Loading...
HomeMy WebLinkAboutEnergy compliance BRG 234 - (AS DESIGNED)IECC 2009 Performance Compliance Property 541 ELLIOT CREEK DR CARMEL, IN 46032 Model: ZION Community: BRIDGEMONT AT JACI (AS DESIGNED) BRIDGEMONT AT JACKSONS GRP Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,785 $282 $342 $2,409 $969 $0 $3,377 Requirements C-M, Energy Solutions As Designed $1,567 $206 $342 $2,114 $969 $0 $3,083 C4405.3 Performance-based compliance passes by 122% R402.4.12 Air Leakage Testing Air sealing is 5.0[) ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U -Factor 403.2.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R405.2 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 12.2%. Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name Organization Devin Sielschott TSI Energy Solutions Signature: Date: 5/13119 at 12:08 PM Ekotrope RATER - Version 3.1.0.2170 IECC 2009 Performance compliance results calculated using Eketrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all1iabitityfor the information shown on this report. 541 ELLIOT CREEK DR CARMEL, IN 46032 Builder: HOMES BY McKENZIE, INC. Ceiling Attic, R-50 Above Grade Walls R-15 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U -Value: 0.29, SHGC: 0.27 Building Features Duct Supply R-20.0, Return R-20.0 Duct Leakage to Outside 175.0 CFM @ 25Pa Total Duct Leakage 280.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric - 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 5/13119 at 12:08 PM Ekotrope RATER - Version 3.1.0.2170 2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 541 ELLIOT CREEK DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: ZION Community: BRIDGEMONT AT JACI Builder HOMES BY McKENZIE, (AS DESIGNED) INC. BRIDGEMONT AT JACKSONS GRP General Building Information Conditioned Area (sq ft) 3,519 Conditioned Volume (cubic ft) 34,268 Insulated Shell Area (sq ft) 8,740 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (2,542 s.f.) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall Name: CONDIAMB (2,942 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CON DIGAR (240 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIATTIC (322 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Energy Cade Inspection Checklist Property 541 ELLIOT CREEK DR CARMEL, IN 46032 Model: ZION Community: BRIDGEMONT AT JACI (AS DESIGNED) BRIDGEMONT AT JACKSONS GRP Name: CONDIAMB (70 s.f.) R: 11.691 Name: CON DIATTIC (82 s.f.) R: 11.691 Roof Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY McKENZIE, INC. El Name: MAIN (2,542 s.f.) R-39.73 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door 1� Name: FRONT (48 s.f.) J--� U: 0.476 Name: GARAGE (20 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (114 s.f.), U:0.290, SHGC: 0.27, Orientation: EAST El Name: BACK (168 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST [] Name: slider (48 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST El Name: LEFT SIDE (24 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH 11 Name: RIGHT SIDE (51 s.f.), U:0.290, SHGC: 0.27, Orientation: NORTH Skylight None Present Mechanical Ventilation None Present C-M, Energy Solutions 2 Energy Code Inspection Checklist Property Organization 541 ELLIOT CREEK DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: ZION Community: BRIDGEMONT AT JACI Builder HOMES BY McKENZIE, (AS DESIGNED) INC. BRIDGEMONT AT JACKSONS GRP Mechanical Equipment Inspection Status Results are projected GAS FURNACE 1 • Natural Gas • 100% Heating Load @ 92.1 AFUE U Air conditioner 1 • Electric • 100% Cooling Load @ 13 SEER Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 2,856 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 175.0 CFM @ 25pa Total Duct Leakage is specified in Ekotrope at 280.0 CFM @ 25Pa C", Energy Solutions 3 Energy Code Inspection Checklist Property Organization 541 ELLIOT CREEK DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: ZION Community: BRIDGEMONT AT JACI Builder HOMES BY McKENZIE, (AS DESIGNED) INC. BRIDGEMONT AT JACKSONS GRP Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 3 CFM251 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 541 ELLIOT CREEK DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: ZION Yes Community: BRI DGEMONT AT JACKSONS GRANT Builder Total Units in Building HOMES BY McKENZIE, INC. [AS DESIGNED] Single family detached BRIDGEMONTAT JACKSONS GRANT 234 General Building Information Number Of Bedrooms 3 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 3,519 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 34,268 Total Units in Building 1 Residence Type Single family detached Floor Number Model ZION Community BRIDGEMONT AT JACKSONS GRANT 234 Climate Zone 5A Basement Wall Basement Wall Library List Slab AL Name Library Type None Present C-M, Energy Solutions SLAB R-101'down, 2' in 247 On Grade ❑ ❑ 2,542.0 sq. ft. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Camplet Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10 1'down. 2' in Wood Frame 1 Other No 2 1 10 No 10.00 Framed Floor None Present 1 Building Summary Property Organization 541 ELLIOT CREEK DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: ZION Community: BRI DGEMONT ATJACKSONS GRANT Builder Name HOMES BY McKENZIE, INC. [AS DESIGNED] Surface Area BRIDGEMONTAT JACKSONS GRANT 234 CONDIAMB Framed Floor Library List mmdm None Present Rim Jois Name CONDIAMB CONDIATTIC Rim Joist Library List uorary TYPE G1 R-15, OSB Inspection Status Results are projected 70.0 sq. R. C-M, Energy Solutions Exposed Exterior G1 R-15, OSB 82.0 sq. R. Unconditioned, attached garage Name Effective Insulation R•value Name Effective R -value G1 R-15 BATT. OSB G1 R-15. OSB 11.691 11.972 Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-15 BATT, OSB Medium 2,942.0 sq. R. Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 322.0 sq. ft. Attic CONDIGAR G1 R-15 Gar Walls Medium 240.0 sq. tt. Unconditioned. attached garage Wall Library List Name Effective R -value G1 R-15 BATT. OSB 13.423 G1 R-15 Gar Walls 11.972 Building Summary Emittance Solar Surface Color Surface Area Location Assignment Property Organization Inspection Status FRONT Wood Door CONDIAMB C-MEnergy Solutions 541 ELLIOT CREEK DR TSI Energy Solutions Results are projected Exposed Exterior 0.9 0.75 Medium CARMEL, IN 46032 Devin Sielschott Model: ZION Community: BRI DGEMONT ATJACKSONS GRANT Builder HOMES BY MCKENZIE, INC. [AS DESIGNED] BRIDGEMONTAT JACKSONS GRANT 234 Glazing Name Library type Wall Assignment Basement Wall Overhang Assignment Depth Overhang Ft To Overhang Top Ft To Bottom Orientation Surface Area BACK U-29, SHGC-27 CONDIAMB 0 0 0 West 168.0 sq. ft. FRONT U-29, SHGC-27 CONDIAMB 0 0 0 East 114.0 sq. ft. LEFT SIDE U-29, SHGC-27 CONDIAMB 0 0 0 South 24.0 sq. ft. RIGHT SIDE U-29, SHGC-27 CONDIAMB 0 0 0 North 51.0 sq. ft. slider U-29, SHGC-27 CONDIAMB 0 0 0 West 48.0 sq. ft. Glazing Library List Name U-.29, SHGC-.27 Skylight anyc LO-idcwi 027 0290 Skylight Library List None Present Opaque Door Name Library Type WallAssignment Basement Wall Emittance Solar Surface Color Surface Area Location Assignment Ab so rp to n ce FRONT Wood Door CONDIAMB 0.9 0.75 Medium 48.0 sq. ft. Exposed Exterior GARAGE Steel Door CONDIGAR Exposed Exterior 0.9 0.75 Medium 20.0 sa_ ft. 3 Building Summary Property Organization 541 ELLIOT CREEK DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: ZION Community: BRIOGEMONT AT JACKSONS GRANT Builder HOMES BY MCKENZIE, INC. [AS DESIGNED] BRIDG EIJONT AT JACKSONS GRANT 234 Opaque Door Library List Name Effective U -factor Steel Door 0.182 Wood Door 0.476 Inspection Status Results are projected C-M, Energy Solutions Roof Insulation Name Library type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location j•..f.] Tiles klAIN R-50 Blown, GR1 2,542 No Medium 2.542.0 sq. 1t. Attic Roof Insulation Library List Name Has Radiant Barrier R-50 Blown, GR1 No Whole House Infiltration Infiltration Measurement type 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation None Present Lighting Interior Fluores Ligh 10 ■ Effective R -value 50.474 Shelter Class 4 0 0 ge Fluorescent 1 Garage LED Lighting Lighting C 4 Building Summary Property Organization 541 ELLIOT CREEK DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: ZION 100% Community: BRI DGEMONT ATJACKSONS GRANT Builder Water Heating HOMES BY McKENZIE, INC. [AS DESIGNED] 0% BRIDGEMONTAT JACKSONS GRANT 234 Onsite Generation None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment A Name Inspection Status Results are projected C-M, Energy Solutions Hot Water Percent Load Air conditioner 1 CA13NA048 0% 100% 0% GAS FURNACE 1 912SA48080917 100% 0% 0% Water Heating ENT 50 100 0% 0% 100% Equipment Type: 912SA4808OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 977 Building Summary Property 541 ELLIOT CREEK DR CARMEL, IN 46032 Model: ZION Community: BRI DGEMONT AT JACKSONS GRANT [AS DESIGNED] BRIDG EIJONT AT JACKSONS GRANT 234 Equipment Type: Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. CA13NA048 ilp� Equipment Type: ENT 50 100 Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Electric Forced Air PSG (Single Speed) 13 SEER 45.5 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property Organization 541 ELLIOT CREEK DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: ZION 3519 Community: BRI DGEMONT ATJACKSONS GRANT Builder Supply Duct R Value HOMES BY MCKENZIE, INC. [AS DESIGNED] 20 BRIDGEMONTAT JACKSONS GRANT 234 956.13 Distribution System Distribution Type Forced Air Heating Equipment GAS FURNACE 1 Cooling Equipment Air conditioner t Sq. Feet Served 3519 # Return Grilles 3 Supply Duct R Value 20 Return Duct R Value 20 Supply Duct Area [sq. ft.] 956.13 Return Duct Area [sq. ft] 527.85 Duct Leakage to Outdoors (CFM25) 175 Total Leakage 280 Total Leakage Dud Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Attic (well vented, under insulation) Percent Supply Area 90 Percent Return Area 90 Duct 2 Duct Location Conditioned Space Percent Supply Area 10 Percent Return Area 10 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 541 ELLIOT CREEK DR CARMEL, IN 46032 Model: ZION Community: BRI DGEMONT AT JACKSONS GRANT [AS DESIGNED] BRIDGEMONTAT JACKSONS GRANT 234 Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 86 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 30 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.62 Field Utilization Timer Controls asher VWV Label Energy Rating 704 kWh/Year Electric Rate $0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 Imet ❑.331 Appliances and Controls M Programmable thermostat? Yes Dishwasher Size Standard Dishwasher Efficiency 270 kWh Range/Oven Fuel Electric Convection Oven? No Induction Range? No Refrigerator Consumption 709 kVVh/Year Inspection Status Results are projected C-M, Energy Solutions