HomeMy WebLinkAboutA111 Demo & ArchDECONSTRUCTION LEGEND EXISTING TO BE REMOVED EXISTING TO REMAIN ------ WALL WALL xxoxox PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DOOR AND FRAME DOORAND FRAME WINDOW/SIDELIGHT x WINDOW/SIDELIGHT TI - L CEILING GRID AND Ir TILES, 2'x4' CEILING GRID AND TILES, 2'x2' Fri SUPPLY AIR DIFFUSERS LIGHT FIXTURE, LED, 2'x4' r-1 LIGHT FIXTU RE, Laid LED, 2'X2' LIGHT FIXTURE, CAN a4 LIGHT SWITCH i^y EXIT LIGHT �610; ELECTRIC OUTLETS) DATA OR CT COMMUNICATION OUTLET NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. FAT 1 ��1 6._y AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION Subject to compliance With all regulations of State and Local Codes City of Cannel DATE: 07/12/19 C DECON. GENERAL NOTES I. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. F a it N II 11 1e 11 i 11 II d:_il 11: d_� 4 II F e._x_L r=p r=p it i it I I I I II 11 II 11 6 a 6 a DECONSTRUCTION PLAN 0 2' 4' 8' 16, NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BEWI I UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. W1 WALL WITH INSULATION 35/g" METALSTUDS AT 16" O.C.; ONE LAYER OF%' TYPE'K GYPSUM BOARD EACH SIDE; EXTEND WALLTO UNDERSIDE OF CEILING: FIBERGLASS SOUND BATT INSULATON INSIDE W ALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING � PARTIAL HEIGHT g WALL 3/ " METAL STUDS AT 16" O.C.; ONELAYEROF tI TYPE'X" GYPSUMBOARD - EACH SIDE; SEE ELEVATON FOR HEIGHT; PROVIDE I" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED. AREA NOT IN CONTRACT ❑ AREA OF WORK ARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN allyWALL WALL W� ® PARTIAL HEIGHT WALL ® PARTIAL HEIGHT WALL a�u WINDOW/SIDELIGHT n- WINDOW/SIDELIGHT DOOR AND FRAME )SEE DDOOR AND FRAME OOR SCHEDULE] NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFERTO FINISH PLAN FORALL ACCENT/SPECIALTY PAINTOR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVELS DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. CONFIRM THAT ALL EXISTING DEMISING WALLS ARE FULLY INSULATED. IF NOT, PROVIDE NEW INSULATIONAS REQUIRED, PLAN NOTES A0T ALIGN FINISHED WALL SURFACES, PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS, EPROVIDE PLYWOOD PHONE BOARD, 4'X8'aq", PAINTED WITH FIRE A02 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. A03 NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. PROVIDE DRYWALL WRAPPED OPENING FOR TENANT'S FU RNTURE A04 SYSTEM. COORDINATE EXACT DIMENSIONS WITH FURNITURE E� VENDOR. PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR A05 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. A06 PROVIDE MANUAL ROLLER SHADES; COLOR FEE. POt PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS WITH GARBAGE DISPOSAL, REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING, OP02 PROVIDE COPPER WATER LINE (POLYTUBE IS NOT PERMITTED) FOR REFRIGERATOR AND WATER COOLER. CONFIRM LOCATION WITH TENANT. ARCHITECTURAL PLAN N�vM/ 0 2' 4' 8' 16' W THIS DRAW NGr AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROP ERIY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PAR, WITHOUTTHE WRITTEN CONSENT OF SCHOTT DESIGNwill N 0 II— Zoz W� J QN< �YU WEE- Q L U = II— F G `z LU C Z Q L.I J Z ^_ No r ISSUE DATE DESCRIPTION 04.29.19 PERMIT SD 05.17.19 CONSTRUCTION SD REVISIONS ARK DATE DB DESCRIPTION PROJECT NUMBER 2019.068 PROD. MGR DRAWN BY AS CRB Mail 1ST FLOOR DEMOLITION PLAN/ ARCHITECTURAL FLOOR PLAN A111