0/478, 4-13=-703/193, 4-15=-0/478, 3-16=-2403/270, 7-10=-2403/270 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T15 Truss Type Common Qty 4 Ply 1 659 West Clay Northlake Job Reference (optional) I37216437 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:25 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-3OhINC6h_?QdEGIw8lLSAovKCRWecbCMEueJQkzC0l4 Scale = 1:67.3 1 2 3 4 5 6 7 8 9 10 17 16 15 14 13 12 111819 3x6 5x6 3x6 3x8 4x8 3x4 3x4 4x6 3x4 3x4 4x6 10x10 10x10 3x8 9-10-0 9-10-0 19-5-8 9-7-8 29-1-0 9-7-8 38-11-0 9-10-0 6-7-8 6-7-8 13-0-8 6-5-0 19-5-8 6-5-0 25-10-8 6-5-0 32-3-8 6-5-0 38-11-0 6-7-8 39-11-0 1-0-0 0-11-010-7-120-11-06.00 12 Plate Offsets (X,Y)-- [1:Edge,0-3-4], [1:0-1-12,0-0-14], [4:0-1-12,0-1-8], [6:0-1-12,0-1-8], [9:0-1-12,0-0-14], [11:Edge,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.59 0.66 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.36 -0.66 0.14 (loc) 14-16 14-16 11 l/defl >999 >698 n/a L/d 240 180 n/a PLATES MT20 Weight: 157 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 5-14,1-17,9-11: 2x4 SPF No.2, 3-17,7-11: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-14, 4-14, 7-11 2 Rows at 1/3 pts 3-17 REACTIONS.(lb/size)17=1720/0-3-8, 11=1791/0-3-8 Max Horz 17=-122(LC 4) Max Uplift 17=-74(LC 6), 11=-111(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-550/93, 2-3=-407/112, 3-4=-2723/374, 4-5=-2019/357, 5-6=-2020/357, 6-7=-2715/371, 7-8=-526/156, 8-9=-680/139, 1-17=-397/106, 9-11=-542/180 BOT CHORD 16-17=-216/2459, 16-18=-107/2175, 15-18=-107/2175, 14-15=-107/2175, 13-14=-107/2174, 13-19=-107/2174, 12-19=-107/2174, 11-12=-210/2444 WEBS 5-14=-177/1373, 6-14=-702/193, 6-12=0/466, 4-14=-703/193, 4-16=-1/477, 3-17=-2389/268, 7-11=-2247/220 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17 except (jt=lb) 11=111. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T16 Truss Type Common Qty 4 Ply 1 659 West Clay Northlake Job Reference (optional) I37216438 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:25 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-3OhINC6h_?QdEGIw8lLSAovKCRWfcbDMEueJQkzC0l4 Scale = 1:67.9 1 2 3 4 5 6 7 8 9 10 11 18 17 16 15 14 13 121920 3x6 5x6 3x6 3x8 4x8 3x4 3x4 4x6 3x4 3x4 4x6 10x10 10x10 3x8 9-10-0 9-10-0 19-5-8 9-7-8 29-1-0 9-7-8 38-11-0 9-10-0 -1-0-0 1-0-0 6-7-8 6-7-8 13-0-8 6-5-0 19-5-8 6-5-0 25-10-8 6-5-0 32-3-8 6-5-0 38-11-0 6-7-8 39-11-0 1-0-0 0-11-010-7-120-11-06.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-4], [2:0-1-12,0-0-14], [5:0-1-12,0-1-8], [7:0-1-12,0-1-8], [10:0-1-12,0-0-14], [12:Edge,0-3-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.59 0.66 0.97 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.36 -0.66 0.14 (loc) 13-15 13-15 12 l/defl >999 >704 n/a L/d 240 180 n/a PLATES MT20 Weight: 159 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 6-15,2-18,10-12: 2x4 SPF No.2, 4-18,8-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 7-15, 5-15, 4-18, 8-12 REACTIONS.(lb/size)18=1790/0-3-8, 12=1790/0-3-8 Max Horz 18=110(LC 5) Max Uplift 18=-111(LC 6), 12=-111(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-680/139, 3-4=-526/156, 4-5=-2713/370, 5-6=-2017/356, 6-7=-2017/356, 7-8=-2713/370, 8-9=-526/156, 9-10=-680/139, 2-18=-542/180, 10-12=-542/180 BOT CHORD 17-18=-210/2443, 17-19=-106/2173, 16-19=-106/2173, 15-16=-106/2173, 14-15=-106/2173, 14-20=-106/2173, 13-20=-106/2173, 12-13=-210/2443 WEBS 6-15=-177/1373, 7-15=-702/193, 7-13=0/467, 5-15=-702/193, 5-17=0/467, 4-18=-2245/219, 8-12=-2245/219 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 18=111, 12=111. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T17 Truss Type Common Qty 8 Ply 1 659 West Clay Northlake Job Reference (optional) I37216439 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:27 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-?mp2ou8yWcgLTaSJGAOwFD_apFBO4dVehC7QVdzC0l2 Scale = 1:66.3 1 2 3 4 5 6 7 8 9 10 11 12 13 18 17 16 15 1427282930 3x8 5x6 3x8 8x10 4x8 3x6 4x8 3x4 3x4 2x4 3x4 3x4 2x4 8x10 4x8 3x6 9-1-0 9-1-0 17-11-8 8-10-8 26-10-0 8-10-8 35-11-0 9-1-0 -1-0-0 1-0-0 6-1-8 6-1-8 12-0-8 5-11-0 17-11-8 5-11-0 23-10-8 5-11-0 29-9-8 5-11-0 35-11-0 6-1-8 36-11-0 1-0-0 0-11-09-10-120-11-06.00 12 Plate Offsets (X,Y)-- [6:0-1-12,0-1-8], [8:0-1-12,0-1-8], [16:0-4-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.90 0.71 0.47 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.35 -0.68 0.17 (loc) 16-18 16-18 12 l/defl >999 >634 n/a L/d 240 180 n/a PLATES MT20 Weight: 137 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-5,9-13: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 SLIDER Left 2x6 SPF No.2 2-0-0, Right 2x6 SPF No.2 2-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 8-16, 6-16 REACTIONS.(lb/size)2=1643/0-3-8, 12=1643/0-3-8 Max Horz 2=97(LC 6) Max Uplift 2=-101(LC 6), 12=-101(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-358/87, 3-4=-2597/342, 4-5=-2427/316, 5-6=-2384/341, 6-7=-1859/331, 7-8=-1859/331, 8-9=-2384/341, 9-10=-2427/316, 10-11=-2597/342, 11-12=-358/87 BOT CHORD 2-18=-203/2218, 18-27=-116/1995, 27-28=-116/1995, 17-28=-116/1995, 16-17=-116/1995, 15-16=-116/1995, 15-29=-116/1995, 29-30=-116/1995, 14-30=-116/1995, 12-14=-203/2218 WEBS 7-16=-168/1280, 8-16=-646/181, 8-14=0/373, 6-16=-646/181, 6-18=0/373 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=101, 12=101. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T18 Truss Type Common Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216440 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:27 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-?mp2ou8yWcgLTaSJGAOwFD_eEFEZ4hzehC7QVdzC0l2 Scale = 1:36.2 1 2 3 4 5 6 9 8 7 2x4 3x6 4x6 2x4 5x6 3x8 6x10 4x6 7-0-8 7-0-8 17-0-0 9-11-8 7-0-8 7-0-8 11-11-0 4-10-8 17-0-0 5-1-0 18-0-0 1-0-0 2-4-85-10-120-11-06.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.68 0.57 0.25 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.15 -0.36 0.02 (loc) 7-12 7-12 5 l/defl >999 >564 n/a L/d 240 180 n/a PLATES MT20 Weight: 62 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-9: 2x4 SPF-S Stud SLIDER Right 2x6 SPF No.2 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-8-12 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=672/Mechanical, 5=736/0-3-8 Max Horz 9=-97(LC 4) Max Uplift 9=-23(LC 6), 5=-67(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-689/123, 2-3=-659/133, 3-4=-903/173, 4-5=-624/0, 1-9=-614/116 BOT CHORD 5-7=-63/758 WEBS 2-7=0/309, 3-7=-298/127, 1-7=0/479 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 5. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss T19 Truss Type Half Hip Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216441 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:28 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-UzNR?D9aHwoB5j1Vqtv9oQXwAfhvpBIowssz13zC0l1 Scale = 1:20.2 1 2 3 4 7 6 5 4x6 2x4 2x4 2x4 3x4 3x4 4-1-8 4-1-8 5-6-0 1-4-8 -0-11-4 0-11-4 4-1-8 4-1-8 5-6-0 1-4-8 0-11-02-11-126.00 12 Plate Offsets (X,Y)-- [3:0-4-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.22 0.12 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 21 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)7=282/0-3-8, 5=203/Mechanical Max Horz 7=91(LC 5) Max Uplift 7=-42(LC 6), 5=-22(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 5. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG01 Truss Type Hip Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216442 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:29 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-y9xpDZAC1Dw2jtciNbQOKe3zg2wiYP?x9WcXZVzC0l0 Scale = 1:39.2 1 2 3 4 5 6 7 8 9 13 12 11 10222324252627 5x12 5x12 8x10 3x6 4x8 2x4 6x16 2x4 2x4 8x10 3x6 3-10-0 3-10-0 11-1-8 7-3-8 18-5-0 7-3-8 22-3-0 3-10-0 -1-0-0 1-0-0 3-10-0 3-10-0 11-1-8 7-3-8 18-5-0 7-3-8 22-3-0 3-10-0 23-3-0 1-0-0 0-11-02-10-00-11-02-10-06.00 12 Plate Offsets (X,Y)-- [4:0-9-8,0-2-4], [6:0-9-8,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.75 0.53 0.99 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.42 0.04 (loc) 11-13 11-13 8 l/defl >999 >633 n/a L/d 240 180 n/a PLATES MT20 Weight: 104 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-6: 2x4 SPF 2100F 1.8E BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-12 oc purlins, except 2-0-0 oc purlins (3-2-15 max.): 4-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1549/0-3-8, 8=1501/0-3-8 Max Horz 2=31(LC 13) Max Uplift 2=-209(LC 5), 8=-195(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1180/193, 3-4=-2467/397, 4-5=-3745/626, 5-6=-3745/626, 6-7=-2367/368, 7-8=-1141/181 BOT CHORD 2-13=-331/2149, 13-22=-333/2169, 12-22=-333/2169, 12-23=-333/2169, 23-24=-333/2169, 11-24=-333/2169, 11-25=-290/2077, 25-26=-290/2077, 26-27=-290/2077, 10-27=-290/2077, 8-10=-291/2062 WEBS 4-13=-43/338, 4-11=-311/1707, 5-11=-505/161, 6-11=-340/1804, 6-10=-19/290 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=209, 8=195. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 173 lb down and 48 lb up at 3-10-12, 115 lb down and 34 lb up at 5-2-4, 115 lb down and 34 lb up at 6-4-4, 115 lb down and 34 lb up at 8-4-4, 115 lb down and 34 lb up at 10-4-4, 115 lb down and 34 lb up at 12-4-4, 115 lb down and 34 lb up at 14-4-4, and 115 lb down and 34 lb up at 16-4-4, and 173 lb down and 48 lb up at 18-4-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG01 Truss Type Hip Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216442 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:29 2019 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-y9xpDZAC1Dw2jtciNbQOKe3zg2wiYP?x9WcXZVzC0l0 LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 6-9=-60, 14-18=-20 Concentrated Loads (lb) Vert: 12=-115(F) 13=-173(F) 10=-173(F) 22=-115(F) 23=-115(F) 24=-115(F) 25=-115(F) 26=-115(F) 27=-115(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG02 Truss Type Half Hip Girder Qty 2 Ply 1 659 West Clay Northlake Job Reference (optional) I37216443 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:31 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-uX2ZeFBSZrAmyBl4V?SsP39Tasky0YREcq5eeOzC0l_ Scale: 1"=1' 1 2 3 4 5 7 6 4x8 2x4 3x6 3x4 2x4 4x6 1-10-0 1-10-0 3-10-0 2-0-0 -1-0-0 1-0-0 1-10-0 1-10-0 3-10-0 2-0-0 0-11-01-10-06.00 12 Plate Offsets (X,Y)-- [4:0-5-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.08 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 7 7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=214/0-3-8, 6=138/Mechanical Max Horz 2=43(LC 4) Max Uplift 2=-39(LC 5), 6=-16(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 22 lb down and 17 lb up at 1-10-0 on top chord, and 4 lb up at 1-10-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 6-8=-20 Concentrated Loads (lb) Vert: 7=3(F) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG03 Truss Type Roof Special Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216444 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:33 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-qwAJ3xDi5SQUCVvTcQVKVUEeRgC6UHDX48akhHzC0ky Scale = 1:44.5 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 19 20 21 22 23 24 25 26 27 4x8 4x6 4x6 4x6 8x8 5x6 3x6 4x6 3x6 5x8 3x6 3x6 6x8 8x8 3-1-12 3-1-12 6-0-0 2-10-4 8-11-0 2-11-0 12-11-0 4-0-0 23-3-0 10-4-0 25-3-0 2-0-0 -0-11-0 0-11-0 3-1-12 3-1-12 6-0-0 2-10-4 8-11-0 2-11-0 12-11-0 4-0-0 18-1-0 5-2-0 23-3-0 5-2-0 25-3-0 2-0-0 26-2-0 0-11-0 0-11-01-11-03-11-00-11-03-11-06.00 12 Plate Offsets (X,Y)-- [4:0-5-4,0-2-0], [6:0-3-8,0-2-0], [11:0-2-8,0-2-12], [11:0-1-9,0-0-13], [12:0-4-0,0-3-4], [15:0-2-0,0-2-12], [18:0-1-12,0-0-0], [18:Edge,0-5-13] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.83 0.88 0.71 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.24 -0.63 0.07 (loc) 12-13 12-13 11 l/defl >999 >475 n/a L/d 240 180 n/a PLATES MT20 Weight: 114 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-1-0 oc purlins, except end verticals, and 2-0-0 oc purlins (2-4-9 max.): 4-5, 6-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15, 7-12 REACTIONS.(lb/size)18=1062/0-3-8, 11=1060/0-3-8 Max Horz 18=-42(LC 11) Max Uplift 18=-61(LC 5), 11=-117(LC 14) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1406/58, 3-4=-1453/91, 4-5=-1606/127, 5-6=-1809/119, 6-19=-3917/219, 19-20=-3917/219, 7-20=-3917/219, 7-21=-1443/77, 21-22=-1443/77, 8-22=-1443/77, 8-9=-1488/84, 2-18=-981/76, 9-11=-1092/93 BOT CHORD 16-17=-19/1213, 15-16=0/1265, 14-15=-164/3932, 13-14=-164/3932, 13-23=-261/3197, 23-24=-261/3197, 24-25=-261/3197, 25-26=-261/3197, 12-26=-261/3197 WEBS 4-15=-65/589, 5-15=0/566, 6-15=-2506/171, 7-13=0/787, 7-12=-1845/258, 8-12=0/513, 2-17=-8/1017, 9-12=-34/1219 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18 except (jt=lb) 11=117. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 27 lb down and 19 lb up at 15-2-4, 27 lb down and 19 lb up at 17-2-4, 27 lb down and 19 lb up at 19-2-4, and 27 lb down and 19 lb up at 21-2-4, and 64 lb down and 35 lb up at 23-3-0 on top chord, and 2 lb up at 15-2-4, 2 lb up at 17-2-4, 2 lb up at 19-2-4, and 2 lb up at 21-2-4, and 5 lb up at 23-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Continued on page 2 May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG03 Truss Type Roof Special Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216444 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:33 2019 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-qwAJ3xDi5SQUCVvTcQVKVUEeRgC6UHDX48akhHzC0ky LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-60, 2-4=-60, 4-5=-60, 5-6=-60, 6-8=-60, 8-9=-60, 9-10=-60, 11-18=-20 Concentrated Loads (lb) Vert: 23=0(F) 24=0(F) 25=0(F) 26=0(F) 27=1(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG04 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 3 659 West Clay Northlake Job Reference (optional) I37216445 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:35 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-nJI4TdEzd3gCRo3rkrXoavJxnTycy80qXS3rm9zC0kw Scale = 1:44.0 1 2 3 4 5 6 7 8 9 10 21 20 19 18 17 16 15 14 13 12 11 22 23 24 25 26 27 28 10x10 8x8 6x10 5x10 MT18HS 10x10 5x10 MT18HS 3x6 5x6 3x6 3x6 8x8 2x4 2x4 3x12 3x6 4x8 6x8 3x6 5x6 2-8-3 2-8-3 5-0-13 2-4-11 7-5-8 2-4-11 9-3-8 1-10-0 12-9-7 3-5-15 16-1-9 3-4-3 19-7-8 3-5-15 22-3-8 2-8-0 25-3-0 2-11-8 2-8-3 2-8-3 5-0-13 2-4-11 7-5-8 2-4-11 9-3-8 1-10-0 12-9-7 3-5-15 16-1-9 3-4-3 19-7-8 3-5-15 22-3-8 2-8-0 25-3-0 2-11-8 0-11-03-8-124-7-120-11-03-8-126.00 12 Plate Offsets (X,Y)-- [1:0-3-12,Edge], [5:0-5-4,0-2-12], [7:0-2-0,0-2-0], [8:0-6-4,0-2-0], [10:0-3-12,Edge], [11:0-3-4,0-1-10], [12:0-2-0,0-1-12], [18:0-4-0,0-3-4], [20:0-2-8,0-1-8], [21:0-3-4,0-1-10] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.97 0.62 0.95 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.25 -0.56 0.10 (loc) 15-17 15-17 11 l/defl >999 >526 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 439 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 4-18: 2x4 SPF 2100F 1.8E 5-17,6-15,7-14,8-13,1-20,10-12: 2x4 SPF No.2 1-21,10-11: 2x8 SP 2400F 2.0E BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins, except end verticals, and 2-0-0 oc purlins (3-0-3 max.): 5-8. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)21=11068/0-3-8, 11=10404/0-3-8 Max Horz 21=54(LC 4) Max Uplift 21=-573(LC 6), 11=-583(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-13832/739, 2-3=-15182/842, 3-4=-14611/847, 4-5=-14530/841, 5-6=-19576/1172, 6-7=-19576/1172, 7-8=-14023/836, 8-9=-15384/903, 9-10=-14166/810, 1-21=-9156/489, 10-11=-9114/529 BOT CHORD 21-22=-159/2438, 20-22=-159/2438, 20-23=-639/12286, 19-23=-639/12286, 18-19=-680/13557, 17-18=-962/18247, 16-17=-965/18328, 15-16=-965/18328, 15-24=-992/18148, 24-25=-992/18148, 14-25=-992/18148, 14-26=-992/18148, 13-26=-992/18148, 13-27=-685/12573, 12-27=-685/12573, 12-28=-131/2411, 11-28=-131/2411 WEBS 2-20=-1625/118, 2-19=-88/1630, 3-19=-32/879, 3-18=-811/80, 4-18=-703/12517, 5-18=-10737/658, 5-17=-67/1872, 5-15=-158/1787, 7-15=-136/2021, 7-14=-97/2527, 7-13=-5839/359, 8-13=-346/6642, 9-13=-106/1426, 9-12=-1387/121, 1-20=-528/10237, 10-12=-572/10485 NOTES-(11-12) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 18-4 2x4 - 1 row at 0-7-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 21=573, 11=583. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.Continued on page 2 May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG04 Truss Type ROOF SPECIAL GIRDER Qty 1 Ply 3 659 West Clay Northlake Job Reference (optional) I37216445 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:35 2019 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-nJI4TdEzd3gCRo3rkrXoavJxnTycy80qXS3rm9zC0kw NOTES-(11-12) 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1701 lb down and 86 lb up at 1-2-4, 1701 lb down and 86 lb up at 3-2-4, 1701 lb down and 86 lb up at 5-2-4, 1700 lb down and 86 lb up at 7-2-4, 1700 lb down and 86 lb up at 9-2-4, 1700 lb down and 86 lb up at 11-2-4, 795 lb down and 102 lb up at 13-2-4, 1700 lb down and 86 lb up at 15-2-4, 1700 lb down and 86 lb up at 17-2-4, 1700 lb down and 86 lb up at 19-2-4, and 1700 lb down and 86 lb up at 21-2-4, and 1700 lb down and 86 lb up at 23-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 5-8=-60, 8-10=-60, 11-21=-20 Concentrated Loads (lb) Vert: 16=-1700(B) 19=-1701(B) 18=-1700(B) 17=-1700(B) 13=-1700(B) 22=-1701(B) 23=-1701(B) 24=-795(B) 25=-1700(B) 26=-1700(B) 27=-1700(B) 28=-1700(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG05 Truss Type Jack-Closed Girder Qty 2 Ply 1 659 West Clay Northlake Job Reference (optional) I37216446 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:35 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-nJI4TdEzd3gCRo3rkrXoavJ7bT0hyMdqXS3rm9zC0kw Scale = 1:17.0 1 2 3 5 46 2x4 2x4 3x4 3x4 3-10-0 3-10-0 -1-0-0 1-0-0 3-10-0 3-10-0 0-11-02-10-06.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.21 0.36 0.02 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.02 -0.05 -0.00 (loc) 4-5 4-5 4 l/defl >999 >902 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)5=281/0-3-8, 4=193/Mechanical Max Horz 5=84(LC 4) Max Uplift 5=-53(LC 5), 4=-36(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 118 lb down and 30 lb up at 1-10-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-5=-20 Concentrated Loads (lb) Vert: 6=-118(F) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG06 Truss Type Hip Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216447 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:37 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-jhPquIGD9hxwg6DErGZGfKPOkHauQ5u7_mYyq2zC0ku Scale = 1:35.4 1 2 3 4 5 6 7 8 9 10 15 14 13 12 11 24 25 26 27 28 29 4x8 4x6 6x10 3x4 4x6 2x4 4x8 2x4 2x4 3x6 3x8 6x10 3x4 4-0-0 4-0-0 8-0-4 4-0-4 11-10-12 3-10-8 15-11-0 4-0-4 19-11-0 4-0-0 -1-0-0 1-0-0 4-0-0 4-0-0 8-0-4 4-0-4 11-10-12 3-10-8 15-11-0 4-0-4 19-11-0 4-0-0 20-11-0 1-0-0 0-11-02-11-00-11-02-11-06.00 12 Plate Offsets (X,Y)-- [2:0-6-13,0-0-4], [4:0-6-4,0-2-0], [9:0-6-9,0-0-4], [13:0-2-12,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.55 0.89 0.67 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.10 -0.24 0.05 (loc) 12-13 12-13 9 l/defl >999 >979 n/a L/d 240 180 n/a PLATES MT20 Weight: 86 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0, Right 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-13 oc purlins, except 2-0-0 oc purlins (3-2-2 max.): 4-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1360/0-3-8, 9=1318/0-3-8 Max Horz 2=32(LC 13) Max Uplift 2=-183(LC 5), 9=-169(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-906/121, 3-4=-1915/254, 4-24=-2659/371, 5-24=-2659/371, 5-6=-2659/371, 6-25=-1652/222, 7-25=-1652/222, 7-8=-1871/241, 8-9=-875/110 BOT CHORD 2-26=-204/1656, 15-26=-204/1656, 14-15=-200/1656, 13-14=-200/1656, 13-27=-338/2671, 12-27=-338/2671, 12-28=-338/2671, 11-28=-338/2671, 11-29=-176/1617, 9-29=-176/1617 WEBS 4-13=-191/1220, 5-13=-278/97, 6-12=-12/401, 6-11=-1251/203, 7-11=-15/607 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=183, 9=169. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 61 lb down and 46 lb up at 4-0-0, 49 lb down and 49 lb up at 6-0-12, 29 lb down and 15 lb up at 8-0-12, 28 lb down and 17 lb up at 12-0-12, and 49 lb down and 49 lb up at 14-0-12, and 61 lb down and 46 lb up at 15-11-0 on top chord, and 126 lb down and 33 lb up at 2-0-12, 33 lb down at 4-0-12, 34 lb down at 6-0-12, 160 lb down and 35 lb up at 8-0-12, 183 lb down and 34 lb up at 10-0-12, 152 lb down and 33 lb up at 12-0-12, 34 lb down at 14-0-12, and 33 lb down at 15-10-4, and 70 lb down and 15 lb up at 17-10-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG06 Truss Type Hip Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216447 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:37 2019 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-jhPquIGD9hxwg6DErGZGfKPOkHauQ5u7_mYyq2zC0ku LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-7=-60, 7-10=-60, 16-20=-20 Concentrated Loads (lb) Vert: 4=-42(F) 7=-42(F) 14=-25(F) 15=-22(F) 13=-160(F) 12=-152(F) 11=-22(F) 24=-49(F) 25=-49(F) 26=-126(F) 27=-183(F) 28=-25(F) 29=-70(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG07 Truss Type Half Hip Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216448 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:37 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-jhPquIGD9hxwg6DErGZGfKPV3HnMQFt7_mYyq2zC0ku Scale = 1:12.3 1 2 3 4 5 7 6 4x8 2x4 3x6 3x4 2x4 4x6 2-0-0 2-0-0 4-0-0 2-0-0 -1-0-0 1-0-0 2-0-0 2-0-0 4-0-0 2-0-0 0-11-01-11-06.00 12 Plate Offsets (X,Y)-- [4:0-5-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.08 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 10 10 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=221/0-3-8, 6=146/Mechanical Max Horz 2=46(LC 4) Max Uplift 2=-42(LC 5), 6=-20(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 15 lb down and 30 lb up at 2-0-0 on top chord, and 4 lb up at 2-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 6-8=-20 Concentrated Loads (lb) Vert: 7=2(B) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG08 Truss Type Roof Special Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216449 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:38 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-BuzC6eHrw_3nIGoQP_4VCXxgzh5u9ijGDQHVMUzC0kt Scale = 1:17.7 1 2 3 4 5 6 9 8 714 4x8 4x6 3x4 4x6 3x6 3x4 2x4 3x4 2-4-0 2-4-0 3-10-0 1-6-0 5-6-0 1-8-0 -0-11-4 0-11-4 2-4-0 2-4-0 3-10-0 1-6-0 5-6-0 1-8-0 0-11-02-1-02-11-02-6-52-11-02-1-06.00 12 Plate Offsets (X,Y)-- [4:0-5-0,0-2-0], [6:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.07 0.07 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 12 9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=46/Mechanical, 7=180/Mechanical, 2=320/0-3-8 Max Horz 2=74(LC 10) Max Uplift 6=-16(LC 4), 7=-23(LC 5), 2=-66(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7, 2. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 61 lb down and 34 lb up at 1-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 5-6=-60, 7-10=-20 Concentrated Loads (lb) Vert: 14=-61(B) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG09 Truss Type Roof Special Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216450 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:39 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-f4XbJ_HThIBewQNdzhbkklUri4RFu9vPS313vwzC0ks Scale = 1:17.7 1 2 3 4 5 6 9 8 714 4x8 4x6 3x4 4x6 3x6 3x4 2x4 3x4 2-1-8 2-1-8 3-7-8 1-6-0 5-6-0 1-10-8 -0-11-4 0-11-4 2-1-8 2-1-8 3-7-8 1-6-0 5-6-0 1-10-8 0-11-01-11-122-11-02-6-52-11-01-11-126.00 12 Plate Offsets (X,Y)-- [4:0-5-0,0-2-0], [6:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.07 0.07 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 9 9 7 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=52/Mechanical, 7=172/Mechanical, 2=315/0-3-8 Max Horz 2=74(LC 4) Max Uplift 6=-17(LC 4), 7=-21(LC 5), 2=-67(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 7, 2. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 54 lb down and 35 lb up at 1-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 5-6=-60, 7-10=-20 Concentrated Loads (lb) Vert: 14=-54(F) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG10 Truss Type Half Hip Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216451 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:40 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-7G5zXKI5ScJUXaypXO7zHy00IUo3dccZhjmcRNzC0kr Scale = 1:12.3 1 2 3 4 5 7 6 4x8 3x6 3x4 2x4 4x6 3x6 2-0-0 2-0-0 4-0-0 2-0-0 -1-0-0 1-0-0 2-0-0 2-0-0 4-0-0 2-0-0 0-11-01-11-01-7-81-11-06.00 12 Plate Offsets (X,Y)-- [4:0-5-0,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MP 0.08 0.03 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 10 10 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud SLIDER Left 2x4 SPF-S Stud 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=221/0-3-8, 6=90/Mechanical, 5=56/Mechanical Max Horz 2=46(LC 4) Max Uplift 2=-42(LC 13), 6=-2(LC 12), 5=-17(LC 3) Max Grav 2=221(LC 1), 6=96(LC 2), 5=56(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6, 5. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 12 lb down and 26 lb up at 2-0-0 on top chord, and 4 lb up at 2-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 6-8=-20 Concentrated Loads (lb) Vert: 7=2(F) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG11 Truss Type Half Hip Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216452 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:40 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-7G5zXKI5ScJUXaypXO7zHy017UoDdcxZhjmcRNzC0kr Scale = 1:11.2 1 2 3 6 5 4 4x6 2x4 3x8 2x4 4x6 1-2-0 1-2-0 2-4-0 1-2-0 1-6-0 1-6-0 2-4-0 0-10-0 0-11-01-8-06.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.03 0.02 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-4-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 2-3. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=222/0-3-8, 4=81/Mechanical Max Horz 6=39(LC 4) Max Uplift 4=-22(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 13 lb down and 14 lb up at 2-2-4 on top chord, and 141 lb down at 0-1-12, and 3 lb up at 1-4-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-6=-20 Concentrated Loads (lb) Vert: 3=-0(F) 6=-141(B) 5=1(F) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG12 Truss Type Half Hip Girder Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216453 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:42 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-3fDjx0KM_DZCnt5Bep9RMN6NjIUk5WRs81FjVFzC0kp Scale = 1:11.2 1 2 3 6 5 47 4x6 2x4 3x8 2x4 4x6 1-0-12 1-0-12 2-1-8 1-0-12 1-6-0 1-6-0 2-1-8 0-7-8 0-11-01-8-06.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.03 0.02 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 -0.00 (loc) 5 5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-8 oc purlins, except end verticals, and 2-0-0 oc purlins: 2-3. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)6=195/0-3-8, 4=73/Mechanical Max Horz 6=39(LC 4) Max Uplift 4=-23(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 122 lb down at 0-1-12, and 2 lb down and 16 lb up at 1-11-12 on top chord, and 2 lb down and 2 lb up at 1-4-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 4-6=-20 Concentrated Loads (lb) Vert: 3=-0(B) 1=-122(F) 7=1(B) May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG13 Truss Type Common Girder Qty 1 Ply 2 659 West Clay Northlake Job Reference (optional) I37216454 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:43 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-Yrn59MK_kXh3O1gOCXggubePFimnql9?Nh?G2izC0ko Scale = 1:39.6 1 2 3 4 5 10 9 8 7 6 11 12 13 14 15 16 4x6 4x6 4x6 3x6 3x6 8x8 3x6 6x10 3x6 6x10 3-3-0 3-3-0 6-2-8 2-11-8 9-2-0 2-11-8 12-5-0 3-3-0 3-3-0 3-3-0 6-2-8 2-11-8 9-2-0 2-11-8 12-5-0 3-3-0 1-3-06-5-11-3-010.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-12], [2:0-2-12,0-1-8], [4:0-2-12,0-1-8], [5:0-3-0,0-1-12], [6:0-2-12,0-1-8], [7:0-3-0,0-3-8], [9:0-3-0,0-3-8], [10:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2006/TPI2002 CSI. TC BC WB Matrix-MSH 0.55 0.28 0.94 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.04 -0.09 0.01 (loc) 8-9 8-9 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 152 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP 2400F 2.0E WEBS 2x4 SPF-S Stud *Except* 3-8,1-10,5-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-6-11 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)10=5907/0-3-8, 6=5175/0-3-8 Max Horz 10=-150(LC 3) Max Uplift 10=-289(LC 5), 6=-254(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-4965/274, 2-3=-3872/269, 3-4=-3872/269, 4-5=-4955/273, 1-10=-4260/224, 5-6=-4261/224 BOT CHORD 10-11=-160/479, 11-12=-160/479, 9-12=-160/479, 9-13=-220/3749, 8-13=-220/3749, 8-14=-159/3741, 14-15=-159/3741, 7-15=-159/3741, 7-16=-25/448, 6-16=-25/448 WEBS 3-8=-285/4679, 4-8=-1238/140, 4-7=-72/1521, 2-8=-1249/140, 2-9=-72/1537, 1-9=-143/3420, 5-7=-145/3445 NOTES-(9-10) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 10=289, 6=254. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1688 lb down and 84 lb up at 0-9-4, 1685 lb down and 86 lb up at 2-9-4, 1685 lb down and 86 lb up at 4-9-4, 1685 lb down and 86 lb up at 6-9-4, and 1685 lb down and 86 lb up at 8-9-4, and 1685 lb down and 86 lb up at 10-9-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss TG13 Truss Type Common Girder Qty 1 Ply 2 659 West Clay Northlake Job Reference (optional) I37216454 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:43 2019 Page 2 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-Yrn59MK_kXh3O1gOCXggubePFimnql9?Nh?G2izC0ko LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-5=-60, 6-10=-20 Concentrated Loads (lb) Vert: 11=-1688(B) 12=-1685(B) 13=-1685(B) 14=-1685(B) 15=-1685(B) 16=-1685(B) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V01 Truss Type GABLE Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216455 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:43 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-Yrn59MK_kXh3O1gOCXggubeSuimXqzv?Nh?G2izC0ko Scale = 1:33.7 1 2 3 4 5 6 7 12 11 10 9 83x4 2x4 3x12 3x6 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 20-10-1 20-10-1 5-9-8 5-9-8 15-0-8 9-3-0 20-10-1 5-9-8 0-0-42-10-120-0-42-10-126.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-1-8], [6:0-3-11,0-1-10], [7:0-5-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.38 0.30 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 47 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-10-1. (lb) - Max Horz 1=-26(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 8, 9, 10, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 8=399(LC 11), 9=328(LC 10), 10=298(LC 1), 12=267(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-9=-261/86 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 8, 9, 10, 12. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V02 Truss Type GABLE Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216456 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:44 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-02LUMiLcVqpw0BFamEBvRoBct54iZP48bLkqa8zC0kn Scale = 1:27.2 1 2 3 4 5 6 10 9 8 72x4 2x4 3x8 2x4 2x4 4x6 2x4 2x4 2x4 2x4 16-10-1 16-10-1 5-9-8 5-9-8 11-0-8 5-3-0 16-10-1 5-9-8 0-0-42-10-120-0-42-10-126.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-1-8], [5:0-3-11,0-1-10], [6:0-3-7,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.43 0.43 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-10-1. (lb) - Max Horz 1=-26(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 6, 7, 9, 10 Max Grav All reactions 250 lb or less at joint(s) 1, 6 except 7=414(LC 11), 9=304(LC 10), 10=281(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-7=-276/84 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6, 7, 9, 10. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V03 Truss Type GABLE Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216457 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:44 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-02LUMiLcVqpw0BFamEBvRoBcZ56_ZQM8bLkqa8zC0kn Scale = 1:20.8 1 2 3 4 6 53x12 3x12 2x4 4x6 2x4 4x6 12-10-1 12-10-1 5-9-8 5-9-8 7-0-8 1-3-0 12-10-1 5-9-8 0-0-42-10-120-0-42-10-126.00 12 Plate Offsets (X,Y)-- [1:0-9-11,Edge], [2:0-3-11,0-1-10], [3:0-3-11,0-1-10], [4:0-5-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.39 0.29 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 29 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 2-3. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 12-10-1. (lb) - Max Horz 1=26(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 4, 5, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 4 except 5=348(LC 11), 6=348(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5, 6. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V04 Truss Type Valley Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216458 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:45 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-UEusa1MEG8xneLqmJyi8_0klDVQgItiIq?UN6azC0km Scale: 3/4"=1' 1 2 3 4 2x4 3x4 2x4 2x4 0-0-8 0-0-8 8-10-1 8-9-9 4-5-0 4-5-0 8-10-1 4-5-0 0-0-42-2-80-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.52 0.32 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=160/8-9-1, 3=160/8-9-1, 4=313/8-9-1 Max Horz 1=-19(LC 4) Max Uplift 1=-23(LC 6), 3=-27(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V05 Truss Type Valley Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216459 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:45 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-UEusa1MEG8xneLqmJyi8_0ksMVQeItMIq?UN6azC0km Scale = 1:8.9 1 2 3 2x4 2x4 2x4 0-0-8 0-0-8 4-10-1 4-9-9 2-5-0 2-5-0 4-10-1 2-5-0 0-0-41-2-80-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.13 0.32 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=156/4-9-1, 3=156/4-9-1 Max Horz 1=-10(LC 4) Max Uplift 1=-8(LC 6), 3=-8(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V06 Truss Type Valley Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216460 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:45 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-UEusa1MEG8xneLqmJyi8_0kn3VR3IstIq?UN6azC0km Scale = 1:28.4 1 2 3 44x8 5x6 4x8 2x4 0-0-5 0-0-5 10-10-7 10-10-2 5-5-3 5-5-3 10-10-7 5-5-3 0-0-44-6-60-0-410.00 12 Plate Offsets (X,Y)-- [1:0-7-1,Edge], [3:0-4-5,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-SH 0.40 0.30 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=202/10-9-13, 3=202/10-9-13, 4=405/10-9-13 Max Horz 1=-99(LC 4) Max Uplift 1=-13(LC 6), 3=-19(LC 7), 4=-2(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V07 Truss Type Valley Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216461 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:46 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-yQSEnNNs1S3eFVPztfDNWDGw_vmv1KmR3fDwf0zC0kl Scale = 1:23.4 1 2 3 42x4 3x4 2x4 2x4 0-0-5 0-0-5 8-5-10 8-5-5 4-2-13 4-2-13 8-5-10 4-2-13 0-0-43-6-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.52 0.32 0.05 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=179/8-5-0, 3=179/8-5-0, 4=273/8-5-0 Max Horz 1=-76(LC 4) Max Uplift 1=-26(LC 7), 3=-32(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V08 Truss Type Valley Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216462 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:46 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-yQSEnNNs1S3eFVPztfDNWDG?BvpT1KCR3fDwf0zC0kl Scale = 1:17.6 1 2 3 4 2x4 3x4 2x4 2x4 0-0-5 0-0-5 6-0-13 6-0-8 3-0-7 3-0-7 6-0-13 3-0-7 0-0-42-6-60-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.25 0.16 0.03 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=125/6-0-4, 3=125/6-0-4, 4=190/6-0-4 Max Horz 1=-53(LC 4) Max Uplift 1=-18(LC 7), 3=-22(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job 659_West_Clay_Northlake Truss V09 Truss Type Valley Qty 1 Ply 1 659 West Clay Northlake Job Reference (optional) I37216463 8.220 s Mar 22 2019 MiTek Industries, Inc. Tue May 28 08:44:46 2019 Page 1 PROBUILD, MOORESVILLE, IN 46158 ID:r0G7gzmN1maxDG0IXKUAUPz4Niz-yQSEnNNs1S3eFVPztfDNWDG1svon1KbR3fDwf0zC0kl Scale = 1:10.4 1 2 3 2x4 2x4 2x4 0-0-5 0-0-5 3-8-0 3-7-12 1-10-0 1-10-0 3-8-0 1-10-0 0-0-41-6-60-0-410.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2006/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.20 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-8-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=124/3-7-7, 3=124/3-7-7 Max Horz 1=-30(LC 4) Max Uplift 1=-4(LC 6), 3=-4(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 28,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths