HomeMy WebLinkAboutEnergy compliance BRG 234 - (AS DESIGNED)IECC 2009 Performance Compliance
Property
541 ELLIOT CREEK DR
CARMEL, IN 46032
Model: ZION
Community: BRIDGEMONT AT JACI
(AS DESIGNED)
BRIDGEMONT AT JACKSONS GRP
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE,
INC.
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,785
$282
$342
$2,409
$969
$0
$3,377
Requirements
C-M,
Energy Solutions
As Designed
$1,567
$206
$342
$2,114
$969
$0
$3,083
C4405.3
Performance-based compliance passes by 122%
R402.4.12
Air Leakage Testing Air sealing is 5.0[) ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa.
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U -Factor
403.2.2
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R405.2
Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 12.2%.
Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and thatthe mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name
Organization
Devin Sielschott
TSI Energy Solutions
Signature:
Date:
5/13119 at 12:08 PM
Ekotrope RATER - Version 3.1.0.2170
IECC 2009 Performance compliance results calculated using Eketrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all1iabitityfor the information shown on this report.
541 ELLIOT CREEK DR
CARMEL, IN 46032
Builder: HOMES BY McKENZIE, INC.
Ceiling Attic, R-50
Above Grade Walls R-15
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 5 ACH50
Window U -Value: 0.29, SHGC: 0.27
Building Features
Duct Supply R-20.0, Return R-20.0
Duct Leakage to Outside 175.0 CFM @ 25Pa
Total Duct Leakage 280.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric - 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedAested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 5/13119 at 12:08 PM
Ekotrope RATER - Version 3.1.0.2170
2009 IECC compliance resuIts calculated using Ekotrope RATERS energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property Organization
541 ELLIOT CREEK DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: ZION
Community: BRIDGEMONT AT JACI Builder
HOMES BY McKENZIE,
(AS DESIGNED) INC.
BRIDGEMONT AT JACKSONS GRP
General Building Information
Conditioned Area (sq ft) 3,519
Conditioned Volume (cubic ft) 34,268
Insulated Shell Area (sq ft) 8,740
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (2,542 s.f.)
R-10 perimeter insulation, R-10 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
Name: CONDIAMB (2,942 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CON DIGAR (240 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (322 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
Energy Cade Inspection Checklist
Property
541 ELLIOT CREEK DR
CARMEL, IN 46032
Model: ZION
Community: BRIDGEMONT AT JACI
(AS DESIGNED)
BRIDGEMONT AT JACKSONS GRP
Name: CONDIAMB (70 s.f.)
R: 11.691
Name: CON DIATTIC (82 s.f.)
R: 11.691
Roof
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY McKENZIE,
INC.
El Name: MAIN (2,542 s.f.)
R-39.73 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
1� Name: FRONT (48 s.f.)
J--� U: 0.476
Name: GARAGE (20 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (114 s.f.), U:0.290, SHGC: 0.27, Orientation: EAST
El Name: BACK (168 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST
[] Name: slider (48 s.f.), U:0.290, SHGC: 0.27, Orientation: WEST
El Name: LEFT SIDE (24 s.f.), U:0.290, SHGC: 0.27, Orientation: SOUTH
11 Name: RIGHT SIDE (51 s.f.), U:0.290, SHGC: 0.27, Orientation: NORTH
Skylight
None Present
Mechanical Ventilation
None Present
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property Organization
541 ELLIOT CREEK DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: ZION
Community: BRIDGEMONT AT JACI Builder
HOMES BY McKENZIE,
(AS DESIGNED) INC.
BRIDGEMONT AT JACKSONS GRP
Mechanical Equipment
Inspection Status
Results are projected
GAS FURNACE 1 • Natural Gas • 100% Heating Load @ 92.1 AFUE
U Air conditioner 1 • Electric • 100% Cooling Load @ 13 SEER
Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 2,856 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 175.0 CFM @ 25pa
Total Duct Leakage is specified in Ekotrope at 280.0 CFM @ 25Pa
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property Organization
541 ELLIOT CREEK DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: ZION
Community: BRIDGEMONT AT JACI Builder
HOMES BY McKENZIE,
(AS DESIGNED) INC.
BRIDGEMONT AT JACKSONS GRP
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 1 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 3 CFM251 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization Inspection Status
541 ELLIOT CREEK DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: ZION
Yes
Community: BRI DGEMONT AT JACKSONS GRANT
Builder
Total Units in Building
HOMES BY McKENZIE, INC.
[AS DESIGNED]
Single family detached
BRIDGEMONTAT JACKSONS GRANT 234
General Building Information
Number Of Bedrooms
3
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
3,519
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
34,268
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
ZION
Community
BRIDGEMONT AT JACKSONS GRANT 234
Climate Zone
5A
Basement Wall
Basement Wall Library List
Slab AL
Name Library Type
None Present
C-M,
Energy Solutions
SLAB R-101'down, 2' in 247 On Grade ❑ ❑ 2,542.0 sq. ft. Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction Slab Camplet Underslab Perimeter Perimeter Thermal Break Effective R -value
Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
R-10 1'down. 2' in Wood Frame 1 Other No 2 1 10 No 10.00
Framed Floor
None Present
1
Building Summary
Property
Organization
541 ELLIOT CREEK DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: ZION
Community: BRI DGEMONT ATJACKSONS GRANT
Builder
Name
HOMES BY McKENZIE, INC.
[AS DESIGNED]
Surface Area
BRIDGEMONTAT JACKSONS GRANT 234
CONDIAMB
Framed Floor Library List mmdm
None Present
Rim Jois
Name
CONDIAMB
CONDIATTIC
Rim Joist Library List
uorary TYPE
G1 R-15, OSB
Inspection Status
Results are projected
70.0 sq. R.
C-M,
Energy Solutions
Exposed Exterior
G1 R-15, OSB 82.0 sq. R. Unconditioned, attached garage
Name
Effective Insulation R•value
Name
Effective R -value
G1 R-15 BATT. OSB
G1 R-15. OSB
11.691
11.972
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-15 BATT, OSB
Medium
2,942.0 sq. R.
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, OSB
Medium
322.0 sq. ft.
Attic
CONDIGAR
G1 R-15 Gar Walls
Medium
240.0 sq. tt.
Unconditioned. attached garage
Wall Library List
Name
Effective R -value
G1 R-15 BATT. OSB
13.423
G1 R-15 Gar Walls
11.972
Building Summary
Emittance Solar Surface Color
Surface Area
Location
Assignment
Property
Organization
Inspection Status
FRONT Wood Door CONDIAMB
C-MEnergy
Solutions
541 ELLIOT CREEK DR
TSI Energy Solutions
Results are projected
Exposed Exterior
0.9 0.75 Medium
CARMEL, IN 46032
Devin Sielschott
Model: ZION
Community: BRI DGEMONT ATJACKSONS GRANT
Builder
HOMES BY MCKENZIE, INC.
[AS DESIGNED]
BRIDGEMONTAT JACKSONS GRANT 234
Glazing
Name Library type Wall
Assignment Basement Wall Overhang
Assignment
Depth Overhang Ft To Overhang
Top
Ft To
Bottom
Orientation
Surface Area
BACK U-29, SHGC-27
CONDIAMB
0 0
0
West
168.0 sq. ft.
FRONT U-29, SHGC-27
CONDIAMB
0 0
0
East
114.0 sq. ft.
LEFT SIDE U-29, SHGC-27
CONDIAMB
0 0
0
South
24.0 sq. ft.
RIGHT SIDE U-29, SHGC-27
CONDIAMB
0 0
0
North
51.0 sq. ft.
slider U-29, SHGC-27
CONDIAMB
0 0
0
West
48.0 sq. ft.
Glazing Library List
Name
U-.29, SHGC-.27
Skylight
anyc LO-idcwi
027 0290
Skylight Library List
None Present
Opaque Door
Name Library Type WallAssignment Basement Wall
Emittance Solar Surface Color
Surface Area
Location
Assignment
Ab so rp to n ce
FRONT Wood Door CONDIAMB
0.9 0.75 Medium
48.0 sq. ft.
Exposed Exterior
GARAGE Steel Door CONDIGAR
Exposed Exterior
0.9 0.75 Medium
20.0 sa_ ft.
3
Building Summary
Property
Organization
541 ELLIOT CREEK DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: ZION
Community: BRIOGEMONT AT JACKSONS GRANT
Builder
HOMES BY MCKENZIE, INC.
[AS DESIGNED]
BRIDG EIJONT AT JACKSONS GRANT 234
Opaque Door Library List
Name
Effective U -factor
Steel Door
0.182
Wood Door
0.476
Inspection Status
Results are projected
C-M,
Energy Solutions
Roof Insulation
Name Library type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
j•..f.] Tiles
klAIN R-50 Blown, GR1 2,542 No Medium 2.542.0 sq. 1t. Attic
Roof Insulation Library List
Name Has Radiant Barrier
R-50 Blown, GR1 No
Whole House Infiltration
Infiltration Measurement type
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
None Present
Lighting
Interior Fluores
Ligh
10
■
Effective R -value
50.474
Shelter Class
4
0
0
ge Fluorescent 1 Garage LED Lighting
Lighting
C
4
Building Summary
Property
Organization
541 ELLIOT CREEK DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: ZION
100%
Community: BRI DGEMONT ATJACKSONS GRANT
Builder
Water Heating
HOMES BY McKENZIE, INC.
[AS DESIGNED]
0%
BRIDGEMONTAT JACKSONS GRANT 234
Onsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
A
Name
Inspection Status
Results are projected
C-M,
Energy Solutions
Hot Water Percent Load
Air conditioner 1
CA13NA048
0%
100%
0%
GAS FURNACE 1
912SA48080917
100%
0%
0%
Water Heating
ENT 50 100
0%
0%
100%
Equipment Type: 912SA4808OS17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 78
Use default EAE No
EAE [kWh] 977
Building Summary
Property
541 ELLIOT CREEK DR
CARMEL, IN 46032
Model: ZION
Community: BRI DGEMONT AT JACKSONS GRANT
[AS DESIGNED]
BRIDG EIJONT AT JACKSONS GRANT 234
Equipment Type:
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE, INC.
CA13NA048 ilp�
Equipment Type: ENT 50 100
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Electric
Forced Air
PSG (Single Speed)
13 SEER
45.5
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
Organization
541 ELLIOT CREEK DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: ZION
3519
Community: BRI DGEMONT ATJACKSONS GRANT
Builder
Supply Duct R Value
HOMES BY MCKENZIE, INC.
[AS DESIGNED]
20
BRIDGEMONTAT JACKSONS GRANT 234
956.13
Distribution System
Distribution Type
Forced Air
Heating Equipment
GAS FURNACE 1
Cooling Equipment
Air conditioner t
Sq. Feet Served
3519
# Return Grilles
3
Supply Duct R Value
20
Return Duct R Value
20
Supply Duct Area [sq. ft.]
956.13
Return Duct Area [sq. ft]
527.85
Duct Leakage to Outdoors (CFM25)
175
Total Leakage
280
Total Leakage Dud Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
90
Percent Return Area
90
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
10
Percent Return Area
10
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Inspection Status
Results are projected
C-M,
Energy Solutions
Building Summary
Property
541 ELLIOT CREEK DR
CARMEL, IN 46032
Model: ZION
Community: BRI DGEMONT AT JACKSONS GRANT
[AS DESIGNED]
BRIDGEMONTAT JACKSONS GRANT 234
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE, INC.
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
86
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
30
Drain Water Heat Recovery?
No
Clothes Dryer
Fuel Type Electric
Cef 2.62
Field Utilization Timer Controls
asher VWV
Label Energy Rating
704 kWh/Year
Electric Rate
$0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.581Therm
Capacity
2.874
Imet
❑.331
Appliances and Controls
M
Programmable thermostat?
Yes
Dishwasher Size
Standard
Dishwasher Efficiency
270 kWh
Range/Oven Fuel
Electric
Convection Oven?
No
Induction Range?
No
Refrigerator Consumption
709 kVVh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions