HomeMy WebLinkAboutA121 Elec - Reflected CeilingELECTRICAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN D@ POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX POWER OUTLET, POWER OUTLET QUADRUPLEX QUADRUPLEX ® JUNCTION BOX QJ JUNCTION BOX OCEILING MOUNTED CEILING MOUNTED JUNCTION BOX JUNCTION BOX ® BOX, BLANK COVER PLATE QB BOX, BLANK COVER PLATE ® BOX, OPEN QO BOX,OPEN P PROVIDE JUNCTION BOX P POWER AND DATA POLE ABOVE CEILING FOR O POWER POLE CONNECTION. POWER POLE BY OTHERS. FLOOR BOX WITH POWER FLOOR BOX WITH POWER 1&14 AND DATA, FLUSH AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH JUNCTION BOX AND J q JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION DATA/COMMUNICATION q OUTLET (PROVIDE BOX q OUTLET AND PULL STRING ONLY) DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42' HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL PLAN NOTES E01 PROVIDE MAG-LOCK HARDWARE AND POWER FOR BOTH MAG-LOCK AND DOORBELL AS REQUIRED TO HERCULITE DOOR. SEE DOOR SCHEDULE FOR MORE DETAILS. ALL CARD READER HARDWARE TO BE PROVIDED AND INSTALLED BY TENANT'S SECURITY VENDOR, COORDINATE WITH VENDOR FOR MORE INFORMATION, ED2 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. ED3 PROVIDE JUNCTION BOX AND DATA FOR TENANTS FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANTS FURNITURE VENDOR. E04 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 24" A.F.F. E05 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT, E06 PROVIDE POWER AT THIS LOCATION FOR TENANT'S GARBAGE DISPOSAL. E0� PROVIDE CONNECTRAC CONNECTION; COORDINATE WITH 0 TENANTS FURNITURE VENDOR. E08 PROVIDE POWER AT I8"A.F.F. CENTERED IN WALL. TA sE®R //C�> OFFICE is AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Calmed DATE: 07/12/19 M GENERAL ELEC. NOTES I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18' MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO BE WHITE. RELOCATE EXISTING OUTLETS AT SAME HEIGHT AS NEW IF THERE IS A VARIANCE. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. ALL ELECTRICAL AND MAGNETIC HARDWARE AND CONNECTIONS TO BE COMPLETED BY TENANT'S SECURITY VENDOR. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. F BREAK N ® DED r E� 021', fC OPEN OFFICE � f 1 F=======--===== I / »N �� I� CONFERENCE JU J� Cf071 ELECTRICAL PLAN 0 2' 4' 8' 16, RCP LEGEND NEW OR RELOCATED EXISTINGTO REMAIN III M EIGHT FIXTURE, 2'x4', LED � UGHT HXTURE, 2'x4', LED ❑ UGHT FIXTURE, 2'X2', LEDI 0 UGHT FIXTURE, 2'x2', LED jD RECESSED LIGHT FIXTURE, LED, 120V DIMMER DIRECTIONAL RECESSED LIGHT FIXTURE LIGHT FIXTURE, ® PENDANT NIL INDICATES NIGHT UGHT LOCA110N 3:i RECESSED UGHT FIXTURE ® UGHTFIXIURE, PENDANT INDICATES NIGHT LIGHT LOCATION ® EXIT LIGHT FIXTURE EMT LIGHT FIXTURE ® EMERGENCYLIGHT EMERGEN CY LIGHT FIXTURE FIXTURE $N LIGHT SWITCH $ UGHTSWITCH $N3 LIGHT SWITCH. SWAY $3 UGHTSWBCH,3WAY $ND LIGHT SWITCH, DIMMER $D NIGHT SWITCH, DIMMER $NP SWITCH, PROJECTOR $P SWITCH, PROJECTOR SCREEN SCREEN $NG SWITCH, GARBAGE $G SWITCH, GARBAGE DISPOSAL DISPOSAL i — LIGHT CIRCUIT -- - UGHT CIRCUIT eDNING ED, 2 SUSPENCOMINGDED, GRIED, 2 SUSPENDE0.2'x2'tSUSPENDE0.2'x2' GYPSUM BOARD ❑ GYPSUM BOARD CEILING cEINING EXISTING/RELOCATED ® DIFFUSER, LAYJN, 2'x2' DIFFUSER LAYJN.2'x2' ® EXISTING/RELOCATED ® DIFFUSER LAYJN, 1'x4' DIFFUSER, LAY IN, 1'xd' ® EXIS➢NG/RELOCATED m DFFUSER, LAYJN, 4'k4' DIFFUSER, LAY -IN, 4W EXHAUST FAN, 2'x2' � 90ING EXHAUST FAN, EXIS NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. GENERAL RCP NOTES REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 9'-7' A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND PROVIDE NEW BUILDING STANDARD CEILING TILES THROUGHOUT. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50%OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET, 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED, PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). 5. NEW DEVICES AND FACE PLATES TO BE WHITE. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLI PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. ZI AREA NOT IN CONTRACT ❑ AREA OF WORK MECHANICAL NOTES I. MECHANICALINEDINWORK TON DESIGN -B AND IS MECHANILD CAL OUTLINED THESE DRAWINGS, NO NEW MAIN MECHANICAL A DRAWINGS, APPLIANCES OR MAIN EQUIPMENTARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO V NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE m C) c INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. tiZ^' CN RCP PLAN NOTES OCq n O O Ji w O M rot C CONTROL WELCOME 101 AND OPEN OFFICE AREA LIGHTING WITH `■ o'.00 O- OR01 EXISTING OCCUPANCY SENSOR SWITCH AT THIS LOCATION. G PROVIDE NEW WHITE FACE PLATE AT THIS LOCATION. V PROVIDE BULKHEAD AT THIS LOCATION FOR TENANT'S FURNITURE R02 SYSTEM. COORDINATE EXACT HEIGHT REQUIREMENTS WITH FURNITURE VENDOR. PAINT TO MATCH ADJACENT WALL. RELOCATE DIFFUSERS & MECHANICAL DIFFUSER RELOCATION nlzl 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION REFLECTED CEILING PLAN N 0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, IESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC_ AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PAWL WITHOUTTHE WRITTEN CONSENT OF SCH07 DESIGN. CN CD li Zoz L0 WSJ ph W LL H C QN Q �YU LU C L Q z Q LLJ Ww� =�Z r r ISSUE DATE DESCRIPTION 04.29.19 PERMITSIET 05.17.19 CONSTRUCTION SET REVISIONS ARK DATE DB DESCRIPTION PROJECT NUMBER 2019.068 PROD. MGR DRAWN BY AS CRB 1ST FLOOR ELECTRICAL PLAN/ REFLECTED CEILING PLAN A121