HomeMy WebLinkAbout19060199 Correspondence1
Kristin Ricketts
From:Blunk, Alan <ABlunk@dhs.IN.gov>
Sent:Tuesday, June 25, 2019 11:32 AM
To:Brittany Winchester
Cc:Callahan, Sean; Davis, Larry; Flick, Ronald
Subject:RE: State Exempt Review Request - 10401 N. Meridian Street
Attachments:SpecSuite110_SP1_052219.pdf
Hello Brittany,
Based on the information and attachments provided, the project is EXEMPT from filing with the State of Indiana DHS
Plan Review Section in accordance with 675 IAC 12-6-4.
675 IAC 12-6-4 Exemptions from design release requirement
Authority: IC 22-13-2-13
Affected: IC 4-21.5; IC 12-13-4-3; IC 22-15-3
Sec. 4.
(b) Design releases are necessary for the remodeling or altering of all Class 1 structures, except work limited to one (1) or more of the
following:
(1) Any of the buildings or structures the new construction of which is exempted by subsection (a).
(2) Plumbing work as follows:
(A) Replacement of piping, valves, or fixtures, provided that the replacement does not involve relocation of fixtures.
(B) Installation of plumbing fixtures, provided that the drainage fixture unit count does not exceed five (5).
(3) Electrical work as follows:
(A) Replacement in the same location of electrical equipment or devices of a similar type and rating, including an increase in current
capacity in nonhazardous areas where there is no change in voltage or phases.
(D) Installation of branch circuits not exceeding the capacity of the electrical distribution system within the existing building.
(E) Low-energy power, control, and signal circuits of Classes II and III as defined in the Indiana Electrical Code except circuits for
fire detection or fire alarm systems.
(G) Except for fire detection or fire alarm systems, electrical wiring, devices, appliances, apparatus, or equipment:
(i) operating at less than twenty-five (25) volts; and
(ii) not capable of supplying more than fifty (50) watts of energy.
(4) Mechanical work as follows:
(B) Replacement of mechanical appliances and equipment with a similar type and rating in the same location.
(5) Miscellaneous work as follows:
(A) Painting, papering, and replacement of coverings on:
(i) walls;
(ii) ceilings;
(iv) floors;
and similar finish work, including replacement or re-glazing of glass.
(B) Cases, counters, and partitions not over six (6) feet in height.
(D) Installation of one (1) or more non load-bearing partitions not to exceed a total of one hundred (100) lineal feet in length provided
it is not part of a corridor or a partition that is required to be of fire-resistive construction.
(6) Fire sprinkler systems as follows:
(A) Replacement of components of existing wet fire sprinkler systems of light hazard or ordinary hazard classification as defined in
675 IAC 13, including:
(i) replacement of sprinkler heads;
(ii) replacement of equipment; or
(iii) replacement of piping to restore a system to its original condition and configuration.
(B) Alteration of existing light hazard or ordinary hazard fire sprinkler systems, including:
(i) the addition or alteration of up to an aggregate of twenty (20) sprinkler heads in a wet pipe system for light or ordinary hazard
design;
(c) All additions or alterations permitted by this subdivision [sic.] shall be documented by the installer and kept on file with the
maintenance and testing records required by 675 IAC 22 and 675 IAC 28, specifically the applicable editions of NFPA 13 and NFPA
25.
2
(d) The design release requirements including filing of plans and specifications shall apply for any work otherwise exempted by
subsection (b) when a part of, supplemental to, or an accessory of a construction project that otherwise requires a design release.
(e) Construction work on a Class 1 structure exempted from the design release requirements under this section is not exempt from
compliance with other rules of the commission.
You may need to submit the project locally.
Thank you,
Alan L. Blunk RA CPE CBI FI FII | Plan Review Section Chief
Division of Fire and Building Safety | Plan Review Branch
Indiana Department of Homeland Security
302 West Washington Street, Room E-245
Indianapolis, IN 46204
Tel: 317-232-2222
Email: ablunk@dhs.in.gov
Web: http://www.in.gov/dhs/3658.htm
From: Brittany Winchester [mailto:bwinchester@schottdesign.com]
Sent: Tuesday, June 25, 2019 10:41 AM
To: Blunk, Alan <ABlunk@dhs.IN.gov>
Cc: Kemp, Carolyn <ckemp@dhs.IN.gov>
Subject: RE: State Exempt Review Request - 10401 N. Meridian Street
Importance: High
Hi Alan – I wanted to follow up on the email below + attachment sent on May 22nd. Please let me know if you have any
questions and when you think we could expect an answer? Our client is anxious to get started on the work.
Thank you
Brittany Winchester
Project Interior Designer
Schott Design
450 East 96th Street, Suite 175
Indianapolis, Indiana 46240
Direct: 317.762.0653
Main: 317.387.1700
bwinchester@schottdesign.com
From: Brittany Winchester
Sent: Monday, June 10, 2019 7:58 AM
To: ABlunk@dhs.IN.gov
Subject: RE: State Exempt Review Request - 10401 N. Meridian Street
Hi Alan – I hope you had a nice weekend! I wanted to follow up on the email below + attachment sent on May
22nd. Please let me know if you have any questions and when you think we could expect an answer! Our client is
anxious to get started on the work.
Thank you
Brittany Winchester
Project Interior Designer
3
Schott Design
450 East 96th Street, Suite 175
Indianapolis, Indiana 46240
Direct: 317.762.0653
Main: 317.387.1700
bwinchester@schottdesign.com
From: Brittany Winchester
Sent: Wednesday, May 29, 2019 10:30 AM
To: ABlunk@dhs.IN.gov
Subject: RE: State Exempt Review Request - 10401 N. Meridian Street
Hi Alan – I hope you had a nice long weekend! I wanted to follow up on the email below + attachment. Please let me
know if you have any questions and when you think we could expect an answer!
Thank you
Brittany Winchester
Project Interior Designer
Let's create something extraordinary together...
Schott Design
450 East 96th Street, Suite 175
Indianapolis, Indiana 46240
Direct: 317.762.0653
www.schottdesign.com
From: Brittany Winchester
Sent: Wednesday, May 22, 2019 1:19 PM
To: ABlunk@dhs.IN.gov
Subject: State Exempt Review Request - 10401 N. Meridian Street
Hi Alan - We have a project that we believe is exempt from state review. Please see attached + below and let me know
if you need further clarification. Thanks!
Building/Project Details:
Address is 10401 North Meridian Street Carmel, IN 46290
Building square footage is 128,836 sf.
Proposed tenant space is 2,420 sf.
Existing/proposed occupancy: Business
Building construction type is II-B
Fully sprinklered
4 floors
Scope of work:
1. 8 lineal feet of new partial height wall being built. No walls are fire rated construction.
2. Electrical work limited to adding 4 outlets. Will not exceed building service.
3. Plumbing work is limited to installation of 1 sink.
4. All new cabinetry is under 6’ in height.
5. Sprinkler rework – under 20 heads to be relocated.
6. No fire alarm rework – all existing fire alarm appliances to remain and none to be added
7. Rework of diffuser locations per new wall location.
8. New finishes including carpet and paint
4
Brittany Winchester
Project Interior Designer
Let's create something extraordinary together...
Schott Design
450 East 96th Street, Suite 175
Indianapolis, Indiana 46240
Direct: 317.762.0653
www.schottdesign.com
CDR Exemption Form
*for City of Indianapolis Department of Business and Neighborhood Services review use ONLY*
City of Indianapolis
Department of Business and Neighborhood Services
1200 Madison Ave, Suite 100
Indianapolis, IN 46225
(317)327-8700
www.indy.gov/permits
8/25/2016
Owner/Tenant Name: _____________________________________
Project Address: _____________________________________, Suite/floor:_______
Applicant Information:
Name:________________________ Phone (___)____-______, Fax (___)____-______
Business Name: _________________Phone (___)____-______, Fax (___)____-______
Project Information:
Change of Occupancy yes ___ no ___ Existing Occ____ Proposed Occ_____
New Structure/Addition yes ___ no ___ Additional Sq. Ft.___________________
Remodel/Alteration yes ___ no ___ Existing Sq. Ft. _____________________
Project Description: _____________________________________________________
______________________________________________________________________
Will this project include any of the following:
Electrical yes ___ no ___ (Description)____________________________
Plumbing yes ___ no ___ (Description)____________________________
HVAC yes ___ no ___ (Description)____________________________
Based on the work described herein, this project:
___ is exempt from plan filing with the IDHS, Building Safety/Services, Plan Review.
Per sec 675 IAC 12-6-4-___-___-___ & 675 IAC 12-6-4-___-___-___
675 IAC 12-6-4-___-___-___ & 675 IAC 12-6-4-___-___-___
___ is not exempt from plan filing with the IDHS, Building Safety/Services, Plan
Review. Per the following explanation:
____________________________________________________________________
And a local building permit will not be issued without a construction design release from:
Indiana Department of Homeland Security
Division of Building Safety/Services, Plan Review
402 W. Washington St., Room E-245
Indianapolis, IN 46204-2739
Phone (317) 232-1431
This project is subject to compliance with all applicable rules and regulations of the State Board of
Health, Fire Prevention and Building Safety Commission, local standards and procedures, and local
zoning ordinances.
Signature (Applicant) __________________________________ Date ___________
Signature ( Project Dev. Analyst) __________________________________ Date ___________
Signature (Building Code Analyst) __________________________________ Date ___________
Meridian Plaza 2, Suite 110
10401 North Meridian Street Carmel, IN 46290 10401 North Meridian Street Carmel, IN 46290 10401 North Meridian Street Carmel, IN 46290 110
Kristin Ricketts 773 842 2124
BuildSmart Constr. 317 296-8090
x
8 ft partial wall, 4 electrical outlets, replace 1 sink, relocate
sprink heads, not adding fire alarm, rework diffuser, cabinet, carpet/paint.
b 2 A b 2 B
b 3 A b 3 D
AND exempt: 675 IAC 12-6-4-b-3-D and 675 IAC 12-6-4-b-6-A
Kristin Ricketts 06/26/19
4
4
4